Lymph Flow, Shear Stress, and Lymphocyte Velocity in Rat Mesenteric Prenodal Lymphatics
The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
Objective: To measure lymphocyte velocity, lymphatic contraction, and shear stress in phasically contracting lymphatics in situ. Methods: A high‐speed video system was used to capture multiple contraction cycles in rat mesenteric lymphatic preparations. The images were analyzed to determine fluid velocity, volume flow rate, wall shear stress, and retrograde flow. Results: Lymphocyte density and flux varied from 326 to 35,500 cells/μ L and 206 to 2030 cells/min, respectively. Lymphatics contracted phasically, with a mean diameter 91 ± 9.0 μ m and amplitudes of 39%. Lymph velocity varied with the phasic contractions in both direction and magnitude with an average of 0.87 ± 0.18 and peaks of 2.2–9.0 mm/s. The velocity was ∼ 180° out of phase with the contraction cycle. The average lymph flow was 13.95 ± 5.27 μ L/h with transient periods of flow reversal. This resulted in an average shear of 0.64 ± 0.14 with peaks of 4–12 dynes/cm 2. Conclusions: High‐speed lymphocyte tracking provided the spatial and temporal resolution to measure lymphocyte flux throughout the phasic contraction. Poiseuille flow was a reasonable model for estimating wall shear stress through most of the phasic contraction cycle of the intervalvular lymphatic segments. Shear rate was low but had large variations in magnitude compared to that seen in blood vessels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Textbook of Medical Physiology
(1966) · Annals of Internal Medicine · doi:10.7326/0003-4819-64-6-1363_2 · Cited by 9,749
Flow-mediated endothelial mechanotransduction
Davies, P. F. (1995) · Physiological Reviews · doi:10.1152/physrev.1995.75.3.519 · Cited by 2,802
Introduction to fluid mechanics
(2013) · Engineering Science · doi:10.4324/9780203114964-25 · Cited by 1,957
Textbook of Medical Physiology
Iatridis, P. G. (1991) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1991.03470200123049 · Cited by 1,275
Microlymphatics and lymph flow
Schmid-Schonbein, G. W. (1990) · Physiological Reviews · doi:10.1152/physrev.1990.70.4.987 · Cited by 613
Shear stress-induced release of nitric oxide from endothelial cells grown on beads.
Buga, G. M., Gold, M. E., Fukuto, J. M., & Ignarro, L. J. (1991) · Hypertension · doi:10.1161/01.hyp.17.2.187 · Cited by 484
Microvascular Rheology and Hemodynamics
LIPOWSKY, H. H. (2005) · Microcirculation · doi:10.1080/10739680590894966 · Cited by 414
Introduction to Fluid Mechanics
(1998) · Elsevier eBooks · doi:10.1016/b978-0-340-67649-3.x5000-3 · Cited by 315
Malek, A. M., Gibbons, G. H., Dzau, V. J., & Izumo, S. (1993) · Journal of Clinical Investigation · doi:10.1172/jci116796 · Cited by 298
Inhibition of the active lymph pump by flow in rat mesenteric lymphatics and thoracic duct
Gashev, A. A., Davis, M. J., & Zawieja, D. C. (2002) · The Journal of Physiology · doi:10.1113/jphysiol.2001.016642 · Cited by 282
Self-citationThe effect of transmural pressure on pumping activity in isolated bovine lymphatic vessels.
McHale, N. G., & Roddie, I. C. (1976) · The Journal of Physiology · doi:10.1113/jphysiol.1976.sp011557 · Cited by 245
Benoit, J. N., Zawieja, D. C., Goodman, A. H., & Granger, H. J. (1989) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1989.257.6.h2059 · Cited by 229
Self-citationMolecular and functional analyses of the contractile apparatus in lymphatic muscle
Muthuchamy, M., Gashev, A., Boswell, N., Dawson, N., & Zawieja, D. (2003) · The FASEB Journal · doi:10.1096/fj.02-0626fje · Cited by 205
Self-citationIntrinsic contractility of prenodal lymph vessels and lymph flow in human leg
Olszewski, W. L., & Engeset, A. (1980) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1980.239.6.h775 · Cited by 201
Regional Variations of Contractile Activity in Isolated Rat Lymphatics
GASHEV, A. A., DAVIS, M. J., DELP, M. D., & ZAWIEJA, D. C. (2004) · Microcirculation · doi:10.1080/10739680490476033 · Cited by 192
Self-citationDistribution, propagation, and coordination of contractile activity in lymphatics
Zawieja, D. C., Davis, K. L., Schuster, R., Hinds, W. M., & Granger, H. J. (1993) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1993.264.4.h1283 · Cited by 188
Self-citationAdvances in Imaging of Lymph Flow Disorders
Witte, C. L., Witte, M. H., Unger, E. C., Williams, W. H., Bernas, M. J., McNeill, G. C., & Stazzone, A. M. (2000) · RadioGraphics · doi:10.1148/radiographics.20.6.g00nv141697 · Cited by 161
Structural response of growing bone to exercise and disuse
Biewener, A. A., & Bertram, J. E. A. (1994) · Journal of Applied Physiology · doi:10.1152/jappl.1994.76.2.946 · Cited by 155
Swartz, M. A., Berk, D. A., & Jain, R. K. (1996) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1996.270.1.h324 · Cited by 140
Contractile stimuli in collecting lymph vessels
Hargens, A. R., & Zweifach, B. W. (1977) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1977.233.1.h57 · Cited by 126
Regulation of the vasomotor activity of lymph microvessels by nitric oxide and prostaglandins
Mizuno, R., Koller, A., & Kaley, G. (1998) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.1998.274.3.r790 · Cited by 117
Lymph flow dynamics in exercising human skeletal muscle as detected by scintography
Havas, E., Parviainen, T., Vuorela, J., Toivanen, J., Nikula, T., & Vihko, V. (1997) · The Journal of Physiology · doi:10.1111/j.1469-7793.1997.233bf.x · Cited by 113
Nitric oxide decreases pacemaker activity in lymphatic vessels of guinea pig mesentery
von der Weid, P.-Y., Zhao, J., & Van Helden, D. F. (2001) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.2001.280.6.h2707 · Cited by 111 · cited 1×
“One of the factors shown to reduce the spontaneous transient depolarizations of the pacemaker activity in the lymph vessels is nitric oxide [22, 31, 39, 42].”
BackgroundPhysiological roles of endogenous nitric oxide in lymphatic pump activity of rat mesentery in vivo
Shirasawa, Y., Ikomi, F., & Ohhashi, T. (2000) · American Journal of Physiology-Gastrointestinal and Liver Physiology · doi:10.1152/ajpgi.2000.278.4.g551 · Cited by 103
Berk, D. A., Swartz, M. A., Leu, A. J., & Jain, R. K. (1996) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1996.270.1.h330 · Cited by 87
Flow velocity of single lymphatic capillaries in human skin
Fischer, M., Franzeck, U. K., Herrig, I., Costanzo, U., Wen, S., Schiesser, M., Hoffmann, U., & Bollinger, A. (1996) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1996.270.1.h358 · Cited by 78
Measuring microlymphatic flow using fast video microscopy
Dixon, J. B., Zawieja, D. C., Gashev, A. A., & Coté, G. L. (2005) · Journal of Biomedical Optics · doi:10.1117/1.2135791 · Cited by 75
Self-citationKoller, A., Mizuno, R., & Kaley, G. (1999) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.1999.277.6.r1683 · Cited by 73
Inhibition of active lymph pump by simulated microgravity in rats
Gashev, A. A., Delp, M. D., & Zawieja, D. C. (2006) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00260.2005 · Cited by 60
Self-citationIncreased lymphocyte transport by lipid absorption in rat mesenteric lymphatics
Miura, S., Sekizuka, E., Nagata, H., Oshio, C., Minamitani, H., Suematsu, M., Suzuki, M., Hamada, Y., Kobayashi, K., Asakura, H., et al. (1987) · American Journal of Physiology-Gastrointestinal and Liver Physiology · doi:10.1152/ajpgi.1987.253.5.g596 · Cited by 42
Effects of endothelin on spontaneous contractions in lymph vessels
Sakai, H., Ikomi, F., & Ohhashi, T. (1999) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1999.277.2.h459 · Cited by 24
[Pumping function of lymphangion depending on various hydrostatic gradients].
Gashev, A. A. (1989) · PubMed · Cited by 7
Self-citation
Cited by
Wiig, H., & Swartz, M. A. (2012) · Physiological Reviews · doi:10.1152/physrev.00037.2011 · Cited by 722
Interstitial Flow and Its Effects in Soft Tissues
Swartz, M. A., & Fleury, M. E. (2007) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.9.060906.151850 · Cited by 598
Rasmussen, M. K., Mestre, H., & Nedergaard, M. (2022) · Physiological Reviews · doi:10.1152/physrev.00031.2020 · Cited by 597
Fluids and their mechanics in tumour transit: shaping metastasis
Follain, G., Herrmann, D., Harlepp, S., Hyenne, V., Osmani, N., Warren, S. C., Timpson, P., & Goetz, J. G. (2020) · Nature Reviews Cancer · doi:10.1038/s41568-019-0221-x · Cited by 412
Sabine, A., Agalarov, Y., Maby-El Hajjami, H., Jaquet, M., Hägerling, R., Pollmann, C., Bebber, D., Pfenniger, A., Miura, N., Dormond, O., et al. (2012) · Developmental Cell · doi:10.1016/j.devcel.2011.12.020 · Cited by 411
Metadata
- Authors
- DIXON, J. B., GREINER, S. T., GASHEV, A. A., COTE, G. L., MOORE, J. E., & ZAWIEJA, D. C.
- Venue
- Microcirculation
- Publisher
- Wiley
- Published
- 2006-10-11
- Volume
- 13
- Issue
- 7
- Pages
- 597-610
- ISSN
- 1073-9688 (ISSN-L)
- 1549-8719
- OpenAlex
- W2118722193
- Cited by
- 267
- References
- 32
- FWCI
- 2.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.