CoChat

Real-time biofilm detection techniques: advances and applications

Kulshrestha, Anmol, Gupta, Pratima · 2024 · Future Microbiology
Cited by 21

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

biofilm characterization methods, though informative, often disrupt the biofilm structure. The need to address biofilm-related infections urgently emphasizes the importance of continuous monitoring and timely interventions. This review provides a focused examination of advancements in real-time biofilm detection techniques, specifically in electrochemical, optical and mechanical systems. The potential applications of real-time detection in managing and monitoring biofilm growth in industrial settings, preventing medical infections, comprehending biofilm dynamics and evaluating control strategies highlight the necessity for it. Crucially, the review emphasizes the importance of evaluating these methods for their accuracy and reliability in real-time biofilm detection, offering valuable insights for precise interventions across various applications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/17460913.2024.2350285

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 67

  1. 10.1016/j.btre.2021.e00613 · DOI
  2. 10.1093/femspd/ftac010 · DOI
  3. 10.1038/nrmicro.2016.94 · DOI · Paper page
  4. 10.3390/applmicrobiol3030044 · DOI · Paper page
  5. 10.3390/ma11101802 · DOI · Paper page
  6. 10.3389/fcimb.2021.763415 · DOI
  7. 10.1038/s41522-016-0007-9 · DOI · Paper page
  8. 10.1007/978-3-319-50409-4_5 · DOI
  9. 10.3390/microorganisms8121852 · DOI
  10. 10.1186/s13568-021-01232-6 · doi:10.1186/s13568-021-01232-6
  11. 10.3390/ijerph18147602 · DOI · Paper page
  12. 10.1128/CMR.00013-11 · DOI · Paper page
  13. 10.1128/mBio.00006-21 · DOI
  14. 10.1186/s13027-019-0220-2 · DOI
  15. 10.1001/jamaoto.2014.3208 · DOI
  16. 10.1177/0022034512442894 · DOI
  17. 10.1007/s00284-013-0468-5 · DOI
  18. 10.3389/fmicb.2019.02162 · DOI · Paper page
  19. 10.1186/s12890-017-0416-4 · DOI · Paper page
  20. 10.1073/pnas.1804084115 · DOI · Paper page
  21. 10.1038/nrmicro.2016.94 · DOI · Paper page
  22. 10.3389/fmicb.2018.02905 · DOI
  23. 10.1128/mBio.02668-19 · DOI
  24. 10.1021/acs.est.9b07134 · DOI
  25. 10.1073/pnas.1004880107 · DOI · Paper page
  26. 10.1016/j.nanoen.2018.05.072 · DOI
  27. 10.1080/08927010310000100800 · doi:10.1080/08927010310000100800
  28. 10.1016/j.jiec.2011.10.002 · DOI
  29. 10.2166/wst.2003.0278 · doi:10.2166/wst.2003.0278
  30. Sachsenheimer K, Pires L, Adamek M, et al. Monitoring biofilm growth using a scalable multichannel impedimetric biosensor. 15th International Conference on Miniaturized Systems for Chemistry and Life Sciences 2011. MicroTAS. 2011;3:1968–1970.
  31. 10.1007/s00253-008-1404-7 · DOI
  32. 10.1016/B978-1-78242-375-1.00003-4 · DOI
  33. 10.1080/08927014.2010.519025 · DOI
  34. 10.1109/JSEN.2015.2504495 · DOI
  35. 10.1016/j.aca.2022.340591 · doi:10.1016/j.aca.2022.340591
  36. 10.1016/j.eurpolymj.2024.112892 · DOI
  37. 10.1016/j.bios.2013.03.015 · DOI
  38. 10.1016/j.bios.2023.115892 · DOI
  39. 10.1016/j.snb.2022.133034 · doi:10.1016/j.snb.2022.133034
  40. 10.1016/j.coelec.2021.100757 · doi:10.1016/j.coelec.2021.100757
  41. 10.33073/pjm-2015-017 · DOI
  42. 10.1371/journal.pone.0117300 · DOI
  43. 10.1016/j.electacta.2012.05.131 · DOI
  44. 10.3390/v12040407 · DOI
  45. 10.1371/journal.pone.0163966 · DOI · Paper page
  46. 10.1007/s00284-022-02943-0 · DOI
  47. 10.1080/22221751.2021.1994355 · DOI · Paper page
  48. 10.1038/s41522-021-00236-1 · DOI · Paper page
  49. 10.1007/s00216-023-05115-6 · doi:10.1007/s00216-023-05115-6
  50. 10.1002/anie.202308181 · DOI
  51. 10.3389/fmicb.2019.00677 · DOI · Paper page
  52. 10.3390/biology10010051 · DOI · Paper page
  53. 10.3389/fcimb.2021.795797 · DOI
  54. 10.1016/S0167-7012(00)00236-0 · DOI
  55. Subramanian S, Kim YW, Meyer MT, et al. A real-time bacterial biofilm characterization platform using a microfluidic system. Techn Dig Solid-State Sens Actuat Microsyst Worksh. 2014;163–166.
  56. 10.1021/jz301053n · doi:10.1021/jz301053n
  57. 10.1063/1.4867739 · DOI
  58. 10.1039/C7AN00068E · DOI
  59. 10.1016/S0003-2670(00)82721-X · DOI
  60. 10.1021/ac961194x · doi:10.1021/ac961194x
  61. 10.1016/j.mimet.2006.01.016 · DOI
  62. 10.1159/000108321 · DOI · Paper page
  63. 10.1016/j.bios.2007.05.001 · DOI
  64. 10.1016/j.colcom.2018.11.007 · DOI
  65. 10.1016/j.bios.2008.04.011 · DOI
  66. 10.1016/j.snb.2012.01.021 · doi:10.1016/j.snb.2012.01.021
  67. 10.1016/j.sna.2015.12.001 · DOI

Cited by

See all 21

Metadata

Authors
Kulshrestha, A., & Gupta, P.
Affiliations
Department of Biotechnology
Venue
Future Microbiology
Published
2024-06-21
Volume
19
Issue
11
Pages
1003-1016
ISSN
  • 1746-0913
  • 1746-0921
Cited by
21
References
4
Language
en
Licence
doi.org/10.1080/policies-text-data-mining (tdm)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.