Overheating and passive habitability: indoor health and heat indices
The DOI matches its Crossref record; 59 of the 62 references it cites were found in a registry or an index.
Abstract
As extreme heat and weather events are predicted to increase due to global warming, the risk of human heat stress within buildings will increase. To be resilient, buildings will need the capacity to provide habitable indoor conditions without power for limited amounts of time. Additional indoor thermal standards are required for public health to address ‘passive habitability’ during power outages. Current research on building-related heat stress and numerous heat indices is examined in relation to the development of a new heat-safety metric for use in passively conditioned buildings. Most indoor overheating research relies on outdoor temperature data and has no common indoor heat index for evaluating indoor heat stress. A recommendation is made for using the wet-bulb globe temperature (WBGT) and predicted heat strain (PHS) indices for modelling and monitoring of indoor heat stress in healthy adult populations because both indices utilize the primary thermoregulation variables, have associated heat-stress thresholds, and can be assessed or tracked with existing environmental monitoring methods and predictive energy modelling techniques. Further research is recommended on health effects and exposure limits of vulnerable populations, and the variation in thermal factors within buildings and the building stock.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The implications associated with the limited passive habitability of the current built environment have been reported before [53,54].”
From Reduced cognitive function during a heat wave among residents of non-air-conditioned buildings: An observational study of young adults in the summer of 2016 (2018) · cites this paper as [54]
Citations
Cites
Thermal Environmental Conditions for Human Occupancy
Ashrae, S. (1992) · Medical Entomology and Zoology · Cited by 6,092
Heart Disease and Stroke Statistics—2013 Update: A Report From the American Heart Association
Go, A. S., Mozaffarian, D., Roger, V. L., Benjamin, E. J., Berry, J. D., Borden, W. B., Bravata, D. M., Dai, S., Ford, E. S., Fox, C. S., et al. (2013) · Circulation · doi:10.1161/cir.0b013e31828124ad · Cited by 5,292
KLEPEIS, N. E., NELSON, W. C., OTT, W. R., ROBINSON, J. P., TSANG, A. M., SWITZER, P., BEHAR, J. V., HERN, S. C., & ENGELMANN, W. H. (2001) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/sj.jea.7500165 · Cited by 4,803 · cited 2×
“Indoor heat exposures In the US, most children and adults spend over 80% of their time indoors (Klepeis et al., 2001).”
BackgroundPrevalence of obesity in the United States, 2009-2010.
Ogden, C. L., Carroll, M. D., Kit, B. K., & Flegal, K. M. (2012) · PubMed · Cited by 2,467
Death toll exceeded 70,000 in Europe during the summer of 2003
Robine, J.-M., Cheung, S. L. K., Le Roy, S., Van Oyen, H., Griffiths, C., Michel, J.-P., & Herrmann, F. R. (2007) · Comptes Rendus. Biologies · doi:10.1016/j.crvi.2007.12.001 · Cited by 2,127 · cited 2×
“related deaths, while approximately 750 deaths were attributed to the 1995 Chicago heatwave (Klinenberg, 2002; Robine et al., 2008).”
BackgroundInfluentialBoyle, J. P., Thompson, T. J., Gregg, E. W., Barker, L. E., & Williamson, D. F. (2010) · Population Health Metrics · doi:10.1186/1478-7954-8-29 · Cited by 1,309
Heat wave: a social autopsy of disaster in Chicago
(2003) · Choice Reviews Online · doi:10.5860/choice.40-4319 · Cited by 1,273
Tarver, T. (2013) · Journal of Consumer Health On the Internet · doi:10.1080/15398285.2013.756760 · Cited by 1,038
Heat Wave: A Social Autopsy of Disaster in Chicago
Klinenberg, E. (2002) · University of Chicago Press eBooks · doi:10.7208/chicago/9780226026718.001.0001 · Cited by 933
Li, D., & Bou-Zeid, E. (2013) · Journal of Applied Meteorology and Climatology · doi:10.1175/jamc-d-13-02.1 · Cited by 885 · cited 1×
“However, low outdoor air speeds are often associated with heatwaves and thus are likely to reduce the assumed air speed of natural ventilation (Li & Bou-Zeid, 2013).”
BackgroundWet-Bulb Temperature from Relative Humidity and Air Temperature
Stull, R. (2011) · Journal of Applied Meteorology and Climatology · doi:10.1175/jamc-d-11-0143.1 · Cited by 773 · cited 3×
“is used to create the psychrometric wet-bulb temperatures for this paper’s charts (Stull, 2011):”
MethodInfluentialSocial isolation: a predictor of mortality comparable to traditional clinical risk factors
Pantell, M., Rehkopf, D., Jutte, D., Syme, S. L., Balmes, J., & Adler, N. (2013) · American Journal of Public Health · doi:10.2105/ajph.2013.301261 · Cited by 696
Impact of Recent Increase in Incidence on Future Diabetes Burden
Narayan, K. M. V., Boyle, J. P., Geiss, L. S., Saaddine, J. B., & Thompson, T. J. (2006) · Diabetes Care · doi:10.2337/dc06-1136 · Cited by 602
Passive and low energy cooling of buildings
(1995) · Choice Reviews Online · doi:10.5860/choice.32-2759 · Cited by 430 · cited 1×
“This is a similar finding to existing comfort and passive design research, such as that of Baruch Givoni (Givoni, 1994).”
ResultCalculating Workplace WBGT from Meteorological Data: A Tool for Climate Change Assessment
LEMKE, B., & KJELLSTROM, T. (2012) · Industrial Health · doi:10.2486/indhealth.ms1352 · Cited by 394 · cited 5×
“Equation (2) calculates WBGT for indoor spaces with weak radiant sources; this equation eliminates Ta, as Tg has tested to within 0.58C of Ta for indoor Overheating and passive habitability 8 conditions without strong radiant sources (Lemke & Kjellstrom, 2013): WBGTid = 0.7Tnwb + 0.3Tg (2) The WBGT metric is included…”
BackgroundMethodInfluentialClimate change, humidity, and mortality in the United States
Barreca, A. I. (2012) · Journal of Environmental Economics and Management · doi:10.1016/j.jeem.2011.07.004 · Cited by 391 · cited 1×
“Full acclimatization of the body’s perspiration system to increased heat takes over two weeks (Barreca, 2012).”
BackgroundNational Diabetes Fact Sheet, 2011
(2011) · PsycEXTRA Dataset · doi:10.1037/e609522012-001 · Cited by 328
Intensification of hot extremes in the United States
Diffenbaugh, N. S., & Ashfaq, M. (2010) · Geophysical Research Letters · doi:10.1029/2010gl043888 · Cited by 217 · cited 1×
“For example, regional climate change modelling suggests more extreme heatwaves occurring every four to seven years per decade in the western US by the 2030s and in the eastern US by 2059 (Diffenbaugh & Ashdaq, 2010; Gao, Fu, Liu, & Lamarque, 2012).”
BackgroundClimate change and health: Indoor heat exposure in vulnerable populations
White-Newsome, J. L., Sánchez, B. N., Jolliet, O., Zhang, Z., Parker, E. A., Timothy Dvonch, J., & O'Neill, M. S. (2012) · Environmental Research · doi:10.1016/j.envres.2011.10.008 · Cited by 215
On the thermal performance of low income housing during heat waves
Sakka, A., Santamouris, M., Livada, I., Nicol, F., & Wilson, M. (2012) · Energy and Buildings · doi:10.1016/j.enbuild.2012.01.023 · Cited by 214
Lower sedentary metabolic rate in women compared with men.
Ferraro, R., Lillioja, S., Fontvieille, A. M., Rising, R., Bogardus, C., & Ravussin, E. (1992) · Journal of Clinical Investigation · doi:10.1172/jci115951 · Cited by 213
The Great 2006 Heat Wave over California and Nevada: Signal of an Increasing Trend
Gershunov, A., Cayan, D. R., & Iacobellis, S. F. (2009) · Journal of Climate · doi:10.1175/2009jcli2465.1 · Cited by 204
Minimization of heatwave morbidity and mortality
Kravchenko, J., Abernethy, A. P., Fawzy, M., & Lyerly, H. K. (2013) · American Journal of Preventive Medicine · doi:10.1016/j.amepre.2012.11.015 · Cited by 195
Gao, Y., Fu, J. S., Drake, J. B., Liu, Y., & Lamarque, J.-F. (2012) · Environmental Research Letters · doi:10.1088/1748-9326/7/4/044025 · Cited by 184
Task performance in heat: a review
RAMSEY, J. D. (1995) · Ergonomics · doi:10.1080/00140139508925092 · Cited by 180 · cited 1×
“When the core temperature reaches 388C, the capacity for physical work diminishes, mental activity is impaired and accident risk increases (Ramsey, 1995; Ramsey & Chai, 1983).”
BackgroundThe effect of weather on grid systems and the reliability of electricity supply
Ward, D. M. (2013) · Climatic Change · doi:10.1007/s10584-013-0916-z · Cited by 175 · cited 2×
“Weather events have caused nearly three-quarters of the larger outages in North America and half of the larger outages in England and Wales (Ward, 2013).”
BackgroundClimate change, heat waves, and mortality projections for Chicago
Hayhoe, K., Sheridan, S., Kalkstein, L., & Greene, S. (2010) · Journal of Great Lakes Research · doi:10.1016/j.jglr.2009.12.009 · Cited by 164
Heat stroke: implications for critical care and anaesthesia
Grogan, H., & Hopkins, P. M. (2002) · British Journal of Anaesthesia · doi:10.1093/bja/88.5.700 · Cited by 156 · cited 1×
“Severe heat stress can adversely impact on basic body functions such as respiration, circulation, mobility, immune response, kidney function and cognition (Grogan, 2002).”
BackgroundSummertime temperatures and thermal comfort in UK homes
Lomas, K. J., & Kane, T. (2013) · Building Research & Information · doi:10.1080/09613218.2013.757886 · Cited by 150 · cited 1×
“…compare heat vulnerability in relation to building type (i.e. different types of residential structures); a 2013 study by Lomas and Kanes (2013) found that detached homes with solid walls fared better than flats with shared walls under free-running conditions during a heatwave (Lomas & Kane, 2013).”
BackgroundKnowlton, K., Rotkin-Ellman, M., Geballe, L., Max, W., & Solomon, G. M. (2011) · Health Affairs · doi:10.1377/hlthaff.2011.0229 · Cited by 139
Air temperature thresholds for indoor comfort and perceived air quality
Zhang, H., Arens, E., & Pasut, W. (2011) · Building Research & Information · doi:10.1080/09613218.2011.552703 · Cited by 137
Loughnan, M., TAPPER, N. J., Lynch, K. R., McInnes, J. A., & Phan, T. (2012) · Cited by 100
Effects of Heat Wave on Body Temperature and Blood Pressure in the Poor and Elderly
Kim, Y.-M., Kim, S., Cheong, H.-K., Ahn, B., & Choi, K. (2012) · Environmental Health and Toxicology · doi:10.5620/eht.2012.27.e2012013 · Cited by 98 · cited 2×
“Indoor heat exposures of the general population can reach harmful levels during and outside of heatwaves (Anderson et al., 2013; AECOM, 2012; Barnett et al., 2013; Kim et al., 2012).”
BackgroundA Survey of Wind Speeds in Indoor Workplaces
(1998) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/42.5.303 · Cited by 98 · cited 1×
“Wind speeds in mechanically ventilated workplaces are typically below 0.3 m/s (Baldwin & Maynard, 1998), whereas naturally ventilated buildings typically show air speeds above 0.2 m/s (Zhang, Arens, & Pasut, 2011).”
BackgroundInfluentialOccupational Heat Stress Assessment by the Predicted Heat Strain Model
MALCHAIRE, J. B. M. (2006) · Industrial Health · doi:10.2486/indhealth.44.380 · Cited by 96 · cited 2×
“…developed in the late 1990s, is the evolution of the sweat rate metric and for a given space or location, this analytical method calculates body heat balance in relation to environmental variables and an individual’s required sweat rate for maintaining core body temperatures (Malchaire, 2006).”
BackgroundMethodFuture heat vulnerability in California, Part II: projecting future heat-related mortality
Sheridan, S. C., Allen, M. J., Lee, C. C., & Kalkstein, L. S. (2012) · Climatic Change · doi:10.1007/s10584-012-0437-1 · Cited by 94
Defining indoor heat thresholds for health in the UK
Anderson, M., Carmichael, C., Murray, V., Dengel, A., & Swainson, M. (2013) · Perspectives in Public Health · doi:10.1177/1757913912453411 · Cited by 93 · cited 2×
“Indoor heat exposures of the general population can reach harmful levels during and outside of heatwaves (Anderson et al., 2013; AECOM, 2012; Barnett et al., 2013; Kim et al., 2012).”
BackgroundEvaluation of cooling effects: outdoor water mist fan
Farnham, C., Emura, K., & Mizuno, T. (2015) · Building Research & Information · doi:10.1080/09613218.2015.1004844 · Cited by 92
Urban social housing resilience to excess summer heat
Mavrogianni, A., Taylor, J., Davies, M., Thoua, C., & Kolm-Murray, J. (2015) · Building Research & Information · doi:10.1080/09613218.2015.991515 · Cited by 88 · cited 1×
“Changes in climate and population demographics are expected globally to increase the risks of overheating in buildings and the vulnerability of occupants to heat stress during both routine operation and extreme heat events (IPCC, 2014; Mavrogianni et al., 2015).”
BackgroundSeventy-five years of searching for a heat index
Lee, D. H. K. (1980) · Environmental Research · doi:10.1016/0013-9351(80)90146-2 · Cited by 85 · cited 1×
“With that said, various heat index research papers suggest that for setting general precautionary and ‘not to be exceeded’ heat exposure limits, WBGT is adequate (Auliciems & Szokoly, 2007; Holmer, 2010; Lee, 1980).”
BackgroundIndoor thermal condition in urban heat Island – Development of a predictive tool
Mirzaei, P. A., Haghighat, F., Ashtiani, A. N., Yagouti, A., Giguère, M., Keusseyan, R., & Coman, A. (2012) · Building and Environment · doi:10.1016/j.buildenv.2012.03.018 · Cited by 82 · cited 1×
“A similar tool has been developed to predict indoor dry-bulb air temperatures in urban building based on 10 factors including built surroundings, usage patterns etc. (Mirzaei et al., 2012).”
MethodUpdate on diabetes in the elderly and in nursing home residents
Migdal, A., Yarandi, S. S., Smiley, D., & Umpierrez, G. E. (2011) · Journal of the American Medical Directors Association · doi:10.1016/j.jamda.2011.02.010 · Cited by 81
Reappraisal of the resting metabolic rate of normal young men
Clark, H., & Hoffer, L. J. (1991) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/53.1.21 · Cited by 74 · cited 1×
“…rate (BMR) varies between individuals based on age, weight, physical fitness, etc.; average healthy males have an RMR around 1650 kCal/day (Clark & Hoffer, 1991), a similar study found average males to have a BMR of 1785 kCal/day (+352), while healthy females had an average BMR of 1534…”
BackgroundPrediction of the indoor temperatures of an urban area with an in-time regression mapping approach
Smargiassi, A., Fournier, M., Griot, C., Baudouin, Y., & Kosatsky, T. (2008) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/sj.jes.7500588 · Cited by 72
Climate change and occupational heat stress: methods for assessment
Holmér, I. (2010) · Global Health Action · doi:10.3402/gha.v3i0.5719 · Cited by 60 · cited 2×
“In comparing WBGT with PHS, Holmer recommends that WBGT be used ‘for a first and rough estimation’ of heat stress, whereas PHS should be used for more quantitative evaluation of heat stress in relation to workers, productivity and economy (Holmer, 2010).”
Interaction between climate and animal production
(2003) · Wageningen Academic Publishers eBooks · doi:10.3920/978-90-8686-517-8 · Cited by 45
Revel, G. M., Arnesano, M., & Pietroni, F. (2014) · Measurement Science and Technology · doi:10.1088/0957-0233/25/8/085101 · Cited by 40
Stéphan, F., Ghiglione, S., Decailliot, F., Yakhou, L., Duvaldestin, P., & Legrand, P. (2004) · British Journal of Anaesthesia · doi:10.1093/bja/aeh291 · Cited by 40 · cited 3×
“To illustrate the use of a heat-safety metric, indoor heat health data from the previously mentioned 2003 Paris hospital (Stephan et al., 2005) are evaluated in relation to the WBGT thresholds.”
BackgroundMethodInfluentialUSDOE Office of Science (SC), Eto, J. H., LaCommare, K. H., Larsen, P., Todd, A., & Fisher, E. B. (2012) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · doi:10.2172/1055706 · Cited by 36
On the Transition Thermal Discomfort to Heat Stress as a Function of the PMV Value
Alfano, F. R. D., Palella, B. I., & Riccio, G. (2013) · Industrial Health · doi:10.2486/indhealth.2012-0163 · Cited by 31
OPERATIVE TEMPERATURE AND GLOBE TEMPERATURE
Kazkaz, M., & Pavelek, M. (2013) · Cited by 28
Environmental Health and Toxicology
Fan, V., Nakano, P., Colbert, S., & Kopp, M. (2021) · Springer Publishing Company eBooks · doi:10.1891/9780826140951.0041 · Cited by 23
Evaluation of the Predictive Accuracy of Five Whole Building Baseline Models
Lawrence Berkeley National Lab. (LBNL), B., Granderson, J., USDOE Office of Science (SC), & Price, P. N. (2012) · doi:10.2172/1172955 · Cited by 21 · cited 1×
“If modelling methods are too generalized, the reliability of energy models is diminished; however, models of existing buildings have achieved accuracy within 3–5% when properly calibrated (Granderson & Price, 2012; Samuelson, 2013).”
MethodInherent variability in heat-stress decision rules
RAMSEY, J. D., & CHAI, C. P. (1983) · Ergonomics · doi:10.1080/00140138308963365 · Cited by 17 · cited 1×
“When the core temperature reaches 388C, the capacity for physical work diminishes, mental activity is impaired and accident risk increases (Ramsey, 1995; Ramsey & Chai, 1983).”
BackgroundThe natural ventilation performance of buildings under alternative future weather projections
Barclay, M., Sharples, S., Kang, J., & Watkins, R. (2011) · Building Services Engineering Research and Technology · doi:10.1177/0143624411427460 · Cited by 17
Pathways to climate adapted and healthy low income housing
Barnett, G., Beaty, M., & Chen, D. (2013) · Cited by 15
Cox, S. (2010) · The New Press eBooks · doi:10.2307/jj.25291693 · Cited by 12 · cited 1×
“Despite the fact that passive cooling is currently possible, there is a growing dependence on mechanical airconditioning (Cox, 2010).”
BackgroundCox, S. (2010) · Cited by 3
Research works printed but not linked: 39
- ACGIH, 2013, 2013 TLVs and BEIs: Based on the documentation of threshold limit values for chemical substances and physical agents & biological exposure indicies
- Administration on Aging, 2013, Projections of future growth of the older population
- AECOM, 2012, Investigation into overheating in homes: Literature review
- ASHRAE, 2013, ASHRAE handbook: Fundamentals
- Auliciems A., 2007, Thermal comfort: Design tools and techniques
- Barclay M., 2012, Building Service Engineering, 35, 22
- Bradshaw V., 2006, The building environment: Active and passive control systems
- BSI, 2007, BS EN 15251:2007 Indoor environmental input parameters for design and assessment of energy performance of buildings addressing indoor air quality, thermal environment, lighting and acoustics
- Building Resiliency Task Force, 2013, Report to mayor Michael R. Bloomberg & speaker Christine Quinn
- CDC, 1996, Heat-wave-related mortality – Milwaukee, Wisconsin, July 1995
- CDC, 2013, Adult obesity facts
- CIBSE, 2013, TM 52:2013 – The limits of thermal comfort: Avoiding overheating in European buildings
- CIBSE, 2014, TM 49:2014 design summer years for London
- Collins, M. & Knutti, R. (2013). Chapter 12: Long-term Climate Change: Projections, Commitments and Irreversibility – Final Draft, Underlying Scientific–Technical Assessment. InWorking Group 1 contribution to the IPCC fifth assessment report:Climate Change 2013: The physical science basis. Geneva, SUI: IPCC.
- Dengel A., 2012, Overheating in new homes: A review of the evidence
- Energy Information Administration, 2011, Residential energy consumption survey (RECS) – Analysis & projections; air cond. Nearly 100 Million US homes
- Federal Interagency Forum on Aging-Related Statistics, 2012, Older Americans 2012: Key indicators of well-being
- Gabe T., 2013, Poverty in the United States: 2012; Report # RL33069
- Geiss L. S., 2012, Morbidity and Mortality Weekly Report (MMWR), 61, 918
- Go A. S., 2012, A Report From the American Heart Association, 127, e6
- Health Canada, 2013, Health facilities preparation for extreme heat: Recommendations for retirement and care facility managers
- IPCC, 2014, Climate change 2014: Impacts, adaptation, and vulnerability IPCC working group II contribution to AR5
- ISO, 1989, ISO 7243:1989: Hot environments – Estimation of the heat stress on working man, based on the WBGT-index (wet bulb globe temperature)
- ISO, 2004, ISO 7993:2004 Ergonomics of the thermal environment – Analytical determination and interpretation of heat stress using calculation of the predicted heat strain
- Kosacz N., 2012, Morbidity and Mortality Weekly Report (MMWR), 61, 938
- London School of Hygiene and Tropical Medicine, 2014, AWESOME (Air pollution and weather-related health impacts: methodological study): Work Packages
- Luscuere P., 2002, Air-conditioning in nursing homes: till death do us part?
- Mills E., 2012, Electric grid disruptions and extreme weather
- Minnesota Department of Labor and Industry, 2012, Heat stress guide
- Navy Environmental Health Center, 2007, Prevention and treatment of heat and cold stress injuries
- NIOSH, 1986, Occupation exposure to hot environments
- NIOSH, 2013, Criteria for a recommended standard: Occupational exposure to heat and hot environments
- OSHA, 1999, OSHA technical manual, section III
- PHE, 2014, Heatwave plan for England 2014: Protecting health and reducing harm from severe heat and heatwaves
- PlaNYC, 2013, New York city special initiative for rebuilding and resiliency: A stronger, more resilient New York
- Samuelson H. W., 2014, Toward buildings that work: Reusing design-phase energy models for operations-phase improvements
- SFDPH, 2013, Overheating buildings in coastal communities: Homes, health impacts, and Opportunities for collaboration in San Francisco
- University of Illinois and LBNL, 2012, Input output reference: The encyclopedic reference to EnergyPlus input and output
- Williams D., 2006, Sustainable design: Ecology, architecture, & planning
Cited by
Thermal inertia in buildings: A review of impacts across climate and building use
Verbeke, S., & Audenaert, A. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.08.083 · Cited by 415
A review of current and future weather data for building simulation
Herrera, M., Natarajan, S., Coley, D. A., Kershaw, T., Ramallo-González, A. P., Eames, M., Fosas, D., & Wood, M. (2017) · Building Services Engineering Research and Technology · doi:10.1177/0143624417705937 · Cited by 227
Attia, S., Levinson, R., Ndongo, E., Holzer, P., Berk Kazanci, O., Homaei, S., Zhang, C., Olesen, B. W., Qi, D., Hamdy, M., et al. (2021) · Energy and Buildings · doi:10.1016/j.enbuild.2021.110869 · Cited by 208
“approaching heat waves and suggest adaptation strategies following building operators and occupants [62].”
BackgroundCedeño Laurent, J. G., Williams, A., Oulhote, Y., Zanobetti, A., Allen, J. G., & Spengler, J. D. (2018) · PLoS Medicine · doi:10.1371/journal.pmed.1002605 · Cited by 205
Ten questions concerning energy flexibility in buildings
Li, R., Satchwell, A. J., Finn, D., Christensen, T. H., Kummert, M., Le Dréau, J., Lopes, R. A., Madsen, H., Salom, J., Henze, G., et al. (2022) · Building and Environment · doi:10.1016/j.buildenv.2022.109461 · Cited by 167
“Flexible buildings are naturally more resilient by providing habitable indoor conditions for longer periods of time under adverse or emergency events [75].”
Background
Metadata
- Authors
- Holmes, S. H., Phillips, T., & Wilson, A.
- Affiliations
- University of Hartford (US)
- Corresponding author
- Holmes, Seth H.
- ORCID
- Holmes, Seth H.
- Venue
- Building Research & Information
- Publisher
- Informa UK Limited
- Published
- 2015-04-29
- Volume
- 44
- Issue
- 1
- Pages
- 1-19
- ISSN
- 0961-3218 (ISSN-L)
- 1466-4321
- OpenAlex
- W2120919285
- Cited by
- 91
- References
- 62
- Citations by year
- 2026: 5 · 2025: 6 · 2024: 9 · 2023: 8 · 2022: 11 · 2021: 14 · 2020: 14 · 2019: 9 · 2018: 9 · 2017: 3 · 2016: 3
- FWCI
- 6.79
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Building Research & Information (publishedVersion)
- Topics
- Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
- Health Sciences › Medicine › Physiology (medical) › Thermoregulation and physiological responses
- Physical Sciences › Environmental Science › Environmental Engineering › Urban Heat Island Mitigation
- Keywords
- indoor overheating, heat stress, heat index, wet bulb globe temperature, power outages, indoor thermal comfort, vulnerable populations
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.