What Is an Effective Portable Air Cleaning Device? A Review
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
The use of portable air cleaning devices in residential settings has been steadily growing over the last 10 years. Three out of every 10 households now contain a portable air cleaning device. This increased use of air cleaners is accompanied by, if not influenced by, a fundamental belief by consumers that the air cleaners are providing an improved indoor air environment. However, there is a wide variation in the performance of air cleaners that is dependent on the specific air cleaner design and various indoor factors. The most widely used method in the United States to assess the performance of new air cleaners is the procedure described in the American National Standards Institute (ANSI)/Association of Home Appliance Manufacturers (AHAM) AC-1-2002. This method describes both the test conditions and the testing protocol. The protocol yields a performance metric that is based on the measured decay rate of contaminant concentrations with the air cleaner operating compared with the measured decay rate with the air cleaner turned off. The resulting metric, the clean air delivery rate (CADR), permits both an intercomparison of performance among various air cleaners and a comparison of air cleaner operation to other contaminant removal processes. In this article, we comment on the testing process, discuss its applicability to various contaminants, and evaluate the resulting performance metrics for effective air cleaning.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effects of room furnishings and air speed on particle deposition rates indoors
Thatcher, T. L., Lai, A. C. K., Moreno-Jackson, R., Sextro, R. G., & Nazaroff, W. W. (2002) · Atmospheric Environment · doi:10.1016/s1352-2310(02)00157-7 · Cited by 416 · cited 1×
“40) and Xu et al, 41) as reported by Fisk et al.”
BackgroundSelf-citationClearing the Air: Asthma and Indoor Air Exposures
Swanson, M. C. (2001) · Annals of Allergy, Asthma & Immunology · doi:10.1016/s1081-1206(10)62329-0 · Cited by 393
Indoor–outdoor relationships of respirable sulfates and particles
Dockery, D. W., & Spengler, J. D. (1981) · Atmospheric Environment (1967) · doi:10.1016/0004-6981(81)90036-6 · Cited by 273 · cited 1×
“(26 , 27) Mathematically, the “well-mixed box” equation is:”
Performance and costs of particle air filtration technologies: Air filtration technology
Fisk, W. J., Faulkner, D., Palonen, J., & Seppanen, O. (2002) · Indoor Air · doi:10.1034/j.1600-0668.2002.01136.x · Cited by 242 · cited 1×
“38) The dashed lines show the upper and lower bounds of the measurements reported by Thatcher.”
BackgroundChemical reactions among indoor pollutants: what we've learned in the new millennium
Weschler, C. J. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00287.x · Cited by 189 · cited 1×
“36) Vinyl pyridine measurements were conducted in only a few tests, and the resulting CADR values ranged from 6 to 55 ft 3 /min (10 to 94 m 3 /hour).”
MethodControl of respirable particles in indoor air with portable air cleaners
Offermann, F. J., Sextro, R. G., Fisk, W. J., Grimsrud, D. T., Nazaroff, W. W., Nero, A. V., Revzan, K. L., & Yater, J. (1985) · Atmospheric Environment (1967) · doi:10.1016/0004-6981(85)90003-4 · Cited by 162 · cited 1×
“Even though most of these devices were ineffective in terms of particle removal, 5) their marketing proved that portable air cleaners could be sold in the consumer market, thus paving the way for larger stand-alone air cleaners with more elaborate removal technologies.”
BackgroundSelf-citationPerformance of air cleaners for removing multiple volatile organic compounds in indoor air
Chen, W., Zhang, J. S., & Zhang, Z. (2005) · ASHRAE winter conference papers · Cited by 122
Deposition of Tobacco Smoke Particles in a Low Ventilation Room
Xu, M., Nematollahi, M., Sextro, R. G., Gadgil, A. J., & Nazaroff, W. W. (1994) · Aerosol Science and Technology · doi:10.1080/02786829408959676 · Cited by 109 · cited 1×
“40) and Xu et al, 41) as reported by Fisk et al.”
BackgroundSelf-citationProceedings of Indoor Air 2008, the 11th International Conference on Indoor Air Quality and Climate
Strøm-Tejsen, P., Olesen, B. W., Wargocki, P. L., Zukowska, D., & Toftum, J. (2008) · Technical University of Denmark, DTU Orbit (Technical University of Denmark, DTU) · Cited by 77
Technique for determining pollutant emissions from a gas-fired range
Traynor, G. W., Anthon, D. W., & Hollowell, C. D. (1982) · Atmospheric Environment (1967) · doi:10.1016/0004-6981(82)90049-x · Cited by 67 · cited 1×
“(26 , 27) Mathematically, the “well-mixed box” equation is:”
Methodology to Perform Clean Air Delivery Rate Type Determinations with Microbiological Aerosols
Foarde, K. K. (1999) · Aerosol Science and Technology · doi:10.1080/713834074 · Cited by 28
Cited by
How can airborne transmission of COVID-19 indoors be minimised?
Morawska, L., Tang, J. W., Bahnfleth, W., Bluyssen, P. M., Boerstra, A., Buonanno, G., Cao, J., Dancer, S., Floto, A., Franchimon, F., et al. (2020) · Environment International · doi:10.1016/j.envint.2020.105832 · Cited by 1,343
“design and size of room in which it is used (Shaughnessy and Sextro, 2006).”
Biological treatment of indoor air for VOC removal: Potential and challenges
Guieysse, B., Hort, C., Platel, V., Munoz, R., Ondarts, M., & Revah, S. (2008) · Biotechnology Advances · doi:10.1016/j.biotechadv.2008.03.005 · Cited by 308
Ten questions concerning green buildings and indoor air quality
Steinemann, A., Wargocki, P., & Rismanchi, B. (2017) · Building and Environment · doi:10.1016/j.buildenv.2016.11.010 · Cited by 268
Ultrafine particle removal and generation by portable air cleaners
Waring, M. S., Siegel, J. A., & Corsi, R. L. (2008) · Atmospheric Environment · doi:10.1016/j.atmosenv.2008.02.011 · Cited by 217
“Shaughnessy and Sextro (2006) report that 3 of 10 American households own one e front matter r 2008 Elsevier Ltd.”
BackgroundBlocken, B., van Druenen, T., Ricci, A., Kang, L., van Hooff, T., Qin, P., Xia, L., Ruiz, C. A., Arts, J. H., Diepens, J. F. L., et al. (2021) · Building and Environment · doi:10.1016/j.buildenv.2021.107659 · Cited by 183
“Shaughnessy and Sextro [105] reported data from Thatcher et al. [106] and Xu et al. [107] where KN for the size fraction 10–2.5 μm ranged from 1 to 10 h− 1, for 2.5–1 μm from 0.3 to 1 h− 1, for 1–0.5 μm from 0.1 to 0.3 h− 1, for 0.5–0.25 μm from 0.05 to 0.1 h− 1 and finally for the size fraction below 0.25 μm from 0.0…”
Influential
Metadata
- Authors
- Shaughnessy, R. J., & Sextro, R. G.
- Venue
- Journal of Occupational and Environmental Hygiene
- Publisher
- Informa UK Limited
- Published
- 2006-04
- Volume
- 3
- Issue
- 4
- Pages
- 169-181
- ISSN
- 1545-9624 (ISSN-L)
- 1545-9632
- OpenAlex
- W2088472655
- Cited by
- 182
- References
- 11
- FWCI
- 3.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.