Role of acoustic cavitation in the delivery and monitoring of cancer treatment by high-intensity focused ultrasound (HIFU)
Open accessThe DOI matches its Crossref record; 60 of the 60 references it cites were found in a registry or an index.
Abstract
Acoustic cavitation has been shown to play a key role in a wide array of novel therapeutic ultrasound applications. This paper presents a brief discussion of the physics of thermally relevant acoustic cavitation in the context of high-intensity focussed ultrasound (HIFU). Models for how different types of cavitation activity can serve to accelerate tissue heating are presented, and results suggest that the bulk of the enhanced heating effect can be attributed to the absorption of broadband acoustic emissions generated by inertial cavitation. Such emissions can be readily monitored using a passive cavitation detection (PCD) scheme and could provide a means for real-time treatment monitoring. It is also shown that the appearance of hyperechoic regions (or bright-ups) on B-mode ultrasound images constitutes neither a necessary nor a sufficient condition for inertial cavitation activity to have occurred during HIFU exposure. Once instigated at relatively large HIFU excitation amplitudes, bubble activity tends to grow unstable and to migrate toward the source transducer, causing potentially undesirable pre-focal damage. Potential means of controlling inertial cavitation activity using pulsed excitation so as to confine it to the focal region are presented, with the intention of harnessing cavitation-enhanced heating for optimal HIFU treatment delivery. The role of temperature elevation in mitigating bubble-enhanced heating effects is also discussed, along with other bubble-field effects such as multiple scattering and shielding.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Analysis of Tissue and Arterial Blood Temperatures in the Resting Human Forearm
Pennes, H. H. (1948) · Journal of Applied Physiology · doi:10.1152/jappl.1948.1.2.93 · Cited by 4,646
Analysis of Tissue and Arterial Blood Temperatures in the Resting Human Forearm
Pennes, H. H. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.85.1.5 · Cited by 3,982
Suslick, K. S. (1990) · Science · doi:10.1126/science.247.4949.1439 · Cited by 2,897
Leighton, T. G. (2012) · Cited by 2,284
Noninvasive MR Imaging–guided Focal Opening of the Blood-Brain Barrier in Rabbits
Hynynen, K., McDannold, N., Vykhodtseva, N., & Jolesz, F. A. (2001) · Radiology · doi:10.1148/radiol.2202001804 · Cited by 1,456
XVI.On musical air-bubbles and the sounds of running water
Minnaert, M. (1933) · The London, Edinburgh, and Dublin Philosophical Magazine and Journal of Science · doi:10.1080/14786443309462277 · Cited by 1,350
Bubble oscillations of large amplitude
Keller, J. B., & Miksis, M. (1980) · The Journal of the Acoustical Society of America · doi:10.1121/1.384720 · Cited by 1,346
High-intensity focused ultrasound in the treatment of solid tumours
Kennedy, J. E. (2005) · Nature Reviews Cancer · doi:10.1038/nrc1591 · Cited by 1,282
Neppiras, E. A. (1980) · Physics Reports · doi:10.1016/0370-1573(80)90115-5 · Cited by 775
Bubble dynamics in a compressible liquid. Part 1. First-order theory
Prosperetti, A., & Lezzi, A. M. (1986) · Journal of Fluid Mechanics · doi:10.1017/s0022112086000460 · Cited by 748
Cited by
Qian, X., Zheng, Y., & Chen, Y. (2016) · Advanced Materials · doi:10.1002/adma.201602012 · Cited by 882
High intensity focused ultrasound: Physical principles and devices
ter Haar, >., & Coussios, C. (2007) · International Journal of Hyperthermia · doi:10.1080/02656730601186138 · Cited by 805
Dzah, C. S., Duan, Y., Zhang, H., Wen, C., Zhang, J., Chen, G., & Ma, H. (2020) · Food Bioscience · doi:10.1016/j.fbio.2020.100547 · Cited by 544
Applications of Acoustics and Cavitation to Noninvasive Therapy and Drug Delivery
Coussios, C. C., & Roy, R. A. (2008) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.40.111406.102116 · Cited by 532
Self-citationHeating technology for malignant tumors: a review
Kok, H. P., Cressman, E. N. K., Ceelen, W., Brace, C. L., Ivkov, R., Grüll, H., ter Haar, G., Wust, P., & Crezee, J. (2020) · International Journal of Hyperthermia · doi:10.1080/02656736.2020.1779357 · Cited by 422
Self-citationZhang, P., Bachman, H., Ozcelik, A., & Huang, T. J. (2020) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-090919-102205 · Cited by 316
Morris, P., Hurrell, A., Shaw, A., Zhang, E., & Beard, P. (2009) · The Journal of the Acoustical Society of America · doi:10.1121/1.3117437 · Cited by 285
Mechanical and Biological Effects of Ultrasound: A Review of Present Knowledge
Izadifar, Z., Babyn, P., & Chapman, D. (2017) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2017.01.023 · Cited by 280
Clinical and future applications of high intensity focused ultrasound in cancer
Al-Bataineh, O., Jenne, J., & Huber, P. (2012) · Cancer Treatment Reviews · doi:10.1016/j.ctrv.2011.08.004 · Cited by 241
Wang, X., Chen, H., Chen, Y., Ma, M., Zhang, K., Li, F., Zheng, Y., Zeng, D., Wang, Q., & Shi, J. (2012) · Advanced Materials · doi:10.1002/adma.201104033 · Cited by 239
Passive Spatial Mapping of Inertial Cavitation During HIFU Exposure
Gyongy, M., & Coussios, C.-C. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2026907 · Cited by 232
“In addition to potentially causing direct mechanical damage, the broadband acoustic emissions associated with inertial cavitation have been shown to increase heating at the HIFU focus significantly [2], by redistributing part of the energy contained within the primary HIFU signal to higher frequencies that are more re…”
BackgroundMicrobubble-mediated ultrasound therapy: a review of its potential in cancer treatment
Ibsen, S., Schutt, & Esener (2013) · Drug Design, Development and Therapy · doi:10.2147/dddt.s31564 · Cited by 219
“45,46 Low intensity ultrasound, like that used for imaging, has little effect on tissue temperature or structure.”
Nucleation, mapping and control of cavitation for drug delivery
Stride, E., & Coussios, C. (2019) · Nature Reviews Physics · doi:10.1038/s42254-019-0074-y · Cited by 185
Passive cavitation imaging with ultrasound arrays
Salgaonkar, V. A., Datta, S., Holland, C. K., & Mast, T. D. (2009) · The Journal of the Acoustical Society of America · doi:10.1121/1.3238260 · Cited by 184
Qin, P., Han, T., Yu, A. C. H., & Xu, L. (2018) · Journal of Controlled Release · doi:10.1016/j.jconrel.2018.01.001 · Cited by 173
“However, the used high intensity ultrasound in hyperthermia can produce rapid local temperature increase and cause unpredictable and irreversible damage [6,7].”
BackgroundKang, Z., Yang, M., Feng, X., Liao, H., Zhang, Z., & Du, Y. (2022) · International Journal of Nanomedicine · doi:10.2147/ijn.s360161 · Cited by 21
Metadata
- Authors
- Coussios, >. C., Farny, C. H., Ter Haar, G., & Roy, R. A.
- Venue
- International Journal of Hyperthermia
- Publisher
- Informa UK Limited
- Published
- 2007-01-01
- Volume
- 23
- Issue
- 2
- Pages
- 105-120
- ISSN
- 0265-6736 (ISSN-L)
- 1464-5157
- OpenAlex
- W2025771207
- Cited by
- 469
- References
- 60
- FWCI
- 12.80
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.