The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Recent Developments and Applications of Solid Phase Microextraction (SPME) in Food and Environmental Analysis—A Review
Open accessAbstract
Solid-phase microextraction (SPME) is a simple, sensitive, rapid and solvent-free technique for the extraction of analytes from gaseous, liquid and solid samples and takes a leading position among microextraction methods. Application of SPME in sample preparation has been increasing continuously over the last decade. It is most often used as an automatized fiber injection system coupled to chromatographic separation modules for the extraction of volatile and semivolatile organic compounds and also allows for the trace analysis of compounds in complex matrices. Since SPME was first introduced in the early 1990s, several modifications have been made to adapt the procedure to specific application requirements. More robust fiber assemblies and coatings with higher extraction efficiencies, selectivity and stability have been commercialized. Automation and on-line coupling to analytical instruments have been achieved in many applications and new derivatization strategies as well as improved calibration procedures have been developed to overcome existing limitations regarding quantitation. Furthermore, devices using tubes, needles or tips for extraction instead of a fiber have been designed. In the field of food analysis, SPME has been most often applied to fruit/vegetables, fats/oils, wine, meat products, dairy and beverages whereas environmental applications focus on the analysis of air, water, soil and sediment samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gałuszka, A., Migaszewski, Z., & Namieśnik, J. (2013) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2013.04.010 · Cited by 2,461
Prosen, H., & Zupančič-Kralj, L. (1999) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(98)00109-5 · Cited by 565
Research works printed but not linked: 377
- 2007, Focus on sample handling, Anal. Bioanal. Chem., 388, 1001, 10.1007/s00216-007-1340-x · DOI
- Salafranca, 2009, Critical review on recent developments in solventless techniques for extraction of analytes, Anal. Bioanal. Chem., 393, 809, 10.1007/s00216-008-2437-6 · DOI · Paper page
- Mondello, 2005, Reliable characterization of coffee bean aroma profiles by automated headspace solid phase microextraction-gas chromatography-mass spectrometry with the support of a dual-filter mass spectra library, J. Sep. Sci., 28, 1101, 10.1002/jssc.200500026 · DOI
- Arthur, 1990, Solid Phase Microextraction with Thermal Desorption Using Fused Silica Optical Fibers, Anal. Chem., 62, 2145, 10.1021/ac00218a019 · DOI · Paper page
- Pawliszyn, J. (1997). Solid Phase Microextraction: Theory and Practice, Wiley, VCH. · DOI · Paper page
- Lord, 2000, Evolution of solid-phase microextraction technology, J. Chromatogr. A, 885, 153, 10.1016/S0021-9673(00)00535-5 · DOI · Paper page
- Adahchour, 2002, Application of Solid-Phase Micro-Extraction and Comprehensive Two-Dimensional Gas Chromatography (GC x GC) for Flavour Analysis, Chromatographia, 55, 361, 10.1007/BF02491673 · doi:10.1007/bf02491673
- Chai, 1995, Analysis of Environmental Air Samples by Solid-Phase Microextraction and Gas Chromatography/lon Trap Mass Spectrometry, Environ. Sci. Technol., 29, 693, 10.1021/es00003a017 · DOI · Paper page
- Nollet, L.M.L., and Toldrá, F. (2007). Advances in Food Diagnostics, Blackwell Publishing. [1st ed.]. · doi:10.1002/9780470277805
- Pawliszyn, J. (1997). Method and Device for Solid Phase Microextraction and Desorption. US Patent. · DOI · Paper page
- Dietz, 2006, Recent developments in solid-phase microextraction coatings and related techniques, J. Chromatogr. A, 1103, 183, 10.1016/j.chroma.2005.11.041 · DOI · Paper page
- Kataoka, 2000, Applications of solid-phase microextraction in food analysis, J. Chromatogr. A, 880, 35, 10.1016/S0021-9673(00)00309-5 · DOI · Paper page
- Majcher, 2012, Microextraction techniques in the analysis of food flavor compounds: A review, Anal. Chim. Acta, 738, 13, 10.1016/j.aca.2012.06.006 · DOI · Paper page
- Pillonel, 2002, Rapid Preconcentration and Enrichment Techniques for the Analysis of Food Volatile. A Review, Lebensm.-Wiss. Technol., 35, 1, 10.1006/fstl.2001.0804 · DOI
- Wardencki, 2004, A review of theoretical and practical aspects of solid-phase microextraction in food analysis, Int. J. Food Sci. Technol., 39, 703, 10.1111/j.1365-2621.2004.00839.x · DOI · Paper page
- Alpendurada, 2000, Solid-phase microextraction: A promising technique for sample preparation in environmental analysis, J. Chromatogr. A, 889, 3, 10.1016/S0021-9673(00)00453-2 · DOI · Paper page
- Buchberger, 2007, Sorptive Extraction Techniques for Trace Analysis of Organic Pollutants in the Aquatic Environment, Acta Chim. Slov., 54, 1
- Ouyang, 2006, Recent developments in SPME for on-site analysis and monitoring, TrAC Trends Anal. Chem., 25, 692, 10.1016/j.trac.2006.05.005 · DOI · Paper page
- Ribeiro, 2014, New Trends in Sample Preparation Techniques for Environmental Analysis, Crit. Rev. Anal. Chem., 44, 142, 10.1080/10408347.2013.833850 · DOI
- Wardencki, 2007, Trends in solventless sample preparation techniques for environmental analysis, J. Biochem. Biophys. Methods, 70, 275, 10.1016/j.jbbm.2006.07.004 · DOI
- 2014, Microextraction Techniques Coupled to Liquid Chromatography with Mass Spectrometry for the Determination of Organic Micropollutants in Environmental Water Samples, Molecules, 19, 10320, 10.3390/molecules190710320 · DOI
- Ouyang, 2008, A critical review in calibration methods for solid-phase microextraction, Anal. Chim. Acta, 627, 184, 10.1016/j.aca.2008.08.015 · DOI
- Mehdinia, 2013, Electrochemically prepared solid-phase microextraction coatings—A review, Anal. Chim. Acta, 781, 1, 10.1016/j.aca.2013.03.012 · DOI
- Mehdinia, 2014, A review on procedures for the preparation of coatings for solid phase microextraction, Microchim. Acta, 181, 1169, 10.1007/s00604-014-1265-y · DOI · Paper page
- Kumar, 2008, A review on development of solid phase Microextraction fibers by sol–gel methods and their applications, Anal. Chim. Acta, 610, 1, 10.1016/j.aca.2008.01.028 · DOI · Paper page
- Luo, 2015, Review: Recent developments of carbon nanotubes hybrid assemblies for sensing, Am. J. Nano Res. Appl., 3, 23
- Moein, M.M., Said, R., Bassyouni, F., and Abdel-Rehim, M. (2014). Solid Phase Microextraction and Related Techniques for Drugs in Biological Samples. J. Anal. Methods Chem. · DOI
- Aulakh, 2005, A Review on Solid Phase Micro Extraction—High Performance Liquid Chromatography (SPME-HPLC) Analysis of Pesticides, Crit. Rev. Anal. Chem., 35, 71, 10.1080/10408340590947952 · DOI · Paper page
- Turner, 2009, Analytical methods for determination of mycotoxins: A review, Anal. Chim. Acta, 632, 168, 10.1016/j.aca.2008.11.010 · DOI · Paper page
- Kataoka, 2002, Automated sample preparation using in-tube solid-phase microextraction and its application—A review, Anal. Bioanal. Chem., 373, 31, 10.1007/s00216-002-1269-z · DOI · Paper page
- Smith, 2003, Before the injection—Modern methods of sample preparation for separation techniques, J. Chromatogr. A, 1000, 3, 10.1016/S0021-9673(03)00511-9 · DOI · Paper page
- Philo, 2002, Determination of bisphenol-type contaminants from food packaging materials in aqueous foods by solid-phase microextraction–high-performance liquid chromatography, J. Chromatogr. A, 963, 375, 10.1016/S0021-9673(02)00554-X · DOI
- Zhang, 1993, Headspace solid-phase microextraction, Anal. Chem., 65, 1843, 10.1021/ac00062a008 · DOI · Paper page
- Tuduri, 2003, A simple calibration procedure for volatile organic compounds sampling in air with adsorptive solid-phase microextraction fibers, Analyst, 128, 1028, 10.1039/b300968h · doi:10.1039/b300968h
- Spietelun, 2010, Current trends in solid-phase microextraction (SPME) fibre coatings, Chem. Soc. Rev., 39, 4524, 10.1039/c003335a · DOI
- Zygmunt, 2000, Application of solid-phase microextraction for determination of organic vapours in gaseous matrices, J. Chromatogr. A, 885, 405, 10.1016/S0021-9673(99)01157-7 · DOI
- Pawliszyn, 2015, Direct Immersion Solid-Phase Microextraction with Matrix-Compatible Fiber Coating for Multiresidue Pesticide Analysis of Grapes by Gas Chromatography-Time-of-Flight Mass Spectrometry (DI-SPME-GC-ToFMS), J. Agric. Food Chem., 63, 4464, 10.1021/jf506212j · DOI
- Aulakh, 2005, A Review on Solid Phase Micro Extraction—High Performance Liquid Chromatography (SPME-HPLC) Analysis of Pesticides, Crit. Rev. Anal. Chem., 35, 71, 10.1080/10408340590947952 · DOI · Paper page
- Spietelun, A., Marcinkowski, Ł., Kloskowski, A., and Namieśnik, J. (2012, January 16–18). Application of green sample preparation techniques for the isolation, preconcentration and gas chromatographic determination of organic environmental pollutants. Proceeedings of the 6th Shanghai International Symposium on Analytical Chemistry, Shanghai, China.
- Tadeo, 2008, Determination of Pesticides in Water, Analysis of Pesticides in Food and Enviromental Samples, Volume 3, 231
- Vas, 2004, Solid-phase microextraction: A powerful sample preparation tool prior to mass spectrometric analysis, J. Mass Spectrom., 39, 233, 10.1002/jms.606 · DOI · Paper page
- Ai, 1997, Solid Phase Microextraction for Quantitative Analysis in Nonequilibrium Situations, Anal. Chem., 69, 1230, 10.1021/ac9609541 · DOI · Paper page
- Ai, 1997, Headspace Solid Phase Microextraction. Dynamics and Quantitative Analysis before Reaching a Partition Equilibrium, Anal. Chem., 69, 3260, 10.1021/ac970024x · doi:10.1021/ac970024x
- Eisert, 1997, Automated In-Tube Solid-Phase Microextraction Coupled to High-Performance Liquid Chromatography, Anal. Chem., 69, 3140, 10.1021/ac970319a · DOI · Paper page
- Globig, 2005, Fully automated in-tube solid-phase microextraction for liquid samples coupled to gas chromatography, Anal. Bioanal. Chem., 381, 656, 10.1007/s00216-004-2939-9 · doi:10.1007/s00216-004-2939-9
- Silva, 2014, Microextraction by Packed Sorbent (MEPS) and Solid-Phase Microextraction (SPME) as Sample Preparation Procedures for the Metabolomic Profiling of Urine, Metabolites, 4, 71, 10.3390/metabo4010071 · DOI
- Kubinec, 2004, Needle concentrator for gas chromatographic determination of BTEX in aqueous samples, J. Chromatogr. B, 800, 295, 10.1016/j.jchromb.2003.09.009 · doi:10.1016/j.jchromb.2003.09.009
- Jochmann, M.A. (2006). Solventless extraction and enrichment methods for compound-specific isotope analysis. [Ph.D. Thesis, University of Tubingen].
- Kataoka, 2010, Recent developments and applications of microextraction techniques in drug analysis, Anal. Bioanal. Chem., 396, 339, 10.1007/s00216-009-3076-2 · DOI · Paper page
- Saito, 2003, Miniaturized sample preparation combined with liquid phase Separations, J. Chromatogr. A, 1000, 53, 10.1016/S0021-9673(03)00307-8 · DOI
- Zhang, 1995, Quantitative Extraction Using an Internally Cooled Solid Phase Microextraction Device, Anal. Chem., 67, 34, 10.1021/ac00097a007 · DOI · Paper page
- Chen, 2006, Miniaturization and Automation of an Internally Cooled Coated Fiber Device, Anal. Chem., 78, 5222, 10.1021/ac060542k · doi:10.1021/ac060542k
- Ghiasvand, 2006, New cold-fiber headspace solid-phase microextraction device for quantitative extraction of polycyclic aromatic hydrocarbons in sediment, J. Chromatogr. A, 1124, 35, 10.1016/j.chroma.2006.04.088 · DOI
- Carasek, 2006, Screening of Tropical Fruit Volatile Compounds Using Solid-Phase Microextraction (SPME) Fibers and Internally Cooled SPME Fiber, J. Agric. Food Chem., 54, 8688, 10.1021/jf0613942 · DOI · Paper page
- Carasek, 2007, Fast and sensitive method to determine chloroanisoles in cork using an internally cooled solid-phase microextraction fiber, J. Chromatogr. A, 1138, 10, 10.1016/j.chroma.2006.10.092 · DOI
- Mirnaghi, 2013, Thin-Film Microextraction Coupled with Mass Spectrometry and Liquid Chromatography–Mass Spectrometry, Chromatographia, 76, 1215, 10.1007/s10337-013-2443-5 · DOI
- Jiang, 2012, Thin-film microextraction offers another geometry for solid-phase microextraction, TrAC Trends Anal. Chem., 39, 245, 10.1016/j.trac.2012.07.005 · DOI · Paper page
- Koziel, 2001, Sampling and Analysis of Airborne Particulate Matter and Aerosols Using In-Needle Trap and SPME Fiber Devices, Anal. Chem., 73, 47, 10.1021/ac000835s · DOI · Paper page
- Wang, 2005, Sampling and determination of volatile organic compounds with needle trap devices, J. Chromatogr. A, 1072, 127, 10.1016/j.chroma.2004.12.064 · DOI
- Saito, 2006, In-needle extraction device designed for gas chromatographic analysis of volatile organic compounds, J. Chromatogr. A, 1106, 190, 10.1016/j.chroma.2005.08.048 · doi:10.1016/j.chroma.2005.08.048
- Ampuero, 2004, Classification of unifloral honeys with an MS-based electronic nose using different sampling modes: SHS, SPME and INDEX, Eur. Food Res. Technol., 218, 198, 10.1007/s00217-003-0834-9 · doi:10.1007/s00217-003-0834-9
- Lipinski, 2001, Automated solid phase dynamic extraction—Extraction of organics using a wall coated syringe needle, Fresenius. J. Anal. Chem., 369, 57, 10.1007/s002160000618 · DOI
- Balasubramanian, 2011, Solid-Phase Microextraction (SPME) Techniques for Quality Characterization of Food Products: A Review, Food Bioprocess Technol., 4, 1, 10.1007/s11947-009-0299-3 · DOI · Paper page
- Nilsson, 1997, Inter-laboratory studies for the validation of solid-phase microextraction for the quantitative analysis of volatile organic compounds in aqueous samples, Anal. Chim. Acta, 356, 113, 10.1016/S0003-2670(97)00526-6 · doi:10.1016/s0003-2670(97)00526-6
- Bene, 2002, Applicability of a SPME method for the rapid determination of VOCs, Chimia, 56, 289, 10.2533/000942902777680315 · doi:10.2533/000942902777680315
- Basheer, 2004, Hollow fiber membrane-protected solid phase microextraction of triazine herbicides in bovine milk and sewage sludge samples, J. Chromatogr. A, 1047, 189, 10.1016/S0021-9673(04)01140-9 · doi:10.1016/s0021-9673(04)01140-9
- Razote, 2002, Dynamic air sampling of volatile organic compounds using solid phase microextraction, J. Environ. Sci. Health Part B, 37, 365, 10.1081/PFC-120004477 · doi:10.1081/pfc-120004477
- Razote, 2004, Characterization of volatile organic compounds on airborne dust in a swine finishing barn, Transac. ASAE, 47, 1231, 10.13031/2013.16573 · doi:10.13031/2013.16573
- Parreira, 2002, Evaluation of indoor exposition to benzene, toluene, ethylbenzene, xylene and styrene by passive sampling with a solid-phase microextraction device, J. Chromatogr. Sci., 40, 122, 10.1093/chromsci/40.3.122 · doi:10.1093/chromsci/40.3.122
- Jung, 2003, Headspace solid-phase microextraction method for the study of the volatility of selected flavor compounds, J. Agric. Food Chem., 51, 200, 10.1021/jf020651+ · DOI
- Issaq, H.J. (2002). A century of Separation Science, Marcel Dekker, Inc. · doi:10.1201/9781482270921
- Pena-Pereira, F. (2014). Miniaturization in Sample Preparation, De Gruyter Open. · DOI
- Pawliszyn, J. (2012). Handbook of solid phase Microextraction, Elsevier Inc. [1st ed.]. · doi:10.1016/b978-0-12-416017-0.00002-4
- Lord, 2008, Strategies for interfacing solid-phase microextraction with liquid chromatography, J. Chromatogr. A, 1152, 2, 10.1016/j.chroma.2006.11.073 · DOI
- Tong, 2002, Solid phase microextraction with matrix assisted laser desorption/ionization introduction to mass spectrometry and ion mobility spectrometry, Analyst, 127, 1207, 10.1039/b204701b · doi:10.1039/b204701b
- Stalikas, 2008, Microextraction combined with derivatization, TrAC Trends Anal. Chem., 27, 533, 10.1016/j.trac.2008.04.005 · DOI
- Pan, 1997, Derivatization/Solid-Phase Microextraction: New Approach to Polar Analytes, Anal. Chem., 69, 196, 10.1021/ac9606362 · DOI · Paper page
- Pizarro, 2005, Multiple solid-phase microextraction in a non-equilibrium situation Application in quantitative analysis of chlorophenols and chloroanisoles related to cork taint in wine, J. Chromatogr. A, 1089, 31, 10.1016/j.chroma.2005.06.063 · doi:10.1016/j.chroma.2005.06.063
- Bianchi, 2007, Fish and food safety: Determination of formaldehyde in 12 fish species by SPME extraction and GC–MS analysis, Food Chem., 100, 1049, 10.1016/j.foodchem.2005.09.089 · DOI · Paper page
- Bourdin, 2014, Development of SPME on-fiber derivatization for the sampling of formaldehyde and other carbonyl compounds in indoor air, Anal. Bioanal. Chem., 406, 317, 10.1007/s00216-013-7460-6 · DOI
- Ellis, 2007, Determination of organophosphorus fire retardants and plasticizers in wastewater samples using MAE-SPME with GC-ICPMS and GC-TOFMS detection, J. Environ. Monit., 9, 1329, 10.1039/b710667j · DOI
- Devos, 2005, Automated headspace-solid-phase micro extraction–retention time locked-isotope dilution gas chromatography–mass spectrometry for the analysis of organotin compounds in water and sediment samples, J. Chromatogr. A, 1079, 408, 10.1016/j.chroma.2004.12.020 · DOI
- Ferreira, 2006, Automated analysis of 2-methyl-3-furanthiol and 3-mercaptohexyl acetate at ng L−1 level by headspace solid-phase microextracion with on-fibre derivatisation and gas chromatography–negative chemical ionization mass spectrometric determination, J. Chromatogr. A, 1121, 1, 10.1016/j.chroma.2006.04.029 · DOI
- Zhu, 2015, Quantification of Carbonyl Compounds Generated from Ozone-Based Food Colorants Decomposition Using On-Fiber Derivatization-SPME-GC-MS, Chromatography, 2, 1, 10.3390/chromatography2010001 · doi:10.3390/chromatography2010001
- Peter, 2009, Occurrence of dissolved and particle-bound taste and odor compounds in Swiss lake waters, Water Res., 43, 2191, 10.1016/j.watres.2009.02.016 · doi:10.1016/j.watres.2009.02.016
- Mousavi, 2007, Optimization of solid-phase microextraction of volatile phenols in water by a polyaniline-coated Pt-fiber using experimental design, Anal. Chim. Acta, 581, 71, 10.1016/j.aca.2006.08.001 · DOI
- Ji, 2006, Field analysis of benzene, toluene, ethylbenzene and xylene in water by portable gas chromatography–microflame ionization detector combined with headspace solid-phase microextraction, Talanta, 69, 894, 10.1016/j.talanta.2005.11.032 · doi:10.1016/j.talanta.2005.11.032
- Unceta, 2010, Multi-residue analysis of pharmaceutical compounds in wastewaters by dual solid-phase microextraction coupled to liquid chromatography electrospray ionization ion trap mass spectrometry, J. Chromatogr. A, 1217, 3392, 10.1016/j.chroma.2010.03.008 · doi:10.1016/j.chroma.2010.03.008
- Li, 2006, Determination of bisphenol A in landfill leachate by solid phase microextraction with headspace derivatization and gas chromatography-mass spectrophotometry, Chin. J. Anal. Chem., 34, 325, 10.1016/S1872-2040(06)60018-2 · doi:10.1016/s1872-2040(06)60018-2
- Mitani, 2005, Fully automated analysis of estrogens in environmental waters by in-tube solid-phase microextraction coupled with liquid chromatography–tandem mass spectrometry, J. Chromatogr. A, 1081, 218, 10.1016/j.chroma.2005.05.058 · DOI
- Gaca, 2006, Determination of epichlorohydrin in water and sewage samples, Talanta, 70, 1044, 10.1016/j.talanta.2006.02.017 · doi:10.1016/j.talanta.2006.02.017
- Larreta, 2007, Optimisation of the on-fibre derivatisation of volatile fatty acids in the simultaneous determination together with phenols and indoles in cow slurries, Anal. Bioanal. Chem., 389, 1603, 10.1007/s00216-007-1545-z · doi:10.1007/s00216-007-1545-z
- Alzaga, 2006, Development of a procedure for the determination of perfluorocarboxylic acids in sediments by pressurised fluid extraction, headspace solid-phase microextraction followed by gas chromatographic–mass spectrometric determination, J. Chromatogr. A, 1083, 1, 10.1016/j.chroma.2005.06.036 · DOI
- Carvalho, 2007, Headspace solid-phase micro-extraction and gas chromatography-ion trap tandem mass spectrometry method for butyltin analysis in sediments: Optimization and validation, Microchem. J., 87, 147, 10.1016/j.microc.2007.07.003 · DOI
- Quintana, 2006, Strategies for the microextraction of polar organic contaminants in water samples, Anal. Bioanal. Chem., 384, 1447, 10.1007/s00216-005-0242-z · DOI
- Wu, 2000, Automated in tube solid-phase microextraction coupled with HPLC–ES–MS for the determination of catechins and caffeine in tea, Analyst, 125, 2216, 10.1039/b006211l · DOI
- Yu, 1999, Theory of analyte extraction by selected porous polymer SPME fibres, Analyst, 124, 643, 10.1039/a808487d · DOI · Paper page
- Cai, 2001, Comparison of simultaneous distillation extraction and solid-phase microextraction for the determination of volatile flavor components, J. Chromatogr. A, 930, 1, 10.1016/S0021-9673(01)01187-6 · doi:10.1016/s0021-9673(01)01187-6
- Kleeberg, 2005, Development of a simple and sensitive method for the characterization of odorous waste gas emissions by means of solid-phase microextraction (SPME) and GC MS/olfactometry, Waste Manage., 25, 872, 10.1016/j.wasman.2005.07.003 · doi:10.1016/j.wasman.2005.07.003
- Huang, 2009, Preparation and application of ionic liquid-coated fused-silica capillary fibers for solid-phase microextraction, Anal. Chim. Acta, 645, 42, 10.1016/j.aca.2009.04.037 · DOI
- He, 2009, Preparation of ionic liquid based solid-phase microextraction fiber and its application to forensic determination of methamphetamine and amphetamine in human urine, J. Chromatogr. A, 1216, 4824, 10.1016/j.chroma.2009.04.028 · DOI
- Mullett, 2001, In-Tube Molecularly Imprinted Polymer Solid-Phase Microextraction for the Selective Determination of Propranolol, Anal. Chem., 73, 2383, 10.1021/ac0100502 · doi:10.1021/ac0100502
- Hofacker, 2002, Sol–gel: A new tool for coatings chemistry, Prog. Org. Coat., 45, 159, 10.1016/S0300-9440(02)00045-0 · doi:10.1016/s0300-9440(02)00045-0
- Mullett, 2002, Bio-compatible in-tube solid-phase microextraction capillary for the direct extraction and high-performance liquid chromatographic determination of drugs in human serum, J. Chromatogr. A, 963, 325, 10.1016/S0021-9673(02)00216-9 · DOI
- Chong, 1997, Sol-gel coating technology for the preparation of solid-phase microextraction fibers of enhanced thermal stability, Anal. Chem., 69, 3889, 10.1021/ac9703360 · DOI · Paper page
- Young, 2006, Sol-Gel Science for Ceramic Materials, Mater. Matt., 1, 8
- Pereira, F.P. (2014). Miniaturization in Sample Preparation, De Gruyter Open Ltd.
- Djozan, 2001, Anodized Aluminum Wire as a Solid-Phase Microextraction Fiber, Anal. Chem., 73, 4054, 10.1021/ac0100188 · DOI · Paper page
- Li, 2011, Electrosorption-enhanced solid-phase microextraction of trace anions using a platinum plate coated with single-walled carbon nanotubes, Talanta, 85, 1148, 10.1016/j.talanta.2011.05.042 · DOI
- Li, 2009, An organically modified silicate molecularly imprinted solid-phase microextraction device for the determination of polybrominated diphenyl ethers, Anal. Chim. Acta, 633, 197, 10.1016/j.aca.2008.11.060 · DOI
- Ma, 2011, Determination of endocrine-disrupting compounds in water by carbon nanotubes solid-phase microextraction fiber coupled online with high performance liquid chromatography, Talanta, 85, 2212, 10.1016/j.talanta.2011.07.066 · DOI
- Maghsoudi, 2012, HP-SPME of Volatile Polycyclic Aromatic Hydrocarbons from Water Using Multiwalled Carbon Nanotubes Coated on a Steel Fiber through Electrophoretic Deposition, Chromatographia, 75, 913, 10.1007/s10337-012-2283-8 · doi:10.1007/s10337-012-2283-8
- Zewe, 2010, Electrospun fibers for solid-phase microextraction, Anal. Chem., 82, 5341, 10.1021/ac100891t · doi:10.1021/ac100891t
- Lin, 2008, Preparation of a TiO2 nanoparticle-deposited capillary column by liquid phase deposition and its application in phosphopeptide analysis, J. Chromatogr. A, 1192, 95, 10.1016/j.chroma.2008.03.043 · doi:10.1016/j.chroma.2008.03.043
- Alizadeh, 2011, A new solid phase micro extraction for simultaneous head space extraction of ultra traces of polar and non-polar compounds, Anal. Chim. Acta, 689, 117, 10.1016/j.aca.2011.01.013 · doi:10.1016/j.aca.2011.01.013
- Ji, 2012, ZnO nanorod coating for solid phase microextraction and its applications for the analysis of aldehydes in instant noodle samples, J. Chromatogr. A, 1246, 22, 10.1016/j.chroma.2012.01.080 · DOI
- Farhadi, 2014, A novel dispersive micro solid phase extraction using zein nanoparticles as the sorbent combined with headspace solid phase micro-extraction to determine chlorophenols in water and honey samples by GC–ECD, Talanta, 128, 493, 10.1016/j.talanta.2014.06.002 · DOI
- Anbia, 2011, Ordered nanoporous carbon-based SPME and determination by GC, Chromatographia, 73, 379, 10.1007/s10337-010-1863-8 · doi:10.1007/s10337-010-1863-8
- Rahimi, 2011, CMK-3 nanoporous carbon as a new fiber coating for solid-phase microextraction coupled to gas chromatography–mass spectrometry, Anal. Chim. Acta, 695, 58, 10.1016/j.aca.2011.03.037 · doi:10.1016/j.aca.2011.03.037
- Toledo, 2014, A chemometric approach toward the detection and quantification of coffee adulteration by solid-phase microextraction using polymericionic liquid sorbent coatings, J. Chomatogr. A, 1346, 1, 10.1016/j.chroma.2014.04.035 · DOI
- Ho, 2012, Determination of chlorophenols in landfill leachate using headspace sampling with ionic liquid-coated solid-phase microextraction fibers combined with gas chromatography–mass spectrometry, Anal. Chim. Acta, 712, 72, 10.1016/j.aca.2011.11.025 · DOI
- Yang, 2012, Determination of diethylstilbestrol in milk using carbon nanotube-reinforced hollow fiber solid-phase microextraction combined with high-performance liquid chromatography, Talanta, 97, 222, 10.1016/j.talanta.2012.04.021 · DOI
- Abbasian, 2012, Determination of furan in food samples using two solid phase microextraction fibers based on sol–gel technique with gas chromatography–flame ionization detector, Food Chem., 131, 698, 10.1016/j.foodchem.2011.09.019 · doi:10.1016/j.foodchem.2011.09.019
- Attari, 2014, Solid-phase microextraction fiber development for sampling and analysis of volatile organohalogen compounds in air, J. Environ. Health Sci. Eng., 12, 123, 10.1186/s40201-014-0123-5 · DOI
- Shearrow, 2009, Ionic liquid-mediated Sol-gel coatings for capillary microextraction, J. Chomatogr. A, 1216, 5449, 10.1016/j.chroma.2009.04.093 · DOI
- Shearrow, 2009, Ionic liquid-mediated bis(3-methyldimethoxysilyl)propyl. polypropylene oxide-based polar Sol-gel coatings for capillary microextraction, J. Chromatogr. A, 1216, 6349, 10.1016/j.chroma.2009.07.028 · DOI
- Zhou, 2012, Thermally stable ionic liquid-based Sol-gel coating for ultrasonic extraction–solid-phase microextraction–gas chromatography determination of phthalate esters in agricultural plastic films, Talanta, 89, 129, 10.1016/j.talanta.2011.12.001 · DOI
- Liu, 2010, Innovative chemically bonded ionic liquids-based Sol-gel coatings as highly porous, stable and selective stationary phases for solid phase microextraction, Anal. Chim. Acta, 683, 96, 10.1016/j.aca.2010.10.004 · DOI
- Fan, 2005, Ordered mesoporous silica coated capillary for in-tube solid phase microextraction coupled to high performance liquid chromatography, Anal. Chim. Acta, 543, 1, 10.1016/j.aca.2005.04.024 · doi:10.1016/j.aca.2005.04.024
- Zhu, 2012, Preparation and characterization of vinyl-functionalized mesoporous organosilica-coated solid-phase microextraction fiber, J. Chromatogr. A, 1247, 42, 10.1016/j.chroma.2012.05.055 · doi:10.1016/j.chroma.2012.05.055
- Moreira, 2015, Analysis of plasticiser migration to meat roasted in plastic bags by SPME–GC/MS, Food Chem., 178, 195, 10.1016/j.foodchem.2015.01.078 · DOI
- Hosseini, 2012, Development and application of a new solid-phase microextraction fiber by Solgel technology on titanium wire, Anal. Chim. Acta, 742, 74, 10.1016/j.aca.2012.04.018 · doi:10.1016/j.aca.2012.04.018
- Wang, 2013, Sol-gel molecularly imprinted polymer for selective solid phase microextraction of organophosphorous pesticides, Talanta, 115, 920, 10.1016/j.talanta.2013.06.056 · DOI
- Mu, 2013, Robust aptamer Sol-gel solid phase microextraction of very polar adenosine from human plasma, J. Chromatogr. A, 1279, 7, 10.1016/j.chroma.2013.01.002 · doi:10.1016/j.chroma.2013.01.002
- Liu, 2007, Oxidized multiwalled carbon nanotubes as a novel solid-phase microextraction fiber for determination of phenols in aqueous samples, J. Chromatogr. A, 1165, 10, 10.1016/j.chroma.2007.07.057 · DOI · Paper page
- Bagheri, 2011, Chemically bonded carbon nanotubes on modified gold substrate as novel unbreakable solid phase microextraction fiber, Microchim. Acta, 174, 295, 10.1007/s00604-011-0621-4 · doi:10.1007/s00604-011-0621-4
- Queiroz, 2007, Immunoaffinity in-tube solid phase microextraction coupled with liquid chromatography–mass spectrometry for analysis of fluoxetine in serum samples, J. Chromatogr. A, 1174, 72, 10.1016/j.chroma.2007.09.026 · DOI
- Hu, 2008, Preparation and evaluation of solid-phase microextraction fiber based on molecularly imprinted polymers for trace analysis of tetracyclines in complicated samples, J. Chromatogr. A, 1188, 97, 10.1016/j.chroma.2008.02.062 · doi:10.1016/j.chroma.2008.02.062
- Djozan, 2012, Determination of methamphetamine, amphetamine and ecstasy by inside-needle adsorption trap based on molecularly imprinted polymer followed by GC-FID determination, Microchim. Acta, 179, 209, 10.1007/s00604-012-0879-1 · DOI
- Amini, 2011, A novel reusable ionic liquid chemically bonded fused-silica fiber for headspace solid-phase microextraction/gas chromatography-flame ionization detection of methyl tert-butyl ether in a gasoline sample, J. Chromatogr. A, 1218, 130, 10.1016/j.chroma.2010.10.114 · DOI
- Pang, 2012, Development of a solid-phase microextraction fiber by chemical binding of polymeric ionic liquid on a silica coated stainless steel wire, J. Chromatogr. A, 1230, 8, 10.1016/j.chroma.2012.01.052 · DOI
- Tamer, 2005, Electrochemically controlled solid-phase microextraction (EC-SPME) based on overoxidized sulfonated polypyrrole, Talanta, 67, 245, 10.1016/j.talanta.2005.03.003 · doi:10.1016/j.talanta.2005.03.003
- Banitaba, 2011, Preparation and evaluation of a novel solid-phase microextraction fiber based on poly(3,4-ethylenedioxythiophene) for the analysis of OCPs in water, Anal. Methods, 3, 2061, 10.1039/c1ay05142c · DOI
- Bagheri, 2005, An electropolymerized aniline-based fiber coating for solid phase microextraction of phenols from water, Anal. Chim. Acta, 532, 89, 10.1016/j.aca.2004.10.040 · DOI · Paper page
- Chen, 2011, Electropolymerized multiwalled carbon nanotubes/polypyrrole fiber for solid-phase microextraction and its applications in the determination of pyrethroids, Talanta, 84, 104, 10.1016/j.talanta.2010.12.027 · doi:10.1016/j.talanta.2010.12.027
- Mehdinia, 2014, Fibers coated with a graphene-polyaniline nanocomposite for the headspace solid-phase microextraction of organochlorine pesticides from seawater samples, Microchim. Acta, 181, 89, 10.1007/s00604-013-1071-y · DOI
- Zhao, 2011, Electrochemical preparation of polyaniline–ionic liquid based solid phase microextraction fiber and its application in the determination of benzene derivatives, J. Chromatogr. A, 1218, 387, 10.1016/j.chroma.2010.12.017 · doi:10.1016/j.chroma.2010.12.017
- Gao, 2011, Nanostructured polyaniline-ionic liquid composite film coated steel wire for headspace solid-phase microextraction of organochlorine pesticides in water, J. Chromatogr. A, 1218, 6285, 10.1016/j.chroma.2011.07.041 · DOI
- Mehdinia, 2006, Nano-structured lead dioxide as a novel stationary phase for solid-phase microextraction, J. Chromatogr. A, 1134, 24, 10.1016/j.chroma.2006.08.087 · DOI
- Budziak, 2009, Application of an NiTi alloy coated with ZrO2 solid-phase microextraction fiber for determination of haloanisoles in red wine samples, Microchim. Acta, 164, 197, 10.1007/s00604-008-0057-7 · doi:10.1007/s00604-008-0057-7
- Liu, 2010, A novel TiO2 nanotube array/Ti wire incorporated solid-phase microextraction fiber with high strength, efficiency and selectivity, J. Chromatogr. A, 1217, 1898, 10.1016/j.chroma.2010.01.080 · doi:10.1016/j.chroma.2010.01.080
- Cao, 2008, In situ fabrication of nanostructured titania coating on the surface of titaniumwire: A new approach for preparation of solid-phase microextraction fiber, Anal. Chim. Acta, 611, 56, 10.1016/j.aca.2008.01.067 · DOI
- Bagheri, 2012, Novel polyamide-based nanofibers prepared by electrospinning technique for headspace solid-phase microextraction of phenol and chlorophenols from environmental samples, Anal. Chim. Acta, 716, 34, 10.1016/j.aca.2011.03.016 · DOI
- Newsome, 2012, Electrospun nanofibrous solid-phase microextraction coatings for preconcentration of pharmaceuticals prior to liquid chromatographic separations, J. Chromatogr. A, 1262, 1, 10.1016/j.chroma.2012.08.046 · doi:10.1016/j.chroma.2012.08.046
- Yu, 2011, Temperature-response polymer coating for in-tube solid-phase microextraction coupled to highperformance, Talanta, 84, 1019, 10.1016/j.talanta.2011.03.003 · doi:10.1016/j.talanta.2011.03.003
- Bagheri, 2008, A novel sol–gel-based amino-functionalized fiber for headspace solid-phase microextraction of phenol and chlorophenols from environmental samples, Anal. Chim. Acta, 616, 49, 10.1016/j.aca.2008.04.008 · doi:10.1016/j.aca.2008.04.008
- Zeng, 2008, Application of ceramic/carbon composite as a novel coating for solid-phase Microextraction, J. Chromatogr. A, 1188, 26, 10.1016/j.chroma.2007.08.017 · DOI
- Januszkiewicz, 2008, Optimization of headspace solid-phase microextraction for the analysis of specific flavors in enzyme modified and natural Cheddar cheese using factorial design and response surface methodology, J. Chromatogr. A, 1195, 16, 10.1016/j.chroma.2008.04.067 · DOI
- 2007, Multiple pesticide analysis in wine by MEKC combined with solid-phase microextraction and sample stacking, Electrophoresis, 28, 4072, 10.1002/elps.200700251 · DOI
- Perfetti, 2008, Analysis of tetramethylene disulfotetramine in foods using solid-phase microextraction–gas chromatography–mass spectrometry, J. Chromatogr. A, 1192, 36, 10.1016/j.chroma.2008.03.042 · DOI
- Saison, 2008, Optimisation of a complete method for the analysis of volatiles involved in the flavour stability of beer by solid-phase microextraction in combination with gas chromatography and mass spectrometry, J. Chromatogr. A, 1190, 342, 10.1016/j.chroma.2008.03.015 · doi:10.1016/j.chroma.2008.03.015
- Iglesias, 2008, Solid-phase microextraction method for the determination of volatile compounds associated to oxidation of fish muscle, J. Chromatogr. A, 1192, 9, 10.1016/j.chroma.2008.03.028 · doi:10.1016/j.chroma.2008.03.028
- Plutowska, 2008, Determination of volatile fatty acid ethyl esters in raw spirits using solid phase microextraction and gas chromatography, Anal. Chim. Acta, 613, 64, 10.1016/j.aca.2008.02.054 · doi:10.1016/j.aca.2008.02.054
- Nollet, 2006, Organic Acids, Chromatographic Analysis of the Environment, Volume 93, 453
- Pawliszyn, J. (1999). Applications of Solid Phase Microextraction, The Royal Society of Chemistry. · DOI · Paper page
- Bocchini, 2015, Quantitative determination of dimethyl fumarate in silica gel by solid-phase microextraction/gas chromatography/mass spectrometry and ultrasound-assisted extraction/gas chromatography/mass spectrometry, Environ. Monit. Assess., 187, 320, 10.1007/s10661-015-4567-6 · doi:10.1007/s10661-015-4567-6
- Ezquerro, 2003, Direct quantitation of volatile organic compounds in packaging materials by headspace solid-phase microextraction-gas chromatography-mass spectrometry, J. Chromatogr. A, 985, 247, 10.1016/S0021-9673(02)01829-0 · doi:10.1016/s0021-9673(02)01829-0
- Wu, 2000, Volatile Compounds in Fresh and Processed Shiitake Mushrooms (Lentinus edodes Sing.), Food Sci. Technol. Res., 6, 166, 10.3136/fstr.6.166 · DOI
- Djozan, 2008, Ultrasonic assisted SPME coupled with GC and GC-MS using pencil lead as a fiber for monitoring the organic volatile impurities of ceftazidime, J. Chromatogr. Sci., 46, 680, 10.1093/chromsci/46.8.680 · doi:10.1093/chromsci/46.8.680
- Nollet, 2006, Polycyclic Aromatic Hydrocarbons, Chromatographic Analysis of the Environment, Volume 93, 555
- Luukkonen, V. (2012). Determination of chlorophenols from water by solid phase microextraction—Ion mobility spectrometry (SPME-IMS). [Master’s thesis, Lappeenranta University of Technology].
- Larroque, 2006, Development of a solid phase microextraction (SPME) method for the sampling of VOC traces in indoor air, J. Environ. Monit., 8, 106, 10.1039/B511201J · DOI
- Qin, 2008, Comparison of thin-film microextraction and stir bar sorptive extraction for the analysis of polycyclic aromatic hydrocarbons in aqueous samples with controlled agitation conditions, J. Chromatogr. A, 89, 1196
- Flores, 2007, Optimization of Multiple Headspace Solid-Phase Microextraction for the Quantification of Volatile Compounds in Dry Fermented Sausages, J. Agric. Food Chem., 55, 8688, 10.1021/jf0713758 · doi:10.1021/jf0713758
- Paschke, 2006, Comparative application of solid-phase microextraction fibre assemblies and semi-permeable membrane devices as passive air samplers for semi-volatile chlorinated organic compounds. A case study on the landfill ‘‘Grube Antonie’’ in Bitterfeld, Germany, Environ. Pollut., 144, 414, 10.1016/j.envpol.2005.12.046 · DOI
- Ouyang, 2007, Time-weighted average water sampling with a diffusion-based solid-phase microextraction device, J. Chromatogr. A, 1138, 42, 10.1016/j.chroma.2006.10.094 · doi:10.1016/j.chroma.2006.10.094
- Koziel, 2000, Air Sampling with Porous Solid-Phase Microextraction Fibers, Anal. Chem., 72, 5178, 10.1021/ac000518l · DOI
- Chen, 2003, Calibration for On-Site Analysis of Hydrocarbons in Aqueous and Gaseous Samples Using Solid-Phase Microextraction, Anal. Chem., 75, 6485, 10.1021/ac0349328 · doi:10.1021/ac0349328
- Zhao, 2006, On-rod standardization technique for time-weighted average water sampling with a polydimethylsiloxane rod, J. Chromatogr. A, 1124, 112, 10.1016/j.chroma.2006.05.062 · DOI
- Bragg, 2006, Field Sampling with a Polydimethylsiloxane Thin-Film, J. Chromatogr. Sci., 44, 317, 10.1093/chromsci/44.6.317 · DOI
- Ouyang, 2008, Standard-free kinetic calibration for rapid on-site analysis by solid-phase microextraction, J. Sep. Sci., 31, 1167, 10.1002/jssc.200700495 · doi:10.1002/jssc.200700495
- Khaled, 2000, Time-weighted average sampling of volatile and semi-volatile airborne organic compounds by the solid-phase Microextraction device, J. Chromatogr. A, 892, 455, 10.1016/S0021-9673(00)00295-8 · doi:10.1016/s0021-9673(00)00295-8
- Chen, 2004, Standards in the extraction phase, a new approach to calibration of Microextraction processes, Analyst, 129, 702, 10.1039/b406310d · DOI
- Zhao, 2007, and application of in-fibre internal standardization solid-phase microextraction, Analyst, 132, 256, 10.1039/b612604a · doi:10.1039/b612604a
- Maarse, H., and Groenen, P.J. (1975, January 26–29). The future of aroma research. Aroma Research; Proceedings of the International Symposium on Aroma Research, Central Institute for Nutrition and Food Research TNO, Zeist, Netherlands.
- Pawliszyn, 2003, Sample Preparation: Quo Vadis?, Anal. Chem., 75, 2543, 10.1021/ac034094h · DOI · Paper page
- Ferreira, 2004, Doehlert matrix: A chemometric tool for analytical chemistry—Review, Talanta, 63, 1061, 10.1016/j.talanta.2004.01.015 · DOI · Paper page
- Risticevic, 2008, Headspace solid-phase microextraction–gas chromatographic–time-of-flight mass spectrometric methodology for geographical origin verification of coffee, Anal. Chim. Acta, 617, 72, 10.1016/j.aca.2008.04.009 · DOI
- Chen, 2010, Determination of Diacetyl in Butter and Air Samples by SPME Coupled with GC–MS, Chromatographia, 72, 999, 10.1365/s10337-010-1739-y · doi:10.1365/s10337-010-1739-y
- Mallia, 2005, Comparison of purge and trap and solid phase microextraction techniques for studying the volatile aroma compounds of three European PDO hard cheeses, Int. Dairy J., 15, 741, 10.1016/j.idairyj.2004.11.007 · DOI
- Majcher, M.A., Kaczmarek, A., Klensporf-Pawlik, D., Pikul, J., and Jeleń, H.H. (2015). SPME-MS-Based Electronic Nose as a Tool for Determination of Authenticity of PDO Cheese, Oscypek. Food Anal. Methods. · doi:10.1007/s12161-015-0114-x
- Ocak, E., Javidipour, I., and Tuncturk, Y. (2014). Volatile compounds of Van Herby cheeses produced with raw and pasteurized milks from different species. J. Food Sci. Technol. · DOI
- Tunick, 2013, Comparison of SPME Methods for Determining Volatile Compounds in Milk, Cheese, and Whey Powder, Foods, 2, 534, 10.3390/foods2040534 · DOI
- Xie, 2008, Volatile flavor constituents in roasted pork of Mini-pig, Food Chem., 109, 506, 10.1016/j.foodchem.2007.12.074 · DOI
- Yu, 2008, Analysis of volatile compounds in traditional smoke-cured bacon (CSCB) with different fiber coatings using SPME, Food Chem., 110, 233, 10.1016/j.foodchem.2008.01.040 · doi:10.1016/j.foodchem.2008.01.040
- Argyri, 2015, The dynamics of the HS/SPME–GC/MS as a tool to assess the spoilage of minced beef stored under different packaging and temperature conditions, Int. J. Food Microbiol., 193, 51, 10.1016/j.ijfoodmicro.2014.09.020 · DOI
- Benet, 2015, Analysis of SPME or SBSE extracted volatile compounds from cooked cured pork ham differing in intramuscular fat profiles, Food Sci. Technol., 60, 393
- Corral, 2013, Salt reduction in slow fermented sausages affects the generation of aroma active compounds, Meat Sci., 93, 776, 10.1016/j.meatsci.2012.11.040 · doi:10.1016/j.meatsci.2012.11.040
- Gardini, 2013, Biogenic amine content and aromatic profile of Salama da sugo, a typical cooked fermented sausage produced in Emilia Romagna Region (Italy), Food Control, 32, 638, 10.1016/j.foodcont.2013.01.039 · DOI
- Ma, 2013, Optimization of headspace solid phase microextraction (HS-SPME) for gas chromatography mass spectrometry (GC–MS) analysis of aroma compounds in cooked beef using response surface methodology, Microchem. J., 111, 16, 10.1016/j.microc.2012.10.007 · DOI
200 of 377 shown
Cited by
Current Nucleic Acid Extraction Methods and Their Implications to Point-of-Care Diagnostics
Ali, N., Rampazzo, R. D. C. P., Costa, A. D. T., & Krieger, M. A. (2017) · BioMed Research International · doi:10.1155/2017/9306564 · Cited by 359
A comprehensive look at solid-phase microextraction technique: A review of reviews
Jalili, V., Barkhordari, A., & Ghiasvand, A. (2020) · Microchemical Journal · doi:10.1016/j.microc.2019.104319 · Cited by 317
Traditional and innovative approaches for the extraction of bioactive compounds
Usman, I., Hussain, M., Imran, A., Afzaal, M., Saeed, F., Javed, M., Afzal, A., Ashfaq, I., Al Jbawi, E., & A. Saewan, S. (2022) · International Journal of Food Properties · doi:10.1080/10942912.2022.2074030 · Cited by 209
Katrak, V. K., Patel, N. A., & Ijardar, S. P. (2026) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2025.2486209 · Cited by 16
Kolawole, O., Thammakhet-Buranachai, C., Petchkongkaew, A., Sooksimuang, T., Elliott, C., & Karoonuthaisiri, N. (2024) · Green Chemistry Letters and Reviews · doi:10.1080/17518253.2024.2427797 · Cited by 10
“In the second approach, also known as direct immersion (DI-SPME), the coated fiber is immersed in a small volume of the liquid sample to extract both non-volatile and semi-volatile compounds (52).”
Influential
Metadata
- Authors
- Merkle, S., Kleeberg, K., & Fritsche, J.
- Venue
- Chromatography
- Publisher
- MDPI AG
- Published
- 2015-06-30
- Volume
- 2
- Issue
- 3
- Pages
- 293-381
- ISSN
- 2227-9075 (ISSN-L)
- OpenAlex
- W1483433471
- Cited by
- 250
- References
- 2
- FWCI
- 10.26
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Recent Developments and Applications of Solid Phase Microextraction (SPME) in Food and Environmental Analysis—A Review. https://app.cochat.ai/papers/10.3390/chromatography2030293
- The paper
- Merkle, S., Kleeberg, K., & Fritsche, J. (2015). Recent Developments and Applications of Solid Phase Microextraction (SPME) in Food and Environmental Analysis—A Review. Chromatography. https://doi.org/10.3390/chromatography2030293
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.