Indoor Particles: A Review
Open accessThe DOI matches its Crossref record.
Abstract
This paper reviews studies of particle concentrations and sources in homes and buildings. Three major studies of indoor and outdoor concentrations in U.S. homes are summarized in detail and compared. A number of smaller studies in homes are also briefly summarized. One study of 38 buildings and several smaller studies of buildings are also reviewed. All major studies found that an important indoor source of fine and coarse particles was cigarette smoking, with estimated increases in homes with smokers ranging from 25 to 45 µg/m3 PM2 5. Several studies identified cooking as a second important source. All of the three major studies found a substantial portion of indoor particles to be due to unexplained indoor sources, suggesting a topic for future research. One study also found a large unexplained increase in personal exposure to PM10 compared to concurrent indoor or outdoor concentrations—the so-called "personal cloud," a second topic for further research. The impact of outdoor air particles on indoor concentrations was considered. Equilibrium mass balance models indicate that this is a function of the penetration P through the building envelope, the air exchange rate a, and the particle decay rate k. EPA's PTEAM Study provided an estimate for k of 0.39 h 1 for fine particles and 1.01 h 1 for coarse particles. Two studies suggest that P = 1 for PM10. Using these results, the fraction of outdoor air PM2 s and PM10 particles found indoors at a given air exchange rate can be calculated. The protective effect of reducing air exchange rates during periods of high outdoor particle pollution can thus be quantified. Most studies showed poor correlations of personal exposures with outdoor concentrations. However, for those studies with seven or more repeated measurements, longitudinal regressions on exposures of individual subjects showed much improved correlations with outdoor particle concentrations. This new finding provides some support for the epidemiological findings of increased morbidity and mortality associated with higher outdoor particle concentrations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
KLEPEIS, N. E., NELSON, W. C., OTT, W. R., ROBINSON, J. P., TSANG, A. M., SWITZER, P., BEHAR, J. V., HERN, S. C., & ENGELMANN, W. H. (2001) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/sj.jea.7500165 · Cited by 4,803
Hoek, G., Brunekreef, B., Goldbohm, S., Fischer, P., & van den Brandt, P. A. (2002) · The Lancet · doi:10.1016/s0140-6736(02)11280-3 · Cited by 1,560
Jones, A. P. (1999) · Atmospheric Environment · doi:10.1016/s1352-2310(99)00272-1 · Cited by 1,481
Exposure measurement error in time-series studies of air pollution: concepts and consequences
Zeger, S. L., Thomas, D., Dominici, F., Samet, J. M., Schwartz, J., Dockery, D., & Cohen, A. (2000) · Environmental Health Perspectives · doi:10.1289/ehp.00108419 · Cited by 1,156
“values ( 21 ). Some have questioned whether the observed associations are plausible Measurement error in time-series studies”
BackgroundChen, C., & Zhao, B. (2011) · Atmospheric Environment · doi:10.1016/j.atmosenv.2010.09.048 · Cited by 972
Tran, V. V., Park, D., & Lee, Y.-C. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17082927 · Cited by 822
Metal-organic frameworks with photocatalytic bactericidal activity for integrated air cleaning
Li, P., Li, J., Feng, X., Li, J., Hao, Y., Zhang, J., Wang, H., Yin, A., Zhou, J., Ma, X., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-10218-9 · Cited by 802
MODELING INDOOR PARTICLE DEPOSITION FROM TURBULENT FLOW ONTO SMOOTH SURFACES
K. Lai, A. C., & Nazaroff, W. W. (2000) · Journal of Aerosol Science · doi:10.1016/s0021-8502(99)00536-4 · Cited by 696
Nazaroff, W. W. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00286.x · Cited by 639
Contribution from indoor sources to particle number and mass concentrations in residential houses
HE, C. (2004) · Atmospheric Environment · doi:10.1016/j.atmosenv.2004.03.027 · Cited by 585
Risk assessment of exposure to volatile organic compounds in different indoor environments
Guo, H., Lee, S. C., Chan, L. Y., & Li, W. M. (2004) · Environmental Research · doi:10.1016/s0013-9351(03)00035-5 · Cited by 529
Monn, C. (2001) · Atmospheric Environment · doi:10.1016/s1352-2310(00)00330-7 · Cited by 514
Medina-Ramón, M., Zanobetti, A., & Schwartz, J. (2006) · American Journal of Epidemiology · doi:10.1093/aje/kwj078 · Cited by 447
Long, C. M., Suh, H. H., Catalano, P. J., & Koutrakis, P. (2001) · Environmental Science & Technology · doi:10.1021/es001477d · Cited by 443
Indoor aerosols: from personal exposure to risk assessment
Morawska, L., Afshari, A., Bae, G. N., Buonanno, G., Chao, C. Y. H., Hänninen, O., Hofmann, W., Isaxon, C., Jayaratne, E. R., Pasanen, P., et al. (2013) · Indoor Air · doi:10.1111/ina.12044 · Cited by 442
Steinle, S., Reis, S., & Sabel, C. E. (2013) · Science of The Total Environment · doi:10.1016/j.scitotenv.2012.10.098 · Cited by 430
Woodruff, T. J., Grillo, J., & Schoendorf, K. C. (1997) · Environmental Health Perspectives · doi:10.1289/ehp.97105608 · Cited by 404
Kumar, P., Singh, A. B., Arora, T., Singh, S., & Singh, R. (2023) · Science of The Total Environment · doi:10.1016/j.scitotenv.2023.162163 · Cited by 380
Source Strengths for Indoor Human Activities that Resuspend Particulate Matter
Ferro, A. R., Kopperud, R. J., & Hildemann, L. M. (2004) · Environmental Science & Technology · doi:10.1021/es0263893 · Cited by 378
Jones, N. C., Thornton, C. A., Mark, D., & Harrison, R. M. (2000) · Atmospheric Environment · doi:10.1016/s1352-2310(99)00489-6 · Cited by 374
Morawska, L., Ayoko, G. A., Bae, G. N., Buonanno, G., Chao, C. Y. H., Clifford, S., Fu, S. C., Hänninen, O., He, C., Isaxon, C., et al. (2017) · Environment International · doi:10.1016/j.envint.2017.07.025 · Cited by 374
A GIS–Environmental Justice Analysis of Particulate Air Pollution in Hamilton, Canada
Jerrett, M., Burnett, R. T., Kanaroglou, P., Eyles, J., Finkelstein, N., Giovis, C., & Brook, J. R. (2001) · Environment and Planning A: Economy and Space · doi:10.1068/a33137 · Cited by 362
Characterization of indoor particle sources: A study conducted in the metropolitan Boston area.
Abt, E., Suh, H. H., Allen, G., & Koutrakis, P. (2000) · Environmental Health Perspectives · doi:10.1289/ehp.0010835 · Cited by 332
Molecular epidemiologic research on the effects of environmental pollutants on the fetus.
Perera, F. P., Jedrychowski, W., Rauh, V, & Whyatt, R. M. (1999) · Environmental Health Perspectives · doi:10.1289/ehp.99107s3451 · Cited by 316
Source Strengths of Ultrafine and Fine Particles Due to Cooking with a Gas Stove
Wallace, L. A., Emmerich, S. J., & Howard-Reed, C. (2004) · Environmental Science & Technology · doi:10.1021/es0306260 · Cited by 290
Self-citationBurnett, R. T., Cakmak, S., Brook, J. R., & Krewski, D. (1997) · Environmental Health Perspectives · doi:10.1289/ehp.97105614 · Cited by 287
Dominici, F., Samet, J. M., & Zeger, S. L. (2000) · Journal of the Royal Statistical Society Series A: Statistics in Society · doi:10.1111/1467-985x.00170 · Cited by 286
“When the target is an estimation of the health effects of personal exposure to a pollutant, error is well recognized to be a potential source of bias (Lioy et al., 1990; Mage and Buckley, 1995; Wallace, 1996; Ozkaynak et al., 1996; Janssen et al., 1997, 1998).”
BackgroundFischer, P. H., Hoek, G., van Reeuwijk, H., Briggs, D. J., Lebret, E., van Wijnen, J. H., Kingham, S., & Elliott, P. E. (2000) · Atmospheric Environment · doi:10.1016/s1352-2310(00)00067-4 · Cited by 277
Ozone and limonene in indoor air: a source of submicron particle exposure.
Wainman, T., Zhang, J., Weschler, C. J., & Lioy, P. J. (2000) · Environmental Health Perspectives · doi:10.1289/ehp.001081139 · Cited by 274
Modeling particle dispersion and deposition in indoor environments
Gao, N. P., & Niu, J. L. (2007) · Atmospheric Environment · doi:10.1016/j.atmosenv.2007.01.016 · Cited by 273
Meng, Q. Y., Turpin, B. J., Korn, L., Weisel, C. P., Morandi, M., Colome, S., Zhang, J., Stock, T., Spektor, D., Winer, A., et al. (2005) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/sj.jea.7500378 · Cited by 266
Janssen, N. A. H., Hoek, G., Brunekreef, B., Harssema, H., Menswik, I., & Zuidhof, A. (1998) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a009485 · Cited by 258
Investigation of indoor air quality at residential homes in Hong Kong—case study
Lee, S. C., Li, W.-M., & Ao, C.-H. (2002) · Atmospheric Environment · doi:10.1016/s1352-2310(01)00435-6 · Cited by 254
Ko, F. W. S., Tam, W., Wong, T. W., Chan, D. P. S., Tung, A. H., Lai, C. K. W., & Hui, D. S. C. (2007) · Thorax · doi:10.1136/thx.2006.076166 · Cited by 253
Braniš, M., Řezáčová, P., & Domasová, M. (2005) · Environmental Research · doi:10.1016/j.envres.2004.12.001 · Cited by 249
Current State of the Science: Health Effects and Indoor Environmental Quality
Mitchell, C. S., Zhang, J. (., Sigsgaard, T., Jantunen, M., Lioy, P. J., Samson, R., & Karol, M. H. (2007) · Environmental Health Perspectives · doi:10.1289/ehp.8987 · Cited by 245
“5 could not be explained with known sources (Wallace 1996).”
BackgroundSources, health effects and control strategies of indoor fine particulate matter (PM2.5): A review
Li, Z., Wen, Q., & Zhang, R. (2017) · Science of The Total Environment · doi:10.1016/j.scitotenv.2017.02.029 · Cited by 236
Indoor Air Pollution and Asthma in Children
Breysse, P. N., Diette, G. B., Matsui, E. C., Butz, A. M., Hansel, N. N., & McCormack, M. C. (2010) · Proceedings of the American Thoracic Society · doi:10.1513/pats.200908-083rm · Cited by 228
Personal Exposure to Polybrominated Diphenyl Ethers (PBDEs) in Residential Indoor Air
Allen, J. G., McClean, M. D., Stapleton, H. M., Nelson, J. W., & Webster, T. F. (2007) · Environmental Science & Technology · doi:10.1021/es0703170 · Cited by 227
Janssen, N. A. H., Schwartz, J., Zanobetti, A., & Suh, H. H. (2002) · Environmental Health Perspectives · doi:10.1289/ehp.0211043 · Cited by 226
“Consistent with these findings, previous studies have also shown that personal and/or indoor concentrations of sulfate are lower and less well correlated with outdoor concentrations for homes with air conditioning (AC) than homes without AC (7,8), likely because air conditioned homes typically have lower air exchange…”
ResultA population exposure model for particulate matter: case study results for PM2.5 in Philadelphia, PA
BURKE, J. M., ZUFALL, M. J., & ÖZKAYNAK, H. (2001) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/sj.jea.7500188 · Cited by 223
Residential indoor PM10 and PM2.5 in Hong Kong and the elemental composition
Chao, C. Y., & Wong, K. K. (2002) · Atmospheric Environment · doi:10.1016/s1352-2310(01)00411-3 · Cited by 218
Development and evaluation of a personal cascade impactor sampler (PCIS)
Misra, C., Singh, M., Shen, S., Sioutas, C., & Hall, P. M. (2002) · Journal of Aerosol Science · doi:10.1016/s0021-8502(02)00055-1 · Cited by 216
Polycyclic Aromatic Hydrocarbons in the Indoor and Outdoor Air of Three Cities in the U.S.
Naumova, Y. Y., Eisenreich, S. J., Turpin, B. J., Weisel, C. P., Morandi, M. T., Colome, S. D., Totten, L. A., Stock, T. H., Winer, A. M., Alimokhtari, S., et al. (2002) · Environmental Science & Technology · doi:10.1021/es015727h · Cited by 215
Home environmental intervention in inner-city asthma: a randomized controlled clinical trial
Eggleston, P. A., Butz, A., Rand, C., Curtin-Brosnan, J., Kanchanaraksa, S., Swartz, L., Breysse, P., Buckley, T., Diette, G., Merriman, B., et al. (2005) · Annals of Allergy, Asthma & Immunology · doi:10.1016/s1081-1206(10)61012-5 · Cited by 213
Quantifying the Routes of Transmission for Pandemic Influenza
Atkinson, M. P., & Wein, L. M. (2008) · Bulletin of Mathematical Biology · doi:10.1007/s11538-007-9281-2 · Cited by 213
Allen, R., Larson, T., Sheppard, L., Wallace, L., & Liu, L.-J. S. (2003) · Environmental Science & Technology · doi:10.1021/es021007e · Cited by 205
Self-citationExposure to Ambient and Nonambient Components of Particulate Matter: A Comparison of Health Effects
Ebelt, S. T., Wilson, W. E., & Brauer, M. (2005) · Epidemiology · doi:10.1097/01.ede.0000158918.57071.3e · Cited by 196
Particle deposition rates in residential houses
He, C., Morawska, L., & Gilbert, D. (2005) · Atmospheric Environment · doi:10.1016/j.atmosenv.2005.03.016 · Cited by 189
“The penetration efficiency is commonly assumed to be close to one for both fine and coarse particles (Wallace 1996).”
BackgroundInfluentialExposure assessment of particulate matter for susceptible populations in Seattle.
Liu, L.-J. S., Box, M., Kalman, D., Kaufman, J., Koenig, J., Larson, T., Lumley, T., Sheppard, L., & Wallace, L. (2003) · Environmental Health Perspectives · doi:10.1289/ehp.6011 · Cited by 188
“Outdoor sulfur or sulfate, which is predominantly in fine particles and of outdoor origin, was highly correlated with personal sulfur or sulfate exposures (Brauer et al. 1999; Ebelt et al. 2000; Özkaynak et al. 1996; Stieb et al. 1998; Suh et al. 1992; Wallace 1996).”
BackgroundSelf-citationBlocken, B., van Druenen, T., Ricci, A., Kang, L., van Hooff, T., Qin, P., Xia, L., Ruiz, C. A., Arts, J. H., Diepens, J. F. L., et al. (2021) · Building and Environment · doi:10.1016/j.buildenv.2021.107659 · Cited by 183
Wichmann, J., Lind, T., Nilsson, M. A.-M., & Bellander, T. (2010) · Atmospheric Environment · doi:10.1016/j.atmosenv.2010.08.023 · Cited by 182
Elevated personal exposure to particulate matter from human activities in a residence
Ferro, A. R., Kopperud, R. J., & Hildemann, L. M. (2004) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/sj.jea.7500356 · Cited by 174
“A summary of major indoor/outdoor concentration studies has shown that cigarette smoking and cooking are the largest identified sources of indoor air particles, while cleaning activities were identified as a contributor to indoor PM of unknown significance (Wallace, 1996).”
BackgroundEstimating the concentration of indoor particles of outdoor origin: A review
Diapouli, E., Chaloulakou, A., & Koutrakis, P. (2013) · Journal of the Air & Waste Management Association · doi:10.1080/10962247.2013.791649 · Cited by 173
“39 hr (1)) based on previous studies (Ozkaynak et al., 1996; Wallace, 1996), in order to calculate the air exchange rate for each residence:”
BackgroundMethodInfluentialVilleneuve, P. J., Chen, L., Stieb, D., & Rowe, B. H. (2006) · European Journal of Epidemiology · doi:10.1007/s10654-006-9050-9 · Cited by 173
“Namely, outdoor particles consist of coarse dust and finer fractions of sulfates and carbon particles generated from internal combustion engines, whereas indoor air particles are generated from cigarette smoking, radon, indoor combustion of fuels, molds, fungi, and indoor activities [33, 34].”
BackgroundWei See, S., Karthikeyan, S., & Balasubramanian, R. (2006) · Journal of Environmental Monitoring · doi:10.1039/b516173h · Cited by 169
Hydroxyl radicals in indoor environments
Sarwar, G., Corsi, R., Kimura, Y., Allen, D., & Weschler, C. J. (2002) · Atmospheric Environment · doi:10.1016/s1352-2310(02)00278-9 · Cited by 167
Residence close to high traffic and prevalence of coronary heart disease
Hoffmann, B., Moebus, S., Stang, A., Beck, E.-M., Dragano, N., Mohlenkamp, S., Schmermund, A., Memmesheimer, M., Mann, K., Erbel, R., et al. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl278 · Cited by 161
Sources of indoor air pollution in New York City residences of asthmatic children
Habre, R., Coull, B., Moshier, E., Godbold, J., Grunin, A., Nath, A., Castro, W., Schachter, N., Rohr, A., Kattan, M., et al. (2014) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/jes.2013.74 · Cited by 158
Ji, W., & Zhao, B. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.04.006 · Cited by 158
The transformation of outdoor ammonium nitrate aerosols in the indoor environment
Lunden, M. M., Revzan, K. L., Fischer, M. L., Thatcher, T. L., Littlejohn, D., Hering, S. V., & Brown, N. J. (2003) · Atmospheric Environment · doi:10.1016/j.atmosenv.2003.09.035 · Cited by 152
“Many investigators have examined the indoor concentrations of particulate mass and gaseous species, including their transport into and out of buildings, emissions and formation indoors, and interactions between pollutants and the building surfaces and air handling equipment ( Wallace, 1996; Weschler, 2000).”
BackgroundCummings, B. E., & Waring, M. S. (2020) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/s41370-019-0175-9 · Cited by 98
Molnár, P., Bellander, T., Sällsten, G., & Boman, J. (2007) · J. Environ. Monit. · doi:10.1039/b616858b · Cited by 83
Fazli, T., & Stephens, B. (2018) · Building and Environment · doi:10.1016/j.buildenv.2018.03.047 · Cited by 35
“Particles are generated indoors by smoking [9], cooking [39], burning incense and candles [40,41], operating office equipment and other appliances [42], and by resuspension from settled dust [43,44].”
Background
Metadata
- Authors
- Wallace, L.
- Venue
- Journal of the Air & Waste Management Association
- Publisher
- Informa UK Limited
- Published
- 1996-02
- Volume
- 46
- Issue
- 2
- Pages
- 98-126
- ISSN
- 1047-3289 (ISSN-L)
- 1096-2247
- 2162-2906
- OpenAlex
- W1973809191
- Cited by
- 698
- References
- 0
- FWCI
- 14.38
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.