The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
A four-channel analysis of the tactile sensitivity of the fingertip: frequency selectivity, spatial summation, and temporal summation
Abstract
Thresholds were measured for the detection of vibratory stimuli of variable frequency and duration applied to the index fingertip and thenar eminence through contactors of different sizes. The effects of stimulus frequency could be accounted for by the frequency characteristics of the Pacinian (P), non-Pacinian (NP) I, and NP III channels previously determined for the thenar eminence (Bolanowski et al., J Acoust Soc Am 84: 1680-1694, 1988; Gescheider et al., Somatosens Mot Res 18: 191-201, 2001). The effect of changing stimulus duration was also essentially identical for both sites, demonstrating the same amount of temporal summation in the P channel. Although the effect of changing stimulus frequency and changing stimulus duration did not differ for the two sites, the effect of varying the size of the stimulus was significantly greater for the thenar eminence than for the fingertip. The attenuated amount of spatial summation on the fingertip was interpreted as an indication that the mechanism of spatial summation consists of the operations of both neural integration and probability summation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Four channels mediate the mechanical aspects of touch
Bolanowski, S. J., Gescheider, G. A., Verrillo, R. T., & Checkosky, C. M. (1988) · The Journal of the Acoustical Society of America · doi:10.1121/1.397184 · Cited by 937
Self-citationGescheider, G. A., Bolanowski, S. J., Hall, K. L., Hoffman, K. E., & Verrillo, R. T. (1994) · Somatosensory & Motor Research · doi:10.3109/08990229409028878 · Cited by 174
Self-citation
Cited by
Talking about tactile experiences
Obrist, M., Seah, S. A., & Subramanian, S. (2013) · Proceedings of the SIGCHI Conference on Human Factors in Computing Systems · doi:10.1145/2470654.2466220 · Cited by 1,613
Tactile Displays: Guidance for Their Design and Application
Jones, L. A., & Sarter, N. B. (2008) · Human Factors: The Journal of the Human Factors and Ergonomics Society · doi:10.1518/001872008x250638 · Cited by 561
UltraHaptics: multi-point mid-air haptic feedback for touch surfaces
Carter, T., Seah, S. A., Long, B., Drinkwater, B., & Subramanian, S. (2013) · Proceedings of the 26th annual ACM symposium on User interface software and technology · doi:10.1145/2501988.2502018 · Cited by 512
Haptic Codecs for the Tactile Internet
Steinbach, E., Strese, M., Eid, M., Liu, X., Bhardwaj, A., Liu, Q., Al-Ja'Afreh, M., Mahmoodi, T., Hassen, R., El Saddik, A., et al. (2019) · Proceedings of the IEEE · doi:10.1109/jproc.2018.2867835 · Cited by 166
Effect of Waveform on Tactile Perception by Electrovibration Displayed on Touch Screens
Vardar, Y., Guclu, B., & Basdogan, C. (2017) · IEEE Transactions on Haptics · doi:10.1109/toh.2017.2704603 · Cited by 130
Audio-Tactile Skinny Buttons for Touch User Interfaces
Van Duong, Q., Nguyen, V. P., Luu, A. T., & Choi, S. T. (2019) · Scientific Reports · doi:10.1038/s41598-019-49640-w · Cited by 21
Metadata
- Authors
- Gescheider, G. A., Bolanowski, S. J., Pope, J. V., & Verrillo, R. T.
- Venue
- Somatosensory & Motor Research
- Publisher
- Informa UK Limited
- Published
- 2002-01
- Volume
- 19
- Issue
- 2
- Pages
- 114-124
- ISSN
- 0899-0220 (ISSN-L)
- 1369-1651
- OpenAlex
- W2121070486
- Cited by
- 203
- References
- 2
- FWCI
- 1.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.