Clinical Applications of Sensors for Human Posture and Movement Analysis: A Review
The DOI matches its Crossref record; 59 of the 59 references it cites were found in a registry or an index.
Abstract
Measurement of human posture and movement is an important area of research in the bioengineering and rehabilitation fields. Various attempts have been initiated for different clinical application goals, such as diagnosis of pathological posture and movements, assessment of pre- and post-treatment efficacy and comparison of different treatment protocols. Image-based methods for measurements of human posture and movements have been developed, such as the photogrammetry, optoelectric technique and video analysis. However, it is found that these methods are complicated to set up, time-consuming to operate and could only be applied in laboratory environments. Electronic sensors and systems with advanced technology, namely accelerometer, gyroscope, flexible angular sensor, electromagnetic tracking system and sensing fabrics, have been developed and applied to solve the relevant application problems of the image-based methods. Nonetheless, other problems for using these electronic sensors emerged, including the environment influence and signal extraction difficulties. Further development of these electronic sensors and measurement methods could enhance their clinical applications in institutional as well as community levels. This article reviews the possible applications of these electronic sensors and systems, and precautions of their applications in analysis of human posture and movement. Such information would help researchers and clinicians in selecting and developing the most appropriate measurement techniques of using the electronic sensors for clinical applications of human posture and movement analysis.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“For historical and practical reasons (size, price, ease of use), conventional accelerometers tend to be the most commonly used sensors [15].”
From Neurological Tremor: Sensors, Signal Processing and Emerging Applications (2010) · cites this paper as [15]
Citations
Cites
Bouten, C. V. C., Koekkoek, K. T. M., Verduin, M., Kodde, R., & Janssen, J. D. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.554760 · Cited by 911 · cited 2×
“The measured acceleration of piezoresistive and capacitive accelerometers consists of two components, including a gravitational component and a component from other acceleration force (Bouten et al. 1997; Mathie et al. 2001; Westbrook 1994).”
BackgroundSpatio-temporal parameters of gait measured by an ambulatory system using miniature gyroscopes
Aminian, K., Najafi, B., Büla, C., Leyvraz, P.-F., & Robert, P. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00008-8 · Cited by 814 · cited 2×
“One type of commercial gyroscope that has been considered for measuring human posture and motion analysis is shown in Figure 4 (Aminian et al. 2002; Sabatini et al. 2005).”
BackgroundMethodAssessment of Walking Features From Foot Inertial Sensing
Sabatini, A. M., Martelloni, C., Scapellato, S., & Cavallo, F. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.840727 · Cited by 650 · cited 2×
“Sabatini et al. (2005) used the combined sensing unit affixed to the foot instep to estimate spatio-temporal gait parameters.”
MethodDetection of static and dynamic activities using uniaxial accelerometers
Veltink, P. H., Bussmann, H. J., de Vries, W., Martens, W. J., & Van Lummel, R. C. (1996) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.547939 · Cited by 491 · cited 1×
“The static and dynamic activities could be discriminated, and the postures and the orientations of body segments could also be detected (Bouten et al. 1997; Fahrenberg et al. 1997; Foerster et al. 1999; Lyons et al. 2005; Mathie et al. 2001; Veltink et al. 1993; 1996).”
BackgroundDetection of posture and motion by accelerometry: a validation study in ambulatory monitoring
Foerster, F., Smeja, M., & Fahrenberg, J. (1999) · Computers in Human Behavior · doi:10.1016/s0747-5632(99)00037-0 · Cited by 480 · cited 1×
“The static and dynamic activities could be discriminated, and the postures and the orientations of body segments could also be detected (Bouten et al. 1997; Fahrenberg et al. 1997; Foerster et al. 1999; Lyons et al. 2005; Mathie et al. 2001; Veltink et al. 1993; 1996).”
BackgroundA practical gait analysis system using gyroscopes
Tong, K., & Granat, M. H. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00030-2 · Cited by 460
Accelerometry—A technique for the measurement of human body movements
Morris, J. R. W. (1973) · Journal of Biomechanics · doi:10.1016/0021-9290(73)90029-8 · Cited by 325 · cited 1×
“Thus, careful site selection and appropriate form of fixation of the sensor is very important for measurements (Mathie et al. 2001; Morris 1973).”
BackgroundRelations Between Standing Stability and Body Posture Parameters in Adolescent Idiopathic Scoliosis
Nault, M.-L., Allard, P., Hinse, S., Le Blanc, R., Caron, O., Labelle, H., & Sadeghi, H. (2002) · Spine · doi:10.1097/00007632-200209010-00018 · Cited by 285 · cited 2×
“1995), and video analysis (Robinson et al. 1993; Masso and Gorton 2000; Nault et al. 2002; Engsberg et al. 2003).”
BackgroundWearable sensor badge and sensor jacket for context awareness
Farringdon, J., Moore, A. J., Tilbury, N., Church, J., & Biemond, P. D. (2003) · Digest of Papers. Third International Symposium on Wearable Computers · doi:10.1109/iswc.1999.806681 · Cited by 239 · cited 1×
“It gives a linearly increasing asymptotic resistance when it is stretched, up to almost maximum stretch (Farringdon et al. 1999).”
BackgroundA description of an accelerometer-based mobility monitoring technique
Lyons, G. M., Culhane, K. M., Hilton, D., Grace, P. A., & Lyons, D. (2005) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2004.11.006 · Cited by 218 · cited 1×
“The static and dynamic activities could be discriminated, and the postures and the orientations of body segments could also be detected (Bouten et al. 1997; Fahrenberg et al. 1997; Foerster et al. 1999; Lyons et al. 2005; Mathie et al. 2001; Veltink et al. 1993; 1996).”
Background
Research works printed but not linked: 1
- Weissman, 1968, Anthropometric photogrammetry, Photogrammetr Engin, 34, 1134
Cited by
Items 101–200 of 210
Olsen, G. F., Brilliant, S. S., Primeaux, D., & Najarian, K. (2009) · ICME International Conference on Complex Medical Engineering (CME) · doi:10.1109/iccme.2009.4906675 · Cited by 8
Biomechanical assessment of head and neck movements in neck pain using 3D movement analysis
Grip, H. (2008) · DiVA at Umeå University (Umeå University) · Cited by 10
Development of a wearable mobility monitoring system
Hache, G. (2010) · uO Research (University of Ottawa) · doi:10.20381/ruor-19306 · Cited by 9
“[107] presented five sensor classes in their review: 1) accelerometers, 2) gyroscopes, 3) flexible angular sensor, 4) electromagnetic tracking systems, and 5) sensing fabrics, with accelerometers being the most commonly used.”
BackgroundRoldán‐Jiménez, C., Vargas, A. I. C., & Martín‐Martín, J. (2022) · Sensors · doi:10.3390/s22083081 · Cited by 7
Šarabon, N. (2011) · Hrčak Portal of scientific journals of Croatia (University Computing Centre) · Cited by 7
Sharif-human movement instrumentation system (SHARIF-HMIS) for daily activities
Esfahani, M. I. M., Zobeiri, O. A., Akbari, A., Milani, Y., Narimani, R., Moshiri, B., & Parnianpour, M. (2012) · National and International Iranian Conference on Biomedical Engineering (ICBME) · doi:10.1109/icbme.2012.6519674 · Cited by 7
Evaluation of trunk acceleration in healthy individuals and those with low back pain
Aluko, A., DeSouza, L., & Peacock, J. L. (2011) · International Journal of Therapy and Rehabilitation · doi:10.12968/ijtr.2011.18.1.18 · Cited by 7
Advanced classification of ambulatory activities using spectral density distances and heart rate
Rahman, H. A., Ge, D., Faucheur, A. L., Prioux, J., & Carrault, G. (2017) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2016.12.018 · Cited by 9
A reliability study of the new sensors for movement analysis (SHARIF–HMIS)
Abedi, M., Manshadi, F. D., Zavieh, M. K., Ashouri, S., Azimi, H., & Parnanpour, M. (2015) · Journal of Bodywork and Movement Therapies · doi:10.1016/j.jbmt.2015.10.004 · Cited by 7
“Wearable measuring systems have extensively been used in biomedical engineering (Wong et al., 2007).”
BackgroundComparison of Spinal Angles in a Typing Task on a Laptop and a Desktop Computer: A Preliminary Study
Alyami, H. H., & Albarrati, A. (2016) · American Journal of Occupational Therapy · doi:10.5014/ajot.2016.020743 · Cited by 7
“Various methods are available for analyzing posture, including radiographs, sensors, subjective measures, and digital photogrammetry (Bridger, 2003; Corlett, 2005; Wong & Wong, 2008; Wong, Wong, & Lo, 2007).”
Sensor Classifications and Their Applications in IoT Systems
Sajja, K. S., & Bhowmik, B. R. (2023) · IEEE International Conference on Distributed Computing, VLSI, Electrical Circuits and Robotics (DISCOVER) · doi:10.1109/discover58830.2023.10316731 · Cited by 9
Addressing the Problem of Activity Recognition with Experience Sampling and Weak Learning
Duffy, W., Curran, K., Kelly, D., & Lunney, T. (2018) · Advances in intelligent systems and computing · doi:10.1007/978-3-030-01054-6_86 · Cited by 7
Review of new developments in different types of sensors over the past 15 years
Ador, M. S. H., Bhattacharjee, P., Kabir, S., Pranto, M. T. A., Ahmed, F., & Choudhury, I. A. (2023) · Elsevier eBooks · doi:10.1016/b978-0-323-96020-5.00043-1 · Cited by 6
Studying Upper-Limb Kinematics Using Inertial Sensors Embedded in Mobile Phones
Roldán‐Jiménez, C., Vargas, A. I. C., & Bennett, P. J. (2015) · JMIR Rehabilitation and Assistive Technologies · doi:10.2196/rehab.4101 · Cited by 6
“In addition, their operational feasibility in various clinical applications has been studied [34].”
BackgroundO'Hara, K. P., Morrison, C. P., Sellen, A. J., Bianchi‐Berthouze, N., & Craig, C. (2016) · Synthesis lectures on assistive, rehabilitative, and health-preserving technologies · doi:10.1007/978-3-031-01600-4 · Cited by 8
O'Hara, K. P., Morrison, C. P., Sellen, A. J., Bianchi‐Berthouze, N., & Craig, C. (2016) · Synthesis lectures on assistive, rehabilitative, and health-preserving technologies · doi:10.2200/s00702ed1v01y201602arh009 · Cited by 6
Towards User-Friendly Wearable Platforms for Monitoring Unconstrained Indoor and Outdoor Activities
Rezaei, A., Khoshnam, M., & Menon, C. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2020.3004319 · Cited by 6
“While the accuracy of visual-based systems has made them the gold standard of motion tracking platforms, limitations such as lengthy setup time, need of unobstructed line of sight, sophisticated hardware, and limited capture space limit their usage to controlled and well-instrumented environments such as clinics [1],…”
BackgroundInfluentialClinical application of gait analysis in hip arthroplasty
Zhao, S., Chen, Y., & Zhang, X. (2010) · Orthopaedic Surgery · doi:10.1111/j.1757-7861.2010.00070.x · Cited by 6
Sawaryn, B., Klaassen, M., van Beijnum, B.-J. F., Zwart, H. J., & Veltink, P. H. (2021) · Sensors · doi:10.3390/s21175954 · Cited by 6
Correlation between body composition variables and plantar pressure and pain level
Dikhtyarenko, S., Forte, P. M., & Esteves, D. (2024) · Acta of Bioengineering and Biomechanics · doi:10.37190/abb-02437-2024-03 · Cited by 6
Progress of protective gear in preventing sports injuries
Choudhury, R. D., Assumi, K. H., Nath, D., Kalai, S., & Nath, S. C. (2024) · Brazilian Journal of Development · doi:10.34117/bjdv10n3-012 · Cited by 5
An Advanced Hybrid Technique of DCS and JSRC for Telemonitoring of Multi-Sensor Gait Pattern
Wu, J., Wang, J., Ling, Y., & Xu, H. (2017) · Sensors · doi:10.3390/s17122764 · Cited by 6
Wu, Q., Yang, R., Liu, K., Xu, Y., Miao, J., & Sun, M. (2024) · Electronics · doi:10.3390/electronics13153027 · Cited by 5
Vargas, A. I. C., & William, J. (2011) · Fisioterapia · doi:10.1016/j.ft.2010.12.005 · Cited by 5
Dai, X., Zhou, Z., Zhang, J. J., & Davidson, B. S. (2014) · Asilomar Conference on Signals, Systems and Computers (ACSSC) · doi:10.1109/acssc.2014.7094768 · Cited by 5
“Combining (1), (2) and (3), our tracking problem can be formulated as”
BackgroundMiller, K. T., Russell, M., Jenks, T., Surratt, K., Poretti, K., Eigenbrot, S., Akins, J. S., & Major, M. J. (2020) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/jpo.0000000000000332 · Cited by 5
Lieberz, D., Borstad, A. L., & Nelson, J. (2023) · Disability and Rehabilitation · doi:10.1080/09638288.2023.2237893 · Cited by 6
“The measurement of human movement is a critical area of rehabilitation research [13], but is limited by the accessibility of costly and technical equipment [14].”
BackgroundLi, M., Zheng, L., Xu, T., Wo, H., Farooq, U., Tan, W., Bao, C., Wang, X., Dong, S., Guo, W., et al. (2018) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2018.06.023 · Cited by 4
Flexible Wearable Nanomaterial-Based Sensing Device for Back Pain and Injury Prevention
Jacobs, E., Rosen, A., Berg‐Johansen, B., & Wang, L. (2023) · IEEE Sensors Letters · doi:10.1109/lsens.2023.3272650 · Cited by 4
“, rigid/bulky configurations and indirect low back monitoring) [5], [6], we have developed a highly flexible wearable sensing device (i.”
BackgroundMizuno, K., Shiba, Y., Sato, H., Kamide, N., Fukuda, M., & Ikeda, N. (2013) · Journal of Physical Therapy Science · doi:10.1589/jpts.25.97 · Cited by 4
Paloschi, D., Bravi, M., Miccinilli, S., Schena, E., Sterzi, S., Massaroni, C., & Saccomandi, P. (2021) · IEEE International Workshop on Metrology for Industry 4.0 & IoT (MetroInd4.0&IoT) · doi:10.1109/metroind4.0iot51437.2021.9488521 · Cited by 4
Advancing Applications of IMUs in Sports Training and Biomechanics.
McGinnis, R. S. (2013) · Deep Blue (University of Michigan) · Cited by 4
Ultrasound monitoring of inter-knee distances during gait
Lai, D. T. H., Wrigley, T. V., & Palaniswami, M. S. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5332907 · Cited by 3
Promvichai, S., Kaewjua, K., Meoipun, A., Chotsuwan, C., Chailapakul, O., & Siangproh, W. (2023) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/acd725 · Cited by 3
Machine Learning for Individual Performance Analysis and Sports Analytics
Chhabra, G., Kumar, S., Gupta, S. K., & Nagpal, P. (2023) · Springer eBooks · doi:10.1007/978-981-99-3039-5_10 · Cited by 3
Full Body Wearable Instrumented Motion Analysis System
Chong, Y. Z. (2009) · International Conference on Bioinformatics and Biomedical Engineering · doi:10.1109/icbbe.2009.5162869 · Cited by 4
“This will provide real-live motion analysis of human movements in different environment from complex maneuvers such as in sports to clinical to telehealth assessments [6] – [8], [10] [12].”
BackgroundMethodAn investigation into smartphone based weakly supervised activity recognition systems
Duffy, W., Curran, K., Kelly, D., & Lunney, T. (2019) · Pervasive and Mobile Computing · doi:10.1016/j.pmcj.2019.03.005 · Cited by 4
“This is both due to the complexities regarding setup of data collection experiments [8] and ensuring that annotations collected are sufficient and accurate.”
BackgroundMorino, S., Yamashita, M., Umezaki, F., Hatanaka, H., & Takahashi, M. (2020) · Applied Sciences · doi:10.3390/app10113690 · Cited by 3
“Clinical motion analysis typically employs visual observation as the dominant means of assessment; however, more quantitative and objective motion assessments are required to obtain meaningful results [9].”
BackgroundRecognition and classification of human activities using wearable sensors
Yurtman, A. (2012) · Bilkent University Institutional Repository (Bilkent University) · doi:10.13140/rg.2.2.34665.39523 · Cited by 5
Iurato, M., Dondero, P., Job, M., Stanzani, R., Leuzzi, G., Ingegnosi, I., & Testa, M. (2025) · Frontiers in Digital Health · doi:10.3389/fdgth.2025.1576031 · Cited by 2
“However, traditional movement analysis techniques such as photogrammetry, optoelectronic analysis and video analysis, require complex and expensive instrumentation (36).”
Mazzoleni, S., Battini, E., Galgani, M., Tenucci, M., Dario, P., & Calvosa, G. (2018) · The Open Biomedical Engineering Journal · doi:10.2174/1874120701812010135 · Cited by 2
On the development of a wireless motion capture sensor node for upper limb rehabilitation
Tsilomitrou, O., Γκούντας, Κ., Evangeliou, N., & Dermatas, E. (2019) · International Conference on Control, Decision and Information Technologies (CoDIT) · doi:10.1109/codit.2019.8820559 · Cited by 2
“To avoid such problems, sensors have been used for motion tracking [6].”
MethodButler, L., Olander, H. L., Erdman, A. L., & Ulman, S. M. (2025) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2025.106485 · Cited by 2
Development of a measuring system for shoulder abduction and adduction
Esfahani, M. I. M., Soroush, A., Narimani, R., Talab, M. H., & Parnianpour, M. (2010) · National and International Iranian Conference on Biomedical Engineering (ICBME) · doi:10.1109/icbme.2010.5704989 · Cited by 2
“[10-15]”
Aydın, İ., & Aşıcı, B. (2020) · Fırat Üniversitesi Mühendislik Bilimleri Dergisi · doi:10.35234/fumbd.671403 · Cited by 3
Designing smart garments for rehabilitation
Wang, Q. (2018) · TU/e Research Portal · Cited by 3
Characterisation of knitted conductive textiles for wearable motion sensor applications
Isaia, C. (2018) · Nottingham ePrints (University of Nottingham) · Cited by 3
Intelligent sensing for robot mapping and simultaneous human localization and activity recognition
Altun, K. (2011) · Bilkent University Institutional Repository (Bilkent University) · Cited by 2
A modular machine learning tool for holistic and fine-grained behavioral analysis
Michelot, B., Corneyllie, A., Thévenet, M., Duffner, S., & Perrin, F. (2024) · Behavior Research Methods · doi:10.3758/s13428-024-02511-3 · Cited by 1
“…devices (i.e., a single camera) compared to commonly used methods such as eye-tracking (Carter & Luke, 2020; Stein et al., 2021) or accelerometry systems (Preece et al., 2009; Wong et al., 2007), making them particularly advantageous for capturing behaviors unconstrained by experimental setups.”
Igwesi-Chidobe, C. N., Anih, E. U., Emmanuel, G. N., & Ozumba, B. C. (2025) · F1000Research · doi:10.12688/f1000research.160172.2 · Cited by 1
Yoshida, T., Uehara, S., Hirano, A., Itoh, S., & Otaka, Y. (2025) · Scientific Reports · doi:10.1038/s41598-025-25640-x · Cited by 1
BEZPRZEWODOWY CZUJNIK AKTYWNOŚCI FIZYCZNEJ BAZUJĄCY NA PROCESORZE O NISKIM POBORZE MOCY
Borowiec, R., & Surtel, W. (2015) · Informatyka Automatyka Pomiary w Gospodarce i Ochronie Środowiska · doi:10.5604/20830157.1176570 · Cited by 1
Study of Temperature Decoupling Fiber Acceleration Sensor Based on the Dual-FP Structure
Xie, H. H., Jiang, X. F., Yan, H. P., & Huang, Y. Q. (2012) · Applied Mechanics and Materials · doi:10.4028/www.scientific.net/amm.201-202.226 · Cited by 1
Single axis stabilometric platform: Reliability of measures by comparison with a gold standard
Cattaneo, D., Jonsdottir, J., & Rabuffetti, M. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2007.12.062 · Cited by 1
Classification of leg motions by processing gyroscope signals
Tunçel, O., Altun, K., & Barshan, B. (2009) · Signal Processing and Communications Applications Conference (SIU) · doi:10.1109/siu.2009.5136404 · Cited by 1
“Bu uygulamalar ile ilgili olarak [2, 3, 4] makalelerinde geniş literatür taramalarına ulaşılabilir.”
Wang, L., Silva, L., Rosa, M. D., Marques, C. J., Barreiros, J., & Cabri, J. (2017) · Journal of Functional Morphology and Kinesiology · doi:10.3390/jfmk2010007 · Cited by 1
“Often, force plates and/or electromyography can be combined to provide complete information [1].”
BackgroundDetection of the Trench Depth Based on a Differential Inertial Sensor Technology
Wang, X., Peng, B., Miedziński, B., Hu, B., & Xu, M. (2018) · Elektronika ir Elektrotechnika · doi:10.5755/j01.eie.24.3.20973 · Cited by 1
Reliability of a Novel Video-Based Method for Assessing Age-Related Changes in Upper Limb Kinematics
Pupo, D. A., Kakareka, J. W., Krynitsky, J., Leggio, L., Pohida, T., Studenski, S. A., & Harvey, B. K. (2018) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2018.00281 · Cited by 1
The Torque Control and Evaluation of the Ankle Prosthesis
Xu, S., Pang, M., Tang, B., & Xiang, K. (2018) · IEEE International Conference on Information and Automation (ICIA) · doi:10.1109/icinfa.2018.8812355 · Cited by 1
“For examples, the foot switch sensor is used to determine the current gait [15]; the encoder is applied to read the current ankle angle; and the tension sensor is implemented to obtain the current torque.”
MethodA Development of Smart Device-based Motion Measurement System
Arisaka, N., Mizuno, K., Mamorita, N., Shiba, Y., Shimizu, S., Matsunaga, A., & Tsuruta, H. (2017) · IEEJ Transactions on Electronics Information and Systems · doi:10.1541/ieejeiss.137.634 · Cited by 1
Taşar, B. (2021) · Yüzüncü Yıl Üniversitesi Fen Bilimleri Enstitüsü Dergisi · doi:10.53433/yyufbed.931553 · Cited by 1
Pardhu, T., Kumar, V., Kanavos, A., Gerogiannis, V. C., & Acharya, B. (2024) · Mathematics · doi:10.3390/math12152314 · Cited by 1
“Sensors that measure human motion, gait, and posture are essential tools in these fields, offering critical data that can guide technology development and implementation [3].”
Development and Assessment of Smart Textile Systems for Human Activity Classification
Esfahani, M., & Iman, M. R. H. (2018) · VTechWorks (Virginia Tech) · Cited by 3
Optimization of passive cantilever-type tuned mass damper to reduce the hand postural tremor
Gebai, S. (2020) · theses.fr (ABES) · doi:10.70675/994e0848ze136z4e48z8db8z9981215dcb5b · Cited by 6
Power, V. (2014) · University of Limerick Institutional Repository (University of Limerick) · doi:10.34961/7848
Évaluation fonctionnelle cinématique après chirurgie de l’épaule
Pichonnaz, C., Martin, E., Bassin, J., Duc, C., Farron, A., Aminian, K., Jolles, B. M., & Gleeson, N. (2011) · Kinésithérapie la Revue · doi:10.1016/s1779-0123(11)75053-7
A PROTOTYPE SYSTEM TO MEASURE THE TRUNK ANGLE IN SAGITAL PLANE
Esfahani, M. I. M., Ramezanzadeh, M., Narimani, R., & Soroush, A. (2010) · Biomedical Engineering · doi:10.2316/p.2010.723-169
“In recent years, many advanced and cheap sensors have been design to compensate the problems of video based methods [10-16].”
BackgroundExamining the role of sitting behaviour in non-specific chronic low back pain
O’Sullivan, K. (2012) · Arrow@dit (Dublin Institute of Technology) · Cited by 1
Smart Lab Coat for the Smart Lab Coat for the Dental Practitioner Dental Practitioner
Olsen, G. F., Brilliant, S. S., & Primeaux, D. (2007)
Tunçel, O., Altun, K., & Barshan, B. (2009)
Ultra-wideband Radar Based Human Motion Analysis
Zhou, Z. (2016) · Digital Commons - DU (University of Denver) · Cited by 1
Trunk postural demands of physical occupational activities for women in Benin
Beaucage‐Gauvreau, E. (2010) · QSpace (Queen's University Library) · Cited by 1
Assis, A. S. M. D. C. R. (2016) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) · doi:10.34626/happ-8562 · Cited by 1
Estudio de la cinemática del miembro superior e inferior mediante sensores inerciales.
Jiménez, C. R. (2017) · Repositorio Institucional de la Universidad de Málaga (University of Málaga) · Cited by 4
User-trained activity recognition using smartphones and weak supervision
Duffy, W., Curran, K., Kelly, D., & Lunney, T. (2019) · Irish Signals and Systems Conference · doi:10.1109/issc.2019.8904948
Pichonnaz, C. (2019) · ArODES (HES-SO (https://www.hes-so.ch/))
Postural symmetry evaluation using phase approximations of the follow-up CoP trajectories
Łukaszewicz, T., Kidoń, Z., Kania, D., & Pethe-Kania, K. (2020) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2020.1810241
“Worth consideration are also the so-called sensing fabrics which can be integrated with pieces of clothing, enabling observation of movement of certain body parts (De Rossi et al. 2000; Scilingo et al. 2003; Wong et al. 2007).”
BackgroundInfluentialBarthélemy, A. (2019) · KTH Publication Database DiVA (KTH Royal Institute of Technology)
Coyle-Asbil, H. J. (2021) · The Atrium (University of Guelph) · Cited by 1
Lab-on-a-chip: wearables as a one stop shop for free-living assessments
Morris, R., & Mancin, M. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-818914-6.00017-x
Grimaldi, G., & Manto, M. U. (2008) · Synthesis lectures on biomedical engineering · doi:10.1007/978-3-031-01627-1_6
Smart Devices in Healthcare Sector: Applications
Sharma, K., Kesharwani, P., Prajapati, S. K., Jain, A., Mittal, N., Kaushik, R., & Mody, N. (2022) · Springer eBooks · doi:10.1007/978-3-030-84205-5_23 · Cited by 1
Analysis on Wireless Technologies and Application of Sensors in the Agriculture Sector
Nidhya, M. S., & Akhila, P. (2024) · Advances in environmental engineering and green technologies book series · doi:10.4018/979-8-3693-2069-3.ch027
Behavioral and Neural Dynamics of Fear Extinction
Pompili, M. N. (2019) · theses.fr (ABES) · doi:10.70675/28612ebdz0842z4512z913ez931e4e350562
Fernández, D. A., Rodas, C. F. R., Rodríguez, P. E. C., Guevara, N. E., Sierra, W., & Rodríguez, L. E. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4870002
Fernández, D. A., Rodas, C. F. R., & Rodríguez, P. E. C. (2024) · Entre ciencia e ingeniería · doi:10.31908/19098367.2982
Dennis, J. C., Raksana, B., Rakshita, T. S., & Poonghuzhali, S. (2025) · International Conference on Bio Signals, Images, and Instrumentation (ICBSII) · doi:10.1109/icbsii65145.2025.11013427
“Previous studies have introduced posture monitoring systems utilizing load cells mounted on a seat plate to measure distinct sitting postures based on load distribution [1].”
Digital Innovation for Individual Approach to Incorrect Spine Posture in Adolescents “NOVA-SPINE”
Pontillo, G., Catalano, C., Andreozzi, V., Maresca, L., & Liguori, S. (2025) · Lecture notes of the Institute for Computer Sciences, Social Informatics and Telecommunications Engineering · doi:10.1007/978-3-031-95571-6_3
Fernández, D. A., Rodas, C. F. R., Rodríguez, P. E. C., Guevara, N. E., Sierra, W., & Rodríguez, L. E. (2025) · SSRN Electronic Journal · doi:10.2139/ssrn.5343088
Biomechanical Posture Analysis
Karacif, D., & Türk, A. Ç. (2025) · Springer eBooks · doi:10.1007/978-3-031-90347-2_50-1
Biomechanical Posture Analysis
Karacif, D., & Türk, A. Ç. (2025) · Springer eBooks · doi:10.1007/978-3-032-06268-0_50
Motion Capture: From Radio Signals to Inertial Signals
Giuberti, M., & Ferrari, G. (2015) · Springer series in bio-/neuroinformatics · doi:10.1007/978-3-319-12817-7_34
“Gianluigi Ferrari Department of Information Engineering University of Parma Parma, Italy e-mail: gianluigi.ferrari@unipr.it 1”
BackgroundProposta de um sistema de avaliação automática para treinamentos simulados de agentes de segurança
de Armas, C., Netto, A. V., & Tori, R. (2024) · Revista Eletrônica Argentina-Brasil de Tecnologias da Informação e da Comunicação · doi:10.5281/zenodo.14257283
Bessa, D. P. T. (2018) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT)
Možnosti ovlivnění posturální stability seniorů tradičním čínským cvičením Čchi - Kung
Krausová, A. (2020) · Digital Library (University of West Bohemia)
Krumm, D. (2019) · Qucosa - Monarch (Chemnitz University of Technology) · Cited by 1
Elemam, R. S., Abdelmegeed, M. A., Soliman, E. S., Soliman, M. O., & Abdelkader, N. A. (2025) · SPORT TK-Revista EuroAmericana de Ciencias del Deporte · doi:10.6018/sportk.695341
Predicting Energy Expenditure in Preschool Children Using Accelerometer and Gyroscope Data
Coyle-Asbil, H. J., Osojnicki, K., Robertson, A. A., Baker, R. E., Grigore, M. M., Burr, J. F., Buck, C., Wright, M. N., & Vallis, L. A. (2026) · Pediatric Exercise Science · doi:10.1123/pes.2025-0014
Grumillier, C. (2008) · theses.fr (ABES) · doi:10.70675/b9d467cdz53dcz446czaa4ezae35ba049523 · Cited by 3
Metadata
- Authors
- Wong, W. Y., Wong, M. S., & Lo, K. H.
- Affiliations
- Hong Kong Polytechnic University (HK)
- ORCID
- Wong, Man Sang
- Venue
- Prosthetics & Orthotics International
- Published
- 2007-03
- Volume
- 31
- Issue
- 1
- Pages
- 62-75
- ISSN
- 0309-3646 (ISSN-L)
- OpenAlex
- W2115115183
- Cited by
- 193
- References
- 59
- Citations by year
- 2026: 3 · 2025: 10 · 2024: 10 · 2023: 10 · 2022: 8 · 2021: 15 · 2020: 12 · 2019: 8 · 2018: 17 · 2017: 10 · 2016: 11 · 2015: 13 · 2014: 10 · 2013: 12 · 2012: 6
- FWCI
- 2.49
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Prosthetics and Orthotics International (publishedVersion)
- PubMed (publishedVersion)
- PolyU Institutional Research Archive (Hong Kong Polytechnic University) (submittedVersion)
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Balance, Gait, and Falls Prevention
- Social Sciences › Human Factors and Ergonomics › Ergonomics and Musculoskeletal Disorders
- Keywords
- human motion analysis, electronic sensors, accelerometer, gyroscope, electromagnetic tracking, rehabilitation assessment, clinical application, signal extraction, environmental interference
- MeSH terms
- Biomechanical Phenomena, Biomedical Engineering, Electronics, Medical, Environment, Gait, Humans, Movement, Posture, Rehabilitation, Upper Extremity, Electromagnetic Phenomena
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.