CoChat

Development of liquid phase microextraction-based deep eutectic solvent for the extraction and determination of toxic metal ions in herbal medicines

The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.

Abstract

Herein, an eco-friendly, simple, and inexpensive procedure was developed using vortex-assisted combined with deep eutectic solvent-based liquid phase microextraction (VA-LPME-DES) followed by graphite furnace atomic absorption spectrometry. In the present procedure, DES was first synthesized from the combination of l-menthol and (1S)-(+)-camphor-10-sulfonic acid (CSA) in a molar ratio of 5:1, and then it was used as a green and safe extractant instead of common toxic organic solvents. The ability of the presented method was applied for the separation and preconcentration of lead (Pb), cadmium (Cd), mercury (Hg), and arsenic (As) in herbal medicines. After optimizing all the parameters of the experiment, the linear ranges were 0.10–200 µg kg−1 with coefficient of determination (r2) better than 0.985. The limits of detection were in the ranges of 0.03–0.15 µg kg−1. Relative standard deviation values for intra-day and inter-day of the method based on 7 replicate measurements were in the range of 1.8%–3.6% and 3.1%–7.3%, respectively. The relative recoveries of herbal medicines which have been spiked with different concentrations of metal ions were 91.5%–109.8%. The method was successfully used to analyze the heavy and toxic metals in herbal medicine samples.

Overview

Integrity signals

Registry

Crossref · 10.1080/15569543.2024.2369158

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 30 references

Research works printed but not linked: 2

  1. World Health Organization. 2007. WHO guidelines for assessing quality of herbal medicines with reference to contaminants and residues. Geneva: WHO Press.
  2. World Health Organization. 2009. The use of herbal medicines in primary health care. New Delhi, India: World Health Organization South-East Asia Regional Office.

Cited by

See all 13

Metadata

Authors
Sun, J., Bao, W., Zhang, C., Chen, G., & Zhou, Z.
Affiliations
  • Tianjin University (CN)
  • Tianjin Tianlong Jinnar Aquatic Technology Development Co., Ltd, Tianjin, China
Corresponding author
Zhou, Zhijiang
Venue
Toxin Reviews
Published
2024-06-21
Volume
43
Issue
4
Pages
505-512
ISSN
  • 1556-9543 (ISSN-L)
  • 1556-9551
OpenAlex
W4399882980
Cited by
13
References
30
Citations by year
2026: 4 · 2025: 7 · 2024: 2
FWCI
2.24
Type
journal article
Language
en
Open access
closed
Locations
Toxin Reviews (publishedVersion)
Funders
Tianjin Agricultural Science and Technology (202101160)
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
  • Physical Sciences › Chemistry › Analytical Chemistry › Heavy Metals in Plants
  • Physical Sciences › Chemistry › Physical and Theoretical Chemistry › Ionic liquids properties and applications
Keywords
deep eutectic solvents, liquid-phase microextraction, vortex-assisted extraction, heavy metal determination, lead, cadmium, mercury, arsenic, herbal medicine, green solvents, L-menthol, camphor-10-sulfonic acid, preconcentration, graphite furnace atomic absorption spectrometry

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Development of liquid phase microextraction-based deep eutectic solvent for the extraction and determination of toxic metal ions in herbal medicines. https://app.cochat.ai/papers/10.1080/15569543.2024.2369158
The paper
Sun, J., Bao, W., Zhang, C., Chen, G., & Zhou, Z. (2024). Development of liquid phase microextraction-based deep eutectic solvent for the extraction and determination of toxic metal ions in herbal medicines. Toxin Reviews. https://doi.org/10.1080/15569543.2024.2369158

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.