Single cell dielectric spectroscopy
The DOI matches its Crossref record; 54 of the 54 references it cites were found in a registry or an index.
Abstract
Over the last century a number of techniques have been developed which allow the measurement of the dielectric properties of biological particles in fluid suspension. The majority of these techniques are limited by the fact that they only provide an average value for the dielectric properties of a collection of particles. More recently, with the advent of microfabrication techniques and the Lab-on-a-chip, it has been possible to perform dielectric spectroscopic experiments on single biological particles suspended in physiological media. In this paper we review current methods for single cell dielectric spectroscopy. We also discuss alternative single cell dielectric measurement techniques, specifically the ac electrokinetic methods of dielectrophoresis and electrorotation. Single cell electrical impedance spectroscopy is also discussed with relevance to a microfabricated flow cytometer. We compare impedance spectroscopy data obtained from measurements made using a microfabricated flow cytometer with simulation data obtained using an equivalent circuit model for the device.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A treatise on electricity and magnetism
(1954) · Journal of the Franklin Institute · doi:10.1016/0016-0032(54)90053-8 · Cited by 9,077
Jones, T. B. (1995) · doi:10.1017/cbo9780511574498 · Cited by 2,786
Electrical Properties of Tissue and Cell Suspensions
Schwan, H. P. (1957) · Advances in Biological and Medical Physics · doi:10.1016/b978-1-4832-3111-2.50008-0 · Cited by 1,620
Dielectric properties of tissues and biological materials: a critical review.
Foster, K. R., & Schwan, H. P. (1989) · PubMed · Cited by 1,503
Ac electrokinetics: a review of forces in microelectrode structures
Ramos, A., Morgan, H., Green, N. G., & Castellanos, A. (1998) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/31/18/021 · Cited by 1,233
Self-citationAC electrokinetics : colloids and nanoparticles
Morgan, H., & Green, N. G. (2002) · Thammasat University Digital Collections · Cited by 1,032
Self-citationFricke, H. (1924) · Physical Review · doi:10.1103/physrev.24.575 · Cited by 908
Particle separation by dielectrophoresis
Gascoyne, P. R. C., & Vykoukal, J. (2002) · ELECTROPHORESIS · doi:10.1002/1522-2683(200207)23:13<1973::aid-elps1973>3.0.co;2-1 · Cited by 826
Pethig, R., & Kell, D. B. (1987) · Physics in Medicine and Biology · doi:10.1088/0031-9155/32/8/001 · Cited by 796
Separation of human breast cancer cells from blood by differential dielectric affinity.
Becker, F. F., Wang, X. B., Huang, Y., Pethig, R., Vykoukal, J., & Gascoyne, P. R. (1995) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.92.3.860 · Cited by 680
Cited by
Single-cell microfluidic impedance cytometry: a review
Sun, T., & Morgan, H. (2010) · Microfluidics and Nanofluidics · doi:10.1007/s10404-010-0580-9 · Cited by 576
Self-citationA review of impedance measurements of whole cells
Xu, Y., Xie, X., Duan, Y., Wang, L., Cheng, Z., & Cheng, J. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.10.027 · Cited by 424
Leukocyte analysis and differentiation using high speed microfluidic single cell impedance cytometry
Holmes, D., Pettigrew, D., Reccius, C. H., Gwyer, J. D., van Berkel, C., Holloway, J., Davies, D. E., & Morgan, H. (2009) · Lab on a Chip · doi:10.1039/b910053a · Cited by 408
Self-citationMicrofluidic approaches for cancer cell detection, characterization, and separation
Chen, J., Li, J., & Sun, Y. (2012) · Lab on a Chip · doi:10.1039/c2lc21273k · Cited by 301
Selective isolation of live/dead cells using contactless dielectrophoresis (cDEP)
Shafiee, H., Sano, M. B., Henslee, E. A., Caldwell, J. L., & Davalos, R. V. (2010) · Lab on a Chip · doi:10.1039/b920590j · Cited by 288
Recent advances in microfluidic techniques for single-cell biophysical characterization
Zheng, Y., Nguyen, J., Wei, Y., & Sun, Y. (2013) · Lab on a Chip · doi:10.1039/c3lc50355k · Cited by 267
Chen, J., Zheng, Y., Tan, Q., Shojaei-Baghini, E., Zhang, Y. L., Li, J., Prasad, P., You, L., Wu, X. Y., & Sun, Y. (2011) · Lab on a Chip · doi:10.1039/c1lc20473d · Cited by 197
A fast impedance-based antimicrobial susceptibility test
Spencer, D. C., Paton, T. F., Mulroney, K. T., Inglis, T. J. J., Sutton, J. M., & Morgan, H. (2020) · Nature Communications · doi:10.1038/s41467-020-18902-x · Cited by 183
Self-citationChen, J., Xue, C., Zhao, Y., Chen, D., Wu, M.-H., & Wang, J. (2015) · International Journal of Molecular Sciences · doi:10.3390/ijms16059804 · Cited by 160
“, membrane capacitance or cytoplasm resistance) can be utilized as cellular biophysical markers to evaluate cellular status in a label-free manner [1,2].”
BackgroundDual-frequency impedance assays for intracellular components in microalgal cells
Tang, T., Liu, X., Yuan, Y., Kiya, R., Shen, Y., Zhang, T., Suzuki, K., Tanaka, Y., Li, M., Hosokawa, Y., et al. (2022) · Lab on a Chip · doi:10.1039/d1lc00721a · Cited by 26
Lei, K. F., Wu, M.-H., Hsu, C.-W., & Chen, Y.-D. (2012) · International Journal of Electrochemical Science · doi:10.1016/s1452-3981(23)16588-6 · Cited by 12
Metadata
- Authors
- Morgan, H., Sun, T., Holmes, D., Gawad, S., & Green, N. G.
- Venue
- Journal of Physics D: Applied Physics
- Publisher
- IOP Publishing
- Published
- 2006-12-15
- Volume
- 40
- Issue
- 1
- Pages
- 61-70
- ISSN
- 0022-3727 (ISSN-L)
- 1361-6463
- OpenAlex
- W1977248858
- Cited by
- 445
- References
- 54
- FWCI
- 9.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.