Intelligent multifunction myoelectric control of hand prostheses
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Intuitive myoelectric prosthesis control is difficult to achieve due to the absence of proprioceptive feedback, which forces the user to monitor grip pressure by visual information. Existing myoelectric hand prostheses form a single degree of freedom pincer motion that inhibits the stable prehension of a range of objects. Multi-axis hands may address this lack of functionality, but as with multifunction devices in general, serve to increase the cognitive burden on the user. Intelligent hierarchical control of multiple degree-of-freedom hand prostheses has been used to reduce the need for visual feedback by automating the grasping process. This paper presents a hybrid controller that has been developed to enable different prehensile functions to be initiated directly from the user's myoelectric signal. A digital signal processor (DSP) regulates the grip pressure of a new six-degree-of-freedom hand prosthesis thereby ensuring secure prehension without continuous visual feedback.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149 · cited 3×
“[11] at the University of New Brunswick.”
BackgroundSelf-citationLight, C. M., Chappell, P. H., & Kyberd, P. J. (2002) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2002.32737 · Cited by 417
Self-citation
Cited by
Brain–machine interfaces: past, present and future
Lebedev, M. A., & Nicolelis, M. A. L. (2006) · Trends in Neurosciences · doi:10.1016/j.tins.2006.07.004 · Cited by 1,875
Myoelectric forearm prostheses: State of the art from a user-centered perspective
Peerdeman, B., Boere, D., Witteveen, H., Huis in `tVeld, R., Hermens, H., Stramigioli, S., Rietman, H., Veltink, P., & Misra, S. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.08.0161 · Cited by 469
Design of a cybernetic hand for perception and action
Carrozza, M. C., Cappiello, G., Micera, S., Edin, B. B., Beccai, L., & Cipriani, C. (2006) · Biological Cybernetics · doi:10.1007/s00422-006-0124-2 · Cited by 341
Schiefer, M., Tan, D., Sidek, S. M., & Tyler, D. J. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/1/016001 · Cited by 255
“This lack of sensation and reliance on alternative sensory input is one of the primary complaints associated with myoelectric prostheses [10, 11].”
BackgroundLi, L.-J., Zhang, J., Zhang, F., Lineaweaver, W. C., Chen, T.-Y., & Chen, Z.-W. (2005) · Microsurgery · doi:10.1002/micr.20159 · Cited by 14
Metadata
- Authors
- Light, C. M., Chappell, P. H., Hudgins, B., & Engelhart, K.
- Venue
- Journal of Medical Engineering & Technology
- Publisher
- Informa UK Limited
- Published
- 2002-01
- Volume
- 26
- Issue
- 4
- Pages
- 139-146
- ISSN
- 0309-1902 (ISSN-L)
- 1464-522X
- OpenAlex
- W2162377276
- Cited by
- 154
- References
- 2
- FWCI
- 2.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Intelligent multifunction myoelectric control of hand prostheses. https://app.cochat.ai/papers/10.1080/03091900210142459
- The paper
- Light, C. M., Chappell, P. H., Hudgins, B., & Engelhart, K. (2002). Intelligent multifunction myoelectric control of hand prostheses. Journal of Medical Engineering & Technology. https://doi.org/10.1080/03091900210142459
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.