Performance of N95 Respirators: Filtration Efficiency for Airborne Microbial and Inert Particles
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
In 1995 the National Institute for Occupational Safety and Health issued new regulations for nonpowered particulate respirators (42 CFR Part 84). A new filter certification system also was created. Among the new particulate respirators that have entered the market, the N95 respirator is the most commonly used in industrial and health care environments. The filtration efficiencies of unloaded N95 particulate respirators have been compared with those of dust/mist (DM) and dust/fume/mist (DFM) respirators certified under the former regulations (30 CFR Part 11). Through laboratory tests with NaCl certification aerosols and measurements with particle-size spectrometers, N95 respirators were found to have higher filtration efficiencies than DM and DFM respirators and noncertified surgical masks. N95 respirators made by different companies were found to have different filtration efficiencies for the most penetrating particle size (0.1 to 0.3 micron), but all were at least 95% efficient at that size for NaCl particles. Above the most penetrating particle size the filtration efficiency increases with size; it reaches approximately 99.5% or higher at about 0.75 micron. Tests with bacteria of size and shape similar to Mycobacterium tuberculosis also showed filtration efficiencies of 99.5% or higher. Experimental data were used to calculate the aerosol mass concentrations inside the respirator when worn in representative work environments. The penetrated mass fractions, in the absence of face leakage, ranged from 0.02% for large particle distributions to 1.8% for submicrometer-size welding fumes. Thus, N95 respirators provide excellent protection against airborne particles when there is a good face seal.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Inward leakage due to gaps in the fit has been demonstrated to play a critical role in the ability of a mask or respirator to protect against exposure to particulates [4, 59, 82–84].”
From The protective performance of reusable cloth face masks, disposable procedure masks, KN95 masks and N95 respirators: Filtration and total inward leakage (2021) · cites this paper as [83]
In the citing paper
“They have at least 95% filtration efficiency for NaCl particles sized 0.1 to 0.3 𝜇 m with even higher filtration efficiency at higher particle size (approximately 99.5% or higher for 0.75 𝜇 m particles). 5”
From Assessment of N95 and K95 respirator decontamination: fiber integrity, filtration efficiency, and dipole charge density (2020) · cites this paper as [5]
In the citing paper
“with an average aerodynamic diameter reported to range from approximately 0.8-1.1 µm.(14,16,17)”
From Performance of Conventional and Antimicrobial-Treated Filtering Facepiece Respirators Challenged with Biological Aerosols (2012) · cites this paper as [16]
In the citing paper
“Moreover, previous studies have shown agreement between physical penetrations of inert and biological aerosols at particle sizes of 1 µm and above.(13,16,24,31,32)”
From Performance of Conventional and Antimicrobial-Treated Filtering Facepiece Respirators Challenged with Biological Aerosols (2012) · cites this paper as [16]
In the citing paper
“wearing surgical or FFP2 masks substantially reduces the number of bioaerosol particles emitted from human respiration.”
From Bacteria Filtration Efficiency for Different Types of Protective Face Masks (2023) · cites this paper as [26]
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Aerosol penetration and leakae characteristics of masks used in the health care industry
Weber, A. M., Willeke, K., Marchloni, R., Myojo, T., McKay, R. T., Donnelly, J., & Liebhaber, F. B. (1993) · American Journal of Infection Control · doi:10.1016/0196-6553(93)90027-2 · Cited by 156
Self-citationChen, S.-K., Vesley, D., Brosseau, L. M., & Vincent, J. H. (1994) · American Journal of Infection Control · doi:10.1016/0196-6553(94)90116-3 · Cited by 124
Penetration of Airborne Microorganisms Through a Surgical Mask and a Dust/Mist Respirator
Willeke, K., Qian, Y., Donnelly, J., Grinshpun, S., & Ulevicius, V. (1996) · American Industrial Hygiene Association Journal · doi:10.1080/15428119691014882 · Cited by 84
Self-citationCalibration and performance of an API Aerosizer
Cheng, Y., Barr, E. B., Marshall, I. A., & Mitchell, J. P. (1993) · Journal of Aerosol Science · doi:10.1016/0021-8502(93)90034-7 · Cited by 58
Efficacy of Selected Respiratory Protective Equipment Challenged with Bacillus subtilis subsp. niger
Johnson, B., Martin, D. D., & Resnick, I. G. (1994) · Applied and Environmental Microbiology · doi:10.1128/aem.60.6.2184-2186.1994 · Cited by 44
STEVENS, G. A., & MOYER, E. S. (1989) · American Industrial Hygiene Association Journal · doi:10.1080/15298668991374615 · Cited by 39
AEROSOL PENETRATION THROUGH FILTERING FACEPIECES AND RESPIRATOR CARTRIDGES
Chen, C. C., Lehtimäki, M., & Willeke, K. (1992) · American Industrial Hygiene Association Journal · doi:10.1080/15298669291360166 · Cited by 37
Self-citationRESPIRATOR PERFORMANCE RATING TABLE FOR MASK DESIGN
Johnson, A. T., Weiss, R. A., & Grove, C. M. (1992) · American Industrial Hygiene Association Journal · doi:10.1080/15298669291359500 · Cited by 37
Dynamic size spectrometry of airborne microorganisms: Laboratory evaluation and calibration
Qian, Y., Willeke, K., Ulevičius, V., Grinshpun, S. A., & Donnelly, J. (1995) · Atmospheric Environment · doi:10.1016/1352-2310(95)00043-x · Cited by 37
Self-citationHan, D.-H., Willeke, K., & Colton, C. E. (1997) · American Industrial Hygiene Association Journal · doi:10.1080/15428119791012874 · Cited by 29
Self-citation
Cited by
Review of Aerosol Transmission of Influenza A virus
Tellier, R. (2006) · Emerging Infectious Diseases · doi:10.3201/eid1211.060426 · Cited by 803
Particle Sizes of Infectious Aerosols: Implications for Infection Control
Fennelly, K. P. (2020) · The Lancet Respiratory Medicine · doi:10.1016/s2213-2600(20)30323-4 · Cited by 621
An overview of filtration efficiency through the masks: Mechanisms of the aerosols penetration
Tcharkhtchi, A., Abbasnezhad, N., Zarbini Seydani, M., Zirak, N., Farzaneh, S., & Shirinbayan, M. (2021) · Bioactive Materials · doi:10.1016/j.bioactmat.2020.08.002 · Cited by 395
“With lower speeds, the particle residence period is increased by means of filter media; hence the likelihood of collision between particle and filter media is increased dramatically [31].”
InfluentialBałazy, A., Toivola, M., Adhikari, A., Sivasubramani, S. K., Reponen, T., & Grinshpun, S. A. (2006) · American Journal of Infection Control · doi:10.1016/j.ajic.2005.08.018 · Cited by 376
“evaluate the respirator performance directly with biologic particles have been primarily focused on airborne bacteria.(7,11-16) N95 filtering face piece respirators are certified under NIOSH 42 CFR 84 regulations.”
MethodSelf-citationFace masks effectively limit the probability of SARS-CoV-2 transmission
Cheng, Y., Ma, N., Witt, C., Rapp, S., Wild, P. S., Andreae, M. O., Pöschl, U., & Su, H. (2021) · Science · doi:10.1126/science.abg6296 · Cited by 338
Smith, J. D., MacDougall, C. C., Johnstone, J., Copes, R. A., Schwartz, B., & Garber, G. E. (2016) · Canadian Medical Association Journal · doi:10.1503/cmaj.150835 · Cited by 328
Short-range airborne transmission of expiratory droplets between two people
Liu, L., Li, Y., Nielsen, P. V., Wei, J., & Jensen, R. L. (2017) · Indoor Air · doi:10.1111/ina.12314 · Cited by 310
“The susceptible individual could also use various personal protection devices, such as a N95 respirator, which is more effective than surgical masks (Qian et al, 1998).”
BackgroundTang, J. W., Liebner, T. J., Craven, B. A., & Settles, G. S. (2009) · Journal of The Royal Society Interface · doi:10.1098/rsif.2009.0295.focus · Cited by 300
“The N95, on the other hand, is designated a ‘particulate respirator and surgical mask’, and is approved by NIOSH (The National Institute for Occupational Safety and Health) (Qian et al. 1998).”
BackgroundInfluentialShiu, E. Y. C., Leung, N. H. L., & Cowling, B. J. (2019) · Current Opinion in Infectious Diseases · doi:10.1097/qco.0000000000000563 · Cited by 235
(2005) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/mei058 · Cited by 234
“The performance of filtering-facepiece respirators has been extensively tested using non-biological particles (Chen and Willeke, 1992; Qian et al., 1997b, 1998; Barrett and Rousseau, 1998; Huang et al., 1998; Han, 2000; Martin and Moyer, 2000) as well as biological particles (Brosseau et al., 1997;…”
BackgroundMethodSelf-citationAirborne transmission of disease in hospitals
Eames, I., Tang, J. W., Li, Y., & Wilson, P. (2009) · Journal of The Royal Society Interface · doi:10.1098/rsif.2009.0407.focus · Cited by 216
Microbial aerosols in general dental practice
Bennett, A. M., Fulford, M. R., Walker, J. T., Bradshaw, D. J., Martin, M. V., & Marsh, P. D. (2000) · British Dental Journal · doi:10.1038/sj.bdj.4800859 · Cited by 208
Thakur, R., Das, D., & Das, A. (2013) · Separation & Purification Reviews · doi:10.1080/15422119.2012.681094 · Cited by 199
A comparison of facemask and respirator filtration test methods
Rengasamy, S., Shaffer, R., Williams, B., & Smit, S. (2017) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2016.1225157 · Cited by 198
Balachandar, S., Zaleski, S., Soldati, A., Ahmadi, G., & Bourouiba, L. (2020) · International Journal of Multiphase Flow · doi:10.1016/j.ijmultiphaseflow.2020.103439 · Cited by 191
Evaluation of Multiple (3-Cycle) Decontamination Processing for Filtering Facepiece Respirators
Bergman, M. S., Viscusi, D. J., Heimbuch, B. K., Wander, J. D., Sambol, A. R., & Shaffer, R. E. (2010) · Journal of Engineered Fibers and Fabrics · doi:10.1177/155892501000500405 · Cited by 177
Brown, E., Macdonald, A., Allen, S., & Allen, D. (2023) · Journal of Hazardous Materials Advances · doi:10.1016/j.hazadv.2023.100309 · Cited by 172
Personal protective equipment and Covid 19- a risk to healthcare staff?
Herron, J. B. T., Hay-David, A. G. C., Gilliam, A., & Brennan, P. A. (2020) · British Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.bjoms.2020.04.015 · Cited by 168
“N95/FFP2 masks are at least 95% effective for particle sizes 0.1 to 0.3 µm which increases to 99.5% or higher for particles that are 0.75 µm or bigger (19) .”
InfluentialIn vivo protective performance of N95 respirator and surgical facemask
Li, Y., Wong, T., Chung, J., Guo, Y. P., Hu, J. Y., Guan, Y. T., Yao, L., Song, Q. W., & Newton, E. (2006) · American Journal of Industrial Medicine · doi:10.1002/ajim.20395 · Cited by 159
Respiratory protection against bioaerosols: Literature review and research needs
Rengasamy, A., Zhuang, Z., & BerryAnn, R. (2004) · American Journal of Infection Control · doi:10.1016/j.ajic.2004.04.199 · Cited by 138
“A comparison of unloaded N95 particulate respirators with that of DM and DFM respirators against Bacillus subtilis and Bacillus megatherium and inert test particles were performed.26 The penetration of both B subtilis and B megatherium was comparatively more with DM and DFM respirators than with N95 respirators at a f…”
BackgroundMethodResultInfluentialFace masks against COVID-19: Standards, efficacy, testing and decontamination methods
Ju, J. T. J., Boisvert, L. N., & Zuo, Y. (2021) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2021.102435 · Cited by 151
“For small particles, decreasing the airflow rate would increase the PFE because there ismore time for electrostatic attraction and Brownian diffusion to capture the particles [59,69].”
Rengasamy, S., King, W. P., Eimer, B. C., & Shaffer, R. E. (2008) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620802275387 · Cited by 124
The Spread of Influenza and Other Respiratory Viruses: Complexities and Conjectures
Hall, C. B. (2007) · Clinical Infectious Diseases · doi:10.1086/519433 · Cited by 116
“Those most commonly recommended procedures have aimed primarily at interrupting spread among close con- tacts from large droplets and from secretions that contaminate fomites, and precautions preventing airborne transmission are applied only to rooms that house patients whose illness is proven or suspected to be influ…”
BackgroundEffectiveness of surgical masks against influenza bioaerosols
Makison Booth, C., Clayton, M., Crook, B., & Gawn, J. M. (2013) · Journal of Hospital Infection · doi:10.1016/j.jhin.2013.02.007 · Cited by 132
Protecting healthcare workers from pandemic influenza: N95 or surgical masks?
Gralton, J., & McLaws, M.-L. (2010) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181b9e8b3 · Cited by 113
Safe tracheostomy for patients with severe acute respiratory syndrome
Wei, W., Tuen, H. H., Ng, R. W. M., & Lam, L. K. (2003) · The Laryngoscope · doi:10.1097/00005537-200310000-00022 · Cited by 123
Brat, G. A., Hersey, S., Chhabra, K. R., Gupta, A., & Scott, J. W. (2020) · Annals of Surgery · doi:10.1097/sla.0000000000003926 · Cited by 121
Penetration of 4.5nm to aerosol particles through fibrous filters
Huang, S.-H., Chen, C.-W., Chang, C.-P., Lai, C.-Y., & Chen, C.-C. (2007) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2007.05.007 · Cited by 108
Total Inward Leakage of Nanoparticles Through Filtering Facepiece Respirators
Rengasamy, S., & Eimer, B. C. (2011) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/meq096 · Cited by 109
“Several studies reported that NIOSHapproved FFRs provided expected levels of filtration efficiency against polydisperse and monodisperse aerosols .20 nm size (Qian et al., 1998; Willeke and Qian, 1998; Martin and Moyer, 2000; Rengasamy et al., 2007).”
The Dangers of Electrosurgical Smoke to Operating Room Personnel: A Review
Bree, K., Barnhill, S. W., & Rundell, W. K. (2017) · Workplace Health & Safety · doi:10.1177/2165079917691063 · Cited by 105
Jung, S., & Kim, J. (2020) · Polymers · doi:10.3390/polym12081714 · Cited by 106
Yim, W., Cheng, D., Patel, S., Kui, R., Meng, Y. S., & Jokerst, J. V. (2020) · medRxiv · doi:10.1101/2020.07.07.20148551 · Cited by 104
Tracheostomy guidelines developed at a large academic medical center during the COVID ‐19 pandemic
David, A. P., Russell, M. D., El‐Sayed, I. H., & Russell, M. S. (2020) · Head & Neck · doi:10.1002/hed.26191 · Cited by 91
“75 μm, providing excellent protection against airborne particles with a mask that is appropriately fitted.(10)”
BackgroundDas, D., Pradhan, A. K., Chattopadhyay, R., & Singh, S. N. (2012) · Textile Progress · doi:10.1080/00405167.2012.670014 · Cited by 92
A Review of Filtration Performance of Protective Masks
Wang, A.-B., Zhang, X., Gao, L., Zhang, T., Xu, H., & Bi, Y. (2023) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph20032346 · Cited by 90
“In the interception mechanism, the smaller the particle size, the more obvious the interception; however, there is no obvious relationship between interception and a reduction in particle size [67].”
BackgroundUniversal trends in human cough airflows at large distances
Simha, P. P., & Rao, P. S. M. (2020) · Physics of Fluids · doi:10.1063/5.0021666 · Cited by 87
Guan, T., Hu, S., Han, Y., Wang, R., Zhu, Q., Hu, Y., Fan, H., & Zhu, T. (2018) · Particle and Fibre Toxicology · doi:10.1186/s12989-018-0266-0 · Cited by 87
N95 and P100 Respirator Filter Efficiency Under High Constant and Cyclic Flow
Eshbaugh, J. P., Gardner, P. D., Richardson, A. W., & Hofacre, K. C. (2008) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620802558196 · Cited by 84
Polymer Materials for Respiratory Protection: Processing, End Use, and Testing Methods
Armentano, I., Barbanera, M., Carota, E., Crognale, S., Marconi, M., Rossi, S., Rubino, G., Scungio, M., Taborri, J., & Calabrò, G. (2021) · ACS Applied Polymer Materials · doi:10.1021/acsapm.0c01151 · Cited by 84
Respiratory source control using a surgical mask: An in vitro study
Patel, R. B., Skaria, S. D., Mansour, M. M., & Smaldone, G. C. (2015) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2015.1043050 · Cited by 82
“Respirators, in contrast, are designated as inhalational protection devices.[5-7] Regulatory recommendations are often based on in vitro assessments of filtration efficiency.”
BackgroundLee, K., Slavcev, A., & Nicas, M. (2004) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620490250026 · Cited by 77
“During a fit test, each subject performed six exercises: (1) normal breathing, (2) deep breathing, (3) moving the head side to side, (4) moving the head up and down, (5) talking, and (6) normal breathing.”
BackgroundMethodDuncan, S., Bodurtha, P., & Naqvi, S. (2021) · PLOS ONE · doi:10.1371/journal.pone.0258191 · Cited by 75
(2012) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/mer122 · Cited by 75
Lee, S.-A., Adhikari, A., Grinshpun, S. A., McKay, R., Shukla, R., Zeigler, H. L., & Reponen, T. (2005) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620500330583 · Cited by 73
“Qian et al.(8) found that the filtration efficiency of some N95 filtering facepiece respirators is 99.”
BackgroundInfluentialSelf-citationSurvival of Bacteria on Respirator Filters
Wang, Z. (1999) · Aerosol Science and Technology · doi:10.1080/027868299304651 · Cited by 71
Analysis of Residual Chemicals on Filtering Facepiece Respirators After Decontamination
Salter, W. B., Kinney, K. R., Wallace, W. H., Lumley, A. E., Heimbuch, B. K., & Wander, J. D. (2010) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2010.484794 · Cited by 71
“(5) (6) (7) (8) (9) (10) The modes for human-to-human transmission of influenza are actively debated, (11) (12) (13) (14) (15) (16) but data have been reported that support aerosol transmission.”
BackgroundKo, Y., Joe, Y. H., Seo, M., Lim, K., Hwang, J., & Woo, K. (2014) · Journal of Materials Chemistry B · doi:10.1039/c4tb01068j · Cited by 71
Sakaguchi, H., Wada, K., Kajioka, J., Watanabe, M., Nakano, R., Hirose, T., Ohta, H., & Aizawa, Y. (2010) · Environmental Health and Preventive Medicine · doi:10.1007/s12199-010-0149-y · Cited by 65
“Surgical masks and N95 particulate respirators are made from non-woven fabric and are used by healthcare professionals during patient examinations [9, 17, 18] or by patients to prevent transmission of a virus [19, 20].”
BackgroundPersistence of the 2009 Pandemic Influenza A (H1N1) Virus on N95 Respirators
Coulliette, A. D., Perry, K. A., Edwards, J. R., & Noble‐Wang, J. (2013) · Applied and Environmental Microbiology · doi:10.1128/aem.03850-12 · Cited by 63
Cellulose acetate and polyvinylidene fluoride nanofiber mats for N95 respirators
Akduman, Ç. (2019) · Journal of Industrial Textiles · doi:10.1177/1528083719858760 · Cited by 63
Rengasamy, S., Eimer, B. C., & Szalajda, J. (2014) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2013.866715 · Cited by 61
“(21) After the experiment, fluorescent stain on the faces and KCl concentrations in different layers of FFRs and SMs were analyzed to calculate the filter efficiency.”
Nanofibers in face masks and respirators to provide better protection
Akduman, Ç., & Kumbasar, E. P. A. (2018) · IOP Conference Series Materials Science and Engineering · doi:10.1088/1757-899x/460/1/012013 · Cited by 60
Numerical simulation of virus diffusion in facemask during breathing cycles
Li, Y., Li, F., & Zhu, Q. (2005) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2005.03.030 · Cited by 57
“[4] further studied the penetration efficiency of N95 respirators for airborne microbial and inert”
Rengasamy, S., Miller, A., & Eimer, B. C. (2011) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2010.515556 · Cited by 54
“(13,14,16–18) In one study, a particle spectrometer was employed to measure the penetration levels for N95 respirators using polydisperse NaCl aerosols.(16) Their results showed filtration efficiency for N95 respirators, for all sizes (120 to 700 nm range) of particles tested, higher than dust/mist (DM) and dust/mist/…”
BackgroundMethodLiu, Z., Yao, G., Li, Y., Huang, Z., Jiang, C., He, J., Wu, M., Liu, J., & Liu, H. (2022) · Building and Environment · doi:10.1016/j.buildenv.2022.109624 · Cited by 53
“where P is the infection probability, θ is the filtration efficiency of the N95 masks (95%) [57,58], and patients have no mask protection during treatment.”
(2005) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/meh097 · Cited by 50
“Several studies have evaluated the factors that can affect the respiratory protection against airborne particles, such as leak location, leak shape, leak size, respirator type, facial dimension, particle shape, particle size, inhalation rate and inhalation resistance (Chen et al., 1990, 1992; Willeke et al., 1996; Cru…”
InfluentialSelf-citationIvanoska-Dacikj, A., & Stachewicz, U. (2020) · REVIEWS ON ADVANCED MATERIALS SCIENCE · doi:10.1515/rams-2020-0048 · Cited by 51
Bhandari, P., Subramaniam, S., Bourke, M. J., Alkandari, A. A., Chiu, P. W. Y., Brown, J. F., Keswani, R. N., Bisschops, R., Hassan, C., Raju, G. S., et al. (2020) · Gut · doi:10.1136/gutjnl-2020-322329 · Cited by 50
Utility of Substandard Face Mask Options for Health Care Workers During the COVID-19 Pandemic
Abd-Elsayed, A. A., & Karri, J. V. (2020) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000004841 · Cited by 50
Advances in Antiviral Material Development
Liang, L., Ahamed, A., Ge, L., Fu, X., & Lisak, G. (2020) · ChemPlusChem · doi:10.1002/cplu.202000460 · Cited by 50
Collins, A. P., Service, B. C., Gupta, S., Mubarak, N., Zeini, I. M., Osbahr, D. C., & Romeo, A. A. (2021) · Journal of the American College of Emergency Physicians Open · doi:10.1002/emp2.12582 · Cited by 50
“Inclusion criteria for this study were based on (1) participant type: humans with influenza, influenza-like illness, or other respiratory viral infections; (2) study type: randomized controlled trial, non-randomized controlled study, case-control study, and cohort study; (3) intervention: N95 respirator and surgical m…”
BackgroundMethodFitting Characteristics of N95 Filtering-Facepiece Respirators Used Widely in China
Yu, Y.-Y., Jiang, L.-M., Zhuang, Z., Liu, Y., Wang, X., Liu, J., Ming-na, Y., & Chen, W. (2014) · PLoS ONE · doi:10.1371/journal.pone.0085299 · Cited by 50
“In addition to reduce industrial dust exposure, FFRs are widely used to reduce inhalation of aerosols from volcanic explosions and sandstorms or to prevent respiratory infections, such as influenza, by the general population [5,6].”
BackgroundGuo, W., Fu, Y., Jia, R., Guo, Z., Su, C., Li, J., Zhao, X., Jin, Y., Li, P., Fan, J., et al. (2022) · Environment International · doi:10.1016/j.envint.2022.107153 · Cited by 49
“The deposition rate of aerosol particles in the human body, fmask, was considered 95% with the mask and 0 without it (Qian et al. 1998).”
The face behind the Covid-19 mask — A comprehensive review
Ganesapillai, M., Mondal, B., Sarkar, I., Sinha, A., Ray, S. S., Kwon, Y., Nakamura, K., & Govardhan, K. (2022) · Environmental Technology & Innovation · doi:10.1016/j.eti.2022.102837 · Cited by 48
Unipolar ion emission enhances respiratory protection against fine and ultrafine particles
Lee, B. U., Yermakov, M., & Grinshpun, S. A. (2004) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2004.05.006 · Cited by 48
“The penetration eFciency of larger Mycobacterium tuberculosis bacteria (Mtb, 0:8 m) through a face-sealed N95 respirator at strenuous workload is as low as about 0.5% (Qian et al., 1998).”
InfluentialSelf-citationRisk assessment for long- and short-range airborne transmission of SARS-CoV-2, indoors and outdoors
Poydenot, F., Abdourahamane, I., Caplain, E., Der, S., Haiech, J., Jallon, A., Khoutami, I., Loucif, A., Marinov, E., & Andreotti, B. (2022) · PNAS Nexus · doi:10.1093/pnasnexus/pgac223 · Cited by 48
International consensus on lung function testing during the COVID-19 pandemic and beyond
McGowan, A., Laveneziana, P., Bayat, S., Beydon, N., Boros, P. W., Burgos, F., Fležar, M., Franczuk, M., Galarza-Jimenez, M.-A., Kendrick, A. H., et al. (2021) · ERJ Open Research · doi:10.1183/23120541.00602-2021 · Cited by 45
How Should Rehabilitative Departments of Hospitals Prepare for Coronavirus Disease 2019?
Chang, M. C., & Park, D. (2020) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0000000000001428 · Cited by 43
Yassi, A., Bryce, E., Moore, D., Janssen, R., Copes, R., Bartlett, K. H., Fitzgerald, M., Gilbert, M., Bigelow, P., Danyluk, Q., et al. (2004) · TMUshare (Toronto Metropolitan University) · doi:10.32920/23935254.v1 · Cited by 43
Le, B., Omran, N., Elnabawy, E., Hassanin, A. H., Mahmoud, K., Shehata, N., & Shyha, I. (2024) · Emergent Materials · doi:10.1007/s42247-023-00622-9 · Cited by 42
“Lower speeds lead to a longer residence period of the particles, increasing the probability of particle-fiber collisions [69].”
Interventions to control nosocomial transmission of SARS-CoV-2: a modelling study
Pham, T. M., Tahir, H., van de Wijgert, J. H. H. M., der Roest, B. R. V., Ellerbroek, P. M., Bonten, M. J. M., Bootsma, M., & Kretzschmar, M. (2021) · BMC Medicine · doi:10.1186/s12916-021-02060-y · Cited by 41
He, X., Grinshpun, S. A., Reponen, T. A., McKay, R. T., Bergman, M. S., & Zhuang, Z. (2013) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/met053 · Cited by 42
“This has been demonstrated for mechanical and “electret” filters tested under constant- and cyclic-flow conditions (Chen et al., 1990; Brown, 1993; Qian et al., 1998; Martin and Moyer, 2000; Bałazy et al., 2006b; Huang et al., 2007; Eninger et al., 2008; Rengasamy et al., 2008, 2009; Cho et al., 2010b).”
MethodSelf-citationZhang, J., Zhao, Y., Wen, S., Tu, D., Liu, J., & Liu, S. (2024) · Energy and Buildings · doi:10.1016/j.enbuild.2024.114002 · Cited by 40
Shakya, K. M., Rupakheti, M., Aryal, K. K., & Peltier, R. E. (2016) · Journal of Occupational and Environmental Medicine · doi:10.1097/jom.0000000000000753 · Cited by 40
“These masks have been well characterized as significantly reducing PM exposure with filtration efficiencies exceeding 95% (by mass for particles between 20 nm and 2 mm).(28,29) Statistical tests were run using available statistical packages in R.”
MethodWhyte, H. E., Montigaud, Y., Audoux, E., Verhoeven, P. O., Prier, A., Leclerc, L., Sarry, G., Laurent, C., Coq, L. L., Joubert, A., et al. (2022) · Scientific Reports · doi:10.1038/s41598-022-05245-4 · Cited by 40
Perng, D., & Chen, P.-K. (2017) · Tuberculosis & respiratory diseases · doi:10.4046/trd.2017.0085 · Cited by 39
He, X., Reponen, T. A., McKay, R. T., & Grinshpun, S. A. (2014) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2013.848037 · Cited by 39
“, NaCl) differs from that of bioaerosols, several studies have confirmed that filter performance against biological particles is consistent with that determined using non-biological particles of the same size.(5,7,16) This suggests that inert aerosol surrogates such as NaCl particles may generally be appropriate for p…”
BackgroundResultSelf-citationRatnesar-Shumate, S. A., Wu, C., Wander, J., Lundgren, D. A., Farrah, S. R., Lee, J., Wanakule, P., Blackburn, M. B., & Lan, M.-F. (2008) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2007.08.0036 · Cited by 39
Rashid, T. U., Sharmeen, S., & Biswas, S. (2022) · ACS Chemical Health & Safety · doi:10.1021/acs.chas.1c00016 · Cited by 38
Manikin-Based Performance Evaluation of Elastomeric Respirators Against Combustion Particles
He, X., Yermakov, M. V., Reponen, T. A., McKay, R. T., James, K., & Grinshpun, S. A. (2013) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2012.760063 · Cited by 38
“Some investigators used polystyrene latex spheres as challenge aerosol in their tests.(26,27) Others used fungal spores, bacteria, or viruses.”
MethodSelf-citationSICO (Italian Society of Surgical Oncology), Cavaliere, D., Parini, D., Marano, L., Cipriani, F., Marzo, F. D., Macrì, A., D’Ugo, D., Roviello, F., & Gronchi, A. (2020) · Updates in Surgery · doi:10.1007/s13304-020-00921-4 · Cited by 37
Maschmeyer, G., Neuburger, S., Fritz, L., Böhme, A., Penack, O., Schwerdtfeger, R., Buchheidt, D., & Ludwig, W.-D. (2009) · Annals of Oncology · doi:10.1093/annonc/mdp034 · Cited by 37
“Disposable surgical masks, although most frequently employed, are not suitable for effectively filtering small particles [26], whereas masks according to the N95 standard in the United States or the FFP2 class in Europe have been proven to effectively prevent inhalation of these particles, including fungal spores [9,…”
BackgroundLiverman, C. T., Ta, H., Meb, R., & Ki, S. (2009) · Cited by 37
Vlaskin, M. S. (2021) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2021.117855 · Cited by 35
“Filters containing calcined and hydrated dolomites, hydroxyapatite crystals, tungsten oxide, iodide particles (palladium (II), silver (I), copper (I)), or activated carbon are also better at adsorbing and inactivating viruses from the air [104].”
Eninger, R. M., Adhikari, A., Reponen, T. A., & Grinshpun, S. A. (2008) · CLEAN - Soil Air Water · doi:10.1002/clen.200700198 · Cited by 35
Self-citationLee, B. U., Yermakov, M., & Grinshpun, S. A. (2005) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2005.06.0003 · Cited by 35
“…studied over the years (Brosseau et al., 1989; Chen et al., 1994; Hinds et al., 1988; Huang et al., 1998; Johnson et al., 1994; Johnston et al., 2001; Lee et al., 2004c; Nicas et al., 2003; Oestenstad et al., 1990; Qian et al., 1997; Qian et al., 1998; Weber et al., 1993; Willeke et al., 1996).”
Self-citationZou, Z., & Yao, M. (2014) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2014.10.003 · Cited by 35
Wehling, J., Volkmann, E., Grieb, T., Rosenauer, A., Maas, M., Treccani, L., & Rezwan, K. (2013) · Environmental Pollution · doi:10.1016/j.envpol.2013.02.001 · Cited by 34
Efficacy of iodine-treated biocidal filter media against bacterial spore aerosols
Lee, J.-H., Wu, C.-Y., Wysocki, K. M., Farrah, S. R., & Wander, J. (2008) · Journal of Applied Microbiology · doi:10.1111/j.1365-2672.2008.03855.x · Cited by 34
“Surviving micro-organisms on filters can re-entrain into the air passing through the filter medium, which has been reported in several studies (Qian et al. 1998; Wang et al. 1999; Jankowska et al. 2000).”
BackgroundHealth impacts of biomass air pollution
Brauer, M. D. (2008) · cIRcle (University of British Columbia) · doi:10.14288/1.0048198 · Cited by 34
Bergman, M. S., Zhuang, Z., Brochu, E., & Palmiero, A. J. (2015) · Journal of the International Society for Respiratory Protection · doi:10.66828/001c.166885 · Cited by 33
Commentary: The Use of Respirators to Reduce Inhalation of Airborne Biological Agents
Janssen, L., Ettinger, H. J., Graham, S., Shaffer, R. E., & Zhuang, Z. (2013) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2013.799964 · Cited by 33
“(7) (8) (9) (10) (11) (12) (13) Filtration efficiency criteria for N95 FFR are set by NIOSH and are measured under rigorous test conditions.”
Mahdavi, A., Bahloul, A., Haghighat, F., & Ostiguy, C. (2013) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/met051 · Cited by 33
Air pollution, human health and the benefits of trees: a biomolecular and physiologic perspective
Mei, P., Malik, V., Harper, R. W., & Jiménez, J. M. (2021) · Arboricultural Journal · doi:10.1080/03071375.2020.1854995 · Cited by 33
Survival of Mycobacteria on N95 Personal Respirators
Reponen, T. A., Wang, Z., Willeke, K., & Grinshpun, S. A. (1999) · Infection Control and Hospital Epidemiology · doi:10.1086/501618 · Cited by 32
Self-citationLeung, W. T., Sze-To, G. N., Chao, C. Y. H., Yu, S. C. T., & Kwan, J. K. C. (2012) · Indoor Air · doi:10.1111/j.1600-0668.2012.00797.x · Cited by 32
Pan, S., Xu, C., Yu, C. W., & Liu, L. (2022) · Indoor and Built Environment · doi:10.1177/1420326x221110975 · Cited by 31
“77 Study on various homemade face masks also found that the fi l-tration ef fi ciency for particles >2.5 μ m is typically higher than that for particles 0.1 μ m. 41 The measured droplet concentration of breathing or speaking in this study was basically consistent with the results of Fairchild and…”
BackgroundResultInfluentialViable Viral Efficiency of N95 and P100 Respirator Filters at Constant and Cyclic Flow
Gardner, P. D., Eshbaugh, J. P., Harpest, S. D., Richardson, A. W., & Hofacre, K. C. (2013) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2013.818228 · Cited by 31
“(15) (16) (17) (18) (19) (20) (21) (22) The FFRs for the most part have been shown to provide protection at or better than their NIOSH certification rating.”
BackgroundThe COVID-19 from Neurological Overview
Acar, T., DEMİREL, E. A., Afşar, N., Akçalı, A., Demir, G. A., Alagöz, A. N., Mengi, T., Arsava, E. M., Ayta, S., Bebek, N., et al. (2020) · Turkish Journal Of Neurology · doi:10.4274/tnd.2020.73669 · Cited by 34
Antibacterial agents applied as antivirals in textile-based PPE: a narrative review
Raza, Z. A., Taqi, M., & Tariq, M. R. (2021) · Journal of the Textile Institute · doi:10.1080/00405000.2021.1889166 · Cited by 29
“Their blocking capacity increases to 99.5% for the particles of size 0.75 mm (Qian et al., 1998).”
BackgroundInfluential
Metadata
- Authors
- Qian, Y., Willeke, K., Grinshpun, S. A., Donnelly, J., & Coffey, C. C.
- Affiliations
- University of Cincinnati (US)
- Centers for Disease Control and Prevention (US)
- ORCID
- Grinshpun, Sergey A.
- Venue
- American Industrial Hygiene Association Journal
- Publisher
- Informa UK Limited
- Published
- 1998-02
- Volume
- 59
- Issue
- 2
- Pages
- 128-132
- ISSN
- 0002-8894 (ISSN-L)
- OpenAlex
- W2110642136
- Semantic Scholar
- d74dd53b1e298bfe66b53b460e63b1ab5e1a8100
- Cited by
- 298
- References
- 12
- Citations by year
- 2026: 7 · 2025: 3 · 2024: 20 · 2023: 21 · 2022: 34 · 2021: 50 · 2020: 44 · 2019: 3 · 2018: 3 · 2017: 4 · 2016: 9 · 2015: 6 · 2014: 7 · 2013: 15 · 2012: 5
- FWCI
- 1.34
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- American Industrial Hygiene Association Journal (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institute for Occupational Safety and Health (R01-OH03244)
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Aerosol Filtration and Electrostatic Precipitation
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Occupational Health and Safety in Workplaces
- Keywords
- N95 respirators, particulate respirators, filtration efficiency, airborne bacteria, inert particles, Mycobacterium tuberculosis, surgical masks, face seals, welding fumes, submicron particles
- MeSH terms
- Aerosols, Air Microbiology, Air Pollution, Equipment Design, Filtration, Humans, Mycobacterium tuberculosis, Particle Size, Respiratory Protective Devices, United States
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.