Efficacy of Face Shields Against Cough Aerosol Droplets from a Cough Simulator
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Health care workers are exposed to potentially infectious airborne particles while providing routine care to coughing patients. However, much is not understood about the behavior of these aerosols and the risks they pose. We used a coughing patient simulator and a breathing worker simulator to investigate the exposure of health care workers to cough aerosol droplets, and to examine the efficacy of face shields in reducing this exposure. Our results showed that 0.9% of the initial burst of aerosol from a cough can be inhaled by a worker 46 cm (18 inches) from the patient. During testing of an influenza-laden cough aerosol with a volume median diameter (VMD) of 8.5 μm, wearing a face shield reduced the inhalational exposure of the worker by 96% in the period immediately after a cough. The face shield also reduced the surface contamination of a respirator by 97%. When a smaller cough aerosol was used (VMD = 3.4 μm), the face shield was less effective, blocking only 68% of the cough and 76% of the surface contamination. In the period from 1 to 30 minutes after a cough, during which the aerosol had dispersed throughout the room and larger particles had settled, the face shield reduced aerosol inhalation by only 23%. Increasing the distance between the patient and worker to 183 cm (72 inches) reduced the exposure to influenza that occurred immediately after a cough by 92%. Our results show that health care workers can inhale infectious airborne particles while treating a coughing patient. Face shields can substantially reduce the short-term exposure of health care workers to large infectious aerosol particles, but smaller particles can remain airborne longer and flow around the face shield more easily to be inhaled. Thus, face shields provide a useful adjunct to respiratory protection for workers caring for patients with respiratory infections. However, they cannot be used as a substitute for respiratory protection when it is needed. [Supplementary materials are available for this article. Go to the publisher's online edition of Journal of Occupational and Environmental Hygiene for the following free supplemental resource: tables of the experiments performed, more detailed information about the aerosol measurement methods, photographs of the experimental setup, and summaries of the experimental data from the aerosol measurement devices, the qPCR analysis, and the VPA.].
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Toward Understanding the Risk of Secondary Airborne Infection: Emission of Respirable Pathogens
Nicas, M., Nazaroff, W. W., & Hubbard, A. (2005) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620590918466 · Cited by 867 · cited 2×
“later revised this with newer data on the composition of respiratory fluids and concluded that particles needed to have initial diameters less than 20 μm to become droplet nuclei.(4) In an early photographic study, Jennison found that the majority of visible droplets produced during coughing and sneezing travel only 2…”
The role of particle size in aerosolised pathogen transmission: a review
Gralton, J., Tovey, E., McLaws, M.-L., & Rawlinson, W. D. (2011) · Journal of Infection · doi:10.1016/j.jinf.2010.11.010 · Cited by 665 · cited 1×
“The aerosol droplets generated during coughing span a broad size range, from tens of nanometers to hundreds of micrometers, and the dispersion of these droplets in the environment depends to a large degree upon their size.(3,4) Small aerosol droplets from a coughing patient can remain airborne and spread throughout a…”
Measurements of Airborne Influenza Virus in Aerosol Particles from Human Coughs
Lindsley, W. G., Blachere, F. M., Thewlis, R. E., Vishnu, A., Davis, K. A., Cao, G., Palmer, J. E., Clark, K. E., Fisher, M. A., Khakoo, R., et al. (2010) · PLoS ONE · doi:10.1371/journal.pone.0015100 · Cited by 423
Self-citationLindsley, W. G., Pearce, T. A., Hudnall, J. B., Davis, K. A., Davis, S. M., Fisher, M. A., Khakoo, R., Palmer, J. E., Clark, K. E., Celik, I., et al. (2012) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2012.684582 · Cited by 300
Self-citationExposure to Influenza Virus Aerosols During Routine Patient Care
Bischoff, W. E., Swett, K., Leng, I., & Peters, T. R. (2013) · The Journal of Infectious Diseases · doi:10.1093/infdis/jis773 · Cited by 226
Cited by
Verbeek, J. H., Rajamaki, B., Ijaz, S., Sauni, R., Toomey, E., Blackwood, B., Tikka, C., Ruotsalainen, J. H., & Kilinc Balci, F. S. (2020) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011621.pub4 · Cited by 657
Particle Sizes of Infectious Aerosols: Implications for Infection Control
Fennelly, K. P. (2020) · The Lancet Respiratory Medicine · doi:10.1016/s2213-2600(20)30323-4 · Cited by 621
Visualizing the effectiveness of face masks in obstructing respiratory jets
Verma, S., Dhanak, M., & Frankenfield, J. (2020) · Physics of Fluids · doi:10.1063/5.0016018 · Cited by 287
Verbeek, J. H., Rajamaki, B., Ijaz, S., Tikka, C., Ruotsalainen, J. H., Edmond, M. B., Sauni, R., & Kilinc Balci, F. S. (2019) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011621.pub3 · Cited by 276
Indoor air quality improvement in COVID-19 pandemic: Review
Agarwal, N., Meena, C. S., Raj, B. P., Saini, L., Kumar, A., Gopalakrishnan, N., Kumar, A., Balam, N. B., Alam, T., Kapoor, N. R., et al. (2021) · Sustainable Cities and Society · doi:10.1016/j.scs.2021.102942 · Cited by 255
Metadata
- Authors
- Lindsley, W. G., Noti, J. D., Blachere, F. M., Szalajda, J. V., & Beezhold, D. H.
- Venue
- Journal of Occupational and Environmental Hygiene
- Publisher
- Informa UK Limited
- Published
- 2014-06-27
- Volume
- 11
- Issue
- 8
- Pages
- 509-518
- ISSN
- 1545-9624 (ISSN-L)
- 1545-9632
- OpenAlex
- W2153032084
- Cited by
- 229
- References
- 5
- FWCI
- 1.21
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.