Intradermal vaccination using the novel microneedle device MicronJet600: Past, present, and future
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Intradermal immunization has become a forefront of vaccine improvement, both scientifically and commercially. Newer technologies are being developed to address the need to reduce the dose required for vaccination and to improve the reliability and ease of injection, which have been major hurdles in expanding the number of approved vaccines using this route of administration. In this review, 7 y of clinical experience with a novel intradermal delivery device, the MicronJet600, which is a registered hollow microneedle that simplifies the delivery of liquid vaccines, are summarized. This device has demonstrated both significant dose-sparing and superior immunogenicity in various vaccine categories, as well as in diverse subject populations and age groups. These studies have shown that intradermal delivery using this device is safe, effective, and preferred by the subjects. Comparison with other intradermal devices and potential new applications for intradermal delivery that could be pursued in the future are also discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Couzin-Frankel, J. (2013) · Science · doi:10.1126/science.342.6165.1432 · Cited by 2,051
McAllister, D. V., Wang, P. M., Davis, S. P., Park, J.-H., Canatella, P. J., Allen, M. G., & Prausnitz, M. R. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2331316100 · Cited by 859
Silicon micromachined hollow microneedles for transdermal liquid transport
Gardeniers, H. J. G. E., Luttge, R., Berenschot, E. J. W., de Boer, M. J., Yeshurun, S. Y., Hefetz, M., van-t Oever, R., & van den Berg, A. (2003) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2003.820293 · Cited by 413
Vaccines for the twenty-first century society
Rappuoli, R., Mandl, C. W., Black, S., & De Gregorio, E. (2011) · Nature Reviews Immunology · doi:10.1038/nri3085 · Cited by 388
Holland, D., Booy, R., Looze, F. D., Eizenberg, P., McDonald, J., Karrasch, J., McKeirnan, M., Salem, H., Mills, G., Reid, J., et al. (2008) · The Journal of Infectious Diseases · doi:10.1086/590434 · Cited by 254 · cited 1×
“The study, which was conducted mostly in the elderly population in Hong Kong, demonstrated 5-fold dosesparing as well, with a safety profile that was comparable to the previous study There was a similar incidence of systemic adverse events (AEs) such as fever and arthralgia, and a higher incidence of local AEs such as…”
Result
Cited by
Opportunities and challenges in the diagnostic utility of dermal interstitial fluid
Friedel, M., Thompson, I. A. P., Kasting, G., Polsky, R., Cunningham, D., Soh, H. T., & Heikenfeld, J. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00998-9 · Cited by 360
Bhatnagar, S., Dave, K., & Venuganti, V. V. K. (2017) · Journal of Controlled Release · doi:10.1016/j.jconrel.2017.05.029 · Cited by 297
Microneedles as the technique of drug delivery enhancement in diverse organs and tissues
Rzhevskiy, A. S., Singh, T. R. R., Donnelly, R. F., & Anissimov, Y. G. (2018) · Journal of Controlled Release · doi:10.1016/j.jconrel.2017.11.048 · Cited by 266
Microneedles: Characteristics, Materials, Production Methods and Commercial Development
Tucak, A., Sirbubalo, M., Hindija, L., Rahić, O., Hadžiabdić, J., Muhamedagić, K., Čekić, A., & Vranić, E. (2020) · Micromachines · doi:10.3390/mi11110961 · Cited by 231
Microneedles for painless transdermal immunotherapeutic applications
Amani, H., Shahbazi, M.-A., D'Amico, C., Fontana, F., Abbaszadeh, S., & Santos, H. A. (2021) · Journal of Controlled Release · doi:10.1016/j.jconrel.2020.12.019 · Cited by 223
Metadata
- Authors
- Levin, Y., Kochba, E., Hung, I., & Kenney, R.
- Venue
- Human Vaccines & Immunotherapeutics
- Publisher
- Informa UK Limited
- Published
- 2015-03-06
- Volume
- 11
- Issue
- 4
- Pages
- 991-997
- ISSN
- 2164-5515 (ISSN-L)
- 2164-554X
- OpenAlex
- W1795752213
- Cited by
- 108
- References
- 5
- FWCI
- 3.70
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Intradermal vaccination using the novel microneedle device MicronJet600: Past, present, and future. https://app.cochat.ai/papers/10.1080/21645515.2015.1010871
- The paper
- Levin, Y., Kochba, E., Hung, I., & Kenney, R. (2015). Intradermal vaccination using the novel microneedle device MicronJet600: Past, present, and future. Human Vaccines & Immunotherapeutics. https://doi.org/10.1080/21645515.2015.1010871
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.