Dosimetric Comparisons of Particle Deposition and Retention in Rats and Humans
The DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.
Abstract
Much of the information on the toxicity of particulate matter (PM) comes from studies in which laboratory rats were exposed to PM by inhalation or instillation. Optimal use of these toxicologic data requires extrapolation to the human scenario. Assuming that comparable doses should cause comparable effects across species and that species respond similarly to a given dose at a target site, extrapolations only require that dose be defined and then characterized. Dose may be defined in terms of a PM indicator (e.g., particle number or mass), a respiratory region, and the time over which the dose is integrated (i.e., deposited versus retained dose and incremental versus accumulated dose). Dose must also be normalized: for example, unit of dose per body mass, respiratory region surface area, or number of alveolar macrophages. The parameters chosen to define a normalized dose can drastically affect the rat exposure concentration required to provide a normalized dose equivalent to that occurring in a human. The publicly available multiple path particle dosimetry model developed by CIIT Centers for Health Research was used to predict particle deposition and retention in rats and humans. Estimates of particle concentration and exposure duration required for a rat to receive the same dose as received by a human were obtained with consideration of daily activity levels and ambient PM size distributions. These techniques were also used to compare dose and response between rats and humans in several published studies. Results indicate that the relationship between PM dose and response may differ between rats and humans. For acute PM exposures, rats may be less susceptible to inflammatory responses than humans. For chronic exposures to high levels of PM, however, an overload of alveolar clearance in rats may cause them to become more susceptible than humans to adverse pulmonary effects. The dosimetric calculations indicate that to achieve nominally similar acute doses per surface area in rats, relative to humans undergoing moderate to high exertion, PM exposure concentrations for rats would need to be somewhat higher than for humans. Since the clearance of PM is faster from the lung of rats than humans, much higher exposure concentrations are required for the rat to simulate retained burdens. In other cases, rats will require lower exposures than humans to have comparable doses, illustrating the complexity of such analyses. To make accurate estimates of dose, it is essential to have accurate and complete information regarding exposure conditions-that is, not only concentration and duration of exposure, but also the aerosol size distribution. Establishing a firm linkage between exposure and dose requires that consideration be given to particle characteristics, definitions of dose metrics, and biological normalizing factors.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Particles usually have retention half-times of about 70 days [11, 13–15].”
From Effects from a 90-day inhalation toxicity study with cerium oxide and barium sulfate nanoparticles in rats (2017) · cites this paper as [13]
In the citing paper
“Exposure to 0.1 and 0.3 mg/m3 CeO2 resulted in clearance half-times below the expected mean value of 70 days for effective particle clearance [11, 13–15].”
From Effects from a 90-day inhalation toxicity study with cerium oxide and barium sulfate nanoparticles in rats (2017) · cites this paper as [13]
Citations
Cites
The physical characteristics of sulfur aerosols
Whitby, K. T. (1978) · Atmospheric Environment (1967) · doi:10.1016/0004-6981(78)90196-8 · Cited by 1,292 · cited 1×
“aSize distribution for human calculations from Whitby (1978). bThe size distribution for resuspended PM is based on several reported size distributions.”
MethodPulmonary Retention of Ultrafine and Fine Particles in Rats
Ferin, J., Oberdörster, G., & Penney, D. P. (1992) · American Journal of Respiratory Cell and Molecular Biology · doi:10.1165/ajrcmb/6.5.535 · Cited by 722 · cited 5×
“The first part of this section considers Utah Valley dust (UVD) instillation studies conducted in humans by Ghio and Devlin (2001) and in rats by Dye et al.”
BackgroundMethodInfluentialModels of human lung airways and their application to inhaled particle deposition
Yeh, H.-C., & Schum, G. M. (1980) · Bulletin of Mathematical Biology · doi:10.1007/bf02460796 · Cited by 717
Bermudez, E., Mangum, J. B., Wong, B. A., Asgharian, B., Hext, P. M., Warheit, D. B., & Everitt, J. I. (2004) · Toxicological Sciences · doi:10.1093/toxsci/kfh019 · Cited by 652 · cited 1×
“Consistent with Ferin et al. (2002), Bermudez et al. (2002, 2004) observed clearance half-times of 100 days for fine primary particles (0.22 µm diameter) and 395 days for ultrafine primary particles (0.021 µm diameter) in rats exposed via inhalation to TiO2 aggregates (MMAD of 1.44 µm) at a…”
ResultInfluentialRespiratory disease associated with community air pollution and a steel mill, Utah Valley.
Pope, C. A. (1989) · American Journal of Public Health · doi:10.2105/ajph.79.5.623 · Cited by 566
Concentrated Ambient Air Particles Induce Mild Pulmonary Inflammation in Healthy Human Volunteers
GHIO, A. J., KIM, C., & DEVLIN, R. B. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.162.3.9911115 · Cited by 546 · cited 11×
“The second part examines concentrated ambient particles (CAPs) inhalation studies conducted in humans by Ghio et al. (2000) and in rats by Kodavanti et al. (2000) and Clarke et al. (1999).”
BackgroundMethodResultInfluentialPossible mechanisms to explain dust overloading of the lungs
MORROW, P. (1988) · Fundamental and Applied Toxicology · doi:10.1016/0272-0590(88)90284-9 · Cited by 500 · cited 3×
“Based on this equation and consistent with Morrow (1988), the loading that would cause a doubling of the clearance halftime (a loose definition of overload) can be determined to occur at 1,000 nl/g-lung or 60 µm3/AM.”
BackgroundMethodInfluentialA Multiple-Path Model of Particle Deposition in the Rat Lung
Anjilvel, S. (1995) · Fundamental and Applied Toxicology · doi:10.1006/faat.1995.1144 · Cited by 498 · cited 1×
“Although the lung geometries differ between species, the same mathematical formulation may be used to calculate particle deposition in the rat as well as in the human lung (Anjilvel & Asgharian, 1995).”
BackgroundCorrelation between particle size, in vivo particle persistence, and lung injury
Oberdörster, G., Ferin, J., & Lehnert, B. E. (1994) · Environmental Health Perspectives · doi:10.1289/ehp.94102s5173 · Cited by 466
Wichmann, H. ‐., Spix, C., Tuch, T., Wölke, G., Peters, A., Heinrich, J., Kreyling, W. G., & Heyder, J. (2000) · PubMed · Cited by 442
Inflammatory Lung Injury after Bronchial Instillation of Air Pollution Particles
GHIO, A. J., & DEVLIN, R. B. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.164.4.2011089 · Cited by 376 · cited 17×
“Strictly speaking, the Ghio and Devlin (2001) analysis is flawed in that they only instilled the soluble fraction of UVD (∼20% of particle mass on average for 1986–1988 UVD), whereas their estimates of dose by inhalation are based on total PM10, which contains both soluble and insoluble components.”
BackgroundMethodResultInfluentialAcute pulmonary effects of ultrafine particles in rats and mice.
Oberdörster, G., Finkelstein, J. N., Johnston, C. J., Gelein, R. M., Cox, C., Baggs, R. B., & Elder, A. C. P. (2000) · PubMed · Cited by 373
Epidemiological evidence of the effects of ultrafine particle exposure
Wichmann, H.-E., & Peters, A. (2000) · Philosophical Transactions of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2000.0682 · Cited by 317 · cited 2×
“, 1994, 2000) or possibly particle number (Wichmann & Peters, 2000; Wichmann et al., 2000) may be as (or more) important than mass in determining the extent of health effects.”
BackgroundLung Particle Overload: Implications for Occupational Exposures to Particles
Oberdorster, G. (1995) · Regulatory Toxicology and Pharmacology · doi:10.1006/rtph.1995.1017 · Cited by 310 · cited 4×
“Overload has been loosely defined as the Alv burden causing a two- to four-times reduction in Alv clearance rates relative to normal clearance rates (ILSI, 2000; Oberdörster, 1995).”
BackgroundMethodInfluentialBermudez, E. (2002) · Toxicological Sciences · doi:10.1093/toxsci/70.1.86 · Cited by 284 · cited 3×
“The Alv clearance rate constants are based on the pulmonary retention and lymphatic uptake of titanium dioxide particles (MMAD = 1.44 µm, σg = 1.71) following a 13-wk exposure (6 h/day, 5 days/wk) to 10, 50, or 250 mg/m3 (Bermudez et al., 2002).”
BackgroundResultInfluentialAnatomic Models of the tracheobronchial and pulmonary regions of the rat
Yeh, H. C., Schum, G. M., & Duggan, M. T. (1979) · The Anatomical Record · doi:10.1002/ar.1091950308 · Cited by 224
Olin, S. S. (2000) · Inhalation Toxicology · doi:10.1080/08958370050029725 · Cited by 222
TOXICOKINETICS AND EFFECTS OF FIBROUS AND NONFIBROUS PARTICLES
Oberdörster, G. (2002) · Inhalation Toxicology · doi:10.1080/089583701753338622 · Cited by 221 · cited 4×
“More sophisticated multicompartment models of AM-mediated clearance, based on particle volume (Stöber et al., 1994) and particle surface area (Tran et al., 2000), exist. An important consideration addressed by Stöber et al. (1994) is that not all AM carry the same burden.”
BackgroundMethodInfluentialAlveolar septal structure in different species
Mercer, R. R., Russell, M. L., & Crapo, J. D. (1994) · Journal of Applied Physiology · doi:10.1152/jappl.1994.77.3.1060 · Cited by 190 · cited 1×
“From Mercer et al. (1994), the model assumes 4.86 × 108 alveoli in humans and 1.97 × 107 alveoli in rats.”
MethodInfluentialDye, J. A., Lehmann, J. R., McGee, J. K., Winsett, D. W., Ledbetter, A. D., Everitt, J. I., Ghio, A. J., & Costa, D. L. (2001) · Environmental Health Perspectives · doi:10.1289/ehp.01109s3395 · Cited by 188 · cited 19×
“The first part of this section considers Utah Valley dust (UVD) instillation studies conducted in humans by Ghio and Devlin (2001) and in rats by Dye et al. (2001). Under the premise that equal tissue doses might produce similar across-species responses, instilled doses are compared across species and inhalation expos…”
BackgroundMethodInfluentialOronasal distribution of respiratory airflow
Niinimaa, V., Cole, P., & Shephard, R. J. (1981) · Respiration Physiology · doi:10.1016/0034-5687(81)90089-x · Cited by 184 · cited 1×
“It has been estimated that 13% of the human population are “mouth breathers” (Niinimaa et al., 1981).”
BackgroundLung Clearance of Inhaled Insoluble and Soluble Particles
OBERDÖRSTER, G. (1988) · Journal of Aerosol Medicine · doi:10.1089/jam.1988.1.289 · Cited by 157 · cited 2×
“However, an influx of monocytes and macrophage into the alveoli occurs following acute exposures to numerous pollutants, such as PM, ozone, and NO (Oberdörster, 1988; Mercer, 1999; Driscoll & Schlesinger, 1988).”
BackgroundInfluentialSingle-breath diffusing capacity and lung volumes in small laboratory mammals
Takezawa, J., Miller, F. J., & O’Neil, J. J. (1980) · Journal of Applied Physiology · doi:10.1152/jappl.1980.48.6.1052 · Cited by 142
Particle inhalability curves for humans and small laboratory animals*1
Ménache, M. G. (1995) · The Annals of Occupational Hygiene · doi:10.1016/0003-4878(95)00002-v · Cited by 139 · cited 1×
“The MPPD model also contains an optional correction for the inhalability of particles during nasal breathing which may be applied to both humans and rats (Ménache et al., 1995).”
MethodKodavanti, U. P., Schladweiler, M. C. J., Ledbetter, A. D., Hauser, R. B., Christiani, D. C., McGee, J. K., Richards, J. H., & Costa, D. L. (2002) · Journal of Toxicology and Environmental Health · doi:10.1080/00984100290071667 · Cited by 114
The Effect of Lung Structure on Mucociliary Clearance and Particle Retention in Human and Rat Lungs
Hofmann, W. (2003) · Toxicological Sciences · doi:10.1093/toxsci/kfg075 · Cited by 111 · cited 1×
“A more detailed description of this TB clearance model appears elsewhere (Asgharian et al., 2001; Hofmann & Asgharian, 2003).”
MethodR. W. Clarke, P. J. C. (1999) · Inhalation Toxicology · doi:10.1080/089583799196781 · Cited by 105 · cited 25×
“Note that due to differences in the inhaled particle size, the rats in the Clarke et al. (1999) study were predicted to receive a greater dose than the rats in the Kodavanti et al.”
BackgroundMethodResultInfluentialCzech Air Quality Monitoring and Receptor Modeling Study
Pinto, J. P., Stevens, R. K., Willis, R. D., Kellogg, R., Mamane, Y., Novak, J., Šantroch, J., Beneš, I., Leniček, J., & Bureš, V. (1998) · Environmental Science & Technology · doi:10.1021/es970174p · Cited by 103
Miller, F. J. (2000) · Inhalation Toxicology · doi:10.1080/089583700196536 · Cited by 102 · cited 5×
“From Miller (2000), the number of alveolar macrophages (AMs) per alveolus assumed in the model is 12.3 in humans and 1.5 in rats.”
BackgroundInfluentialCorrelation between particle size, in vivo particle persistence, and lung injury.
Oberdörster, G., Ferin, J., & Lehnert, B. E. (1994) · Environmental Health Perspectives · doi:10.1289/ehp.102-1567252 · Cited by 87 · cited 1×
“Some studies suggest that particle surface area (Oberdörster et al., 1994, 2000) or possibly particle number (Wichmann & Peters, 2000; Wichmann et al., 2000) may be as (or more) important than mass in determining the extent of health effects.”
BackgroundDosimetric Adjustments for Interspecies Extrapolation of Inhaled Poorly Soluble Particles (PSP)
Jarabek, A. M., Asgharian, B., & Miller, F. J. (2005) · Inhalation Toxicology · doi:10.1080/08958370590929394 · Cited by 85 · cited 1×
“The analysis presented here is similar to Jarabek et al. (2005), but some terms are defined differently.”
MethodMucociliary clearance of insoluble particles from the tracheobronchial airways of the human lung
Asgharian, B., Hofmann, W., & Miller, F. J. (2001) · Journal of Aerosol Science · doi:10.1016/s0021-8502(00)00121-x · Cited by 82 · cited 2×
“A more detailed description of this TB clearance model appears elsewhere (Asgharian et al., 2001; Hofmann & Asgharian, 2003). Model simulations of TB clearance, presented herein, assumed tracheal mucus velocities of 1.9 mm/min in rats (Felicetti et al., 1981) and 5.5 mm/min in humans (ICRP, 1994). Clearance from the A…”
MethodInfluentialAdamson, I. Y. R., & Bowden, D. H. (1981) · Experimental Lung Research · doi:10.3109/01902148109052312 · Cited by 81 · cited 5×
“Adamson and Bowden (1981) reported less phagocytic activity in rats following instillation of 0.1-μm versus 1.0-μm latex spheres. In addition, Adamson and Bowden (1981) identified 0.1-μm spheres in Type 1 epithelial cells, free in the interstitium, and in interstitial macrophages—all of which were rarely seen for the…”
BackgroundInfluentialKodavanti, U. P. (2000) · Toxicological Sciences · doi:10.1093/toxsci/54.2.441 · Cited by 78 · cited 9×
“Interestingly, neither the healthy nor bronchitic rats in the Kodavanti et al. (2000) study showed a consistent inflammatory response, again suggesting that rats are less susceptible to CAPs effects than healthy humans.”
BackgroundMethodInfluential(1994) · Annals of the ICRP · doi:10.1177/014664539402401-303 · Cited by 65
Clearance of Particles Deposited in the Lungs
(2000) · Particle-Lung Interactions · doi:10.1201/b14423-11 · Cited by 64 · cited 1×
“Figure 6 compares the longer term clearance of particles initially deposited in the Alv region of rats and humans (Kreyling & Scheuch, 2000).”
BackgroundA Multiple-Path Model of Particle Deposition in the Rat Lung
Anjilvel, S., & Asgharian, B. (1995) · Toxicological Sciences · doi:10.1093/toxsci/28.1.41 · Cited by 63
Comparison of tracheal mucous transport in rats, guinea pigs, rabbits, and dogs
Felicetti, S. A., Wolff, R. K., & Muggenburg, B. A. (1981) · Journal of Applied Physiology · doi:10.1152/jappl.1981.51.6.1612 · Cited by 61 · cited 1×
“Model simulations of TB clearance, presented herein, assumed tracheal mucus velocities of 1.9 mm/min in rats (Felicetti et al., 1981) and 5.5 mm/min in humans (ICRP, 1994).”
BackgroundInfluentialKillingsworth, C. R., Alessandrini, F., Murthy, G. G. K., Catalano, P. J., Paulauskis, J. D., & Godleski, J. J. (1997) · Inhalation Toxicology · doi:10.1080/089583797198060 · Cited by 55
Alveolar distribution of fly ash and of titanium dioxide after long-term inhalation by Wistar rats
Takenaka, S., Dornhöfer-Takenaka, H., & Muhle, H. (1986) · Journal of Aerosol Science · doi:10.1016/0021-8502(86)90105-9 · Cited by 53 · cited 1×
“However, particle disaggregation may be specific to TiO2 aerosols (Takenaka et al., 1986).”
BackgroundMathematical Modeling to Predict the Responses to Poorly Soluble Particles in Rat Lungs
Tran, C. L., Buchanan, D., Miller, B. G., Jones, A. D., & Donaldson, K. (2000) · Inhalation Toxicology · doi:10.1080/08958378.2000.11463252 · Cited by 52 · cited 2×
“, 1994) and particle surface area (Tran et al., 2000), exist.”
BackgroundMethodEmpirical Equations for Nasal Deposition of Inhaled Particles in Small Laboratory Animals and Humans
Zhang, L., & Yu, C. P. (1993) · Aerosol Science and Technology · doi:10.1080/02786829308959620 · Cited by 50 · cited 1×
“The extrathoracic particle deposition efficiencies used in the MPPD model were adopted from the ICRP (1994) for humans and from Zhang and Yu (1993) for rats.”
MethodJarabek, A. M. (1994) · Inhalation Toxicology · doi:10.1080/10917691.1994.12288933 · Cited by 46 · cited 2×
“The analysis presented here is similar to Jarabek et al. (2005), but some terms are defined differently.”
MethodEffects of concentrated ambient particles in rats and hamsters: an exploratory study.
Gordon, T., Nadziejko, C. E., Chen, L., & Schlesinger, R. (2000) · PubMed · Cited by 44
de, W.-S. R., & Cassee, F. R. (2003) · Cited by 40
Alveolar macrophage-stimulated neutrophil and monocyte migration: Effects of in vitro ozone exposure
Driscoll, K. E., & Schlesinger, R. B. (1988) · Toxicology and Applied Pharmacology · doi:10.1016/0041-008x(88)90131-7 · Cited by 39 · cited 6×
“However, it was estimated that a rat lung burden of 250 μg, the mass instilled by Dye et al. (2001), could not be achieved by inhalation at the assumed ambient exposure scenario due to the rapid clearance in the rat (Table 10c). Toxicologically, it is obvious that a different response might be expected between an inst…”
BackgroundMethodInfluentialWHAT PROPERTIES OF PARTICULATE MATTER ARE RESPONSIBLE FOR HEALTH EFFECTS?
Samet, J. M. (2000) · Inhalation Toxicology · doi:10.1080/0895-8378.1987.11463175 · Cited by 30
Interspecies extrapolation based on mechanistic determinants of chemical disposition
Jarabek, A. M. (1995) · Human and Ecological Risk Assessment An International Journal · doi:10.1080/10807039509380054 · Cited by 27 · cited 3×
“Typically, a safety or uncertainty factor of 10 is applied to the estimated acceptable human dose unless a dosimetric adjustment is made, in which case the safety factor is reduced to 3 (U.S. Environmental Protection Agency, 1994; Jarabek, 1995).”
BackgroundMethodInfluentialStöber, W., Morrow, P. E., Koch, W., & Morawietz, G. (1994) · Journal of Aerosol Science · doi:10.1016/0021-8502(94)90060-4 · Cited by 25 · cited 3×
“An important consideration addressed by Stöber et al. (1994) is that not all AM carry the same burden.”
BackgroundMethodPATHOLOGICAL AND IMMUNOLOGICAL EFFECTS OF RESPIRABLE COAL FLY ASH IN MALE WISTAR RATS
Dormans, J. A. M. A. (1999) · Inhalation Toxicology · doi:10.1080/089583799197267 · Cited by 15 · cited 1×
“larger particles, some studies have used a cyclone (Kodavanti et al., 2002; Dormans et al., 1999) or”
BackgroundMorphometric analysis of alveolar responses of F344 rats to subchronic inhalation of nitric oxide.
Mercer, R. R. (1999) · PubMed · Cited by 11
Research works printed but not linked: 4
- Federal Register, 1997, Fed. Reg., 62, 38,652
- Felicetti S. A., 1981, J. Appl. Physiol. Respir. Environ. Exercise Physiol., 51, 1612
- U.S. Environmental Protection Agency, 1994, Methods for derivation of inhalation reference concentrations and application of inhalation dosimetry
- U.S. Environmental Protection Agency, 1996, Air quality criteria for particulate matter, 3
Cited by
Particokinetics In Vitro: Dosimetry Considerations for In Vitro Nanoparticle Toxicity Assessments
Teeguarden, J. G., Hinderliter, P. M., Orr, G., Thrall, B. D., & Pounds, J. G. (2007) · Toxicological Sciences · doi:10.1093/toxsci/kfl165 · Cited by 765
“The use of target tissue dose, rather than less specific measures of dose such as exposure or administered dose, has been shown to improve correlations between dose and response for drugs, chemicals, and inhaled gases and particles (Brown et al., 2005; Schroeter et al., 2006; Treinen-Moslen, 2001; Witschi and Last, 20…”
BackgroundHinderliter, P. M., Minard, K. R., Orr, G., Chrisler, W. B., Thrall, B. D., Pounds, J. G., & Teeguarden, J. G. (2010) · Particle and Fibre Toxicology · doi:10.1186/1743-8977-7-36 · Cited by 496
“The use of target tissue dose, rather than less specific measures of “dose” such as exposure or administered dose, improves correlations between dose and response for drugs, chemicals, and inhaled gases and particles [14-17].”
BackgroundPauluhn, J. (2010) · Toxicological Sciences · doi:10.1093/toxsci/kfp247 · Cited by 358
“1994) and Brown et al. (2005) as well as the deliberations from an ILSI conference”
BackgroundPaur, H.-R., Cassee, F. R., Teeguarden, J., Fissan, H., Diabate, S., Aufderheide, M., Kreyling, W. G., Hänninen, O., Kasper, G., Riediker, M., et al. (2011) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2011.06.005 · Cited by 316
Gangwal, S., Brown, J. S., Wang, A., Houck, K. A., Dix, D. J., Kavlock, R. J., & Hubal, E. A. C. (2011) · Environmental Health Perspectives · doi:10.1289/ehp.1103750 · Cited by 163
“According to Brown et al. (2005), it takes >10 years to reach a steady-state lung burden for insoluble 1 ^m-sized particles for a 0.”
Self-citation
Metadata
- Authors
- Brown, J. S., Wilson, W. E., & Grant, L. D.
- Affiliations
- Environmental Protection Agency (US)
- ORCID
- Brown, James S.
- Venue
- Inhalation Toxicology
- Publisher
- Informa UK Limited
- Published
- 2005-01
- Volume
- 17
- Issue
- 7-8
- Pages
- 355-385
- ISSN
- 0895-8378 (ISSN-L)
- 1091-7691
- OpenAlex
- W2125591939
- Cited by
- 131
- References
- 51
- Citations by year
- 2026: 5 · 2025: 2 · 2024: 15 · 2023: 2 · 2022: 2 · 2021: 3 · 2020: 3 · 2019: 5 · 2018: 7 · 2017: 5 · 2016: 7 · 2015: 8 · 2014: 11 · 2013: 7 · 2012: 8
- FWCI
- 3.96
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Inhalation Toxicology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Air Quality and Health Impacts
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Inhalation and Respiratory Drug Delivery
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Keywords
- particulate matter, particle deposition, particle retention, interspecies extrapolation, alveolar macrophages, alveolar clearance, lung inflammation, aerosol size distribution, exposure duration, dose normalization
- MeSH terms
- Air Pollutants, Animals, Disease Models, Animal, Humans, Lung, Models, Theoretical, Particle Size, Tissue Distribution, Reproducibility of Results, Inhalation Exposure, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.