Biological Matrix Effects in Quantitative Tandem Mass Spectrometry-Based Analytical Methods: Advancing Biomonitoring
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
The ability to quantify levels of target analytes in biological samples accurately and precisely in biomonitoring involves the use of highly sensitive and selective instrumentation such as tandem mass spectrometers and a thorough understanding of highly variable matrix effects. Typically, matrix effects are caused by co-eluting matrix components that alter the ionization of target analytes as well as the chromatographic response of target analytes, leading to reduced or increased sensitivity of the analysis. Thus, before the desired accuracy and precision standards of laboratory data are achieved, these effects must be characterized and controlled. Here we present our review and observations of matrix effects encountered during the validation and implementation of tandem mass spectrometry-based analytical methods. We also provide systematic, comprehensive laboratory strategies needed to control challenges posed by matrix effects in order to ensure delivery of the most accurate data for biomonitoring studies assessing exposure to environmental toxicants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Matuszewski, B. K., Constanzer, M. L., & Chavez-Eng, C. M. (2003) · Analytical Chemistry · doi:10.1021/ac020361s · Cited by 5,335
Taylor, P. J. (2005) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2004.11.007 · Cited by 1,248
Mechanistic investigation of ionization suppression in electrospray ionization
King, R., Bonfiglio, R., Fernandez-Metzler, C., Miller-Stein, C., & Olah, T. (2000) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(00)00163-x · Cited by 1,086
Bonfiglio, R., King, R. C., Olah, T. V., & Merkle, K. (1999) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19990630)13:12<1175::aid-rcm639>3.0.co;2-0 · Cited by 939
Viswanathan, C. T., Bansal, S., Booth, B., DeStefano, A. J., Rose, M. J., Sailstad, J., Shah, V. P., Skelly, J. P., Swann, P. G., & Weiner, R. (2007) · Pharmaceutical Research · doi:10.1007/s11095-007-9291-7 · Cited by 826
Systematic and comprehensive strategy for reducing matrix effects in LC/MS/MS analyses
Chambers, E., Wagrowski-Diehl, D. M., Lu, Z., & Mazzeo, J. R. (2007) · Journal of Chromatography B · doi:10.1016/j.jchromb.2006.12.030 · Cited by 776
Validation of bioanalytical LC–MS/MS assays: Evaluation of matrix effects
Van Eeckhaut, A., Lanckmans, K., Sarre, S., Smolders, I., & Michotte, Y. (2009) · Journal of Chromatography B · doi:10.1016/j.jchromb.2009.01.003 · Cited by 763
Dams, R., Huestis, M. A., Lambert, W. E., & Murphy, C. M. (2003) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(03)00574-9 · Cited by 600
Schmidt, A., Karas, M., & Dülcks, T. (2003) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(03)00128-4 · Cited by 534
Ion suppression; A critical review on causes, evaluation, prevention and applications
Furey, A., Moriarty, M., Bane, V., Kinsella, B., & Lehane, M. (2013) · Talanta · doi:10.1016/j.talanta.2013.03.048 · Cited by 521
Tang, L., & Kebarle, P. (1993) · Analytical Chemistry · doi:10.1021/ac00072a020 · Cited by 506
Matrix effects in (ultra)trace analysis of pesticide residues in food and biotic matrices
Hajšlová, J., & Zrostlı́ková, J. (2003) · Journal of Chromatography A · doi:10.1016/s0021-9673(03)00539-9 · Cited by 441
Antignac, J., Wasch, K. D., Monteau, F., Brabander, H. D., Andre, F., & Bizec, B. L. (2004) · Analytica Chimica Acta · doi:10.1016/j.aca.2004.08.055 · Cited by 420
Nutrient Composition of Human Milk
Picciano, M. F. (2001) · Pediatric Clinics of North America · doi:10.1016/s0031-3955(05)70285-6 · Cited by 369
Mei, H., Hsieh, Y., Nardo, C., Xu, X., Wang, S., Ng, K., & Korfmacher, W. A. (2003) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.876 · Cited by 350
Erney, D. R., Gillespie, A. M., Gilvydis, D. M., & Poole, C. F. (1993) · Journal of Chromatography A · doi:10.1016/0021-9673(93)85007-t · Cited by 326
LITTLE, J., WEMPE, M., & BUCHANAN, C. (2006) · Journal of Chromatography B · doi:10.1016/j.jchromb.2006.02.011 · Cited by 256
González, O., Blanco, M. E., Iriarte, G., Bartolomé, L., Maguregui, M. I., & Alonso, R. M. (2014) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.03.077 · Cited by 253
Overcoming Matrix Effects in Liquid Chromatography−Mass Spectrometry
Cappiello, A., Famiglini, G., Palma, P., Pierini, E., Termopoli, V., & Trufelli, H. (2008) · Analytical Chemistry · doi:10.1021/ac8018312 · Cited by 253
Xia, Y., & Jemal, M. (2009) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.4121 · Cited by 219
Schenck, F. J., & Lehotay, S. J. (2000) · Journal of Chromatography A · doi:10.1016/s0021-9673(99)01137-1 · Cited by 210
Olsson, A. O., Baker, S. E., Nguyen, J. V., Romanoff, L. C., Udunka, S. O., Walker, R. D., Flemmen, K. L., & Barr, D. B. (2004) · Analytical Chemistry · doi:10.1021/ac0355404 · Cited by 205
Self-citationGARCIA, M. (2005) · Journal of Chromatography B · doi:10.1016/j.jchromb.2005.03.041 · Cited by 198
Hewavitharana, A. K. (2011) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.11.047 · Cited by 179
Matrix Effects—A Challenge toward Automation of Molecular Analysis
Chiu, M. L., Lawi, W., Snyder, S. T., Wong, P. K., Liao, J. C., & Gau, V. (2010) · JALA: Journal of the Association for Laboratory Automation · doi:10.1016/j.jala.2010.02.001 · Cited by 175
Ismaiel, O. A., Zhang, T., Jenkins, R. G., & Karnes, H. T. (2010) · Journal of Chromatography B · doi:10.1016/j.jchromb.2010.10.012 · Cited by 173
Berg, T., & Strand, D. H. (2011) · Journal of Chromatography A · doi:10.1016/j.chroma.2011.10.081 · Cited by 158
System suitability in bioanalytical LC/MS/MS
Briscoe, C. J., Stiles, M. R., & Hage, D. S. (2007) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2007.03.003 · Cited by 109
Sterner, J. L., Johnston, M. V., Nicol, G. R., & Ridge, D. P. (2000) · Journal of Mass Spectrometry · doi:10.1002/(sici)1096-9888(200003)35:3<385::aid-jms947>3.0.co;2-o · Cited by 99
Colby, B. N., & McCaman, M. W. (1979) · Journal of Mass Spectrometry · doi:10.1002/bms.1200060602 · Cited by 91
Whitehead, R. D., Montesano, M. A., Jayatilaka, N. K., Buckley, B., Winnik, B., Needham, L. L., & Barr, D. B. (2009) · Journal of Chromatography B · doi:10.1016/j.jchromb.2009.09.029 · Cited by 75
Self-citationHemorheological Changes during Human Aging
Ajmani, R. S., & Rifkind, J. M. (1998) · Gerontology · doi:10.1159/000021993 · Cited by 62
Montesano, M. A., Olsson, A. O., Kuklenyik, P., Needham, L. L., Bradman, A., & Barr, D. B. (2007) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/sj.jes.7500550 · Cited by 55
Self-citationUrine albumin measurement: Effects of urine matrix constituents
Sviridov, D. O., & Hortin, G. L. (2009) · Clinica Chimica Acta · doi:10.1016/j.cca.2009.03.034 · Cited by 28
Cited by
Matrix Effects and Application of Matrix Effect Factor
Zhou, W., Yang, S., & Wang, P. G. (2017) · Bioanalysis · doi:10.4155/bio-2017-0214 · Cited by 430
Robust, reproducible and quantitative analysis of thousands of proteomes by micro-flow LC–MS/MS
Bian, Y., Zheng, R., Bayer, F. P., Wong, C., Chang, Y.-C., Meng, C., Zolg, D. P., Reinecke, M., Zecha, J., Wiechmann, S., et al. (2020) · Nature Communications · doi:10.1038/s41467-019-13973-x · Cited by 345
Burla, B., Arita, M., Arita, M., Bendt, A. K., Cazenave-Gassiot, A., Dennis, E. A., Ekroos, K., Han, X., Ikeda, K., Liebisch, G., et al. (2018) · Journal of Lipid Research · doi:10.1194/jlr.s087163 · Cited by 312
Intestinal microbiota-derived tryptophan metabolites are predictive of Ah receptor activity
Dong, F., Hao, F., Murray, I. A., Smith, P. B., Koo, I., Tindall, A. M., Kris-Etherton, P. M., Gowda, K., Amin, S. G., Patterson, A. D., et al. (2020) · Gut Microbes · doi:10.1080/19490976.2020.1788899 · Cited by 245
“The matrix effect is caused by the components coextracted with the analytes which could suppress or enhance the signal response of target analytes.(39,40) Matrix effect could lead to poor analytical accuracy of quantification of an analyte.”
BackgroundBiomonitoring in the Era of the Exposome
Dennis, K. K., Marder, E., Balshaw, D. M., Cui, Y., Lynes, M. A., Patti, G. J., Rappaport, S. M., Shaughnessy, D. T., Vrijheid, M., & Barr, D. B. (2017) · Environmental Health Perspectives · doi:10.1289/ehp474 · Cited by 236
“…untargeted analysis can be combined with advanced bioinformatic techniques to help prioritize risk assessment, to determine which exposures often co-occur, and to establish markers of disease risk (Dennis et al. 2016; Johnson et al. 2015; Rager et al. 2016; Yu et al. 2013; Wambaugh et al. 2013).”
BackgroundSelf-citation
Metadata
- Authors
- Panuwet, P., Hunter, R. E., D'Souza, P. E., Chen, X., Radford, S. A., Cohen, J. R., Marder, M. E., Kartavenka, K., Ryan, P. B., & Barr, D. B.
- Venue
- Critical Reviews in Analytical Chemistry
- Publisher
- Informa UK Limited
- Published
- 2015-01-06
- Volume
- 46
- Issue
- 2
- Pages
- 93-105
- ISSN
- 1040-8347 (ISSN-L)
- 1547-6510
- OpenAlex
- W1993575423
- Cited by
- 394
- References
- 34
- FWCI
- 13.51
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.