Clinical Applications of Sensors for Human Posture and Movement Analysis: A Review
The DOI matches its Crossref record; 59 of the 59 references it cites were found in a registry or an index.
Abstract
Measurement of human posture and movement is an important area of research in the bioengineering and rehabilitation fields. Various attempts have been initiated for different clinical application goals, such as diagnosis of pathological posture and movements, assessment of pre- and post-treatment efficacy and comparison of different treatment protocols. Image-based methods for measurements of human posture and movements have been developed, such as the photogrammetry, optoelectric technique and video analysis. However, it is found that these methods are complicated to set up, time-consuming to operate and could only be applied in laboratory environments. Electronic sensors and systems with advanced technology, namely accelerometer, gyroscope, flexible angular sensor, electromagnetic tracking system and sensing fabrics, have been developed and applied to solve the relevant application problems of the image-based methods. Nonetheless, other problems for using these electronic sensors emerged, including the environment influence and signal extraction difficulties. Further development of these electronic sensors and measurement methods could enhance their clinical applications in institutional as well as community levels. This article reviews the possible applications of these electronic sensors and systems, and precautions of their applications in analysis of human posture and movement. Such information would help researchers and clinicians in selecting and developing the most appropriate measurement techniques of using the electronic sensors for clinical applications of human posture and movement analysis.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“For historical and practical reasons (size, price, ease of use), conventional accelerometers tend to be the most commonly used sensors [15].”
From Neurological Tremor: Sensors, Signal Processing and Emerging Applications (2010) · cites this paper as [15]
Citations
Cites
Bouten, C. V. C., Koekkoek, K. T. M., Verduin, M., Kodde, R., & Janssen, J. D. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.554760 · Cited by 911 · cited 2×
“The measured acceleration of piezoresistive and capacitive accelerometers consists of two components, including a gravitational component and a component from other acceleration force (Bouten et al. 1997; Mathie et al. 2001; Westbrook 1994).”
BackgroundSpatio-temporal parameters of gait measured by an ambulatory system using miniature gyroscopes
Aminian, K., Najafi, B., Büla, C., Leyvraz, P.-F., & Robert, P. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00008-8 · Cited by 814 · cited 2×
“One type of commercial gyroscope that has been considered for measuring human posture and motion analysis is shown in Figure 4 (Aminian et al. 2002; Sabatini et al. 2005).”
BackgroundMethodAssessment of Walking Features From Foot Inertial Sensing
Sabatini, A. M., Martelloni, C., Scapellato, S., & Cavallo, F. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.840727 · Cited by 650 · cited 2×
“Sabatini et al. (2005) used the combined sensing unit affixed to the foot instep to estimate spatio-temporal gait parameters.”
MethodDetection of static and dynamic activities using uniaxial accelerometers
Veltink, P. H., Bussmann, H. J., de Vries, W., Martens, W. J., & Van Lummel, R. C. (1996) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.547939 · Cited by 491 · cited 1×
“The static and dynamic activities could be discriminated, and the postures and the orientations of body segments could also be detected (Bouten et al. 1997; Fahrenberg et al. 1997; Foerster et al. 1999; Lyons et al. 2005; Mathie et al. 2001; Veltink et al. 1993; 1996).”
BackgroundDetection of posture and motion by accelerometry: a validation study in ambulatory monitoring
Foerster, F., Smeja, M., & Fahrenberg, J. (1999) · Computers in Human Behavior · doi:10.1016/s0747-5632(99)00037-0 · Cited by 480 · cited 1×
“The static and dynamic activities could be discriminated, and the postures and the orientations of body segments could also be detected (Bouten et al. 1997; Fahrenberg et al. 1997; Foerster et al. 1999; Lyons et al. 2005; Mathie et al. 2001; Veltink et al. 1993; 1996).”
BackgroundA practical gait analysis system using gyroscopes
Tong, K., & Granat, M. H. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00030-2 · Cited by 460
Accelerometry—A technique for the measurement of human body movements
Morris, J. R. W. (1973) · Journal of Biomechanics · doi:10.1016/0021-9290(73)90029-8 · Cited by 325 · cited 1×
“Thus, careful site selection and appropriate form of fixation of the sensor is very important for measurements (Mathie et al. 2001; Morris 1973).”
BackgroundRelations Between Standing Stability and Body Posture Parameters in Adolescent Idiopathic Scoliosis
Nault, M.-L., Allard, P., Hinse, S., Le Blanc, R., Caron, O., Labelle, H., & Sadeghi, H. (2002) · Spine · doi:10.1097/00007632-200209010-00018 · Cited by 285 · cited 2×
“1995), and video analysis (Robinson et al. 1993; Masso and Gorton 2000; Nault et al. 2002; Engsberg et al. 2003).”
BackgroundWearable sensor badge and sensor jacket for context awareness
Farringdon, J., Moore, A. J., Tilbury, N., Church, J., & Biemond, P. D. (2003) · Digest of Papers. Third International Symposium on Wearable Computers · doi:10.1109/iswc.1999.806681 · Cited by 239 · cited 1×
“It gives a linearly increasing asymptotic resistance when it is stretched, up to almost maximum stretch (Farringdon et al. 1999).”
BackgroundA description of an accelerometer-based mobility monitoring technique
Lyons, G. M., Culhane, K. M., Hilton, D., Grace, P. A., & Lyons, D. (2005) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2004.11.006 · Cited by 218 · cited 1×
“The static and dynamic activities could be discriminated, and the postures and the orientations of body segments could also be detected (Bouten et al. 1997; Fahrenberg et al. 1997; Foerster et al. 1999; Lyons et al. 2005; Mathie et al. 2001; Veltink et al. 1993; 1996).”
BackgroundValidity and reliability of triaxial accelerometers for inclinometry in posture analysis
Hansson, G., Asterland, P., Holmer, N. G., & Skerfving, S. (2001) · Medical and Biological Engineering and Computing · doi:10.1007/bf02345361 · Cited by 201 · cited 2×
“Hansson et al. (2001) found that the angular error of a tri-axial accelerometer system is 1.38, the reproducibility is 0.28, and the inherent angular noise is 0.048 and its operation is independent of the orientation of the device.”
BackgroundInfluentialMicrosensors: principles and applications
(1995) · Choice Reviews Online · doi:10.5860/choice.32-3328 · Cited by 200
Strain-sensing fabrics for wearable kinaesthetic-like systems
Scilingo, E. P., Lorussi, F., Mazzoldi, A., & De Rossi, D. (2003) · IEEE Sensors Journal · doi:10.1109/jsen.2003.815771 · Cited by 200 · cited 2×
“In the case of sensing fabric, its signals could be affected by humidity and temperature (Scilingo et al. 2003).”
BackgroundFinley, M. A., & Lee, R. Y. (2003) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2003.50087 · Cited by 197
New method for the non-invasive three-dimensional measurement of human back movement
Pearcy, M. J., & Hindle, R. J. (1989) · Clinical Biomechanics · doi:10.1016/0268-0033(89)90042-9 · Cited by 192 · cited 2×
“…with similar design are commercially available for kinematics studies in movements in different body segments, including upper limbs (Finley and Lee 2003; Ramanathan et al. 2000) and spine (Bull and McGregor 2000; Lee 2001; Mannion and Troke 1999; Pearcy and Hindle 1989; Willems et al. 1996).”
MethodAn in vivo study of the primary and coupled rotations of the thoracic spine
Willems, J., Jull, G. A., & Ng, J. K. F. (1996) · Clinical Biomechanics · doi:10.1016/0268-0033(96)00017-4 · Cited by 153 · cited 2×
“…with similar design are commercially available for kinematics studies in movements in different body segments, including upper limbs (Finley and Lee 2003; Ramanathan et al. 2000) and spine (Bull and McGregor 2000; Lee 2001; Mannion and Troke 1999; Pearcy and Hindle 1989; Willems et al. 1996).”
MethodAssessment of posture and motion by multichannel piezoresistive accelerometer recordings
FAHRENBERG, J., FOERSTER, F., SMEJA, M., & MÜLLER, W. (1997) · Psychophysiology · doi:10.1111/j.1469-8986.1997.tb01747.x · Cited by 141 · cited 1×
“The static and dynamic activities could be discriminated, and the postures and the orientations of body segments could also be detected (Bouten et al. 1997; Fahrenberg et al. 1997; Foerster et al. 1999; Lyons et al. 2005; Mathie et al. 2001; Veltink et al. 1993; 1996).”
BackgroundA system for monitoring posture and physical activity using accelerometers
Mathie, M. J., Basilakis, J., & Celler, B. G. (2005) · 2001 Conference Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2001.1019627 · Cited by 126
A Database for Estimating Normal Spinal Motion Derived From Noninvasive Measurements
Gracovetsky, S., Newman, N., Pawlowsky, M., Lanzo, V., Davey, B., & Robinson, L. (1995) · Spine · doi:10.1097/00007632-199505000-00010 · Cited by 120 · cited 2×
“2001), optoelectric analysis (Pearcy et al. 1987; Dawson et al. 1993; Gracovetsky et al. 1995), and video analysis (Robinson et al.”
BackgroundMethodEstimating orientation with gyroscopes and accelerometers
Luinge, H. J., Veltink, P. H., & Baten, C. T. M. (1999) · Technology and Health Care · doi:10.3233/thc-1999-7612 · Cited by 103 · cited 1×
“Luinge et al. (1999) suggested a method to solve the problem of output drift when using gyroscope.”
MethodA real-time gyroscopic system for three-dimensional measurement of lumbar spine motion
Lee, R. Y. W., Laprade, J., & Fung, E. H. K. (2003) · Medical Engineering & Physics · doi:10.1016/s1350-4533(03)00115-2 · Cited by 99 · cited 2×
“Lee et al. (2003) described a method of using an inertial tracking device to measure three-dimensional movement patterns of the lumbar spine in real time, which consisted of gyroscopes, and also with gravitometers and magnetometers.”
BackgroundMethodLower extremity angle measurement with accelerometers-error and sensitivity analysis
Willemsen, A. T. M., Frigo, C., & Boom, H. B. K. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.137284 · Cited by 92 · cited 1×
“Several locomotion studies have tried to use accelerometers to determine the stages of lower limb movement in gait analysis (Veltink and Franken 1996; Veltink et al. 1998; Willemsen et al. 1991).”
BackgroundMeasuring spinal motion in rowers: the use of an electromagnetic device
Bull, A. M. J., & McGregor, A. H. (2000) · Clinical Biomechanics · doi:10.1016/s0268-0033(00)00043-7 · Cited by 89 · cited 2×
“…with similar design are commercially available for kinematics studies in movements in different body segments, including upper limbs (Finley and Lee 2003; Ramanathan et al. 2000) and spine (Bull and McGregor 2000; Lee 2001; Mannion and Troke 1999; Pearcy and Hindle 1989; Willems et al. 1996).”
MethodEngsberg, J. R., Lenke, L. G., Uhrich, M. L., Ross, S. A., & Bridwell, K. H. (2003) · Spine · doi:10.1097/01.brs.0000087209.34602.42 · Cited by 81 · cited 2×
“1995), and video analysis (Robinson et al. 1993; Masso and Gorton 2000; Nault et al. 2002; Engsberg et al. 2003).”
BackgroundA comparison of two motion analysis devices used in the measurement of lumbar spinal mobility
Mannion, A. F., & Troke, M. (1999) · Clinical Biomechanics · doi:10.1016/s0268-0033(99)00017-0 · Cited by 79 · cited 2×
“…with similar design are commercially available for kinematics studies in movements in different body segments, including upper limbs (Finley and Lee 2003; Ramanathan et al. 2000) and spine (Bull and McGregor 2000; Lee 2001; Mannion and Troke 1999; Pearcy and Hindle 1989; Willems et al. 1996).”
MethodVan Someren, E. J. W. (1997) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.650297 · Cited by 78 · cited 1×
“Van Someren (1996) suggested using an accelerometer to measure the duration and intensity of wrist movement in patients with Parkinson’s disease.”
BackgroundContinuous measurement of lumbar posture using flexible electrogoniometers
Boocock, M., Jackson, J. A., Burton, K. A., & Tillotson, K. M. (1994) · Ergonomics · doi:10.1080/00140139408963636 · Cited by 69 · cited 4×
“…comparable with the value of radiographic data in lumbar curvature and range of motion, the device could provide quantitative information of lumbar sagittal motion in continuous measurement and was recommended for use in a variety of occupational and recreational environments (Boocock et al. 1994).”
BackgroundInfluentialMasso, P. D., & Gorton, G. E. (2000) · Spine · doi:10.1097/00007632-200002150-00011 · Cited by 64 · cited 1×
“…photogrammetry (Weissman 1968; Bullock and Harley 1972; Thometz et al. 2000; Liu et al. 2001), optoelectric analysis (Pearcy et al. 1987; Dawson et al. 1993; Gracovetsky et al. 1995), and video analysis (Robinson et al. 1993; Masso and Gorton 2000; Nault et al. 2002; Engsberg et al. 2003).”
BackgroundRelationship Between Quantec Measurement and Cobb Angle in Patients with Idiopathic Scoliosis
Thometz, J., Lamdan, R., Liu, X. C., & Lyon, R. (2000) · Journal of Pediatric Orthopaedics · doi:10.1097/01241398-200007000-00017 · Cited by 63 · cited 2×
“…postures and movements have been measured by using different image-based methods including photogrammetry (Weissman 1968; Bullock and Harley 1972; Thometz et al. 2000; Liu et al. 2001), optoelectric analysis (Pearcy et al. 1987; Dawson et al. 1993; Gracovetsky et al. 1995), and video analysis…”
MethodEffects of a lumbar support on spine posture and motion assessed by electrogoniometer and recording
Thoumie, P., Drapé, J., Aymard, C., & Bedoiseau, M. (1998) · Clinical Biomechanics · doi:10.1016/s0268-0033(97)00084-3 · Cited by 57 · cited 2×
“The use of commercial flexible electro-goniometer to provide continuous quantitative information on lumbar spinal motion has been reported by Boocock et al. (1994) and Thoumie et al. (1998).”
BackgroundResultKinematics of rotational mobilisation of the lumbar spine
Lee, R. Y. W. (2001) · Clinical Biomechanics · doi:10.1016/s0268-0033(01)00036-5 · Cited by 52 · cited 2×
“…with similar design are commercially available for kinematics studies in movements in different body segments, including upper limbs (Finley and Lee 2003; Ramanathan et al. 2000) and spine (Bull and McGregor 2000; Lee 2001; Mannion and Troke 1999; Pearcy and Hindle 1989; Willems et al. 1996).”
MethodFunctional Classification of Patients With Idiopathic Scoliosis Assessed by the Quantec System
Liu, X.-C., Thometz, J., Lyon, R. M., & Klein, J. P. (2001) · Spine · doi:10.1097/00007632-200106010-00020 · Cited by 52 · cited 1×
“…have been measured by using different image-based methods including photogrammetry (Weissman 1968; Bullock and Harley 1972; Thometz et al. 2000; Liu et al. 2001), optoelectric analysis (Pearcy et al. 1987; Dawson et al. 1993; Gracovetsky et al. 1995), and video analysis (Robinson et al. 1993;…”
MethodThe study of kinematic transients in locomotion using the integrated kinematic sensor
Wu, G., & Ladin, Z. (1996) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.536775 · Cited by 46
Optoelectronic Evaluation of Trunk Deformity in Scoliosis
Dawson, E. G., Kropf, M. A., Purcell, G. A., Kabo, J. M., Kanim, L. E. A., & Burt, C. (1993) · Spine · doi:10.1097/00007632-199303000-00003 · Cited by 41 · cited 1×
“…including photogrammetry (Weissman 1968; Bullock and Harley 1972; Thometz et al. 2000; Liu et al. 2001), optoelectric analysis (Pearcy et al. 1987; Dawson et al. 1993; Gracovetsky et al. 1995), and video analysis (Robinson et al. 1993; Masso and Gorton 2000; Nault et al. 2002; Engsberg et al.…”
A three-dimensional ultrasonic system for posture measurement
Hsiao, H., & Keyserling, W. M. (1990) · Ergonomics · doi:10.1080/00140139008925316 · Cited by 36 · cited 1×
“Lee et al. (2003) described a method of using an inertial tracking device to measure three-dimensional movement patterns of the lumbar spine in real time, which consisted of gyroscopes, and also with gravitometers and magnetometers.”
MethodA posture monitoring system using accelerometers
Nevins, R. J., Durdle, N. G., & Raso, V. J. (2003) · Conference proceedings - Canadian Conference on Electrical and Computer Engineering · doi:10.1109/ccece.2002.1013098 · Cited by 35 · cited 1×
“Nevins et al. (2002) made use of six accelerometers for continuous monitoring of spinal posture on the sagittal plane.”
MethodMeasurement of human back movements in three dimensions by opto-electronic devices
Pearcy, M. J., Gill, J. M., Hindle, R. J., & Johnson, G. (1987) · Clinical Biomechanics · doi:10.1016/0268-0033(87)90082-9 · Cited by 32 · cited 2×
“…image-based methods including photogrammetry (Weissman 1968; Bullock and Harley 1972; Thometz et al. 2000; Liu et al. 2001), optoelectric analysis (Pearcy et al. 1987; Dawson et al. 1993; Gracovetsky et al. 1995), and video analysis (Robinson et al. 1993; Masso and Gorton 2000; Nault et al. 2002;…”
MethodMonitoring body kinematics and gesture through sensing fabrics
Rossi, D. D., Lorussi, F., Mazzoldi, A., Orsini, P., & Scilingo, E. P. (2002) · International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine and Biology (MMB) · doi:10.1109/mmb.2000.893853 · Cited by 31 · cited 3×
“De Rossi et al. (2000) developed a minimally intrusive wearable system consisting of a Lycra leotard with conductive polymer strain sensors chemically deposited in selected areas.”
BackgroundMethodAnalysis of arm trajectories of everyday tasks for the development of an upper-limb orthosis
Nathan, R., Eberhardt, S. P., Rahman, T., Sample, W., Seliktar, R., & Alexander, M. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.830950 · Cited by 29 · cited 4×
“Systems with similar design are commercially available for kinematics studies in movements in different body segments, including upper limbs (Finley and Lee 2003; Ramanathan et al. 2000) and spine (Bull and McGregor 2000; Lee 2001; Mannion and Troke 1999; Pearcy and Hindle 1989; Willems et al.”
MethodInfluentialA framework for progressive medical image transmission and compression
Dilmaghani, R., Ahmadian, A., & Oghabian, M. A. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2002.1106258 · Cited by 28
Intrasubject Reliability of Spinal Range of Motion and Velocity Determined by Video Motion Analysis
Robinson, M. E., O'Connor, P. D. T., Shirley, F. R., & Millan, M. M. (1993) · Physical Therapy · doi:10.1093/ptj/73.9.626 · Cited by 28 · cited 2×
“1995), and video analysis (Robinson et al. 1993; Masso and Gorton 2000; Nault et al. 2002; Engsberg et al. 2003).”
BackgroundThe feasibility of posture and movement detection by accelerometry
Veltink, P. H., Bussmann, H., Koelma, F., Franken, H. M., Martens, W. L. J., & van Lummel, R. C. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1993.979109 · Cited by 24 · cited 1×
“The static and dynamic activities could be discriminated, and the postures and the orientations of body segments could also be detected (Bouten et al. 1997; Fahrenberg et al. 1997; Foerster et al. 1999; Lyons et al. 2005; Mathie et al. 2001; Veltink et al. 1993; 1996).”
BackgroundTrunk motion analysis in walking using gyro sensors
Ochi, F., Abe, K., Ishigami, S., Otsu, K., & Tomita, H. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1997.757084 · Cited by 23 · cited 1×
“Ochi et al. (1997) evaluated the trunk motions of stroke patients, cerebral palsy patients and normal subjects in walking.”
BackgroundDetection of knee unlock during stance by accelerometry
Veltink, P. H., & Franken, H. M. (1996) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.547941 · Cited by 23
The Measurement of Three-Dimensional Body Movements by the Use of Photogrammetry
Bullock, B., & HARLEY, T. A. (1972) · Ergonomics · doi:10.1080/00140137208924433 · Cited by 22 · cited 1×
“Human postures and movements have been measured by using different image-based methods including photogrammetry (Weissman 1968; Bullock and Harley 1972; Thometz et al. 2000; Liu et al. 2001), optoelectric analysis (Pearcy et al. 1987; Dawson et al. 1993; Gracovetsky et al. 1995), and video analysis…”
MethodA low power accelerometer used to improve posture
Lou, E., Bazzarelli, M., Hill, D. L., & Durdle, N. G. (2002) · Conference proceedings - Canadian Conference on Electrical and Computer Engineering · doi:10.1109/ccece.2001.933657 · Cited by 19 · cited 1×
“Non-commercial accelerometer system with one accelerometer was developed by Lou et al. (2001) for posture monitoring and training.”
MethodFlexible angular sensor [and biomechanical application]
Roduit, R., Besse, P.-A., & Micallef, J. P. (1998) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/19.744661 · Cited by 19 · cited 2×
“Apart from inertial sensors, mechanical flexible angular sensing device was applied to measure knee angles during walking (Roduit et al. 1998).”
MethodVeltink, P. H., Engberink, E. G. O., van Hilten, B. J., Dunnewold, R. J. W., & Jacobi, C. E. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1995.579693 · Cited by 19
A wearable computer for physiotherapeutic scoliosis treatment
Bazzarelli, M., Durdle, N. G., Lou, E., & Raso, V. J. (2003) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2003.809485 · Cited by 18
A low-power posture measurement system for the treatment of scoliosis
Lou, E., Durdle, N. G., Raso, V. J., & Hill, D. L. (2000) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/19.836319 · Cited by 14 · cited 3×
“The results demonstrated that the accuracy of the system could be 5 mm for the distance measurement in the distance 300 – 480 mm and 58 for angle measurements from 0 – 908 (Lou et al. 1999, 2000).”
BackgroundTrunk Rotation Monitor Using Angular Velocity Sensors.
Akihiko, S. E. O., & Shinichi, U. D. A. (1997) · Industrial Health · doi:10.2486/indhealth.35.222 · Cited by 12 · cited 2×
“For instance, in the gyroscope’s system, angular displacement can be calculated theoretically by numerical integration of angular velocity but it is not easy to apply directly because of output drift and accumulated error of the sensor (Lee et al. 2003; Seo and Uda 1997).”
BackgroundMethodBio-feedback-system analysis in walking using three gyro sensors
Tsuruoka, Y., Ochi, F., & Tsuraoka, M. (2003) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1999.802606 · Cited by 12 · cited 1×
“Tsuruoka et al. (1999) suggested a method to evaluate human movement stability by analyzing the relative power contribution in head, trunk and pelvic movement derived from the measured signals of gyroscopes during walking.”
MethodRoduit, R., & Micallef, J. (1998) · Cited by 12
A low power hybrid posture monitoring system
Bazzarelli, M., Durdle, N. G., Lou, E., & Raso, J. V. (2002) · Conference proceedings - Canadian Conference on Electrical and Computer Engineering · doi:10.1109/ccece.2001.933652 · Cited by 11
Active dressware: wearable proprioceptive systems based on electroactive polymers
Rossi, D. D., Lorussi, F., Mazzoldi, A., Scilingo, E. P., & Orsini, P. (2002) · International Symposium on Wearable Computers · doi:10.1109/iswc.2001.962123 · Cited by 11 · cited 1×
“A sensorized glove was developed by De Rossi et al. (2001), who used elastic textile fibres and strain sensors to monitor movement of hand segments.”
MethodArtificial and natural sensors in FES-assisted human movement control
Veltink, P. H., Sinkjær, T., Baten, C. T. M., Bergveld, P., van der Spek, J., & Haugland, M. K. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1998.744684 · Cited by 8 · cited 1×
“Several locomotion studies have tried to use accelerometers to determine the stages of lower limb movement in gait analysis (Veltink and Franken 1996; Veltink et al. 1998; Willemsen et al. 1991).”
BackgroundA low power portable electromagnetic posture monitoring system [for scoliosis treatment]
Bazzarelli, M., Durdle, N. G., Lou, E., & Raso, J. V. (2002) · Conference proceedings - IEEE Instrumentation/Measurement Technology Conference · doi:10.1109/imtc.2001.928892 · Cited by 7
Method for monitoring acceleration of the trunk during gait
Villanueva, D., Trujillo, A. P., Fermon, E., Cardiel, E., & Hedz, P.-R. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2002.1106638 · Cited by 6 · cited 1×
“Villanueva et al. (2002) studied an electronic instrument with accelerometers for monitoring the trunk trajectory of human body walking on a treadmill.”
BackgroundContinuous assessment of posture in adolescent idiopathic scoliosis
Lou, E., Hill, D. L., Raso, V. J., & Durdle, N. G. (2003) · Conference proceedings - Canadian Conference on Electrical and Computer Engineering · doi:10.1109/ccece.1999.804935 · Cited by 4 · cited 2×
“The results demonstrated that the accuracy of the system could be 5 mm for the distance measurement in the distance 300 – 480 mm and 58 for angle measurements from 0 – 908 (Lou et al. 1999, 2000).”
Background
Research works printed but not linked: 1
- Weissman, 1968, Anthropometric photogrammetry, Photogrammetr Engin, 34, 1134
Cited by
Comparative study on classifying human activities with miniature inertial and magnetic sensors
Altun, K., Barshan, B., & Tunçel, O. (2010) · Pattern Recognition · doi:10.1016/j.patcog.2010.04.019 · Cited by 564
“A 016/j.patcog.2010.04.019 esponding author. ail address: billur@ee.bilkent.edu.tr (B. Barsha a b s t r a c t This paper provides a comparative study on the different techniques of classifying human activities that are performed using body-worn miniature inertial and magnetic sensors.”
BackgroundInfluentialSensors for daily life: A review
Javaid, M., Haleem, A., Rab, S., Pratap Singh, R., & Suman, R. (2021) · Sensors International · doi:10.1016/j.sintl.2021.100121 · Cited by 430
The use of inertial sensors system for human motion analysis
Cuesta-Vargas, A. I., Galán-Mercant, A., & Williams, J. M. (2010) · Physical Therapy Reviews · doi:10.1179/1743288x11y.0000000006 · Cited by 369
Interactive wearable systems for upper body rehabilitation: a systematic review
Wang, Q., Markopoulos, P., Yu, B., Chen, W., & Timmermans, A. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0229-y · Cited by 348
“Discussion of wearable-sensing technologies Advanced technologies have been developed and applied to solve the relevant application problems [27].”
Methods for gait event detection and analysis in ambulatory systems
Rueterbories, J., Spaich, E. G., Larsen, B., & Andersen, O. K. (2010) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2010.03.007 · Cited by 350
Metadata
- Authors
- Wong, W. Y., Wong, M. S., & Lo, K. H.
- Affiliations
- Hong Kong Polytechnic University (HK)
- ORCID
- Wong, Man Sang
- Venue
- Prosthetics & Orthotics International
- Published
- 2007-03
- Volume
- 31
- Issue
- 1
- Pages
- 62-75
- ISSN
- 0309-3646 (ISSN-L)
- OpenAlex
- W2115115183
- Cited by
- 193
- References
- 59
- Citations by year
- 2026: 3 · 2025: 10 · 2024: 10 · 2023: 10 · 2022: 8 · 2021: 15 · 2020: 12 · 2019: 8 · 2018: 17 · 2017: 10 · 2016: 11 · 2015: 13 · 2014: 10 · 2013: 12 · 2012: 6
- FWCI
- 2.49
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Prosthetics and Orthotics International (publishedVersion)
- PubMed (publishedVersion)
- PolyU Institutional Research Archive (Hong Kong Polytechnic University) (submittedVersion)
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Balance, Gait, and Falls Prevention
- Social Sciences › Human Factors and Ergonomics › Ergonomics and Musculoskeletal Disorders
- Keywords
- human motion analysis, electronic sensors, accelerometer, gyroscope, electromagnetic tracking, rehabilitation assessment, clinical application, signal extraction, environmental interference
- MeSH terms
- Biomechanical Phenomena, Biomedical Engineering, Electronics, Medical, Environment, Gait, Humans, Movement, Posture, Rehabilitation, Upper Extremity, Electromagnetic Phenomena
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.