Effect of Different Barriers of Oxidized Regenerated Cellulose (ORC) on Cecal and Sidewall Adhesions in the Presence and Absence of Bleeding
The DOI matches its Crossref record.
Abstract
Adhesion formation after bowel surgery is a significant problem. The objective of this study was to evaluate two adhesion barriers composed of oxidized regenerated cellulose (ORC) in a model of bowel surgery, with and without bleeding. Ceca of female New Zealand White rabbits were abraded with gauze and a 3 x 5 cm patch of peritoneum and underlying muscle was excised from the right sidewall. Animals were randomized to receive no treatment, INTERCEED Barrier (Ethicon, Inc.), or neutralized INTERCEED (nTC7). ORC fabrics were applied to the excision site. Seven days later the percentage of the site and length of cecum with adhesions were estimated. The study was replicated in the presence of blood by nicking small vessels near the site sufficient to saturate the fabrics with blood. With hemostasis, the percentage of the sidewall with adhesions was reduced (p < .01) from 63.2 +/- 14.7% in controls (n = 6) to 4 +/- 2.7% with INTERCEED Barrier (n = 6) and 3 +/- 1.2% (n = 5) with nTC7. With bleeding, however, control (n = 5) levels of adhesions (67 +/- 17.5%) were reduced significantly with nTC7 (5.5 +/- 4%, n = 4; p < .01), but not INTERCEED Barrier (34.2 +/- 18.4%, n = 4). Similar trends were observed when the extent of adherent cecum was examined, since the cecum was the main site of adherence to the sidewall. However in the presence of blood, there was no effect of INTERCEED Barrier on cecal adhesions. We conclude that with hemostasis, both absorbable fabrics of ORC reduced adhesion formation between the injured cecum and abdominal sidewall. The effectiveness of INTERCEED Barrier, but not nTC7, was reduced but not eliminated in the presence of bleeding. This confirms similar observations in models of gynecologic surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Benefits and harms of adhesion barriers for abdominal surgery: a systematic review and meta-analysis
ten Broek, R. P. G., Stommel, M. W. J., Strik, C., van Laarhoven, C. J. H. M., Keus, F., & van Goor, H. (2014) · The Lancet · doi:10.1016/s0140-6736(13)61687-6 · Cited by 335
Zong, X., Li, S., Chen, E., Garlick, B., Kim, K.-S., Fang, D., Chiu, J., Zimmerman, T., Brathwaite, C., Hsiao, B. S., et al. (2004) · Annals of Surgery · doi:10.1097/01.sla.0000143302.48223.7e · Cited by 201
Singh Chandel, A. K., Ohta, S., Taniguchi, M., Yoshida, H., Tanaka, D., Omichi, K., Shimizu, A., Isaji, M., Hasegawa, K., & Ito, T. (2022) · Biomaterials Advances · doi:10.1016/j.bioadv.2022.212825 · Cited by 55
Sprayable anti-adhesive hydrogel for peritoneal macrophage scavenging in post-surgical applications
Song, W., Lee, C., Jeong, H., Kim, S., & Hwang, N. S. (2024) · Nature Communications · doi:10.1038/s41467-024-52753-0 · Cited by 37
“Moreover, there have been other limitations in developing adhesion barriers, such as dif fi culties in handling 9 , in fl ammation 10 , and inef fi cient delivery methods (Fig.”
MethodNadri, S., Rahmani, A., Hosseini, S. H., Habibizadeh, M., Araghi, M., & Mostafavi, H. (2022) · Artificial Cells, Nanomedicine, and Biotechnology · doi:10.1080/21691401.2021.1883043 · Cited by 19
Wiseman, D. M., Meidler, R., Lyahovetsky, Y., Kurman, E., Horn, S., & Nur, I. (2010) · Fertility and Sterility · doi:10.1016/j.fertnstert.2008.11.026 · Cited by 14
Self-citation
Metadata
- Authors
- D. M. Wiseman, L. G.-I.
- Venue
- Journal of Investigative Surgery
- Publisher
- Informa UK Limited
- Published
- 1999-01
- Volume
- 12
- Issue
- 3
- Pages
- 141-146
- ISSN
- 0894-1939 (ISSN-L)
- 1521-0553
- OpenAlex
- W2111254894
- Cited by
- 71
- References
- 0
- FWCI
- 1.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.