New Trends in Sample Preparation Techniques for Environmental Analysis
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
Environmental samples include a wide variety of complex matrices, with low concentrations of analytes and presence of several interferences. Sample preparation is a critical step and the main source of uncertainties in the analysis of environmental samples, and it is usually laborious, high cost, time consuming, and polluting. In this context, there is increasing interest in developing faster, cost-effective, and environmentally friendly sample preparation techniques. Recently, new methods have been developed and optimized in order to miniaturize extraction steps, to reduce solvent consumption or become solventless, and to automate systems. This review attempts to present an overview of the fundamentals, procedure, and application of the most recently developed sample preparation techniques for the extraction, cleanup, and concentration of organic pollutants from environmental samples. These techniques include: solid phase microextraction, on-line solid phase extraction, microextraction by packed sorbent, dispersive liquid-liquid microextraction, and QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Anastassiades, M., Lehotay, S. J., Štajnbaher, D., & Schenck, F. J. (2003) · Journal of AOAC INTERNATIONAL · doi:10.1093/jaoac/86.2.412 · Cited by 5,670 · cited 3×
“The QuEChERS procedure, an acronym of quick, easy, cheap, effective, rugged, and safe, was developed by Anastassiades and coworkers in 2003 as a new approach to extract pesticides from fruits and vegetables (Anastassiades et al., 2003).”
MethodDetermination of organic compounds in water using dispersive liquid–liquid microextraction
Rezaee, M., Assadi, Y., Milani Hosseini, M.-R., Aghaee, E., Ahmadi, F., & Berijani, S. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.03.007 · Cited by 3,402 · cited 15×
“(2006), is a simple, fast, cheap, and eco-friendly extraction technique based on a ternary solvent system (Rezaee et al., 2006).”
BackgroundMethodInfluentialSolvent Microextraction into a Single Drop
Jeannot, M. A., & Cantwell, F. F. (1996) · Analytical Chemistry · doi:10.1021/ac960042z · Cited by 1,282 · cited 1×
“To this purpose, liquid-phase microextraction (LPME), introduced by Cantwell and coworkers (Jeannot and Cantwell, 1996), was developed by reducing the volume of solvent to just a few μL.”
MethodEvolution of dispersive liquid–liquid microextraction method
Rezaee, M., Yamini, Y., & Faraji, M. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.11.088 · Cited by 971 · cited 21×
“DLLME can also be performed with no use of dispersant solvent to simplify the experimental process, using an adequate extractant and an agitation step to promote the formation of the cloudy solution (Salgueiro-González et al., 2012).”
MethodInfluentialBerijani, S., Assadi, Y., Anbia, M., Milani Hosseini, M.-R., & Aghaee, E. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.05.010 · Cited by 870 · cited 2×
“, 2012), and to a greater extent, pesticides (Alves et al., 2011, 2012; Berijani et al., 2006; Caldas et al., 2010; Carro et al., 2012; Farajzadeh et al., 2009; Fu et al., 2009a, 2009b; Tsai and Huang, 2009a, 2009b; Zhou et al., 2009).”
BackgroundLeong, M.-I., & Huang, S.-D. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.09.111 · Cited by 413 · cited 9×
“In 2006 a MEPS method was developed for the first time for aqueous samples, for the extraction of PAHs in water (ElBeqqali et al., 2006).”
MethodInfluentialRezaee, M., Yamini, Y., Shariati, S., Esrafili, A., & Shamsipur, M. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.12.091 · Cited by 336 · cited 2×
“, 2010), endocrine disrupters (Du et al., 2010; Luo et al., 2010; Rezaee et al., 2009), and pharmaceuticals (Herrera-Herrera et al.”
BackgroundTemperature-controlled ionic liquid dispersive liquid phase micro-extraction
Zhou, Q., Bai, H., Xie, G., & Xiao, J. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.10.103 · Cited by 303 · cited 2×
“They have low vapor pressure, great thermal stability, and miscibility with both water and organic solvents (Bai et al., 2009; He et al., 2009; Zhou et al., 2008b).”
BackgroundLiang, P., Xu, J., & Li, Q. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.12.025 · Cited by 276
Kocúrová, L., Balogh, I. S., Šandrejová, J., & Andruch, V. (2012) · Microchemical Journal · doi:10.1016/j.microc.2011.12.002 · Cited by 271 · cited 23×
“DLLME can also be performed with no use of dispersant solvent to simplify the experimental process, using an adequate extractant and an agitation step to promote the formation of the cloudy solution (Salgueiro-González et al., 2012).”
MethodInfluential
Cited by
Evolution and applications of the QuEChERS method
González-Curbelo, M. Á., Socas-Rodríguez, B., Herrera-Herrera, A. V., González-Sálamo, J., Hernández-Borges, J., & Rodríguez-Delgado, M. Á. (2015) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.04.012 · Cited by 404
A comprehensive look at solid-phase microextraction technique: A review of reviews
Jalili, V., Barkhordari, A., & Ghiasvand, A. (2020) · Microchemical Journal · doi:10.1016/j.microc.2019.104319 · Cited by 317
Bruzzoniti, M. C., Checchini, L., De Carlo, R. M., Orlandini, S., Rivoira, L., & Del Bubba, M. (2014) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-014-7798-4 · Cited by 301
Merkle, S., Kleeberg, K., & Fritsche, J. (2015) · Chromatography · doi:10.3390/chromatography2030293 · Cited by 250
“A number of reviews on SPME have already been published, dealing with food analysis [12–15], environmental analysis [16–21], calibration methods [22], SPME coatings [11,23–26], drug analysis [12,27], the analysis of specific compounds [28,29] and specific SPME techniques [30].”
BackgroundDispersive Solid‐Phase Extraction
Socas‐Rodríguez, B., Herrera‐Herrera, A. V., Asensio‐Ramos, M., & Hernández‐Borges, J. (2015) · Analytical Separation Science · doi:10.1002/9783527678129.assep056 · Cited by 250
Câmara, J. S., Perestrelo, R., Berenguer, C. V., Andrade, C. F. P., Gomes, T. M., Olayanju, B., Kabir, A., M. R. Rocha, C., Teixeira, J. A., & Pereira, J. A. M. (2022) · Molecules · doi:10.3390/molecules27092953 · Cited by 199
“It can be used to highly enrich analytes in a relatively short time and uses simple laboratory equipment, which considerably lowers the cost of analysis [4,10].”
BackgroundKabir, A., Locatelli, M., & Ulusoy, H. (2017) · Separations · doi:10.3390/separations4040036 · Cited by 169
“Additionally, other commercial sorbents, such as new kinds of graphitic sorbent, polypyrrole/ polyamide, polyaniline nanowires, CMK-3 nanoporous materials, functionalized silica monoliths, APS (amino-propyl silane), and cyanopropyl hybrid silica have been successfully applied in MEPS devices to extract different group…”
MethodKnoll, S., Rösch, T., & Huhn, C. (2020) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-020-02811-5 · Cited by 91
The use of magnetic nanoparticles in sample preparation devices and tools
Keçili, R., Büyüktiryaki, S., Dolak, İ., & Hussain, C. M. (2020) · Handbook of Nanomaterials in Analytical Chemistry · doi:10.1016/b978-0-12-816699-4.00005-0 · Cited by 64
Greening Sample Preparation: New Solvents, New Sorbents
Ramos, L. (2020) · Challenges in Green Analytical Chemistry · doi:10.1039/9781788016148-00114 · Cited by 6
Metadata
- Authors
- Ribeiro, C., Ribeiro, A. R., Maia, A. S., Gonçalves, V. M. F., & Tiritan, M. E.
- Venue
- Critical Reviews in Analytical Chemistry
- Publisher
- Informa UK Limited
- Published
- 2014-01-01
- Volume
- 44
- Issue
- 2
- Pages
- 142-185
- ISSN
- 1040-8347 (ISSN-L)
- 1547-6510
- OpenAlex
- W2016485348
- Cited by
- 104
- References
- 21
- FWCI
- 11.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.