Study of the inward protection efficiency of various facial masks
The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
COVID-19 and other respiratory diseases largely spread through aerosols and droplets shed by an infected individual. Face masks can act as both a source control measure and a method of protection from airborne disease. In this work, the inward protection efficiencies of N95, KN95, and ASTM level 3 surgical masks worn both regularly and “tied and tucked” are evaluated for aerosol particle sizes ranging from 0.2 to 1 μm. Tests are conducted on a realistic soft-surface medium NIOSH manikin to accurately simulate the human/mask interface. For filtering facepiece respirators, the N95 mask is found to provide significantly greater protection than the KN95 masks. A marginal increase in mean inward protection efficiency is observed by improving surgical mask fit through the “tie and tuck” method. Mean inward protection efficiency of 86.5±2.5%, 61.5±6.0%, 20.4±3.9%, and 24.2±4.6% for N95, KN95, regularly worn surgical mask, and tied and tucked surgical mask, respectively, were found. Comparisons with material filtration efficiency highlight that inward protection is impacted significantly by leakage due to gaps at the mask-face interface. Minimal variation in inward protection efficiency across the tested particle size range was observed. A weighted analysis of available data for N95 and surgical masks is performed to obtain estimates for mean inward efficiency ranges for these mask types that can guide future risk assessment and modeling studies. Copyright © 2025 American Association…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Aerosol Technology Properties, Behavior, and Measurement of Airborne Particles
LAUCKS, M. L. (2000) · Journal of Aerosol Science · doi:10.1016/s0021-8502(99)00571-6 · Cited by 3,367
An evidence review of face masks against COVID-19
Howard, J., Huang, A., Li, Z., Tufekci, Z., Zdimal, V., van der Westhuizen, H.-M., von Delft, A., Price, A., Fridman, L., Tang, L.-H., et al. (2021) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2014564118 · Cited by 1,529
Contributing factors to personal protective equipment shortages during the COVID-19 pandemic
Cohen, J., & Rodgers, Y. V. D. M. (2020) · Preventive Medicine · doi:10.1016/j.ypmed.2020.106263 · Cited by 528
The fluid dynamics of disease transmission
Bourouiba, L. (2021) · Annual Review of Fluid Mechanics · doi:10.1146/annurev-fluid-060220-113712 · Cited by 366 · cited 5×
“This study aims to quantify the inward protection efficiency for aerosol particles ranging from 0.2 to 1 l m for the KN95 and the tied and tucked surgical mask, two interventions that have proliferated greatly during the recent COVID-19 pandemic, relative to the N95 and the regularly worn surgical mask.”
InfluentialGrinshpun, S. A., Haruta, H., Eninger, R. M., Reponen, T., McKay, R. T., & Lee, S.-A. (2009) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620903120086 · Cited by 353
MacIntyre, C. R., & Chughtai, A. A. (2020) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2020.103629 · Cited by 319
Lindsley, W. G., Pearce, T. A., Hudnall, J. B., Davis, K. A., Davis, S. M., Fisher, M. A., Khakoo, R., Palmer, J. E., Clark, K. E., Celik, I., et al. (2012) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2012.684582 · Cited by 300 · cited 1×
“Similarly, observations of nine patients with influenza by Lindsley et al. (2012) found that, on average, roughly three-quarters of particles expelled during coughing are below 1 l m in size.”
Lee, S.-A., Grinshpun, S. A., & Reponen, T. (2008) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/men005 · Cited by 235 · cited 2×
“Multiple studies conducted both before the COVID-19 pandemic (Lee et al. 2008, Lee et al. 2016; Grinshpun et al. 2009; Shakya et al. 2017) and after (Bagheri et al. 2021; Pan et al. 2021; Wendling et al. 2021; Koh et al. 2022) evaluated the inward personal protection offered by various face masks.”
Respiratory aerosols and droplets in the transmission of infectious diseases
Pöhlker, M. L., Pöhlker, C., Krüger, O. O., Förster, J., Berkemeier, T., Elbert, W., Fröhlich‐Nowoisky, J., Pöschl, U., Bagheri, G., Bodenschatz, E., et al. (2023) · Reviews of Modern Physics · doi:10.1103/revmodphys.95.045001 · Cited by 231
Evaluating the Efficacy of Cloth Facemasks in Reducing Particulate Matter Exposure
Shakya, K. M., Noyes, A., Kallin, R., & Peltier, R. E. (2017) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/jes.2016.42 · Cited by 202 · cited 1×
“Multiple studies conducted both before the COVID-19 pandemic (Lee et al. 2008, Lee et al. 2016; Grinshpun et al. 2009; Shakya et al. 2017) and after (Bagheri et al. 2021; Pan et al. 2021; Wendling et al. 2021; Koh et al. 2022) evaluated the inward personal protection offered by various face masks.”
Inward and Outward Effectiveness of Cloth Masks, a Surgical Mask, and a Face Shield
Pan, J., Harb, C., Leng, W., & Marr, L. C. (2021) · Aerosol Science and Technology · doi:10.1080/02786826.2021.1890687 · Cited by 186 · cited 2×
“Multiple studies conducted both before the COVID-19 pandemic (Lee et al. 2008, Lee et al. 2016; Grinshpun et al. 2009; Shakya et al. 2017) and after (Bagheri et al. 2021; Pan et al. 2021; Wendling et al. 2021; Koh et al. 2022) evaluated the inward personal protection offered by various face masks.”
Brooks, J. T., Beezhold, D. H., Noti, J. D., Coyle, J. P., Derk, R. C., Blachere, F. M., & Lindsley, W. G. (2021) · MMWR. Morbidity and Mortality Weekly Report · doi:10.15585/mmwr.mm7007e1 · Cited by 182
Impedance pneumography: Noise as signal in impedance cardiography
Ernst, J. M., Litvack, D. A., Lozano, D. L., Cacioppo, J. T., & Berntson, G. G. (1999) · Psychophysiology · doi:10.1017/s0048577299981003 · Cited by 168
Clapp, P. W., Sickbert-Bennett, E. E., Samet, J. M., Berntsen, J., Zeman, K. L., Anderson, D. J., Weber, D. J., Bennett, W. D., & Program, U. C. F. D. C. A. P. E. (2021) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2020.8168 · Cited by 167 · cited 3×
“The protection of a surgical mask is not significantly improved using the “tie and tuck” method, contradicting findings from Clapp et al. (2021).”
Origin of Exhaled Breath Particles from Healthy and Human Rhinovirus-Infected Subjects
Fabian, P., Brain, J., Houseman, E. A., Gern, J., & Milton, D. K. (2011) · Journal of Aerosol Medicine and Pulmonary Drug Delivery · doi:10.1089/jamp.2010.0815 · Cited by 166
Generation and control of tracer particles for optical flow investigations in air
Kähler, C., Sammler, B., & Kompenhans, J. (2002) · Experiments in Fluids · doi:10.1007/s00348-002-0492-x · Cited by 165
An upper bound on one-to-one exposure to infectious human respiratory particles
Bagheri, G., Thiede, B., Hejazi, B., Schlenczek, O., & Bodenschatz, E. (2021) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2110117118 · Cited by 144
Lee, S.-A., Hwang, D.-C., Li, H.-Y., Tsai, C.-F., Chen, C.-W., & Chen, J.-K. (2016) · Journal of Healthcare Engineering · doi:10.1155/2016/8572493 · Cited by 134
Mahmood, S. U., Crimbly, F., Khan, S., Choudry, E., & Mehwish, S. (2020) · Cureus · doi:10.7759/cureus.8248 · Cited by 127
Shah, Y. H., Kurelek, J. W., Peterson, S. D., & Yarusevych, S. V. (2021) · Physics of Fluids · doi:10.1063/5.0057100 · Cited by 90
Self-citationDuncan, S., Bodurtha, P., & Naqvi, S. (2021) · PLOS ONE · doi:10.1371/journal.pone.0258191 · Cited by 75 · cited 1×
“Notably, the inward protection efficiency of KN95 and tied and tucked surgical masks across different aerosol particle sizes remains unclear (Brooks 2021; Clapp et al. 2021; Duncan et al. 2021).”
Filtration Performance of FDA-Cleared Surgical Masks
Rengasamy*, S., Miller, A., Eimer, B. C., & Shaffer, R. E. (2009) · Journal of the International Society for Respiratory Protection · doi:10.66828/001c.167200 · Cited by 69 · cited 2×
“Similar requirements for ASTM-compliant surgical masks exist, being categorized into three barrier levels, from the lowest filter efficiency at level 1 to the highest at levels 2 and 3 (Rengasamy et al. 2009; Jones and Rempel 2021).”
Sehgal, N. J., & Milton, D. K. (2021) · Frontiers in Public Health · doi:10.3389/fpubh.2021.747894 · Cited by 68
Rengasamy, S., Eimer, B. C., & Szalajda, J. (2014) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2013.866715 · Cited by 61 · cited 1×
“The notable difference between the apparent inward protection efficiency of the tested barriers and their material filtration efficiencies points to the deleterious effect of leakages known to impact mask performance (Grinshpun et al. 2009; Rengasamy et al. 2014).”
Koh, X. Q., Sng, A., Chee, J. Y., Sadovoy, A., Luo, P., & Daniel, D. (2021) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2021.105905 · Cited by 54
Wendling, J.-M., Fabacher, T., Pébaÿ, P., Cosperec, I., & Rochoy, M. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph18041942 · Cited by 48
Wolff, E. F., Pal, L., ALTUN, T., Madankumar, R., Freeman, R., Amin, H. K., Harman, M., Santoro, N. F., & Taylor, H. S. (2010) · Fertility and Sterility · doi:10.1016/j.fertnstert.2010.09.025 · Cited by 44
Jones, R. M., & Rempel, D. M. (2021) · Annals of Work Exposures and Health · doi:10.1093/annweh/wxab008 · Cited by 39
Lindsley, W. G., Beezhold, D. H., Coyle, J. P., Derk, R. C., Blachère, F. M., Boots, T. E., Reynolds, J. S., McKinney, W., Sinsel, E. W., & Noti, J. D. (2021) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2021.1939879 · Cited by 35
The Flow Physics of Face Masks
Mittal, R., Breuer, K., & Seo, J. H. (2022) · Annual Review of Fluid Mechanics · doi:10.1146/annurev-fluid-120720-035029 · Cited by 29
Brochot, C., Saidi, M. N., & Bahloul, A. (2020) · Annals of Work Exposures and Health · doi:10.1093/annweh/wxaa101 · Cited by 16
Tidal spirometric curves obtained from a nasal cannula
Hebbink, R. H. J., & Hagmeijer, R. (2021) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2021.09.004 · Cited by 7
Quantification of face seal leakage using parallel resistance model
Pushpawela, B., Chea, P., Ward, R. X., & Flagan, R. C. (2023) · Physics of Fluids · doi:10.1063/5.0177717 · Cited by 5
Mechanistic investigation of fitted mask source control efficacy for sub-micrometer aerosols
Pieris, S., Leung, R., Yarusevych, S. V., Peterson, S. D., & Duriseti, R. S. (2025) · Aerosol Science and Technology · doi:10.1080/02786826.2025.2453587 · Cited by 3
Self-citationJeon, E.-J., Lee, A. L., Jung, Y., et al. (2023) · Fashion & Textile Research Journal · doi:10.5805/sfti.2023.25.2.248 · Cited by 1
Research works printed but not linked: 2
- ISO 2016. Respiratory protective devices - methods of test and test equipment–part 5: Breathing machine, metabolic simulator, rpd headforms and torso, tools and verification tools. Geneva, CH: Standard, International Organization for Standardization.
- ISO 2019. Respiratory protective devices - methods of test and test equipment–part 1: Determination of inward leakage. Geneva, CH: Standard, International Organization for Standardization.
Metadata
- Authors
- El Khayri, H., Pieris, S., Peterson, S. D., & Yarusevych, S.
- Affiliations
- Mechanical and Mechatronics Engineering, University of Waterloo
- Queen's University (CA)
- University of Waterloo (CA)
- Corresponding author
- Peterson, Sean D.
- Venue
- Aerosol Science and Technology
- Publisher
- Informa UK Limited
- Published
- 2025-09-08
- Volume
- 59
- Issue
- 12
- Pages
- 1486-1497
- ISSN
- 0278-6826 (ISSN-L)
- 1521-7388
- OpenAlex
- W4414051629
- Semantic Scholar
- 98ca04728d1f22193e598bc57c6cb92c5142383d
- Cited by
- 0
- References
- 35
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Aerosol Science and Technology (publishedVersion)
- Funders
- Natural Sciences and Engineering Research Council of Canada
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Aerosol Filtration and Electrostatic Precipitation
- Social Sciences › Sociology and Political Science › COVID-19 Prevention and Impact
- Keywords
- face masks, N95 respirators, KN95 masks, surgical masks, aerosol filtration, mask fit, COVID-19 pandemic, airborne transmission, aerosol particle size, respiratory protection
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.