A New Sensitive Radioimmunoassay for Plasma Arginine Vasopressin
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A new extremely sensitive radioimmunoassay to measure plasma AVP has been developed. Antiserum to AVP of high affinity (Keq = 1.1 X 10(12) 1/mol), raised in rabbits, showed little cross-reaction with related analogues (LVP less than 0.03%, AVT, DDAVP, OXT less than 0.01). The specific activity of 125I-AVP (chloramine T method) was 1400-1750 Ci/mmol. The limit of detection of plasma AVP, after extraction of 2 ml plasma with Florisil, was 0.3 pmol/1. Coefficient of variations of plasma control (2 pmo1/1) were 9.7% (intraassay) and 15.3% (inter-assay), n = 15. Osmotic stimulation by hypertonic saline infusion caused a linear response in plasma AVP in normal subjects, but plasma AVP remained undetectable in patients with cranial diabetes insipidus. Suppression of AVP secretion by a standard oral water load and by alcohol and fluid in volunteers produced low or undetectable values of plasma AVP. In a patient with the syndrome of inappropriate antidiuresis, plasma AVP concentration was grossly elevated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Robertson, G. L., Mahr, E. A., Athar, S., & Sinha, T. (1973) · Journal of Clinical Investigation · doi:10.1172/jci107423 · Cited by 787
THE DEVELOPMENT OF A RADIOIMMUNOASSAY FOR THE MEASUREMENT OF HUMAN PLASMA ARGININE VASOPRESSIN
BAYLIS, P. H., & HEATH, D. A. (1977) · Clinical Endocrinology · doi:10.1111/j.1365-2265.1977.tb01300.x · Cited by 51
Self-citation
Cited by
Diurnal variation in the levels of antidiuretic hormone in the elderly
ASPLUND, R., & ÅBERG, H. (1991) · Journal of Internal Medicine · doi:10.1111/j.1365-2796.1991.tb00320.x · Cited by 246
Ryan, M. C. M., Sharifi, N., Condren, R., & Thakore, J. H. (2004) · Psychoneuroendocrinology · doi:10.1016/j.psyneuen.2003.08.011 · Cited by 225
“(Rooke and Baylis, 1982).”
The osmotic thresholds for thirst and vasopressin release are similar in healthy man
Thompson, C. J., Bland, J., Burd, J., & Baylis, P. H. (1986) · Clinical Science · doi:10.1042/cs0710651 · Cited by 168
Self-citationDiagnosis and Management of Central Diabetes Insipidus in Adults
Tomkins, M., Lawless, S., Martin-Grace, J., Sherlock, M., & Thompson, C. J. (2022) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgac381 · Cited by 159
Sexual Dimorphism in the Posterior Pituitary Response to Stress in the Rat*
WILLIAMS, T. D. M., CARTER, D. A., & LIGHTMAN, S. L. (1985) · Endocrinology · doi:10.1210/endo-116-2-738 · Cited by 128
Metadata
- Authors
- Rooke, P., & Baylis, P. H.
- Venue
- Journal of Immunoassay
- Publisher
- Informa UK Limited
- Published
- 1982-01
- Volume
- 3
- Issue
- 2
- Pages
- 115-131
- ISSN
- 0197-1522 (ISSN-L)
- OpenAlex
- W1997633506
- Cited by
- 112
- References
- 2
- FWCI
- 7.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.