The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
On the reliable measurement of specific absorption rates and intrinsic loss parameters in magnetic hyperthermia materials
Abstract
In the clinical application of magnetic hyperthermia, the heat generated by magnetic nanoparticles in an alternating magnetic field is used as a cancer treatment. The heating ability of the particles is quantified by the specific absorption rate (SAR), an extrinsic parameter based on the clinical response characteristic of power delivered per unit mass, and by the intrinsic loss parameter (ILP), an intrinsic parameter based on the heating capacity of the material. Even though both the SAR and ILP are widely used as comparative design parameters, they are almost always measured in non-adiabatic systems that make accurate measurements difficult. We present here the results of a systematic review of measurement methods for both SAR and ILP, leading to recommendations for a standardised, simple and reliable method for measurements using non-adiabatic systems. In a representative survey of 50 retrieved datasets taken from published papers, the derived SAR or ILP was found to be more than 5% overestimated in 24% of cases and more than 5% underestimated in 52% of cases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Magnetic fluid hyperthermia: focus on superparamagnetic iron oxide nanoparticles
Laurent, S., Dutz, S., Häfeli, U. O., & Mahmoudi, M. (2011) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2011.04.003 · Cited by 1,326
Clinical applications of magnetic nanoparticles for hyperthermia
Thiesen, B., & Jordan, A. (2008) · International Journal of Hyperthermia · doi:10.1080/02656730802104757 · Cited by 829
Cited by
Fundamentals and advances in magnetic hyperthermia
Périgo, E. A., Hemery, G., Sandre, O., Ortega, D., Garaio, E., Plazaola, F., & Teran, F. J. (2015) · Applied Physics Reviews · doi:10.1063/1.4935688 · Cited by 836
Unni, M., Uhl, A. M., Savliwala, S., Savitzky, B. H., Dhavalikar, R., Garraud, N., Arnold, D. P., Kourkoutis, L. F., Andrew, J. S., & Rinaldi, C. (2017) · ACS Nano · doi:10.1021/acsnano.7b00609 · Cited by 411
Blanco-Andujar, C., Ortega, D., Southern, P., Pankhurst, Q. A., & Thanh, N. T. K. (2015) · Nanoscale · doi:10.1039/c4nr06239f · Cited by 256
Self-citationNanowarming using Au-tipped Co 35 Fe 65 ferromagnetic nanowires
Shore, D., Ghemes, A., Dragos-Pinzaru, O., Gao, Z., Shao, Q., Sharma, A., Um, J., Tabakovic, I., Bischof, J. C., & Stadler, B. J. H. (2019) · Nanoscale · doi:10.1039/c9nr01182j · Cited by 42
The impact of data selection and fitting on SAR estimation for magnetic nanoparticle heating
Ring, H. L., Sharma, A., Ivkov, R., & Bischof, J. C. (2020) · International Journal of Hyperthermia · doi:10.1080/02656736.2020.1810332 · Cited by 40
Metadata
- Authors
- Wildeboer, R. R., Southern, P., & Pankhurst, Q. A.
- Venue
- Journal of Physics D: Applied Physics
- Publisher
- IOP Publishing
- Published
- 2014-11-17
- Volume
- 47
- Issue
- 49
- Pages
- 495003
- ISSN
- 0022-3727 (ISSN-L)
- 1361-6463
- OpenAlex
- W2030266047
- Cited by
- 392
- References
- 2
- FWCI
- 9.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: On the reliable measurement of specific absorption rates and intrinsic loss parameters in magnetic hyperthermia materials. https://app.cochat.ai/papers/10.1088/0022-3727/47/49/495003
- The paper
- Wildeboer, R. R., Southern, P., & Pankhurst, Q. A. (2014). On the reliable measurement of specific absorption rates and intrinsic loss parameters in magnetic hyperthermia materials. Journal of Physics D: Applied Physics. https://doi.org/10.1088/0022-3727/47/49/495003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.