Standardisation of bioelectrical impedance analysis for the estimation of body composition in healthy paediatric populations: a systematic review
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Bioelectrical impedance analysis (BIA) requires a high degree of standardisation in order to ensure valid and reproducible impedance measurements. The overall aim of this review was to study the degree to which BIA papers conducted in healthy paediatric populations (aged 0-17 years) were standardised. METHODS: Literature was identified on the basis of a systematic search of internationally-recognised electronic databases and hand searching of the reference lists of the included papers in order to identify additional relevant papers. The review was limited to lead-type BIA devices for whole-body, segmental- and focal impedance measurements. In total, 71 papers published between 1988 and 2016 were included. To evaluate the degree of standardisation of the papers, a recently published review detailing critical factors that may impact on BIA measurements in children was used as a model for structuring and extracting data. RESULTS: There was a general lack of BIA standardisation, or its reporting, in the papers under review, which hinders comparison of data between studies and could potentially lead to erroneous measurements. CONCLUSIONS: If the BIA technique should be accepted clinically for routine use in paediatric populations, there is a need for an increased focus on the importance of improved standardisation and its reporting in future studies. Consequently, this review contains recommendations for performing and reporting BIA measurements in a standardised manner.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1,500 scientists lift the lid on reproducibility
Baker, M. (2016) · Nature · doi:10.1038/533452a · Cited by 4,209
Bioelectrical impedance analysis—part II: utilization in clinical practice
Kyle, U. G., Bosaeus, I., De Lorenzo, A. D., Deurenberg, P., Elia, M., Manuel Gómez, J., Lilienthal Heitmann, B., Kent-Smith, L., Melchior, J.-C., Pirlich, M., et al. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.09.012 · Cited by 2,350 · cited 11×
“The specified time intervals in these papers complied with adult recommendations, however, with regard to the length of time between completion of exercise, and commencement of BIA measurements of minimum four hours [136] or eight hours [1].”
BackgroundMethodInfluentialAssessment of fat-free mass using bioelectrical impedance measurements of the human body
Lukaski, H., Johnson, P., Bolonchuk, W., & Lykken, G. (1985) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/41.4.810 · Cited by 1,896
Validation of tetrapolar bioelectrical impedance method to assess human body composition
Lukaski, H. C., Bolonchuk, W. W., Hall, C. B., & Siders, W. A. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.60.4.1327 · Cited by 1,370
How to write a systematic review
Wright, R. W., Brand, R. A., Dunn, W., & Spindler, K. P. (2007) · Clinical Orthopaedics and Related Research · doi:10.1097/blo.0b013e31802c9098 · Cited by 606 · cited 1×
“[17,18] and, where possible, abided by PRISMA guide-”
Background(1996) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/64.3.524s · Cited by 549
Is the Impedance index (ht2/R) significant in predicting total body water?
Kushner, R., Schoeller, D., Fjeld, C., & Danford, L. (1992) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/56.5.835 · Cited by 374
Why bioelectrical impedance analysis should be used for estimating adiposity.
Houtkooper, L., Lohman, T., Going, S., & Howell, W. (1996) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/64.3.436s · Cited by 361
Houtkooper, L. B., Going, S. B., Lohman, T. G., Roche, A. F., & Van Loan, M. (1992) · Journal of Applied Physiology · doi:10.1152/jappl.1992.72.1.366 · Cited by 348
Validity of bioelectric impedance for body composition assessment in children
Houtkooper, L. B., Lohman, T. G., Going, S. B., & Hall, M. C. (1989) · Journal of Applied Physiology · doi:10.1152/jappl.1989.66.2.814 · Cited by 200 · cited 1×
“5 cm 2 (3%) 58 (82%) [38,80] No data 13 (18%) [5,24,25,32,39,51,60,61,65,69,81–83] Fasting (n1⁄4 71): 2–14 h prior to test 31 (44%) [6,22,25,28,29,31,32,36,37,40,42,43,45,46,52,53,56,57,62–68,71,73,75,78,80,84] No restrictions 9 (13%) 40 (56%) [5,23,41,51,69,72,74,86,88] No data 31 (44%) [20,21,24,27,30,33–35,38,39,44…”
Cited by
Ward, L. C. (2019) · European Journal of Clinical Nutrition · doi:10.1038/s41430-018-0335-3 · Cited by 417
Self-citationCampa, F., Toselli, S., Mazzilli, M., Gobbo, L. A., & Coratella, G. (2021) · Nutrients · doi:10.3390/nu13051620 · Cited by 315
Bioimpedance basics and phase angle fundamentals
Ward, L. C., & Brantlov, S. (2023) · Reviews in Endocrine and Metabolic Disorders · doi:10.1007/s11154-022-09780-3 · Cited by 197
Self-citationSon, J. W., Han, B., Bennett, J. P., Heymsfield, S., & Lim, S. (2025) · Obesity Reviews · doi:10.1111/obr.13844 · Cited by 74
Amaral, M. A., Mundstock, E., Scarpatto, C. H., Cañon-Montañez, W., & Mattiello, R. (2022) · Clinics · doi:10.1016/j.clinsp.2022.100078 · Cited by 14
Metadata
- Authors
- Brantlov, S., Jødal, L., Lange, A., Rittig, S., & Ward, L. C.
- Venue
- Journal of Medical Engineering & Technology
- Publisher
- Informa UK Limited
- Published
- 2017-06-06
- Volume
- 41
- Issue
- 6
- Pages
- 460-479
- ISSN
- 0309-1902 (ISSN-L)
- 1464-522X
- OpenAlex
- W2624455831
- Cited by
- 72
- References
- 18
- FWCI
- 0.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Standardisation of bioelectrical impedance analysis for the estimation of body composition in healthy paediatric populations: a systematic review. https://app.cochat.ai/papers/10.1080/03091902.2017.1333165
- The paper
- Brantlov, S., Jødal, L., Lange, A., Rittig, S., & Ward, L. C. (2017). Standardisation of bioelectrical impedance analysis for the estimation of body composition in healthy paediatric populations: a systematic review. Journal of Medical Engineering & Technology. https://doi.org/10.1080/03091902.2017.1333165
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.