Microneedles for transdermal drug delivery: a systematic review
The DOI matches its Crossref record; 90 of the 90 references it cites were found in a registry or an index.
Abstract
Transdermal route has been explored for various agents due to its advantage of bypassing the first pass effect and sustained release of drug. Due to strong barrier properties of the skin, mainly stratum corneum (SC), the delivery of many therapeutic agents across the skin has become challenging. Few drugs with specific physicochemical properties (molecular weight <500 Da, adequate lipophilicity, and low melting point) can be effectively administered via transdermal route. However, delivery of hydrophilic drugs and macromolecular agents including peptides, DNA and small interfering RNA is challenging. Drug penetration through the SC may involve bypass or reversible disruption of SC layer by various means. Recently, the use of micron-scale needles has been proposed in increasing skin permeability and shown to dramatically increase permeation, especially for macromolecules. Microneedles (MNs) can penetrate through the SC layer of the skin into the viable epidermis, avoiding contact with nerve fibers and blood vessels that reside primarily in the dermal layer. This review summarizes the types of MNs and fabrication techniques of different types of MNs. The safety aspects of the materials used for fabrication have been discussed in detail. Biological applications and relevant phase III clinical trials are also highlighted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review on stereolithography and its applications in biomedical engineering
Melchels, F. P. W., Feijen, J., & Grijpma, D. W. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.04.050 · Cited by 2,457 · cited 1×
“In this structure, the conversion of reactive groups is usually incomplete, and post-curing with (stroboscopic) ultraviolet light is often done to improve the mechanical properties of the structures” [73].”
BackgroundMicrofabricated Microneedles: A Novel Approach to Transdermal Drug Delivery
Henry, S., McAllister, D. V., Allen, M. G., & Prausnitz, M. R. (1998) · Journal of Pharmaceutical Sciences · doi:10.1021/js980042+ · Cited by 1,346 · cited 1×
“It is similar to deep plasma etching [69].”
BackgroundBiodegradable polymer microneedles: Fabrication, mechanics and transdermal drug delivery
Park, J.-H., Allen, M. G., & Prausnitz, M. R. (2005) · Journal of Controlled Release · doi:10.1016/j.jconrel.2005.02.002 · Cited by 1,026
Dissolving polymer microneedle patches for influenza vaccination
Sullivan, S. P., Koutsonanos, D. G., del Pilar Martin, M., Lee, J. W., Zarnitsyn, V., Choi, S.-O., Murthy, N., Compans, R. W., Skountzou, I., & Prausnitz, M. R. (2010) · Nature Medicine · doi:10.1038/nm.2182 · Cited by 948 · cited 1×
“Such MNs are not only painless but also deliver the vaccine successfully in the skin without eliciting any immune response [84].”
BackgroundCampbell, P. K., Jones, K. E., Huber, R. J., Horch, K. W., & Normann, R. A. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83588 · Cited by 881 · cited 1×
“This is due to the reduced rate at bottom, attributed to the lack of fluid motion to replenish it [6,70].”
BackgroundCoated microneedles for transdermal delivery
Gill, H. S., & Prausnitz, M. R. (2007) · Journal of Controlled Release · doi:10.1016/j.jconrel.2006.10.017 · Cited by 765 · cited 2×
“Final structure is established by electropolishing which sharpens the tips [7,8].”
BackgroundMethodEffect of Microneedle Design on Pain in Human Volunteers
Gill, H. S., Denson, D. D., Burris, B. A., & Prausnitz, M. R. (2008) · The Clinical Journal of Pain · doi:10.1097/ajp.0b013e31816778f9 · Cited by 701 · cited 4×
“No statistically significant relationship could be established between pain and other parameters such as tip angle, needle thickness, and width [37].”
InfluentialLack of Pain Associated with Microfabricated Microneedles
Kaushik, S., Hord, A. H., Denson, D. D., McAllister, D. V., Smitra, S., Allen, M. G., & Prausnitz, M. R. (2001) · Anesthesia & Analgesia · doi:10.1097/00000539-200102000-00041 · Cited by 576
Transdermal Delivery of Insulin Using Microneedles in Vivo
Martanto, W., Davis, S. P., Holiday, N. R., Wang, J., Gill, H. S., & Prausnitz, M. R. (2004) · Pharmaceutical Research · doi:10.1023/b:pham.0000029282.44140.2e · Cited by 521 · cited 1×
“Final structure is established by electropolishing which sharpens the tips [7,8].”
BackgroundMikszta, J. A., Alarcon, J. B., Brittingham, J. M., Sutter, D. E., Pettis, R. J., & Harvey, N. G. (2002) · Nature Medicine · doi:10.1038/nm0402-415 · Cited by 398 · cited 2×
“[32] wherein the silicon MN insertion did not harbor infection or other adverse events.”
BackgroundTransdermal delivery of desmopressin using a coated microneedle array patch system
Cormier, M., Johnson, B. L., Ameri, M., Nyam, K., LIBIRAN, L., Zhang, D. D., & Daddona, P. E. (2004) · Journal of Controlled Release · doi:10.1016/j.jconrel.2004.04.003 · Cited by 388 · cited 4×
“The erythema resolves with time with no development of edema, bleeding or infection [24].”
BackgroundInfluentialKinetics of skin resealing after insertion of microneedles in human subjects
Gupta, J., Gill, H. S., Andrews, S. N., & Prausnitz, M. R. (2011) · Journal of Controlled Release · doi:10.1016/j.jconrel.2011.05.021 · Cited by 342 · cited 5×
“Most common metals used for the production of MNs include stainless steel [2,19,25,36,37], titanium [24,38], palladium [39], nickel [39,40], platinum [41], alloys [39,42], and gold [39].”
BackgroundInfluentialPrecise Microinjection into Skin Using Hollow Microneedles
Wang, P. M., Cornwell, M., Hill, J., & Prausnitz, M. R. (2006) · Journal of Investigative Dermatology · doi:10.1038/sj.jid.5700150 · Cited by 332 · cited 3×
“Examination of a skin resealing after infusion or suprachoroidal injection examined visually or under microscopes exhibited complete resealing of the pores within 2 hours of administration in each case [19,22,47].”
BackgroundVan Damme, P., Oosterhuis-Kafeja, F., Van der Wielen, M., Almagor, Y., Sharon, O., & Levin, Y. (2009) · Vaccine · doi:10.1016/j.vaccine.2008.10.077 · Cited by 331 · cited 4×
“However, the administration pain by both the routes does not differ significantly [15].”
BackgroundInfluentialClinical administration of microneedles: skin puncture, pain and sensation
Haq, M. I., Smith, E., John, D. N., Kalavala, M., Edwards, C., Anstey, A., Morrissey, A., & Birchall, J. C. (2009) · Biomedical Microdevices · doi:10.1007/s10544-008-9208-1 · Cited by 329 · cited 3×
“Methylene blue staining traced the microchannel repair and resealing following application of wet-etch silicon MNs, which was apparent at 8–24 hours post application of silicon MNs [3].”
BackgroundDroplet-born air blowing: Novel dissolving microneedle fabrication
Kim, J. D., Kim, M., Yang, H., Lee, K., & Jung, H. (2013) · Journal of Controlled Release · doi:10.1016/j.jconrel.2013.05.026 · Cited by 326 · cited 1×
“Finally, an isolation step is performed to separate two MN arrays from each surface [12].”
MethodMicroneedles permit transdermal delivery of a skin-impermeant medication to humans
Wermeling, D. P., Banks, S. L., Hudson, D. A., Gill, H. S., Gupta, J., Prausnitz, M. R., & Stinchcomb, A. L. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0710355105 · Cited by 311 · cited 6×
“Other experiments demonstrated parallel results whereby MNs varying in geometries and up to a length of 400mm did not elicit any pain when applied alone [36], or when followed by application of other formulations [20].”
BackgroundMethodResultInfluentialBiocompatibility and resorption of a brushite calcium phosphate cement
Theiss, F., Apelt, D., Brand, B., Kutter, A., Zlinszky, K., Bohner, M., Matter, S., Frei, C., Auer, J. A., & von Rechenberg, B. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.11.056 · Cited by 304
In vivo assessment of safety of microneedle arrays in human skin
Bal, S. M., Caussin, J., Pavel, S., & Bouwstra, J. A. (2008) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2008.06.016 · Cited by 303 · cited 4×
“Other experiments demonstrated parallel results whereby MNs varying in geometries and up to a length of 400mm did not elicit any pain when applied alone [36], or when followed by application of other formulations [20].”
BackgroundResultInfluentialDissolving Microneedle Patch for Transdermal Delivery of Human Growth Hormone
Lee, J. W., Choi, S., Felner, E. I., & Prausnitz, M. R. (2011) · Small · doi:10.1002/smll.201001091 · Cited by 301 · cited 2×
“Molds can also be prepared by UV lithography [72].”
BackgroundCoated Microneedles for Drug Delivery to the Eye
Jiang, J., Gill, H. S., Ghate, D., McCarey, B. E., Patel, S. R., Edelhauser, H. F., & Prausnitz, M. R. (2007) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.07-0066 · Cited by 286 · cited 3×
“Metals are utilized for production of solid [2,20,36,37], hollow [19,39,40], and as base of the coated MNs [5,24,25].”
BackgroundMicroinfusion Using Hollow Microneedles
Martanto, W., Moore, J. S., Kashlan, O., Kamath, R., Wang, P. M., O'Neal, J. M., & Prausnitz, M. R. (2006) · Pharmaceutical Research · doi:10.1007/s11095-005-8498-8 · Cited by 262 · cited 1×
“Glass MNs of various geometries have been manufactured which successfully pierce through SC [46,47].”
BackgroundTwo Photon Polymerization of Polymer–Ceramic Hybrid Materials for Transdermal Drug Delivery
Ovsianikov, A., Chichkov, B., Mente, P., Monteiro‐Riviere, N. A., Doraiswamy, A., & Narayan, R. J. (2007) · International Journal of Applied Ceramic Technology · doi:10.1111/j.1744-7402.2007.02115.x · Cited by 259 · cited 1×
“and exhibits good biocompatibility [55].”
Metal microneedle fabrication using twisted light with spin
Omatsu, T., Chujo, K., Miyamoto, K., Okida, M., Nakamura, K., Aoki, N., & Morita, R. (2010) · Optics Express · doi:10.1364/oe.18.017967 · Cited by 259
Process optimization and characterization of silicon microneedles fabricated by wet etch technology
Wilke, N., Mulcahy, A., Ye, S.-R., & Morrissey, A. (2005) · Microelectronics Journal · doi:10.1016/j.mejo.2005.04.044 · Cited by 243 · cited 2×
“Silicon forms MNs with substantial mechanical strength which empowers the MNs to successfully pierce the skin [31].”
BackgroundMethodPatel, S. R., Berezovsky, D. E., McCarey, B. E., Zarnitsyn, V., Edelhauser, H. F., & Prausnitz, M. R. (2012) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.12-9872 · Cited by 241 · cited 7×
“Most common metals used for the production of MNs include stainless steel [2,19,25,36,37], titanium [24,38], palladium [39], nickel [39,40], platinum [41], alloys [39,42], and gold [39].”
BackgroundInfluentialMicroneedle Arrays Allow Lower Microbial Penetration Than Hypodermic Needles In Vitro
Donnelly, R. F., Singh, T. R. R., Tunney, M. M., Morrow, D. I. J., McCarron, P. A., O’Mahony, C., & Woolfson, A. D. (2009) · Pharmaceutical Research · doi:10.1007/s11095-009-9967-2 · Cited by 227 · cited 2×
“The observations were that total viable count of microorganisms crossing punctured membranes was of lower magnitude than hypodermic needles suggesting a lower risk of infection [64].”
BackgroundSuper-short solid silicon microneedles for transdermal drug delivery applications
Wei-Ze, L., Mei-Rong, H., Jian-Ping, Z., Yong-Qiang, Z., Bao-Hua, H., Ting, L., & Yong, Z. (2010) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2010.01.024 · Cited by 217
Minimally Invasive Insulin Delivery in Subjects with Type 1 Diabetes Using Hollow Microneedles
Gupta, J., Felner, E. I., & Prausnitz, M. R. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2008.0103 · Cited by 209 · cited 5×
“The hollow type [13,16,22] is commonly fabricated.”
BackgroundMethodInfluentialDrawing Lithography: Three‐Dimensional Fabrication of an Ultrahigh‐Aspect‐Ratio Microneedle
Lee, K., Lee, H. C., Lee, D., & Jung, H. (2010) · Advanced Materials · doi:10.1002/adma.200902418 · Cited by 208 · cited 3×
“Nickel electroplating followed by solubilisation of the polymer can be used to fabricate hollow MNs [71].”
BackgroundMethodInfluentialTran, B. Q., Miller, P. R., Taylor, R. M., Boyd, G., Mach, P. M., Rosenzweig, C. N., Baca, J. T., Polsky, R., & Glaros, T. (2018) · Journal of Proteome Research · doi:10.1021/acs.jproteome.7b00642 · Cited by 198 · cited 1×
“This study implies that interstitial fluid collection, with the help of hollow MNs, can be an alternative to plasma or serum sampling, due to minimum invasiveness of the former [77].”
BackgroundBiocompatibility of Surgical-Grade Dense Polycrystalline Alumina
Christel, P. (1992) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199209000-00003 · Cited by 198
Gittard, S. D., Nguyen, A., Obata, K., Koroleva, A., Narayan, R. J., & Chichkov, B. N. (2011) · Biomedical Optics Express · doi:10.1364/boe.2.003167 · Cited by 189 · cited 1×
“After completion of fabrication of the MN, the nonirradiated resin is washed away using appropriate solvent and is cured using ultraviolet light [9,10,52].”
MethodInfusion pressure and pain during microneedle injection into skin of human subjects
Gupta, J., Park, S. S., Bondy, B. J., Felner, E. I., & Prausnitz, M. R. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.05.061 · Cited by 180 · cited 9×
“8ml can induce pain even at a depth of 750 mm at a moderate and constant flow rate [22].”
BackgroundMethodInfluentialClinical microneedle injection of methyl nicotinate: stratum corneum penetration
Sivamani, R. K., Stoeber, B., Wu, G. C., Zhai, H., Liepmann, D., & Maibach, H. (2005) · Skin Research and Technology · doi:10.1111/j.1600-0846.2005.00107.x · Cited by 171 · cited 2×
“Silicon can be used for the production of solid [1,3,32,33], hollow [14,15,18,34], and coated MNs [34].”
BackgroundDonnelly, R. F., Singh, T. R. R., Alkilani, A. Z., McCrudden, M., O’Neill, S., O’Mahony, C., Armstrong, K., McLoone, N., Kole, P. L., & Woolfson, A. D. (2013) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2013.04.045 · Cited by 171 · cited 4×
“However, the microbial count was higher in the viable epidermis of skin punctured with MN array than hypodermic needle which indicates that there is a possibility of skin infection following application of Gantrez MNs which is limited to the epidermal layer [62].”
BackgroundInfluentialGrayson, A. C. R., Voskerician, G., Lynn, A., Anderson, J. M., Cima, M. J., & Langer, R. (2004) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/1568562041959991 · Cited by 167
Micromolding for ceramic microneedle arrays
Bystrova, S., & Lüttge, R. (2010) · Microelectronic Engineering · doi:10.1016/j.mee.2010.12.067 · Cited by 167 · cited 2×
“However, these materials may show brittle fracture on manual application in the skin and may induce skin irritation [49].”
BackgroundKim, J., Han, M.-R., Kim, Y., Shin, S.-W., Nam, S.-Y., & Park, J. (2016) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2016.06.006 · Cited by 166 · cited 1×
“saccharides include hydroxypropyl methylcellulose [56], hyaluronic”
McGrath, M. G., Vučen, S. R., Vrdoljak, A., Kelly, A., O’Mahony, C., Crean, A. M., & Moore, A. (2013) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2013.04.023 · Cited by 161 · cited 1×
“actose [63] produce MNs that have the ability to pierce through”
BackgroundIntradermal delivery of STAT3 siRNA to treat melanoma via dissolving microneedles
Pan, J., Ruan, W., Qin, M., Long, Y., Wan, T., Yu, K., Zhai, Y., Wu, C., & Xu, Y. (2018) · Scientific Reports · doi:10.1038/s41598-018-19463-2 · Cited by 158 · cited 1×
“Another study demonstrated the efficacy of system for cancer therapy, wherein in vivo topical application of STAT3 siRNA polyethylenimine complex dissolving MNs effectively suppressed the growth of melanoma by silencing STAT3 gene [91].”
BackgroundBioresponsive Microneedles with a Sheath Structure for H2O2and pH Cascade‐Triggered Insulin Delivery
Zhang, Y., Wang, J., Yu, J., Wen, D., Kahkoska, A. R., Lü, Y., Zhang, X., Buse, J. B., & Gu, Z. (2018) · Small · doi:10.1002/smll.201704181 · Cited by 157
Painless Drug Delivery Through Microneedle-Based Transdermal Patches Featuring Active Infusion
Roxhed, N., Samel, B., Nordquist, L., Griss, P., & Stemme, G. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.906492 · Cited by 151 · cited 1×
“The sensation of pain is found to be minimal during infusion with hollow silicon MNs [76].”
BackgroundMicroporation applications for enhancing drug delivery
Banga, A. K. (2009) · Expert Opinion on Drug Delivery · doi:10.1517/17425240902841935 · Cited by 149 · cited 1×
“The main limitations of silicon are its high cost, intricate fabrication requirements, long fabrication times, and complex multistep processing [35].”
BackgroundChen, M., Lai, K.-Y., Ling, M.-H., & Lin, C.-W. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.11.004 · Cited by 144 · cited 1×
“5-fold dose sparing advantage, these MNs also demonstrated superior immunogenicity to ovalbumin and chitosan solution [87].”
BackgroundNorman, J. J., Brown, M. R., Raviele, N. A., Prausnitz, M. R., & Felner, E. I. (2013) · Pediatric Diabetes · doi:10.1111/pedi.12031 · Cited by 142 · cited 1×
“the determination of Tmax of insulin [98].”
Rapidly separating microneedles for transdermal drug delivery
Zhu, D., Wang, Q. L., Liu, X. B., & Guo, X. D. (2016) · Acta Biomaterialia · doi:10.1016/j.actbio.2016.06.005 · Cited by 138 · cited 1×
“The remnant patches can be peeled off against the skin [29,30].”
BackgroundRapidly Dissolvable Microneedle Patches for Transdermal Delivery of Exenatide
Zhu, Z., Luo, H., Lu, W., Luan, H., Wu, Y., Luo, J. C., Wang, Y., Pi, J., Lim, C. Y., & Wang, H. (2014) · Pharmaceutical Research · doi:10.1007/s11095-014-1424-1 · Cited by 133 · cited 2×
“Transepidermal water loss (TEWL) determinations validate that the resealing time of the pores is within 12 hours [30].”
BackgroundFabrication of microneedle array using LIGA and hot embossing process
Moon, S. J., Lee, S. S., Lee, H. S., & Kwon, T. H. (2005) · Microsystem Technologies · doi:10.1007/s00542-004-0446-8 · Cited by 129 · cited 1×
“Subsequently, the developed array is exposure to inclined rays in order to provide the desired MN shape with the conduit [67].”
MethodGupta, J., Felner, E. I., & Prausnitz, M. R. (2011) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2010.0204 · Cited by 128 · cited 1×
“The pulled needles are then beveled at a 30-degree angle using a beveller-producing hollow MNs with an oval-shaped opening [11,13,22].”
MethodDuong, H. T. T., Kim, N. W., Thambi, T., Phan, V. H. G., Lee, M. S., Yin, Y., Jeong, J. H., & Lee, D. S. (2017) · Journal of Controlled Release · doi:10.1016/j.jconrel.2017.11.025 · Cited by 126 · cited 1×
“Generation of antigenspecific robust immune responses in BALB/c mice confirmed the release of DNA vaccines through the system [81].”
BackgroundMatsuo, K., Yokota, Y., Zhai, Y., Quan, Y., Kamiyama, F., Mukai, Y., Okada, N., & Nakagawa, S. (2012) · Journal of Controlled Release · doi:10.1016/j.jconrel.2012.01.033 · Cited by 125 · cited 2×
“Sodium salts of hyaluronate produces MNs which successfully pierce the skin at lengths from 200 to 800 mm as confirmed by skin impedance measurement [85].”
Backgroundvan der Maaden, K., Heuts, J., Camps, M. G. M., Pontier, M., van Scheltinga, A. G. T. T., Jiskoot, W., OSSENDORP, F. A., & Bouwstra, J. A. (2017) · Journal of Controlled Release · doi:10.1016/j.jconrel.2017.11.035 · Cited by 115 · cited 1×
“responses were observed, postadministration, with much lower volumes as compared to conventional intradermal immunization [79].”
BackgroundQuinn, H. L., Bonham, L., Hughes, C. M., & Donnelly, R. F. (2015) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.24563 · Cited by 115 · cited 1×
“These MNs after application completely dissolve or degrade in the skin, thereby releasing the encapsulated drug payload, and leave behind no hazardous remnants [26,27].”
BackgroundA Photolithographic Approach to Polymeric Microneedles Array Fabrication
Dardano, P., Caliò, A., Palma, V. D., Bevilacqua, M., Matteo, A. D., & Stefano, L. D. (2015) · Materials · doi:10.3390/ma8125484 · Cited by 113 · cited 1×
“In the final step, also known as etching step, the drawing made of photoresist is then reproduced on the substrate with wet or dry chemical attack [66].”
BackgroundFabrication of Polymer Microneedles Using a Two-Photon Polymerization and Micromolding Process
Gittard, S. D., Ovsianikov, A., Monteiro-Riviere, N. A., Lusk, J., Morel, P., Minghetti, P., Lenardi, C., Chichkov, B. N., & Narayan, R. J. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300211 · Cited by 110
Lahiji, S. F., Seo, S. H., Kim, S., Dangol, M., Shim, J., Li, C. G., Ma, Y., Lee, C., Kang, G., Yang, H., et al. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.03.019 · Cited by 107 · cited 1×
“Dissolving MN patch encapsulating valproic acid delivered the drug with higher accuracy than topical application, and stimulated wound reepithelialization signals which are involved in regrowth of hair follicles [89].”
BackgroundPulsed laser deposition of antimicrobial silver coating on Ormocer® microneedles
Gittard, S. D., Narayan, R. J., Jin, C., Ovsianikov, A., Chichkov, B. N., Monteiro-Riviere, N. A., Stafslien, S. J., & Chisholm, B. J. (2009) · Biofabrication · doi:10.1088/1758-5082/1/4/041001 · Cited by 105
The Use of Silicon Microfabrication Technology in Painless Blood Glucose Monitoring
Smart, W. H., & Subramanian, K. (2000) · Diabetes Technology & Therapeutics · doi:10.1089/15209150050501961 · Cited by 101 · cited 5×
“Silicon can be used for the production of solid [1,3,32,33], hollow [14,15,18,34], and coated MNs [34].”
BackgroundMethodInfluentialAssad, M., Lemieux, N., Rivard, C., & Yahia, L. (1999) · PubMed · Cited by 100
Structural characterization and in-vivo reliability evaluation of silicon microneedles
O’Mahony, C. (2014) · Biomedical Microdevices · doi:10.1007/s10544-014-9836-6 · Cited by 100 · cited 3×
“Risk involving silicon MNs includes practicable fracture in the skin causing safety issues [33].”
BackgroundMicroneedle Electrodes Toward an Amperometric Glucose‐Sensing Smart Patch
Invernale, M. A., Tang, B. C., York, R. L., Le, L., Hou, D. Y., & Anderson, D. G. (2014) · Advanced Healthcare Materials · doi:10.1002/adhm.201300142 · Cited by 99 · cited 1×
“Most common metals used for the production of MNs include stainless steel [2,19,25,36,37], titanium [24,38], palladium [39], nickel [39,40], platinum [41], alloys [39,42], and gold [39].”
BackgroundHoang, M., Ita, K. B., & Bair, D. A. (2015) · Pharmaceutics · doi:10.3390/pharmaceutics7040379 · Cited by 92 · cited 1×
“The formulation can be in the form of a topical patch or a semisolid composition like gel, ointment, cream, or lotion [20,21].”
Backgroundvan der Maaden, K., Trietsch, S. J., Kraan, H., Varypataki, E. M., Romeijn, S. G., Zwier, R., van der Linden, H. J., Kersten, G. F. A., Hankemeier, T., Jiskoot, W., et al. (2014) · Pharmaceutical Research · doi:10.1007/s11095-013-1288-9 · Cited by 90 · cited 4×
“The hollow type [13,16,22] is commonly fabricated.”
BackgroundInfluentialCole, G., Ali, A., McCrudden, C. M., McBride, J. W., McCaffrey, J., Robson, T., Kett, V. L., Dunne, N., Donnelly, R. F., & McCarthy, H. O. (2018) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2018.02.029 · Cited by 90 · cited 1×
“It was superior to the conventional intramuscular injection [92].”
BackgroundDhar, N., Akhlaghi, S. P., & Tam, K. C. (2011) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2011.07.022 · Cited by 88
Yoon, Y., Lee, G., Yoo, K., & Lee, J.-B. (2013) · Sensors · doi:10.3390/s131216672 · Cited by 85 · cited 1×
“This is due to the reduced rate at bottom, attributed to the lack of fluid motion to replenish it [6,70].”
BackgroundNorman, J. J., Choi, S.-O., Tong, N. T., Aiyar, A. R., Patel, S. R., Prausnitz, M. R., & Allen, M. G. (2013) · Biomedical Microdevices · doi:10.1007/s10544-012-9717-9 · Cited by 85 · cited 3×
“Metals are utilized for production of solid [2,20,36,37], hollow [19,39,40], and as base of the coated MNs [5,24,25].”
BackgroundKim, J. H., Shin, J. U., Kim, S. H., Noh, J. Y., Kim, H. R., Lee, J., Chu, H., Jeong, K. Y., Park, K. H., Kim, J. D., et al. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.10.013 · Cited by 84 · cited 1×
“SCIT (10 mg) and placebo failed to show effects [88].”
BackgroundPotential of hydrogel-forming and dissolving microneedles for use in paediatric populations
Caffarel–Salvador, E., Tuan-Mahmood, T.-M., McElnay, J. C., McCarthy, H. O., Mooney, K. M., Woolfson, A. D., & Donnelly, R. F. (2015) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2015.04.076 · Cited by 82 · cited 10×
“PVP as a material for fabrication of MNs is inert and dissolves in the skin which leaves no hazardous wastes after application.”
BackgroundMethodInfluentialHutton, A. R. J., Quinn, H. L., McCague, P. J., Jarrahian, C., Rein‐Weston, A., Coffey, P. S., Gerth‐Guyette, E., Zehrung, D., Larrañeta, E., & Donnelly, R. F. (2018) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2018.02.031 · Cited by 81 · cited 1×
“Authors demonstrated the potential of these MNs to prevent bleeding, attributed to vitamin K deficiency [93].”
BackgroundDoraiswamy, A., Ovsianikov, A., Gittard, S. D., Monteiro-Riviere, N. A., Crombez, R. C., Montalvo, E., Shen, W. C., Chichkov, B. N., & Narayan, R. J. (2010) · Journal of Nanoscience and Nanotechnology · doi:10.1166/jnn.2010.2636 · Cited by 78 · cited 2×
“After completion of fabrication of the MN, the nonirradiated resin is washed away using appropriate solvent and is cured using ultraviolet light [9,10,52].”
MethodKatsumi, H., Liu, S., Tanaka, Y., Hitomi, K., Hayashi, R., Hirai, Y., Kusamori, K., Quan, Y., Kamiyama, F., Sakane, T., et al. (2012) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.23136 · Cited by 74 · cited 2×
“acid [57], carboxymethycellulose (CMC), alginates, or synthetic polymers like poly (methylvinylether/maleic anhydride) [28] i.”
BackgroundMethodMansoor, I., Liu, Y., Häfeli, U. O., & Stoeber, B. (2013) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/23/8/085011 · Cited by 73 · cited 1×
“They are utilized for infusion of liquid formulations into the skin, or diffusion from a drug reservoir [16,18,22,23].”
BackgroundSpierings, E. L. H., Brandes, J. L., Kudrow, D., Weintraub, J., Schmidt, P. C., Kellerman, D. J., & Tepper, S. J. (2017) · Cephalalgia · doi:10.1177/0333102417737765 · Cited by 73
Ronnander, P., Simon, L., Spilgies, H., Koch, A., & Scherr, S. (2017) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2017.11.031 · Cited by 72 · cited 1×
“tion of 72 ng/mL, for nearly 7 hours [96].”
BackgroundShirkhanzadeh, M. (2005) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-005-6444-2 · Cited by 65 · cited 5×
“Advantage of using metals is their desirable mechanical properties and high tensile strength [43] which enables easy penetration through SC [5,20].”
BackgroundInfluentialKim, H.-G., Gater, D. L., & Kim, Y. (2017) · Drug Delivery and Translational Research · doi:10.1007/s13346-017-0460-x · Cited by 64 · cited 1×
“Vitamin D3 nanoparticles, when administered as a coating along with PLGA on MNs, completely dissolved in the intradermal region of the skin, and exhibited superior release into plasma, compared to ointment based formulation of the same [80].”
MethodDissolvable layered microneedles with core-shell structures for transdermal drug delivery
Wang, Q. L., Zhang, X. P., Chen, B. Z., & Guo, X. D. (2017) · Materials Science and Engineering C · doi:10.1016/j.msec.2017.11.009 · Cited by 63 · cited 1×
“geneous MNs that required more than 120 seconds to touch the same efficiency [97].”
BackgroundPamornpathomkul, B., Niyomtham, N., Yingyongnarongkul, B., Prasitpuriprecha, C., Rojanarata, T., Ngawhirunpat, T., & Opanasopit, P. (2017) · AAPS PharmSciTech · doi:10.1208/s12249-017-0855-5 · Cited by 54
Self-setting bioceramic microscopic protrusions for transdermal drug delivery
Cai, B., Xia, W., Bredenberg, S., & Engqvist, H. (2014) · J. Mater. Chem. B · doi:10.1039/c4tb00764f · Cited by 52 · cited 2×
“This avoids the risk associated with remnants of the material in the skin which is present in metallic MNs [54].”
BackgroundExendin-4–encapsulated dissolving microneedle arrays for efficient treatment of type 2 diabetes
Lahiji, S. F., Jang, Y., Huh, I., Yang, H., Jang, M., & Jung, H. (2018) · Scientific Reports · doi:10.1038/s41598-018-19789-x · Cited by 44 · cited 1×
“Another study demonstrated that the efficiency of reduction of blood glucose level in diabetic mice, with exendin-4-encapsulated dissolving MNs, was similar to that of a subcutaneous injection [94].”
ResultThe Influence of Solid Microneedles on the Transdermal Delivery of Selected Antiepileptic Drugs
Nguyen, J., Ita, K. B., Morra, M. J., & Popova, I. E. (2016) · Pharmaceutics · doi:10.3390/pharmaceutics8040033 · Cited by 43 · cited 2×
“32 mg/cm(2)/ h), when applied on porcine skin as 20% and 30% ethanol solutions, respectively, after MN roller treatment, compared to solo application [74].”
MethodRobust penetrating microelectrodes for neural interfaces realized by titanium micromachining
McCarthy, P. T., Otto, K. J., & Rao, M. P. (2011) · Biomedical Microdevices · doi:10.1007/s10544-011-9519-5 · Cited by 42 · cited 2×
“Thus titanium possesses higher reliability, tolerance, and safety compared to conventional silicon devices [38].”
BackgroundFabrication and characterization of novel microneedles made of a polystyrene solution
Luangveera, W., Jiruedee, S., Mama, W., Chiaranairungroj, M., Pimpin, A., Palaga, T., & Srituravanich, W. (2015) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2015.06.009 · Cited by 42 · cited 1×
“GantrezR [28], polystyrene [58], polyvinyl alcohol, polyvinylpyrroli-”
Shin, J.-H., Park, J.-K., Lee, D., Quan, F., Song, C., & Kim, Y. (2015) · PLoS ONE · doi:10.1371/journal.pone.0130684 · Cited by 20
Wang, S. X., Wen, X., Bell, C., & Appiah, S. S. (2018) · Molecular Medicine Reports · doi:10.3892/mmr.2018.8396 · Cited by 16
Álvarez, A. L., Blanco-Méndez, J., Varela‐Patiño, P., & Martín‐Biedma, B. (2010) · Journal of Biomaterials Science Polymer Edition · doi:10.1163/092050610x486937 · Cited by 16
Characterization of Individual Microneedles Formed on Alloy Surfaces by Femtosecond Laser Ablation
Bhattacharya, S., Kam, D.-H., Song, L., & Mazumder, J. (2012) · Metallurgical and Materials Transactions A · doi:10.1007/s11661-012-1152-2 · Cited by 16 · cited 1×
“Most common metals used for the production of MNs include stainless steel [2,19,25,36,37], titanium [24,38], palladium [39], nickel [39,40], platinum [41], alloys [39,42], and gold [39].”
BackgroundNguyen, H. X., & Banga, A. K. (2018) · Pharmaceutical Research · doi:10.1007/s11095-018-2369-6 · cited 1×
“transdermal delivery of methotrexate in and across the skin [95].”
Background
Cited by
Makvandi, P., Kirkby, M., Hutton, A. R. J., Shabani, M., Yiu, C. K. Y., Baghbantaraghdari, Z., Jamaledin, R., Carlotti, M., Mazzolai, B., Mattoli, V., et al. (2021) · Nano-Micro Letters · doi:10.1007/s40820-021-00611-9 · Cited by 455
Microneedle for transdermal drug delivery: current trends and fabrication
Jung, J. H., & Jin, S. G. (2021) · Journal of Pharmaceutical Investigation · doi:10.1007/s40005-021-00512-4 · Cited by 416
Lyu, S., Dong, Z., Xu, X., Bei, H.-P., Yuen, H.-Y., James Cheung, C.-W., Wong, M.-S., He, Y., & Zhao, X. (2023) · Bioactive Materials · doi:10.1016/j.bioactmat.2023.04.003 · Cited by 266
Microneedle-Based Delivery: An Overview of Current Applications and Trends
Guillot, A. J., Cordeiro, A. S., Donnelly, R. F., Montesinos, M. C., Garrigues, T. M., & Melero, A. (2020) · Pharmaceutics · doi:10.3390/pharmaceutics12060569 · Cited by 254
Metadata
- Authors
- Dharadhar, S., Majumdar, A., Dhoble, S., & Patravale, V.
- Venue
- Drug Development and Industrial Pharmacy
- Publisher
- Informa UK Limited
- Published
- 2018-11-27
- Volume
- 45
- Issue
- 2
- Pages
- 188-201
- ISSN
- 0363-9045 (ISSN-L)
- 1520-5762
- OpenAlex
- W2898611803
- Cited by
- 188
- References
- 90
- FWCI
- 1.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.