The DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
Fibrin(ogen) mediates acute inflammatory responses to biomaterials.
Open accessAbstract
Although "biocompatible" polymeric elastomers are generally nontoxic, nonimmunogenic, and chemically inert, implants made of these materials may trigger acute and chronic inflammatory responses. Early interactions between implants and inflammatory cells are probably mediated by a layer of host proteins on the material surface. To evaluate the importance of this protein layer, we studied acute inflammatory responses of mice to samples of polyester terephthalate film (PET) that were implanted intraperitoneally for short periods. Material preincubated with albumin is "passivated," accumulating very few adherent neutrophils or macrophages, whereas uncoated or plasma-coated PET attracts large numbers of phagocytes. Neither IgG adsorption nor surface complement activation is necessary for this acute inflammation; phagocyte accumulation on uncoated implants is normal in hypogammaglobulinemic mice and in severely hypocomplementemic mice. Rather, spontaneous adsorption of fibrinogen appears to be critical: (a) PET coated with serum or hypofibrinogenemic plasma attracts as few phagocytes as does albumin-coated material; (b) in contrast, PET preincubated with serum or hypofibrinogenemic plasma containing physiologic amounts of fibrinogen elicits "normal" phagocyte recruitment; (c) most importantly, hypofibrinogenemic mice do not mount an inflammatory response to implanted PET unless the material is coated with fibrinogen or the animals are injected with fibrinogen before implantation. Thus, spontaneous adsorption of fibrinogen appears to initiate the acute inflammatory response to an implanted polymer, suggesting an interesting nexus between two major iatrogenic effects of biomaterials: clotting and inflammation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cytochemical Identification of Monocytes and Granulocytes
Yam, L. T., Li, C. Y., & Crosby, W. H. (1971) · American Journal of Clinical Pathology · doi:10.1093/ajcp/55.3.283 · Cited by 2,668
[57] Determination of the production of superoxide radicals and hydrogen peroxide in mitochondria
Boveris, A. (1984) · Methods in Enzymology · doi:10.1016/s0076-6879(84)05060-6 · Cited by 487
Structural changes in proteins adsorbed on polymer surfaces
Soderquist, M. E., & Walton, A. G. (1980) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(80)90463-4 · Cited by 451
Initial events in interactions of blood with a foreign surface
Baier, R. E., & Dutton, R. C. (1969) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820030115 · Cited by 448
Healing of Arterial Prostheses in Man
Berger, K., Sauvage, L. R., Rao, A. M., & Wood, S. J. (1972) · Annals of Surgery · doi:10.1097/00000658-197201000-00018 · Cited by 442
Zhao, Q., Topham, N., Anderson, J. M., Hiltner, A., Lodoen, G., & Payet, C. R. (1991) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820250205 · Cited by 318
A quick and accurate method for the determination of fibronogen in plasma.
Ellis, B., & Stransky, A. W. (1961) · PubMed · Cited by 249
Effect of albumin coating on the in vitro blood compatibility of Dacron® arterial prostheses
Kottke-Marchant, K., Anderson, J. M., Umemura, Y., & Marchant, R. E. (1989) · Biomaterials · doi:10.1016/0142-9612(89)90017-3 · Cited by 236
Senior, R. M., Skogen, W. F., Griffin, G. L., & Wilner, G. D. (1986) · Journal of Clinical Investigation · doi:10.1172/jci112353 · Cited by 225
PROLONGED COAGULATION DEFECT (DEFIBRINATION SYNDROME) IN MALAYAN VIPER BITE
Reid, H. A., Chan, K. E., & Thean, P. C. (1963) · The Lancet · doi:10.1016/s0140-6736(63)91269-8 · Cited by 215
ROLE OF THE CLOTTING SYSTEM IN CELL-MEDIATED HYPERSENSITIVITY
Colvin, R. B., Johnson, R. A., Mihm, M. C., & Dvorak, H. F. (1973) · The Journal of Experimental Medicine · doi:10.1084/jem.138.3.686 · Cited by 213
Synovial and osseous inflammation in failed silicone-rubber prostheses.
Gordon, M., & Bullough, P. G. (1982) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198264040-00013 · Cited by 213
Altieri, D. C., Agbanyo, F. R., Plescia, J., Ginsberg, M. H., Edgington, T. S., & Plow, E. F. (1990) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)38316-4 · Cited by 193
In vivo biocompatibility studies. I. The cage implant system and a biodegradable hydrogel
Marchant, R., Hiltner, A., Hamlin, C., Rabinovitch, A., Slobodkin, R., & Anderson, J. M. (1983) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820170209 · Cited by 181
Assay of the human leukocyte enzymes myeloperoxidase and eosinophil peroxidase
Bozeman, P. M., Learn, D. B., & Thomas, E. L. (1990) · Journal of Immunological Methods · doi:10.1016/0022-1759(90)90020-v · Cited by 170
Cellular interactions with biomaterials: In vivo cracking of pre‐stressed pellethane 2363‐80A
Zhao, Q., Agger, M. P., Fitzpatrick, M. N., Anderson, J. M., Hiltner, A., Stokes, K., & Urbanski, P. (1990) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820240508 · Cited by 147
Degradation of biomaterials by phagocyte-derived oxidants.
Sutherland, K., Mahoney, J. R., Coury, A. J., & Eaton, J. W. (1993) · Journal of Clinical Investigation · doi:10.1172/jci116841 · Cited by 147
Self-citationChemotaxis for Human Monocytes by Fibrinogen‐derived Peptides
Richardson, D. L., Pepper, D. S., & Kay, A. B. (1976) · British Journal of Haematology · doi:10.1111/j.1365-2141.1976.tb00953.x · Cited by 140
Purification of myeloperoxidases from bone marrow
Himmelhoch, S., Evans, W. H., Mage, M. G., & Peterson, E. A. (1969) · Biochemistry · doi:10.1021/bi00831a022 · Cited by 136
Protein Adsorption and Cellular Adhesion and Activation on Biomedical Polymers
Anderson, J. M., Bonfield, T. L., & Ziats, N. P. (1990) · The International Journal of Artificial Organs · doi:10.1177/039139889001300609 · Cited by 135
HISTOLOGICAL INVESTIGATION OF THE ETIOLOGY OF CAPSULE CONTRACTURE FOLLOWING AUGMENTATION MAMMAPLASTY
Domanskis, E. J., & Owsley, J. Q. (1976) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-197612000-00006 · Cited by 129
Oxidation of chloride and thiocyanate by isolated leukocytes.
Thomas, E. L., & Fishman, M. (1986) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)67570-2 · Cited by 127
Tang, L., Lucas, A. H., & Eaton, J. W. (1993) · PubMed · Cited by 127
Self-citationIn vivo biocompatibility studies. V. In vivo leukocyte interactions with biomer
Marchant, R. E., Miller, K. M., & Anderson, J. M. (1984) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820180917 · Cited by 117
Quantitative characterization of cells at the interface of long‐term implants of selected polymers
Behling, C. A., & Spector, M. (1986) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820200509 · Cited by 100
STUDY OF ENCAPSULATION OF SILICONE RUBBER IMPLANTS IN ANIMALS A Foreign-Body Reaction
Vistnes, L. M., Ksander, G. A., & Kosek, J. C. (1978) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-197810000-00015 · Cited by 100
Fibrinogen-derived peptide B beta 1-42 is a multidomained neutrophil chemoattractant
Skogen, W. F., Senior, R., Griffin, G., & Wilner, G. D. (1988) · Blood · doi:10.1182/blood.v71.5.1475.1475 · Cited by 98
Morphologic characteristics of adsorbed human plasma proteins on vascular grafts and biomaterials
Pankowsky, D. A., Ziats, N. P., Topham, N. S., Ratnoff, O. D., & Anderson, J. M. (1990) · Journal of Vascular Surgery · doi:10.1016/0741-5214(90)90309-x · Cited by 94
Gustafson, E. J., ŁUKASIEWICZ, H., Wachtfogel, Y. T., Norton, K. J., Schmaier, A. H., Niewiarowski, S., & Colman, R. W. (1989) · The Journal of Cell Biology · doi:10.1083/jcb.109.1.377 · Cited by 84
Hamlin, G. W., Rajah, S. M., Crow, M. J., & Kester, R. C. (1978) · British journal of surgery · doi:10.1002/bjs.1800650416 · Cited by 79
Albumin‐binding surfaces for implantable devices
Keogh, J. R., Velander, F. F., & Eaton, J. W. (1992) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820260403 · Cited by 71
Self-citationAlbumin Coating of a Knitted Polyester Arterial Prosthesis: An Alternative to Preclotting
Guidoin, R., Snyder, R., Martin, L., Botzko, K., Marois, M., Awad, J. A., King, M. W., Domurado, D., Bedros, M., & Gosselin, C. (1984) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(10)61131-9 · Cited by 70
The Chemotactic Activity of Fibrin Lysis Products
Stecher, V. J., & Sorkin, E. (2009) · International Archives of Allergy and Applied Immunology · doi:10.1159/000230905 · Cited by 64
Detection of toluenediamines in the urine of a patient with polyurethane-covered breast implants
Chan, S. C., Birdsell, D. C., & Gradeen, C. Y. (1991) · Clinical Chemistry · doi:10.1093/clinchem/37.5.756 · Cited by 62
Ratner, B. D., Castner, D. G., Horbett, T. A., Lenk, T. J., Lewis, K. B., & Rapoza, R. J. (1990) · Journal of Vacuum Science & Technology A Vacuum Surfaces and Films · doi:10.1116/1.576755 · Cited by 62
Chinn, J. A., Posso, S. E., Horbett, T. A., & Ratner, B. D. (1991) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820250410 · Cited by 62
Chinn, J. A., Posso, S. E., Horbett, T. A., & Ratner, B. D. (1992) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820260606 · Cited by 61
Picha, G. J., Goldstein, J. A., & Stöhr, E. (1990) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-199006000-00011 · Cited by 61
Marchant, R., Anderson, J. M., & Dillingham, E. (1986) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820200105 · Cited by 60
Christenson, L., Aebischer, P., McMillan, P. N., & Galletti, P. M. (1989) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820230704 · Cited by 51
Marchant, R. E., Anderson, J. M., Phua, K., & Hiltner, A. (1984) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820180307 · Cited by 47
Transient in vivo protein adsorption onto polymeric biomaterials
Ihlenfeld, J. V., & Cooper, S. L. (1979) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820130405 · Cited by 43
Peritoneal macrophage response: an in vivo model for the study of synthetic materials
Freyria, A. M., Chignier, E., Guidollet, J., & Louisot, P. (1991) · Biomaterials · doi:10.1016/0142-9612(91)90187-f · Cited by 42
Trezzini, C., Schuuepp, B., Maly, F. E., et al. (1991) · British Journal of Haematology · doi:10.1111/j.1365-2141.1991.tb07942.x · Cited by 41
Foreign material in the capsules around breast prostheses and the cellular reaction to it
Sˇmahel, J. (1979) · British Journal of Plastic Surgery · doi:10.1016/0007-1226(79)90058-4 · Cited by 41
Bell, W. R., Ss, S., Martinez, J., & Nossel, H. L. (1978) · PubMed · Cited by 39
In vivo characterization of the inflammatory properties of poly(tetrafluoroethylene) particulates
Kossovsky, N., Millett, D., Juma, S., et al. (1991) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820251009 · Cited by 37
Analysis of the Surface Morphology of Recovered Silicone Mammary Prostheses
Kossovsky, N., Heggers, J. P., Parsons, R. W., & Robson, M. C. (1983) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-198306000-00008 · Cited by 34
Behrens, B. L., Clark, R. A., Presley, D. M., et al. (1987) · PubMed · Cited by 31
Intraluminal Cyclosporine A Reduces Capsular Thickness Around Silicone Implants in Rats
Stark, G. B., Göbel, M., & Jaeger, K. B. (1990) · Annals of Plastic Surgery · doi:10.1097/00000637-199002000-00009 · Cited by 22
Physical and chemical characterization of a horse serum carboxylesterase
Torres, J. L., Rush, R. S., & Main, A. R. (1988) · Archives of Biochemistry and Biophysics · doi:10.1016/0003-9861(88)90032-x · Cited by 20
Complications from the Treatment of Fibrous Capsular Contracture of the Breast
Nelson, G. (1981) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-198112000-00027 · Cited by 19
Ward, R., & Minns, R. J. (1989) · Biomaterials · doi:10.1016/0142-9612(89)90135-x · Cited by 16
Cited by
Biological Responses to Materials
Anderson, J. M. (2001) · Annual Review of Materials Research · doi:10.1146/annurev.matsci.31.1.81 · Cited by 1,465
Gorbet, M. B., & Sefton, M. V. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2004.01.023 · Cited by 1,347
Surface Chemistry Influences Implant Biocompatibility
Tang, L., Thevenot, P., & Hu, W. (2008) · Current Topics in Medicinal Chemistry · doi:10.2174/156802608783790901 · Cited by 800
Self-citationOsteoimmunomodulation for the development of advanced bone biomaterials
Chen, Z., Klein, T., Murray, R. Z., Crawford, R., Chang, J., Wu, C., & Xiao, Y. (2016) · Materials Today · doi:10.1016/j.mattod.2015.11.004 · Cited by 730
Biomaterials: Foreign Bodies or Tuners for the Immune Response?
Mariani, E., Lisignoli, G., Borzì, R. M., & Pulsatelli, L. (2019) · International Journal of Molecular Sciences · doi:10.3390/ijms20030636 · Cited by 706
Metadata
- Authors
- Tang, L., & Eaton, J. W.
- Venue
- The Journal of experimental medicine
- Publisher
- Rockefeller University Press
- Published
- 1993-12-01
- Volume
- 178
- Issue
- 6
- Pages
- 2147-2156
- ISSN
- 0022-1007 (ISSN-L)
- 1540-9538
- OpenAlex
- W2162804001
- Cited by
- 449
- References
- 53
- FWCI
- 8.21
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.