Transient hot-strip method for simultaneously measuring thermal conductivity and thermal diffusivity of solids and fluids
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
A transient hot-strip method has been developed for use with solids and fluids with low electrical conductivity. The hot strip (thin metal foil) is used both as a constant plane heat source and a sensor of the temperature increase. The accuracy of the method is so good that it might even be used for the measurement of the specific heat especially under difficult experimental conditions when the standard methods cannot be used or would be very inconvenient. This method has been tested in measurements on fused quartz, glycerine and Araldite at room temperature. The experimental conditions that cause deviations from the mathematical solution of the thermal conductivity equation are discussed and estimates for their maximum influence on the measured quantities are given.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thermal conductivity of selected materials
Powell, R. W., Ho, C. Y., & Liley, P. E. (1966) · doi:10.6028/nbs.nsrds.8 · Cited by 426
Thermal conductivity of solids at room temperature and below :
Childs, G. E., Ericks, L. J., & Powell, R. L. (1973) · doi:10.6028/nbs.mono.131 · Cited by 117
A Non-Steady-State Method of Measuring the Thermal Conductivity of Transparent Liquids
Gustafsson, S. E. (1967) · Zeitschrift für Naturforschung A · doi:10.1515/zna-1967-0704 · Cited by 42
Self-citationMcLaughlin, E., & Pittman, J. F. T. (1971) · Philosophical Transactions of the Royal Society of London Series A Mathematical and Physical Sciences · doi:10.1098/rsta.1971.0089 · Cited by 23
New measurements and a discussion of existing data
McLaughlin, E., & Pittman, J. F. T. (1971) · Philosophical Transactions of the Royal Society of London Series A Mathematical and Physical Sciences · doi:10.1098/rsta.1971.0090 · Cited by 13
New method for measuring thermal properties of transparent solids
Gustafsson, S. E., Hamdani, A. J., & Karawacki, E. (1979) · Journal of Physics E Scientific Instruments · doi:10.1088/0022-3735/12/5/015 · Cited by 11
Self-citation
Cited by
Gustafsson, S. E. (1991) · Review of Scientific Instruments · doi:10.1063/1.1142087 · Cited by 1,691
Self-citationQiu, L., Zhu, N., Feng, Y., Michaelides, E. E., Żyła, G., Jing, D., Zhang, X., Norris, P. M., Markides, C. N., & Mahian, O. (2020) · Physics Reports · doi:10.1016/j.physrep.2019.12.001 · Cited by 523
Rapid thermal conductivity measurement with a hot disk sensor
He, Y. (2005) · Thermochimica Acta · doi:10.1016/j.tca.2005.06.026 · Cited by 459
Thermal conductivities study on silica aerogel and its composite insulation materials
Wei, G., Liu, Y., Zhang, X., Yu, F., & Du, X. (2011) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2011.02.026 · Cited by 457
Review on using microencapsulated phase change materials (PCM) in building applications
Konuklu, Y., Ostry, M., Paksoy, H. O., & Charvat, P. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2015.07.019 · Cited by 430
Wei, G., Wang, G., Xu, C., Ju, X., Xing, L., Du, X., & Yang, Y. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.05.271 · Cited by 395
Said, Z., Sundar, L. S., Tiwari, A. K., Ali, H. M., Sheikholeslami, M., Bellos, E., & Babar, H. (2022) · Physics Reports · doi:10.1016/j.physrep.2021.07.002 · Cited by 391
Gustavsson, M., Karawacki, E., & Gustafsson, S. E. (1994) · Review of Scientific Instruments · doi:10.1063/1.1145178 · Cited by 385
Self-citationLog, T., & Gustafsson, S. E. (1995) · Fire and Materials · doi:10.1002/fam.810190107 · Cited by 357
Self-citationImproving thermal conductivity phase change materials—A study of paraffin nanomagnetite composites
Şahan, N., Fois, M., & Paksoy, H. (2015) · Solar Energy Materials and Solar Cells · doi:10.1016/j.solmat.2015.01.027 · Cited by 292
Estimation of Equivalent Thermal Parameters of Impregnated Electrical Windings
Simpson, N., Wrobel, R., & Mellor, P. H. (2013) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2013.2263271 · Cited by 291
Heat capacity, thermal conductivity, and thermal expansion of barium titanate-based ceramics
He, Y. (2004) · Thermochimica Acta · doi:10.1016/j.tca.2004.02.008 · Cited by 265
Spray freeze-dried nanofibrillated cellulose aerogels with thermal superinsulating properties
Jiménez-Saelices, C., Seantier, B., Cathala, B., & Grohens, Y. (2017) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2016.09.068 · Cited by 219
“This device, adapted from the hot filament technique, has been previously developed for thermal characterization of aerogels (Bendahou et al., 2015; Gustafsson, Karawacki & Khan, 1979).”
MethodYüksel, N. (2016) · Insulation Materials in Context of Sustainability · doi:10.5772/64157 · Cited by 143
“Another use of the method is a steady‐state pipe method having a cylindrical specimen geometry and containing radial heat‐flow measurements [7, 21, 22].”
Bouguerra, A., Aït-Mokhtar, A., Amiri, O., & Diop, M. B. (2001) · International Communications in Heat and Mass Transfer · doi:10.1016/s0735-1933(01)00310-4 · Cited by 133
Ahadi, M., Andisheh-Tadbir, M., Tam, M., & Bahrami, M. (2016) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2016.01.037 · Cited by 76
“Hot strip Capable of measuring thermal conductivity, thermal diffusivity, and specific heat [14] Suitable for solids and fluids with low electrical conductivity [14] Long sensors and, consequently, long samples Not available”
BackgroundZhang, H., Jin, Y., Gu, W., Li, Z. Y., & Tao, W. Q. (2013) · Progress in Computational Fluid Dynamics, An International Journal · doi:10.1504/pcfd.2013.053660 · Cited by 50
Textural and Thermal Conductivity Properties of a Low Density Mesoporous Silica Material
Afriyie, E. T., Karami, P., Norberg, P., & Gudmundsson, K. (2014) · Energy and Buildings · doi:10.1016/j.enbuild.2014.02.012 · Cited by 28
Gaseous Conductivity Study on Silica Aerogel and Its Composite Insulation Materials
Wei, G., Liu, Y., Du, X., & Zhang, X. (2012) · Journal of Heat Transfer · doi:10.1115/1.4004170 · Cited by 26
Karami, P., Afriyie, E. T., Norberg, P., & Gudmundsson, K. (2014) · Energy and Buildings · doi:10.1016/j.enbuild.2014.09.038 · Cited by 19
Metadata
- Authors
- Gustafsson, S. E., Karawacki, E., & Khan, M. N.
- Venue
- Journal of Physics D: Applied Physics
- Publisher
- IOP Publishing
- Published
- 1979-09-14
- Volume
- 12
- Issue
- 9
- Pages
- 1411-1421
- ISSN
- 0022-3727 (ISSN-L)
- 1361-6463
- OpenAlex
- W2151590871
- Cited by
- 343
- References
- 6
- FWCI
- 3.41
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.