Microneedles for transdermal drug delivery: a systematic review
The DOI matches its Crossref record; 90 of the 90 references it cites were found in a registry or an index.
Abstract
Transdermal route has been explored for various agents due to its advantage of bypassing the first pass effect and sustained release of drug. Due to strong barrier properties of the skin, mainly stratum corneum (SC), the delivery of many therapeutic agents across the skin has become challenging. Few drugs with specific physicochemical properties (molecular weight <500 Da, adequate lipophilicity, and low melting point) can be effectively administered via transdermal route. However, delivery of hydrophilic drugs and macromolecular agents including peptides, DNA and small interfering RNA is challenging. Drug penetration through the SC may involve bypass or reversible disruption of SC layer by various means. Recently, the use of micron-scale needles has been proposed in increasing skin permeability and shown to dramatically increase permeation, especially for macromolecules. Microneedles (MNs) can penetrate through the SC layer of the skin into the viable epidermis, avoiding contact with nerve fibers and blood vessels that reside primarily in the dermal layer. This review summarizes the types of MNs and fabrication techniques of different types of MNs. The safety aspects of the materials used for fabrication have been discussed in detail. Biological applications and relevant phase III clinical trials are also highlighted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review on stereolithography and its applications in biomedical engineering
Melchels, F. P. W., Feijen, J., & Grijpma, D. W. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.04.050 · Cited by 2,457 · cited 1×
“In this structure, the conversion of reactive groups is usually incomplete, and post-curing with (stroboscopic) ultraviolet light is often done to improve the mechanical properties of the structures” [73].”
BackgroundMicrofabricated Microneedles: A Novel Approach to Transdermal Drug Delivery
Henry, S., McAllister, D. V., Allen, M. G., & Prausnitz, M. R. (1998) · Journal of Pharmaceutical Sciences · doi:10.1021/js980042+ · Cited by 1,346 · cited 1×
“It is similar to deep plasma etching [69].”
BackgroundBiodegradable polymer microneedles: Fabrication, mechanics and transdermal drug delivery
Park, J.-H., Allen, M. G., & Prausnitz, M. R. (2005) · Journal of Controlled Release · doi:10.1016/j.jconrel.2005.02.002 · Cited by 1,026
Dissolving polymer microneedle patches for influenza vaccination
Sullivan, S. P., Koutsonanos, D. G., del Pilar Martin, M., Lee, J. W., Zarnitsyn, V., Choi, S.-O., Murthy, N., Compans, R. W., Skountzou, I., & Prausnitz, M. R. (2010) · Nature Medicine · doi:10.1038/nm.2182 · Cited by 948 · cited 1×
“Such MNs are not only painless but also deliver the vaccine successfully in the skin without eliciting any immune response [84].”
BackgroundCampbell, P. K., Jones, K. E., Huber, R. J., Horch, K. W., & Normann, R. A. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83588 · Cited by 881 · cited 1×
“This is due to the reduced rate at bottom, attributed to the lack of fluid motion to replenish it [6,70].”
BackgroundCoated microneedles for transdermal delivery
Gill, H. S., & Prausnitz, M. R. (2007) · Journal of Controlled Release · doi:10.1016/j.jconrel.2006.10.017 · Cited by 765 · cited 2×
“Final structure is established by electropolishing which sharpens the tips [7,8].”
BackgroundMethodEffect of Microneedle Design on Pain in Human Volunteers
Gill, H. S., Denson, D. D., Burris, B. A., & Prausnitz, M. R. (2008) · The Clinical Journal of Pain · doi:10.1097/ajp.0b013e31816778f9 · Cited by 701 · cited 4×
“No statistically significant relationship could be established between pain and other parameters such as tip angle, needle thickness, and width [37].”
InfluentialLack of Pain Associated with Microfabricated Microneedles
Kaushik, S., Hord, A. H., Denson, D. D., McAllister, D. V., Smitra, S., Allen, M. G., & Prausnitz, M. R. (2001) · Anesthesia & Analgesia · doi:10.1097/00000539-200102000-00041 · Cited by 576
Transdermal Delivery of Insulin Using Microneedles in Vivo
Martanto, W., Davis, S. P., Holiday, N. R., Wang, J., Gill, H. S., & Prausnitz, M. R. (2004) · Pharmaceutical Research · doi:10.1023/b:pham.0000029282.44140.2e · Cited by 521 · cited 1×
“Final structure is established by electropolishing which sharpens the tips [7,8].”
BackgroundMikszta, J. A., Alarcon, J. B., Brittingham, J. M., Sutter, D. E., Pettis, R. J., & Harvey, N. G. (2002) · Nature Medicine · doi:10.1038/nm0402-415 · Cited by 398 · cited 2×
“[32] wherein the silicon MN insertion did not harbor infection or other adverse events.”
Background
Cited by
Makvandi, P., Kirkby, M., Hutton, A. R. J., Shabani, M., Yiu, C. K. Y., Baghbantaraghdari, Z., Jamaledin, R., Carlotti, M., Mazzolai, B., Mattoli, V., et al. (2021) · Nano-Micro Letters · doi:10.1007/s40820-021-00611-9 · Cited by 455
Microneedle for transdermal drug delivery: current trends and fabrication
Jung, J. H., & Jin, S. G. (2021) · Journal of Pharmaceutical Investigation · doi:10.1007/s40005-021-00512-4 · Cited by 416
Lyu, S., Dong, Z., Xu, X., Bei, H.-P., Yuen, H.-Y., James Cheung, C.-W., Wong, M.-S., He, Y., & Zhao, X. (2023) · Bioactive Materials · doi:10.1016/j.bioactmat.2023.04.003 · Cited by 266
Microneedle-Based Delivery: An Overview of Current Applications and Trends
Guillot, A. J., Cordeiro, A. S., Donnelly, R. F., Montesinos, M. C., Garrigues, T. M., & Melero, A. (2020) · Pharmaceutics · doi:10.3390/pharmaceutics12060569 · Cited by 254
Microneedle-Mediated Transdermal Delivery of Biopharmaceuticals
Nguyen, H. X., & Nguyen, C. N. (2023) · Pharmaceutics · doi:10.3390/pharmaceutics15010277 · Cited by 175
“The clinical safety of various microneedle types and safety aspects of microneedle materials have been reviewed elsewhere [31,59].”
Background
Metadata
- Authors
- Dharadhar, S., Majumdar, A., Dhoble, S., & Patravale, V.
- Venue
- Drug Development and Industrial Pharmacy
- Publisher
- Informa UK Limited
- Published
- 2018-11-27
- Volume
- 45
- Issue
- 2
- Pages
- 188-201
- ISSN
- 0363-9045 (ISSN-L)
- 1520-5762
- OpenAlex
- W2898611803
- Cited by
- 188
- References
- 90
- FWCI
- 1.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.