Lymph Flow, Shear Stress, and Lymphocyte Velocity in Rat Mesenteric Prenodal Lymphatics
The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
Objective: To measure lymphocyte velocity, lymphatic contraction, and shear stress in phasically contracting lymphatics in situ. Methods: A high‐speed video system was used to capture multiple contraction cycles in rat mesenteric lymphatic preparations. The images were analyzed to determine fluid velocity, volume flow rate, wall shear stress, and retrograde flow. Results: Lymphocyte density and flux varied from 326 to 35,500 cells/μ L and 206 to 2030 cells/min, respectively. Lymphatics contracted phasically, with a mean diameter 91 ± 9.0 μ m and amplitudes of 39%. Lymph velocity varied with the phasic contractions in both direction and magnitude with an average of 0.87 ± 0.18 and peaks of 2.2–9.0 mm/s. The velocity was ∼ 180° out of phase with the contraction cycle. The average lymph flow was 13.95 ± 5.27 μ L/h with transient periods of flow reversal. This resulted in an average shear of 0.64 ± 0.14 with peaks of 4–12 dynes/cm 2. Conclusions: High‐speed lymphocyte tracking provided the spatial and temporal resolution to measure lymphocyte flux throughout the phasic contraction. Poiseuille flow was a reasonable model for estimating wall shear stress through most of the phasic contraction cycle of the intervalvular lymphatic segments. Shear rate was low but had large variations in magnitude compared to that seen in blood vessels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Textbook of Medical Physiology
(1966) · Annals of Internal Medicine · doi:10.7326/0003-4819-64-6-1363_2 · Cited by 9,749
Flow-mediated endothelial mechanotransduction
Davies, P. F. (1995) · Physiological Reviews · doi:10.1152/physrev.1995.75.3.519 · Cited by 2,802
Introduction to fluid mechanics
(2013) · Engineering Science · doi:10.4324/9780203114964-25 · Cited by 1,957
Textbook of Medical Physiology
Iatridis, P. G. (1991) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1991.03470200123049 · Cited by 1,275
Microlymphatics and lymph flow
Schmid-Schonbein, G. W. (1990) · Physiological Reviews · doi:10.1152/physrev.1990.70.4.987 · Cited by 613
Shear stress-induced release of nitric oxide from endothelial cells grown on beads.
Buga, G. M., Gold, M. E., Fukuto, J. M., & Ignarro, L. J. (1991) · Hypertension · doi:10.1161/01.hyp.17.2.187 · Cited by 484
Microvascular Rheology and Hemodynamics
LIPOWSKY, H. H. (2005) · Microcirculation · doi:10.1080/10739680590894966 · Cited by 414
Introduction to Fluid Mechanics
(1998) · Elsevier eBooks · doi:10.1016/b978-0-340-67649-3.x5000-3 · Cited by 315
Malek, A. M., Gibbons, G. H., Dzau, V. J., & Izumo, S. (1993) · Journal of Clinical Investigation · doi:10.1172/jci116796 · Cited by 298
Inhibition of the active lymph pump by flow in rat mesenteric lymphatics and thoracic duct
Gashev, A. A., Davis, M. J., & Zawieja, D. C. (2002) · The Journal of Physiology · doi:10.1113/jphysiol.2001.016642 · Cited by 282
Self-citation
Cited by
Wiig, H., & Swartz, M. A. (2012) · Physiological Reviews · doi:10.1152/physrev.00037.2011 · Cited by 722
Interstitial Flow and Its Effects in Soft Tissues
Swartz, M. A., & Fleury, M. E. (2007) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.9.060906.151850 · Cited by 598
Rasmussen, M. K., Mestre, H., & Nedergaard, M. (2022) · Physiological Reviews · doi:10.1152/physrev.00031.2020 · Cited by 597
Fluids and their mechanics in tumour transit: shaping metastasis
Follain, G., Herrmann, D., Harlepp, S., Hyenne, V., Osmani, N., Warren, S. C., Timpson, P., & Goetz, J. G. (2020) · Nature Reviews Cancer · doi:10.1038/s41568-019-0221-x · Cited by 412
Sabine, A., Agalarov, Y., Maby-El Hajjami, H., Jaquet, M., Hägerling, R., Pollmann, C., Bebber, D., Pfenniger, A., Miura, N., Dormond, O., et al. (2012) · Developmental Cell · doi:10.1016/j.devcel.2011.12.020 · Cited by 411
Contractile Physiology of Lymphatics
Zawieja, D. C. (2009) · Lymphatic Research and Biology · doi:10.1089/lrb.2009.0007 · Cited by 368
Self-citationChronic stress in mice remodels lymph vasculature to promote tumour cell dissemination
Le, C. P., Nowell, C. J., Kim-Fuchs, C., Botteri, E., Hiller, J. G., Ismail, H., Pimentel, M. A., Chai, M. G., Karnezis, T., Rotmensz, N., et al. (2016) · Nature Communications · doi:10.1038/ncomms10634 · Cited by 354
Lymphatic Vessel Network Structure and Physiology
Breslin, J. W., Yang, Y., Scallan, J. P., Sweat, R. S., Adderley, S. P., & Murfee, W. L. (2018) · Comprehensive Physiology · doi:10.1002/cphy.c180015 · Cited by 341
Moore, J. E., & Bertram, C. D. (2018) · Annual Review of Fluid Mechanics · doi:10.1146/annurev-fluid-122316-045259 · Cited by 340
Self-citationVascular remodeling is governed by a VEGFR3-dependent fluid shear stress set point
Baeyens, N., Nicoli, S., Coon, B. G., Ross, T. D., Van den Dries, K., Han, J., Lauridsen, H. M., Mejean, C. O., Eichmann, A., Thomas, J.-L., et al. (2015) · eLife · doi:10.7554/elife.04645 · Cited by 265
Determinants of valve gating in collecting lymphatic vessels from rat mesentery
Davis, M. J., Rahbar, E., Gashev, A. A., Zawieja, D. C., & Moore, J. E. (2011) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00133.2011 · Cited by 179
“Although centerline velocity can be measured using red blood cells introduced into the input pipette (see Supplemental Video S4), velocity during much of systole is often too high (15, 16) to be accurately determined at 30 frames per second with the camera used in the present experiments.”
MethodSelf-citationLymph flow regulates collecting lymphatic vessel maturation in vivo
Sweet, D. T., Jiménez, J. M., Chang, J., Hess, P. R., Mericko-Ishizuka, P., Fu, J., Xia, L., Davies, P. F., & Kahn, M. L. (2015) · Journal of Clinical Investigation · doi:10.1172/jci79386 · Cited by 174
“The fluid shear force experienced by arterial ECs is approximately 75 times greater than that experienced by LECs in large lymphatic vessels (15), and forces in the developing lymphatic vasculature may be even lower.”
InfluentialThe Importance of Mechanical Forces for in vitro Endothelial Cell Biology
Gordon, E., Schimmel, L., & Frye, M. (2020) · Frontiers in Physiology · doi:10.3389/fphys.2020.00684 · Cited by 171
Sato, M., Sasaki, N., Ato, M., Hirakawa, S., Sato, K., & Sato, K. (2015) · PLOS ONE · doi:10.1371/journal.pone.0137301 · Cited by 124
“In experiments conducted using small animals, blood and lymph flows were measured by observing the movements of erythrocytes and leukocytes in the vessels [4].”
MethodScallan, J. P., Wolpers, J. H., Muthuchamy, M., Zawieja, D. C., Gashev, A. A., & Davis, M. J. (2012) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01098.2011 · Cited by 79
Self-citation
Metadata
- Authors
- DIXON, J. B., GREINER, S. T., GASHEV, A. A., COTE, G. L., MOORE, J. E., & ZAWIEJA, D. C.
- Venue
- Microcirculation
- Publisher
- Wiley
- Published
- 2006-10-11
- Volume
- 13
- Issue
- 7
- Pages
- 597-610
- ISSN
- 1073-9688 (ISSN-L)
- 1549-8719
- OpenAlex
- W2118722193
- Cited by
- 267
- References
- 32
- FWCI
- 2.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.