Abstract

The purpose of this study was to evaluate the value of utilizing longitudinal intrafascicular electrodes (LIFEs) in collecting and analyzing sensory signals from the peripheral nerve. The longitudinal intrafascicular electrodes were made of 25-microm Teflon-insulated Pt/Ir wire and implanted into the fascicle of the superficial peroneal nerves in a feline model. The sensory signals at rest status and induced with various stimulations were recorded. The action potential area, frequency, coefficient of variation (CV) of the peak, and functional spectrum were then analyzed by the MF Lab version 3.01 software package. The results showed that the sensory nerve action potentials (SNAPs) were 0-2 spikes per second at rest state; the count was increased when stimulation was administered. SNAPs were 16-24 spikes per second when scraping stimulation was applied. The pulse intervals and the waveform remained consistent. SNAPs burst and were clustered when stress stimulation was given. The comparison of area, frequency, and CV of the peak showed statistically significant differences between these parameters receiving different stimulations. The functional spectrum analysis showed that the frequency of action potential increased when the stress stimulation was applied. In conclusion, LIFEs can sensitively collect sensory signals and provide a good interface to analyze sensory information from peripheral fasciculi. These data provide useful information for further study of control of elect…

Integrity signals

Registry

Crossref · 10.1002/micr.20159

Cites

35 of 35 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Li, L.-J., Zhang, J., Zhang, F., Lineaweaver, W. C., Chen, T.-Y., & Chen, Z.-W.
Affiliations
  • Fudan University (CN)
  • University of Mississippi Medical Center (US)
Venue
Microsurgery
Publisher
Wiley
Published
2005
Volume
25
Issue
7
Pages
561-565
ISSN
  • 0738-1085 (ISSN-L)
  • 1098-2752
OpenAlex
W2154332792
Cited by
14
References
35
Citations by year
2024: 1 · 2023: 3 · 2020: 1 · 2019: 2 · 2018: 2 · 2016: 1
FWCI
0.48
Type
journal article
Language
en
Open access
closed
Locations
  • Microsurgery (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
  • Life Sciences › Neuroscience › Neurology › Vagus Nerve Stimulation Research
Keywords
sensory nerve action potential, peripheral nerves, superficial peroneal nerve, feline model, neural recording
MeSH terms
Action Potentials, Animals, Cats, Electric Conductivity, Electric Stimulation, Electrodes, Implanted, Evoked Potentials, Somatosensory, Neural Conduction, Peripheral Nerves, Sensitivity and Specificity, Sensory Thresholds, Models, Animal

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review