The DOI matches its Crossref record; 82 of the 82 references it cites were found in a registry or an index.
The Comet Assay with Multiple Mouse Organs: Comparison of Comet Assay Results and Carcinogenicity with 208 Chemicals Selected from the IARC Monographs and U.S. NTP Carcinogenicity Database
Abstract
The comet assay is a microgel electrophoresis technique for detecting DNA damage at the level of the single cell. When this technique is applied to detect genotoxicity in experimental animals, the most important advantage is that DNA lesions can be measured in any organ, regardless of the extent of mitotic activity. The purpose of this article is to summarize the in vivo genotoxicity in eight organs of the mouse of 208 chemicals selected from International Agency for Research on Cancer (IARC) Groups 1, 2A, 2B, 3, and 4, and from the U.S. National Toxicology Program (NTP) Carcinogenicity Database, and to discuss the utility of the comet assay in genetic toxicology. Alkylating agents, amides, aromatic amines, azo compounds, cyclic nitro compounds, hydrazines, halides having reactive halogens, and polycyclic aromatic hydrocarbons were chemicals showing high positive effects in this assay. The responses detected reflected the ability of this assay to detect the fragmentation of DNA molecules produced by DNA single strand breaks induced chemically and those derived from alkali-labile sites developed from alkylated bases and bulky base adducts. The mouse or rat organs exhibiting increased levels of DNA damage were not necessarily the target organs for carcinogenicity. It was rare, in contrast, for the target organs not to show DNA damage. Therefore, organ-specific genotoxicity was necessary but not sufficient for the prediction of organ-specific carcinogenicity. It would be expected that DNA crosslinkers would be difficult to detect by this assay, because of the resulting inhibition of DNA unwinding. The proportion of 10 DNA crosslinkers that was positive, however, was high in the gastrointestinal mucosa, stomach, and colon, but less than 50% in the liver and lung. It was interesting that the genotoxicity of DNA crosslinkers could be detected in the gastrointestinal organs even though the agents were administered intraperitoneally. Chemical carcinogens can be classified as genotoxic (Ames test-positive) and putative nongenotoxic (Ames test-negative) carcinogens. The Ames test is generally used as a first screening method to assess chemical genotoxicity and has provided extensive information on DNA reactivity. Out of 208 chemicals studied, 117 are Ames test-positive rodent carcinogens, 43 are Ames test-negative rodent carcinogens, and 30 are rodent noncarcinogens (which include both Ames test-positive and negative noncarcinogens). High positive response ratio (110/117) for rodent genotoxic carcinogens and a high negative response ratio (6/30) for rodent noncarcinogens were shown in the comet assay. For Ames test-negative rodent carcinogens, less than 50% were positive in the comet assay, suggesting that the assay, which detects DNA lesions, is not suitable for identifying nongenotoxic carcinogens. In the safety evaluation of chemicals, it is important to demonstrate that Ames test-positive agents are not genotoxic in vivo. This assay had a high positive response ratio for rodent genotoxic carcinogens and a high negative response ratio for rodent genotoxic noncarcinogens, suggesting that the comet assay can be used to evaluate the in vivo genotoxicity of in vitro genotoxic chemicals. For chemicals whose in vivo genotoxicity has been tested in multiple organs by the comet assay, published data are summarized with unpublished data and compared with relevant genotoxicity and carcinogenicity data. Because it is clear that no single test is capable of detecting all relevant genotoxic agents, the usual approach should be to carry out a battery of in vitro and in vivo tests for genotoxicity. The conventional micronucleus test in the hematopoietic system is a simple method to assess in vivo clastogenicity of chemicals. Its performance is related to whether a chemical reaches the hematopoietic system. Among 208 chemicals studied (including 165 rodent carcinogens), 54 rodents carcinogens do not induce micronuclei in mouse hematopoietic system despite the positive finding with one or two in vitro tests. Forty-nine of 54 rodent carcinogens that do not induce micronuclei were positive in the comet assay, suggesting that the comet assay can be used as a further in vivo test apart from the cytogenetic assays in hematopoietic cells. In this review, we provide one recommendation for the in vivo comet assay protocol based on our own data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A simple technique for quantitation of low levels of DNA damage in individual cells
Singh, N. P., McCoy, M. T., Tice, R. R., & Schneider, E. L. (1988) · Experimental Cell Research · doi:10.1016/0014-4827(88)90265-0 · Cited by 10,828
Single cell gel/comet assay: Guidelines for in vitro and in vivo genetic toxicology testing
Tice, R. R., Agurell, E., Anderson, D., Burlinson, B., Hartmann, A., Kobayashi, H., Miyamae, Y., Rojas, E., Ryu, J.-C., & Sasaki, Y. F. (2000) · Environmental and Molecular Mutagenesis · doi:10.1002/(sici)1098-2280(2000)35:3<206::aid-em8>3.0.co;2-j · Cited by 4,860
Self-citationDetection of carcinogens as mutagens in the Salmonella/microsome test: assay of 300 chemicals.
McCann, J., Choi, E., Yamasaki, E., & Ames, B. N. (1975) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.72.12.5135 · Cited by 3,323
Bleyl, D. W. R. (1989) · Food / Nahrung · doi:10.1002/food.19890330516 · Cited by 2,305
The comet assay: a comprehensive review
Fairbairn, D. W., Olive, P. L., & O'Neill, K. L. (1995) · Mutation Research/Reviews in Genetic Toxicology · doi:10.1016/0165-1110(94)00013-3 · Cited by 1,664
Casarett and Doull's toxicology: The basic science of poisons
Pickrell, J. A. (1996) · Toxicology Letters · doi:10.1016/s0378-4274(96)90054-5 · Cited by 1,051
Detection of carcinogens as mutagens: bacterial tester strains with R factor plasmids.
McCann, J., Spingarn, N. E., Kobori, J., & Ames, B. N. (1975) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.72.3.979 · Cited by 1,016
McCann, J., & Ames, B. N. (1976) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.73.3.950 · Cited by 846
Primary mutagenicity screening of food additives currently used in Japan
Ishidate, M., Sofuni, T., Yoshikawa, K., Hayashi, M., Nohmi, T., Sawada, M., & Matsuoka, A. (1984) · Food and Chemical Toxicology · doi:10.1016/0278-6915(84)90271-0 · Cited by 817
Prediction of Chemical Carcinogenicity in Rodents from in Vitro Genetic Toxicity Assays
Tennant, R. W., Margolin, B. H., Shelby, M. D., Zeiger, E., Haseman, J. K., Spalding, J., Caspary, W., Resnick, M., Stasiewicz, S., Anderson, B., et al. (1987) · Science · doi:10.1126/science.3554512 · Cited by 811
Cited by
Single cell gel/comet assay: Guidelines for in vitro and in vivo genetic toxicology testing
Tice, R. R., Agurell, E., Anderson, D., Burlinson, B., Hartmann, A., Kobayashi, H., Miyamae, Y., Rojas, E., Ryu, J.-C., & Sasaki, Y. F. (2000) · Environmental and Molecular Mutagenesis · doi:10.1002/(sici)1098-2280(2000)35:3<206::aid-em8>3.0.co;2-j · Cited by 4,860
Self-citationRecommendations for conducting the in vivo alkaline Comet assay
Hartmann, A. (2003) · Mutagenesis · doi:10.1093/mutage/18.1.45 · Cited by 1,063
Fourth International Workgroup on Genotoxicity testing: Results of the in vivo Comet assay workgroup
Burlinson, B., Tice, R. R., Speit, G., Agurell, E., Brendler-Schwaab, S. Y., Collins, A. R., Escobar, P., Honma, M., Kumaravel, T. S., Nakajima, M., et al. (2007) · Mutation Research/Genetic Toxicology and Environmental Mutagenesis · doi:10.1016/j.mrgentox.2006.08.011 · Cited by 510
Self-citationEcotoxicological applications and significance of the comet assay
Jha, A. N. (2008) · Mutagenesis · doi:10.1093/mutage/gen014 · Cited by 477
Comet assay: a reliable tool for the assessment of DNA damage in different models
Dhawan, A., Bajpayee, M., & Parmar, D. (2009) · Cell Biology and Toxicology · doi:10.1007/s10565-008-9072-z · Cited by 387
Metadata
- Authors
- Sasaki, Y. F., Sekihashi, K., Izumiyama, F., Nishidate, E., Saga, A., Ishida, K., & Tsuda, S.
- Venue
- Critical Reviews in Toxicology
- Publisher
- Informa UK Limited
- Published
- 2000-01
- Volume
- 30
- Issue
- 6
- Pages
- 629-799
- ISSN
- 0045-6446 (ISSN-L)
- 1040-8444
- 1547-6898
- OpenAlex
- W2129016270
- Cited by
- 289
- References
- 82
- FWCI
- 2.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Comet Assay with Multiple Mouse Organs: Comparison of Comet Assay Results and Carcinogenicity with 208 Chemicals Selected from the IARC Monographs and U.S. NTP Carcinogenicity Database. https://app.cochat.ai/papers/10.1080/10408440008951123
- The paper
- Sasaki, Y. F., Sekihashi, K., Izumiyama, F., Nishidate, E., Saga, A., Ishida, K., & Tsuda, S. (2000). The Comet Assay with Multiple Mouse Organs: Comparison of Comet Assay Results and Carcinogenicity with 208 Chemicals Selected from the IARC Monographs and U.S. NTP Carcinogenicity Database. Critical Reviews in Toxicology. https://doi.org/10.1080/10408440008951123
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.