Mass Spectrometry, Review of the Basics: Electrospray, MALDI, and Commonly Used Mass Analyzers
The DOI matches its Crossref record; 58 of the 58 references it cites were found in a registry or an index.
Abstract
Mass spectrometry (MS) has progressed to become a powerful analytical tool for both quantitative and qualitative applications. The first mass spectrometer was constructed in 1912 and since then it has developed from only analyzing small inorganic molecules to biological macromolecules, practically with no mass limitations. Proteomics research, in particular, increasingly depends on MS technologies. The ability of mass spectrometry analyzing proteins and other biological extracts is due to the advances gained through the development of soft ionization techniques such as electrospray ionization (ESI) and matrix-assisted laser desorption ionization (MALDI) that can transform biomolecules into ions. ESI can efficiently be interfaced with separation techniques enhancing its role in the life and health sciences. MALDI, however, has the advantage of producing singly charges ions of peptides and proteins, minimizing spectral complexity. Regardless of the ionization source, the sensitivity of a mass spectrometer is related to the mass analyzer where ion separation occurs. Both quadrupole and time of flight (ToF) mass analyzers are commonly used and they can be configured together as QToF tandem mass spectrometric instruments. Tandem mass spectrometry (MS/MS), as the name indicates, is the result of performing two or more sequential separations of ions usually coupling two or more mass analyzers. Coupling a quadrupole and time of flight resulted in the production of high-resolution mass spectrometers (i.e., Q-ToF). This article will historically introduce mass spectrometry and summarizes the advantages and disadvantages of ESI and MALDI along with quadrupole and ToF mass analyzers, including the technical marriage between the two analyzers. This article is educational in nature and intended for graduate students and senior biochemistry students as well as chemists and biochemists who are not familiar with mass spectrometry and would like to learn the basics; it is not intended for mass spectrometry experts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltons
Karas, M., & Hillenkamp, F. (1988) · Analytical Chemistry · doi:10.1021/ac00171a028 · Cited by 5,637
Mass Spectrometry Sampling Under Ambient Conditions with Desorption Electrospray Ionization
Takáts, Z., Wiseman, J. M., Gologan, B., & Cooks, R. G. (2004) · Science · doi:10.1126/science.1104404 · Cited by 3,324
Protein and polymer analyses up to m/z 100 000 by laser ionization time‐of‐flight mass spectrometry
Tanaka, K., Waki, H., Ido, Y., Akita, S., Yoshida, Y., Yoshida, T., & Matsuo, T. (1988) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290020802 · Cited by 3,175
Electrospray ion source. Another variation on the free-jet theme
Yamashita, M., & Fenn, J. B. (1984) · The Journal of Physical Chemistry · doi:10.1021/j150664a002 · Cited by 2,082
Matrix-assisted laser desorption/ionization mass spectrometry of biopolymers.
Hillenkamp, F., Karas, M., Beavis, R. C., & Chait, B. T. (1991) · Analytical Chemistry · doi:10.1021/ac00024a716 · Cited by 1,930 · cited 1×
“Nonetheless, much of the credit given to the development of MALDI should also go to Michael Karas and Franz Hillenkamp, who developed the ideas of laser desorption techniques (21, 24, 25).”
BackgroundJames, A. T., & Martin, A. J. P. (1952) · Biochemical Journal · doi:10.1042/bj0500679 · Cited by 1,822
Dole, M., Mack, L. L., Hines, R. L., Mobley, R. C., Ferguson, L. D., & Alice, M. B. (1968) · The Journal of Chemical Physics · doi:10.1063/1.1670391 · Cited by 1,613
Electrospray interface for liquid chromatographs and mass spectrometers
Whitehouse, C. M., Dreyer, R. N., Yamashita, M., & Fenn, J. B. (1985) · Analytical Chemistry · doi:10.1021/ac00280a023 · Cited by 1,512
Cooks, R. G., Ouyang, Z., Takats, Z., & Wiseman, J. M. (2006) · Science · doi:10.1126/science.1119426 · Cited by 1,474
On the evaporation of small ions from charged droplets
Iribarne, J. V., & Thomson, B. A. (1976) · The Journal of Chemical Physics · doi:10.1063/1.432536 · Cited by 1,281
Clauser, K. R., Baker, P., & Burlingame, A. L. (1999) · Analytical Chemistry · doi:10.1021/ac9810516 · Cited by 1,093
Mass spectrometry: principles and applications
(2008) · Choice Reviews Online · doi:10.5860/choice.45-4389 · Cited by 780
Mass spectrometry: principles and applications
(1997) · Choice Reviews Online · doi:10.5860/choice.35-1527 · Cited by 758
Chemical Ionization Mass Spectrometry. I. General Introduction
Munson, M. S. B., & Field, F. H. (1966) · Journal of the American Chemical Society · doi:10.1021/ja00964a001 · Cited by 749
An introduction to quadrupole–time‐of‐flight mass spectrometry
Chernushevich, I. V., Loboda, A. V., & Thomson, B. A. (2001) · Journal of Mass Spectrometry · doi:10.1002/jms.207 · Cited by 705
Recent advancements in surface-enhanced laser desorption/ionization-time of flight-mass spectrometry
Merchant, M., & Weinberger, S. R. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000401)21:6<1164::aid-elps1164>3.0.co;2-0 · Cited by 693
A brief overview of the present status of the mechanisms involved in electrospray mass spectrometry
Kebarle, P. (2000) · Journal of Mass Spectrometry · doi:10.1002/1096-9888(200007)35:7<804::aid-jms22>3.0.co;2-q · Cited by 675
New desorption strategies for the mass spectrometric analysis of macromolecules
Hutchens, T. W., & Yip, T. (1993) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290070703 · Cited by 621
Karas, M., Gl�ckmann, M., & Sch�fer, J. (2000) · Journal of Mass Spectrometry · doi:10.1002/(sici)1096-9888(200001)35:1<1::aid-jms904>3.0.co;2-0 · Cited by 614
Fast atom bombardment of solids as an ion source in mass spectrometry
Barber, M., Bordoli, R. S., Sedgwick, R. D., & Tyler, A. N. (1981) · Nature · doi:10.1038/293270a0 · Cited by 582
Negative ion production with the electrospray ion source
Yamashita, M., & Fenn, J. B. (1984) · The Journal of Physical Chemistry · doi:10.1021/j150664a046 · Cited by 581
Quadrupole storage mass spectrometry
March, R. E., Hughes, R. J., & Roberts, A. D. (1991) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)82582-9 · Cited by 535
Micro-electrospray mass spectrometry: Ultra-high-sensitivity analysis of peptides and proteins
Emmett, M. R., & Caprioli, R. M. (1994) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(94)85001-1 · Cited by 510
New approach to the mass spectroscopy of non-volatile compounds
Torgerson, D. F., Skowronski, R. P., & Macfarlane, R. D. (1974) · Biochemical and Biophysical Research Communications · doi:10.1016/0006-291x(74)90285-x · Cited by 466
Morris, H. R., Paxton, T., Dell, A., Langhorne, J., Berg, M., Bordoli, R. S., Hoyes, J., & Bateman, R. H. (1996) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19960610)10:8<889::aid-rcm615>3.0.co;2-f · Cited by 446
Atmospheric Pressure Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry
Laiko, V. V., Baldwin, M. A., & Burlingame, A. L. (2000) · Analytical Chemistry · doi:10.1021/ac990998k · Cited by 411
Hillenkamp, F., & Karas, M. (1990) · Methods in Enzymology · doi:10.1016/0076-6879(90)93420-p · Cited by 375
Brown, R. S., & Lennon, J. J. (1995) · Analytical Chemistry · doi:10.1021/ac00109a015 · Cited by 371
Kelleher, N. L., Zubarev, R. A., Bush, K., Furie, B., Furie, B. C., McLafferty, F. W., & Walsh, C. T. (1999) · Analytical Chemistry · doi:10.1021/ac990684x · Cited by 368
Selected ion fragmentation with a tandem quadrupole mass spectrometer
Yost, R. A., & Enke, C. G. (1978) · Journal of the American Chemical Society · doi:10.1021/ja00475a072 · Cited by 359
Semmes, O. J., Feng, Z., Adam, B.-L., Banez, L. L., Bigbee, W. L., Campos, D., Cazares, L. H., Chan, D. W., Grizzle, W. E., Izbicka, E., et al. (2005) · Clinical Chemistry · doi:10.1373/clinchem.2004.038950 · Cited by 343
Nano-electrospray ionization mass spectrometry: addressing analytical problems beyond routine
Karas, M., Bahr, U., & Dülcks, T. (2000) · Fresenius' Journal of Analytical Chemistry · doi:10.1007/s002160051561 · Cited by 275
Tandem mass spectrometry: dissociation of ions by collisional activation
Shukla, A. K., & Futrell, J. H. (2000) · Journal of Mass Spectrometry · doi:10.1002/1096-9888(200009)35:9<1069::aid-jms54>3.0.co;2-c · Cited by 273
Collision-induced decompositions of aromatic molecular ions
Jennings, K. R. (1968) · International Journal of Mass Spectrometry and Ion Physics · doi:10.1016/0020-7381(68)85002-8 · Cited by 263
Fast atom bombardment: A new mass spectrometric method for peptide sequence analysis
Morris, H. R., Panico, M., Barber, M., Bordoli, R. S., Sedgwick, R. D., & Tyler, A. (1981) · Biochemical and Biophysical Research Communications · doi:10.1016/0006-291x(81)91304-8 · Cited by 261
Proteomics Technologies and Challenges
Cho, W. C. S. (2007) · Genomics, Proteomics & Bioinformatics · doi:10.1016/s1672-0229(07)60018-7 · Cited by 234
Aston, F. W. (1934) · The Journal of Physical Chemistry · doi:10.1021/j150356a016 · Cited by 202
Electrospray and tandem mass spectrometry in biochemistry
GRIFFITHS, W. J., JONSSON, A. P., LIU, S., RAI, D. K., & WANG, Y. (2001) · Biochemical Journal · doi:10.1042/bj3550545 · Cited by 187
Collisional damping interface for an electrospray ionization time-of-flight mass spectrometer
Krutchinsky, A. N., Chernushevich, I. V., Spicer, V. L., Ens, W., & Standing, K. G. (1998) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(98)00027-0 · Cited by 187
Matrix-assisted laser desorption/ionization mass spectrometry of carbohydrates and glycoconjugates
Harvey, D. J. (2003) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(02)00968-5 · Cited by 187
Small volume and low flow‐rate electrospray lonization mass spectrometry of aqueous samples
Gale, D. C., & Smith, R. D. (1993) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290071111 · Cited by 176
Charge-remote fragmentations: method, mechanism and applications
Gross, M. L. (1992) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(92)85060-d · Cited by 170
Ion isolation and sequential stages of mass spectrometry in a quadrupole ion trap mass spectrometer
Louris, J. N., Brodbelt-Lustig, J. S., Graham Cooks, R., Glish, G. L., van Berkel, G. J., & McLuckey, S. A. (1990) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(90)87025-c · Cited by 167
Proteomic Analyses using an Accurate Mass and time Tag Strategy
Paša-Tolić, L., Masselon, C., Barry, R. C., Shen, Y., & Smith, R. D. (2004) · BioTechniques · doi:10.2144/04374rv01 · Cited by 163
Banoub, J. H., Newton, R. P., Esmans, E. L., Ewing, D. F., & Mackenzie, G. (2005) · Chemical Reviews · doi:10.1021/cr030040w · Cited by 159
Self-citationKendall, J. (1942) · Nature · doi:10.1038/149680a0 · Cited by 155
DNA analysis by MALDI-TOF mass spectrometry
Gut, I. G. (2004) · Human Mutation · doi:10.1002/humu.20023 · Cited by 130
Applied Electrospray Mass Spectrometry
Pramanik, B. N., Ganguly, A. K., & Gross, M. L. (2007) · Cited by 102
Chemical Ionization Mass Spectrometry
Field, F. H. (1972) · Springer eBooks · doi:10.1007/978-1-4757-0088-6_6 · Cited by 100
Direct analysis of steroid conjugates: The use of secondary ion mass spectrometry
Shackleton, C. H. L., & Straub, K. M. (1982) · Steroids · doi:10.1016/0039-128x(82)90111-8 · Cited by 66
Breaux, G. A., Green‐Church, K. B., France, A., & Limbach, P. A. (2000) · Analytical Chemistry · doi:10.1021/ac9907282 · Cited by 63
Hybrid Quadrupole/Time‐of‐Flight Mass Spectrometers for Analysis of Biomolecules
Ens, W., & Standing, K. G. (2005) · Methods in enzymology on CD-ROM/Methods in enzymology · doi:10.1016/s0076-6879(05)02002-1 · Cited by 58
Biroccio, A., Urbani, A., Massoud, R., Ilio, C. D., Sacchetta, P., Bernardini, S., Cortese, C., & Federici, G. (2004) · Analytical Biochemistry · doi:10.1016/j.ab.2004.10.002 · Cited by 57
Eicosanomics: targeted lipidomics of eicosanoids in biological systems
Balazy, M. (2004) · Prostaglandins & Other Lipid Mediators · doi:10.1016/j.prostaglandins.2004.03.003 · Cited by 50
Measuring Mass: From Positive Rays to Proteins
Sparkman, O. D. (2003) · Journal of Proteome Research · doi:10.1021/pr0308024 · Cited by 41
Measuring mass: from positive rays to proteins
(2003) · Choice Reviews Online · doi:10.5860/choice.40-2806 · Cited by 37
Purcell, A. W., & Gorman, J. J. (2001) · Journal of Immunological Methods · doi:10.1016/s0022-1759(00)00361-6 · Cited by 35
Cohen, A., Mansour, A. A. H., & Banoub, J. H. (2006) · Journal of Mass Spectrometry · doi:10.1002/jms.1023 · Cited by 22
Self-citation
Cited by
Analytical Methods in Untargeted Metabolomics: State of the Art in 2015
Alonso, A., Marsal, S., & JuliÃ, A. (2015) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2015.00023 · Cited by 681
In Situ, Time-Resolved, and Mechanistic Studies of Metal–Organic Framework Nucleation and Growth
Van Vleet, M. J., Weng, T., Li, X., & Schmidt, J. R. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00582 · Cited by 610
Pratt, K. A., & Prather, K. A. (2012) · Mass Spectrometry Reviews · doi:10.1002/mas.20330 · Cited by 286
Quantitative Mass Spectrometry-Based Proteomics: An Overview
Rozanova, S., Barkovits, K., Nikolov, M., Schmidt, C., Urlaub, H., & Marcus, K. (2021) · Methods in Molecular Biology · doi:10.1007/978-1-0716-1024-4_8 · Cited by 275
Spraggins, J. M., Djambazova, K. V., Rivera, E. S., Migas, L. G., Neumann, E. K., Fuetterer, A., Suetering, J., Goedecke, N., Ly, A., Van de Plas, R., et al. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b03612 · Cited by 237
Metadata
- Authors
- El-Aneed, A., Cohen, A., & Banoub, J.
- Venue
- Applied Spectroscopy Reviews
- Publisher
- Informa UK Limited
- Published
- 2009-04
- Volume
- 44
- Issue
- 3
- Pages
- 210-230
- ISSN
- 0570-4928 (ISSN-L)
- 1520-569X
- OpenAlex
- W2094603341
- Cited by
- 386
- References
- 58
- FWCI
- 5.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.