The DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
Fibrin(ogen) mediates acute inflammatory responses to biomaterials.
Open accessAbstract
Although "biocompatible" polymeric elastomers are generally nontoxic, nonimmunogenic, and chemically inert, implants made of these materials may trigger acute and chronic inflammatory responses. Early interactions between implants and inflammatory cells are probably mediated by a layer of host proteins on the material surface. To evaluate the importance of this protein layer, we studied acute inflammatory responses of mice to samples of polyester terephthalate film (PET) that were implanted intraperitoneally for short periods. Material preincubated with albumin is "passivated," accumulating very few adherent neutrophils or macrophages, whereas uncoated or plasma-coated PET attracts large numbers of phagocytes. Neither IgG adsorption nor surface complement activation is necessary for this acute inflammation; phagocyte accumulation on uncoated implants is normal in hypogammaglobulinemic mice and in severely hypocomplementemic mice. Rather, spontaneous adsorption of fibrinogen appears to be critical: (a) PET coated with serum or hypofibrinogenemic plasma attracts as few phagocytes as does albumin-coated material; (b) in contrast, PET preincubated with serum or hypofibrinogenemic plasma containing physiologic amounts of fibrinogen elicits "normal" phagocyte recruitment; (c) most importantly, hypofibrinogenemic mice do not mount an inflammatory response to implanted PET unless the material is coated with fibrinogen or the animals are injected with fibrinogen before implantation. Thus, spontaneous adsorption of fibrinogen appears to initiate the acute inflammatory response to an implanted polymer, suggesting an interesting nexus between two major iatrogenic effects of biomaterials: clotting and inflammation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cytochemical Identification of Monocytes and Granulocytes
Yam, L. T., Li, C. Y., & Crosby, W. H. (1971) · American Journal of Clinical Pathology · doi:10.1093/ajcp/55.3.283 · Cited by 2,668
[57] Determination of the production of superoxide radicals and hydrogen peroxide in mitochondria
Boveris, A. (1984) · Methods in Enzymology · doi:10.1016/s0076-6879(84)05060-6 · Cited by 487
Structural changes in proteins adsorbed on polymer surfaces
Soderquist, M. E., & Walton, A. G. (1980) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(80)90463-4 · Cited by 451
Initial events in interactions of blood with a foreign surface
Baier, R. E., & Dutton, R. C. (1969) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820030115 · Cited by 448
Healing of Arterial Prostheses in Man
Berger, K., Sauvage, L. R., Rao, A. M., & Wood, S. J. (1972) · Annals of Surgery · doi:10.1097/00000658-197201000-00018 · Cited by 442
Zhao, Q., Topham, N., Anderson, J. M., Hiltner, A., Lodoen, G., & Payet, C. R. (1991) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820250205 · Cited by 318
A quick and accurate method for the determination of fibronogen in plasma.
Ellis, B., & Stransky, A. W. (1961) · PubMed · Cited by 249
Effect of albumin coating on the in vitro blood compatibility of Dacron® arterial prostheses
Kottke-Marchant, K., Anderson, J. M., Umemura, Y., & Marchant, R. E. (1989) · Biomaterials · doi:10.1016/0142-9612(89)90017-3 · Cited by 236
Senior, R. M., Skogen, W. F., Griffin, G. L., & Wilner, G. D. (1986) · Journal of Clinical Investigation · doi:10.1172/jci112353 · Cited by 225
PROLONGED COAGULATION DEFECT (DEFIBRINATION SYNDROME) IN MALAYAN VIPER BITE
Reid, H. A., Chan, K. E., & Thean, P. C. (1963) · The Lancet · doi:10.1016/s0140-6736(63)91269-8 · Cited by 215
Cited by
Biological Responses to Materials
Anderson, J. M. (2001) · Annual Review of Materials Research · doi:10.1146/annurev.matsci.31.1.81 · Cited by 1,465
Gorbet, M. B., & Sefton, M. V. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2004.01.023 · Cited by 1,347
Surface Chemistry Influences Implant Biocompatibility
Tang, L., Thevenot, P., & Hu, W. (2008) · Current Topics in Medicinal Chemistry · doi:10.2174/156802608783790901 · Cited by 800
Self-citationOsteoimmunomodulation for the development of advanced bone biomaterials
Chen, Z., Klein, T., Murray, R. Z., Crawford, R., Chang, J., Wu, C., & Xiao, Y. (2016) · Materials Today · doi:10.1016/j.mattod.2015.11.004 · Cited by 730
Biomaterials: Foreign Bodies or Tuners for the Immune Response?
Mariani, E., Lisignoli, G., Borzì, R. M., & Pulsatelli, L. (2019) · International Journal of Molecular Sciences · doi:10.3390/ijms20030636 · Cited by 706
Quantitative Structure–Property Relationship Modeling of Diverse Materials Properties
Le, T., Epa, V. C., Burden, F. R., & Winkler, D. A. (2012) · Chemical Reviews · doi:10.1021/cr200066h · Cited by 565
Metal ion release from metal implants
Hanawa, T. (2004) · Materials Science and Engineering: C · doi:10.1016/j.msec.2004.08.018 · Cited by 528
Engineering Immunomodulatory Biomaterials To Tune the Inflammatory Response
Vishwakarma, A., Bhise, N. S., Evangelista, M. B., Rouwkema, J., Dokmeci, M. R., Ghaemmaghami, A. M., Vrana, N. E., & Khademhosseini, A. (2016) · Trends in Biotechnology · doi:10.1016/j.tibtech.2016.03.009 · Cited by 517
Chemical modification of titanium surfaces for covalent attachment of biological molecules
Nanci, A., Wuest, J. D., Peru, L., Brunet, P., Sharma, V., Zalzal, S., & McKee, M. D. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199805)40:2<324::aid-jbm18>3.0.co;2-l · Cited by 503
Inflammatory Responses to Biomaterials
Tang, L., & Eaton, J. W. (1995) · American Journal of Clinical Pathology · doi:10.1093/ajcp/103.4.466 · Cited by 481
Self-citationComplement activation and protein adsorption by carbon nanotubes
SALVADORMORALES, C., FLAHAUT, E., SIM, E., SLOAN, J., HGREEN, M., & SIM, R. (2006) · Molecular Immunology · doi:10.1016/j.molimm.2005.02.006 · Cited by 434
Molecular basis of biomaterial-mediated foreign body reactions
Hu, W.-J., Eaton, J. W., Ugarova, T. P., & Tang, L. (2001) · Blood · doi:10.1182/blood.v98.4.1231 · Cited by 431
Self-citationResolution of spontaneous bleeding events but failure of pregnancy in fibrinogen-deficient mice.
Suh, T. T., Holmbäck, K., Jensen, N. J., Daugherty, C. C., Small, K., Simon, D. I., Potter, S., & Degen, J. L. (1995) · Genes & Development · doi:10.1101/gad.9.16.2020 · Cited by 425
Cellular and Molecular Dynamics in the Foreign Body Reaction
Luttikhuizen, D. T., Harmsen, M. C., & Luyn, M. J. A. V. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.1955 · Cited by 396
Ward, W. K. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200504 · Cited by 325
Glaucoma drainage devices: a systematic literature review and current controversies
Hong, C.-H., Arosemena, A., Zurakowski, D., & Ayyala, R. S. (2005) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2004.10.006 · Cited by 323
Roles for thrombin and fibrin(ogen) in cytokine/chemokine production and macrophage adhesion in vivo
Szaba, F. M., & Smiley, S. T. (2002) · Blood · doi:10.1182/blood.v99.3.1053 · Cited by 304
Shen, M., Martinson, L., Wagner, M. S., Castner, D. G., Ratner, B. D., & Horbett, T. A. (2002) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856202320253910 · Cited by 296
LFA-1 is sufficient in mediating neutrophil emigration in Mac-1-deficient mice.
Lu, H., Smith, C. W., Perrard, J., Bullard, D., Tang, L., Shappell, S. B., Entman, M. L., Beaudet, A. L., & Ballantyne, C. M. (1997) · Journal of Clinical Investigation · doi:10.1172/jci119293 · Cited by 282
Self-citationMast cells mediate acute inflammatory responses to implanted biomaterials
Tang, L., Jennings, T. A., & Eaton, J. W. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.15.8841 · Cited by 272
Self-citationFunctional Biomaterials for Bone Regeneration: A Lesson in Complex Biology
Armiento, A. R., Hatt, L. P., Sanchez Rosenberg, G., Thompson, K., & Stoddart, M. J. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201909874 · Cited by 273
Engineering biomaterials to integrate and heal: The biocompatibility paradigm shifts
Bryers, J. D., Giachelli, C. M., & Ratner, B. D. (2012) · Biotechnology and Bioengineering · doi:10.1002/bit.24559 · Cited by 271
Simultaneous Activation of Complement and Coagulation by MBL-Associated Serine Protease 2
Krarup, A., Wallis, R., Presanis, J. S., Gál, P., & Sim, R. B. (2007) · PLoS ONE · doi:10.1371/journal.pone.0000623 · Cited by 262
The Foreign Body Response Demystified
Chandorkar, Y., K, R., & Basu, B. (2019) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.8b00252 · Cited by 201
Integrin-directed modulation of macrophage responses to biomaterials
Zaveri, T. D., Lewis, J. S., Dolgova, N. V., Clare-Salzler, M. J., & Keselowsky, B. G. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.01.007 · Cited by 164
Zdolsek, J., Eaton, J. W., & Tang, L. (2007) · Journal of Translational Medicine · doi:10.1186/1479-5876-5-31 · Cited by 154
Self-citationRole of plasma fibronectin in the foreign body response to biomaterials
Keselowsky, B. G., Bridges, A. W., Burns, K. L., Tate, C. C., Babensee, J. E., LaPlaca, M. C., & García, A. J. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.04.035 · Cited by 130
Fibrinogen inhibits neurite outgrowth via β3 integrin-mediated phosphorylation of the EGF receptor
Schachtrup, C., Lu, P., Jones, L. L., Lee, J. K., Lu, J., Sachs, B. D., Zheng, B., & Akassoglou, K. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0704045104 · Cited by 117
Brodbeck, W. G., Colton, E., & Anderson, J. M. (2003) · Journal of Materials Science Materials in Medicine · doi:10.1023/a:1024951330265 · Cited by 65
Long-term biocompatibility of a miniature stimulator implanted in feline hind limb muscles
Cameron, T., Liinamaa, T. L., Loeb, G. E., & Richmond, F. J. R. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.704871 · Cited by 53
Biocompatibility and Bioresponse to Biomaterials
Anderson, J. M. (2019) · Principles of Regenerative Medicine · doi:10.1016/b978-0-12-809880-6.00039-4 · Cited by 33
In Vivo Evaluation of the Biocompatibility of Biomaterial Device
Frazão, L. P., Vieira de Castro, J., & Neves, N. M. (2020) · Advances in Experimental Medicine and Biology · doi:10.1007/978-981-15-3262-7_8 · Cited by 23
Metadata
- Authors
- Tang, L., & Eaton, J. W.
- Venue
- The Journal of experimental medicine
- Publisher
- Rockefeller University Press
- Published
- 1993-12-01
- Volume
- 178
- Issue
- 6
- Pages
- 2147-2156
- ISSN
- 0022-1007 (ISSN-L)
- 1540-9538
- OpenAlex
- W2162804001
- Cited by
- 449
- References
- 53
- FWCI
- 8.21
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.