Mass Spectrometry, Review of the Basics: Electrospray, MALDI, and Commonly Used Mass Analyzers
The DOI matches its Crossref record; 58 of the 58 references it cites were found in a registry or an index.
Abstract
Mass spectrometry (MS) has progressed to become a powerful analytical tool for both quantitative and qualitative applications. The first mass spectrometer was constructed in 1912 and since then it has developed from only analyzing small inorganic molecules to biological macromolecules, practically with no mass limitations. Proteomics research, in particular, increasingly depends on MS technologies. The ability of mass spectrometry analyzing proteins and other biological extracts is due to the advances gained through the development of soft ionization techniques such as electrospray ionization (ESI) and matrix-assisted laser desorption ionization (MALDI) that can transform biomolecules into ions. ESI can efficiently be interfaced with separation techniques enhancing its role in the life and health sciences. MALDI, however, has the advantage of producing singly charges ions of peptides and proteins, minimizing spectral complexity. Regardless of the ionization source, the sensitivity of a mass spectrometer is related to the mass analyzer where ion separation occurs. Both quadrupole and time of flight (ToF) mass analyzers are commonly used and they can be configured together as QToF tandem mass spectrometric instruments. Tandem mass spectrometry (MS/MS), as the name indicates, is the result of performing two or more sequential separations of ions usually coupling two or more mass analyzers. Coupling a quadrupole and time of flight resulted in the production of high-resolution mass spectrometers (i.e., Q-ToF). This article will historically introduce mass spectrometry and summarizes the advantages and disadvantages of ESI and MALDI along with quadrupole and ToF mass analyzers, including the technical marriage between the two analyzers. This article is educational in nature and intended for graduate students and senior biochemistry students as well as chemists and biochemists who are not familiar with mass spectrometry and would like to learn the basics; it is not intended for mass spectrometry experts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltons
Karas, M., & Hillenkamp, F. (1988) · Analytical Chemistry · doi:10.1021/ac00171a028 · Cited by 5,637
Mass Spectrometry Sampling Under Ambient Conditions with Desorption Electrospray Ionization
Takáts, Z., Wiseman, J. M., Gologan, B., & Cooks, R. G. (2004) · Science · doi:10.1126/science.1104404 · Cited by 3,324
Protein and polymer analyses up to m/z 100 000 by laser ionization time‐of‐flight mass spectrometry
Tanaka, K., Waki, H., Ido, Y., Akita, S., Yoshida, Y., Yoshida, T., & Matsuo, T. (1988) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290020802 · Cited by 3,175
Electrospray ion source. Another variation on the free-jet theme
Yamashita, M., & Fenn, J. B. (1984) · The Journal of Physical Chemistry · doi:10.1021/j150664a002 · Cited by 2,082
Matrix-assisted laser desorption/ionization mass spectrometry of biopolymers.
Hillenkamp, F., Karas, M., Beavis, R. C., & Chait, B. T. (1991) · Analytical Chemistry · doi:10.1021/ac00024a716 · Cited by 1,930 · cited 1×
“Nonetheless, much of the credit given to the development of MALDI should also go to Michael Karas and Franz Hillenkamp, who developed the ideas of laser desorption techniques (21, 24, 25).”
BackgroundJames, A. T., & Martin, A. J. P. (1952) · Biochemical Journal · doi:10.1042/bj0500679 · Cited by 1,822
Dole, M., Mack, L. L., Hines, R. L., Mobley, R. C., Ferguson, L. D., & Alice, M. B. (1968) · The Journal of Chemical Physics · doi:10.1063/1.1670391 · Cited by 1,613
Electrospray interface for liquid chromatographs and mass spectrometers
Whitehouse, C. M., Dreyer, R. N., Yamashita, M., & Fenn, J. B. (1985) · Analytical Chemistry · doi:10.1021/ac00280a023 · Cited by 1,512
Cooks, R. G., Ouyang, Z., Takats, Z., & Wiseman, J. M. (2006) · Science · doi:10.1126/science.1119426 · Cited by 1,474
On the evaporation of small ions from charged droplets
Iribarne, J. V., & Thomson, B. A. (1976) · The Journal of Chemical Physics · doi:10.1063/1.432536 · Cited by 1,281
Cited by
Analytical Methods in Untargeted Metabolomics: State of the Art in 2015
Alonso, A., Marsal, S., & JuliÃ, A. (2015) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2015.00023 · Cited by 681
In Situ, Time-Resolved, and Mechanistic Studies of Metal–Organic Framework Nucleation and Growth
Van Vleet, M. J., Weng, T., Li, X., & Schmidt, J. R. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00582 · Cited by 610
Pratt, K. A., & Prather, K. A. (2012) · Mass Spectrometry Reviews · doi:10.1002/mas.20330 · Cited by 286
Quantitative Mass Spectrometry-Based Proteomics: An Overview
Rozanova, S., Barkovits, K., Nikolov, M., Schmidt, C., Urlaub, H., & Marcus, K. (2021) · Methods in Molecular Biology · doi:10.1007/978-1-0716-1024-4_8 · Cited by 275
Spraggins, J. M., Djambazova, K. V., Rivera, E. S., Migas, L. G., Neumann, E. K., Fuetterer, A., Suetering, J., Goedecke, N., Ly, A., Van de Plas, R., et al. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b03612 · Cited by 237
Global chemical analysis of biology by mass spectrometry
Aksenov, A. A., da Silva, R., Knight, R., Lopes, N. P., & Dorrestein, P. C. (2017) · Nature Reviews Chemistry · doi:10.1038/s41570-017-0054 · Cited by 230
Dorta, E., González, M., Lobo, M. G., Sánchez-Moreno, C., & de Ancos, B. (2014) · Food Research International · doi:10.1016/j.foodres.2014.01.012 · Cited by 229
Christie, A. E., Stemmler, E. A., & Dickinson, P. S. (2010) · Cellular and Molecular Life Sciences · doi:10.1007/s00018-010-0482-8 · Cited by 216
Sullivan, G. L., Gallardo, J. D., Jones, E. W., Hollliman, P. J., Watson, T. M., & Sarp, S. (2020) · Chemosphere · doi:10.1016/j.chemosphere.2020.126179 · Cited by 179
Mass Cytometry Imaging for the Study of Human Diseases—Applications and Data Analysis Strategies
Baharlou, H., Canete, N. P., Cunningham, A. L., Harman, A. N., & Patrick, E. (2019) · Frontiers in Immunology · doi:10.3389/fimmu.2019.02657 · Cited by 177
Mass Spectrometry, Review of the Basics: Ionization
Awad, H., Khamis, M. M., & El-Aneed, A. (2015) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2014.954046 · Cited by 176
“High- and low-resolution MS instruments currently exist on the market and all instruments contain three main elements: the ionization source, the mass analyzer, and the detector (8).”
BackgroundSelf-citationQuantitative Mass Spectrometry-Based Proteomics: An Overview
Nikolov, M., Schmidt, C., & Urlaub, H. (2012) · Methods in Molecular Biology · doi:10.1007/978-1-61779-885-6_7 · Cited by 167
Analysis of short-chain fatty acids in human feces: A scoping review
Primec, M., Mičetić-Turk, D., & Langerholc, T. (2017) · Analytical Biochemistry · doi:10.1016/j.ab.2017.03.007 · Cited by 165
Omics for Bioprospecting and Drug Discovery from Bacteria and Microalgae
Maghembe, R., Damian, D., Makaranga, A., Nyandoro, S. S., Lyantagaye, S. L., Kusari, S., & Hatti-Kaul, R. (2020) · Antibiotics · doi:10.3390/antibiotics9050229 · Cited by 66
“The fascinating aspect of MALDI-MS is the suitability for analyzing macromolecules such as polysaccharides, lipids, or proteins or nucleic acids with desirable resolution without disruption of their integrity [117,118].”
BackgroundA Comparison of Common Mass Spectrometry Approaches for Paleoproteomics
Cleland, T. P., & Schroeter, E. R. (2018) · Journal of Proteome Research · doi:10.1021/acs.jproteome.7b00703 · Cited by 62
Phelps, C., Hardwick, E. K., Couch, A. N., & Davidson, J. T. (2025) · Journal of Forensic Sciences · doi:10.1111/1556-4029.70084 · Cited by 6
“However, traditional full scan EI-MS provides poor sensitivity over a wide mass range due to the operation of the single quadrupole mass analyzer [ 44 ].”
Metadata
- Authors
- El-Aneed, A., Cohen, A., & Banoub, J.
- Venue
- Applied Spectroscopy Reviews
- Publisher
- Informa UK Limited
- Published
- 2009-04
- Volume
- 44
- Issue
- 3
- Pages
- 210-230
- ISSN
- 0570-4928 (ISSN-L)
- 1520-569X
- OpenAlex
- W2094603341
- Cited by
- 386
- References
- 58
- FWCI
- 5.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.