On the reliable measurement of specific absorption rates and intrinsic loss parameters in magnetic hyperthermia materials
The DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.
Abstract
In the clinical application of magnetic hyperthermia, the heat generated by magnetic nanoparticles in an alternating magnetic field is used as a cancer treatment. The heating ability of the particles is quantified by the specific absorption rate (SAR), an extrinsic parameter based on the clinical response characteristic of power delivered per unit mass, and by the intrinsic loss parameter (ILP), an intrinsic parameter based on the heating capacity of the material. Even though both the SAR and ILP are widely used as comparative design parameters, they are almost always measured in non-adiabatic systems that make accurate measurements difficult. We present here the results of a systematic review of measurement methods for both SAR and ILP, leading to recommendations for a standardised, simple and reliable method for measurements using non-adiabatic systems. In a representative survey of 50 retrieved datasets taken from published papers, the derived SAR or ILP was found to be more than 5% overestimated in 24% of cases and more than 5% underestimated in 52% of cases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fundamentals of heat and mass transfer
Hewitt, G. F. (2008) · Begellhouse eBooks · Cited by 12,932
Applications of magnetic nanoparticles in biomedicine
Pankhurst, Q. A., Connolly, J., Jones, S. K., & Dobson, J. (2003) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/36/13/201 · Cited by 5,881
Self-citationProcessing technologies for poly(lactic acid)
Lim, L.-T., Auras, R., & Rubino, M. (2008) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2008.05.004 · Cited by 2,766
Applications of Magnetic Nanoparticles in Biomedicine
Bárcena, C., Sra, A. K., & Gao, J. (2009) · Nanoscale Magnetic Materials and Applications · doi:10.1007/978-0-387-85600-1_20 · Cited by 2,565
Heating magnetic fluid with alternating magnetic field
Rosensweig, R. E. (2002) · Journal of Magnetism and Magnetic Materials · doi:10.1016/s0304-8853(02)00706-0 · Cited by 2,551
Transport properties of two finite armchair graphene nanoribbons
Rosales, L., & González, J. W. (2013) · Nanoscale Research Letters · doi:10.1186/1556-276x-8-1 · Cited by 1,956
Progress in applications of magnetic nanoparticles in biomedicine
Pankhurst, Q. A., Thanh, N. T. K., Jones, S. K., & Dobson, J. (2009) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/42/22/224001 · Cited by 1,455
Self-citationMagnetic fluid hyperthermia: focus on superparamagnetic iron oxide nanoparticles
Laurent, S., Dutz, S., Häfeli, U. O., & Mahmoudi, M. (2011) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2011.04.003 · Cited by 1,326
Selective Inductive Heating of Lymph Nodes
GILCHRIST, R. K., MEDAL, R., SHOREY, W. D., HANSELMAN, R. C., PARROTT, J. C., & TAYLOR, C. B. (1957) · Annals of Surgery · doi:10.1097/00000658-195710000-00007 · Cited by 1,091
Clinical applications of magnetic nanoparticles for hyperthermia
Thiesen, B., & Jordan, A. (2008) · International Journal of Hyperthermia · doi:10.1080/02656730802104757 · Cited by 829 · cited 1×
“However, over the last decade interest has been dramatically fuelled by the achievements of Jordan et al in bringing the technology into clinical trials for brain cancer and prostate cancer [7, 8].”
BackgroundJohannsen, M., Gneveckow, U., Eckelt, L., Feussner, A., WaldÖFner, N., Scholz, R., Deger, S., Wust, P., Loening, S. A., & Jordan, A. (2005) · International Journal of Hyperthermia · doi:10.1080/02656730500158360 · Cited by 798
DESIGN OF EXPERIMENTS IN NON-LINEAR SITUATIONS
BOX, G. E. P., & LUCAS, H. L. (1959) · Biometrika · doi:10.1093/biomet/46.1-2.77 · Cited by 738
Jordan, A., Wust, P., Fählin, H., John, W., Hinz, A., & Felix, R. (1993) · International Journal of Hyperthermia · doi:10.3109/02656739309061478 · Cited by 694
Reimer, P., & Balzer, T. (2003) · European Radiology · doi:10.1007/s00330-002-1721-7 · Cited by 614
Magnetic nanoparticle design for medical applications
Mornet, S., Vasseur, S., Grasset, F., Veverka, P., Goglio, G., Demourgues, A., Portier, J., Pollert, E., & Duguet, E. (2006) · Progress in Solid State Chemistry · doi:10.1016/j.progsolidstchem.2005.11.010 · Cited by 546
Dutz, S., & Hergt, R. (2013) · International Journal of Hyperthermia · doi:10.3109/02656736.2013.822993 · Cited by 522
Size dependence of specific power absorption of Fe3O4 particles in AC magnetic field
Ma, M., Wu, Y., Zhou, J., Sun, Y., Zhang, Y., & Gu, N. (2004) · Journal of Magnetism and Magnetic Materials · doi:10.1016/s0304-8853(03)00426-8 · Cited by 497
Usable Frequencies in Hyperthermia with Thermal Seeds
Atkinson, W. J., Brezovich, I. A., & Chakraborty, D. P. (1984) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1984.325372 · Cited by 496
Suitability of commercial colloids for magnetic hyperthermia
Kallumadil, M., Tada, M., Nakagawa, T., Abe, M., Southern, P., & Pankhurst, Q. A. (2009) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2009.02.075 · Cited by 481
Self-citationLartigue, L., Hugounenq, P., Alloyeau, D., Clarke, S. P., Lévy, M., Bacri, J.-C., Bazzi, R., Brougham, D. F., Wilhelm, C., & Gazeau, F. (2012) · ACS Nano · doi:10.1021/nn304477s · Cited by 421
Weidenfeller, B., Höfer, M., & Schilling, F. R. (2004) · Composites Part A: Applied Science and Manufacturing · doi:10.1016/j.compositesa.2003.11.005 · Cited by 420
Mehdaoui, B., Meffre, A., Carrey, J., Lachaize, S., Lacroix, L., Gougeon, M., Chaudret, B., & Respaud, M. (2011) · Advanced Functional Materials · doi:10.1002/adfm.201101243 · Cited by 389
Application of magnetite ferrofluids for hyperthermia
Hiergeist, R., Andrä, W., Buske, N., Hergt, R., Hilger, I., Richter, U., & Kaiser, W. (1999) · Journal of Magnetism and Magnetic Materials · doi:10.1016/s0304-8853(99)00145-6 · Cited by 385
Magnetic Nanoparticles for Cancer Therapy
Goya, G. F., Grazu, V., & Ibarra, M. R. (2008) · Current Nanoscience · doi:10.2174/157341308783591861 · Cited by 281
Salloum, M., Ma, R. H., Weeks, D., & Zhu, L. (2008) · International Journal of Hyperthermia · doi:10.1080/02656730801907937 · Cited by 229
Heat dissipation mechanism of magnetite nanoparticles in magnetic fluid hyperthermia
Suto, M., Hirota, Y., Mamiya, H., Fujita, A., Kasuya, R., Tohji, K., & Jeyadevan, B. (2009) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2009.02.070 · Cited by 207
Photodynamic therapy induced vascular damage: an overview of experimental PDT
Wang, W., Moriyama, L. T., & Bagnato, V. S. (2013) · Laser Physics Letters · doi:10.1088/1612-2011/10/2/023001 · Cited by 186
Lartigue, L., Wilhelm, C., Servais, J., Factor, C., Dencausse, A., Bacri, J.-C., Luciani, N., & Gazeau, F. (2012) · ACS Nano · doi:10.1021/nn300060u · Cited by 173
Use of magnetic nanoparticle heating in the treatment of breast cancer
Hilger, I., Hergt, R., & Kaiser, W. A. (2005) · IEE Proceedings - Nanobiotechnology · doi:10.1049/ip-nbt:20055018 · Cited by 170
Gd-doped iron-oxide nanoparticles for tumour therapy via magnetic field hyperthermia
Drake, P. L., Cho, H.-J., Shih, P.-S., Kao, C., Lee, K.-F., Kuo, C.-H., Lin, X., & Lin, Y.-J. (2007) · Journal of Materials Chemistry · doi:10.1039/b711962c · Cited by 166
Heating Potential of Iron Oxides for Therapeutic Purposes in Interventional Radiology
Hilger, I., Frühauf, K., Andrä, W., Hiergeist, R., Hergt, R., & Kaiser, W. A. (2002) · Academic Radiology · doi:10.1016/s1076-6332(03)80171-x · Cited by 160
Jordan, A., Wust, P., Fähling, H., John, W., Hinz, A., & Felix, R. (2009) · International Journal of Hyperthermia · doi:10.3109/02656730903287790 · Cited by 158
Induction heating studies of dextran coated MgFe 2 O 4 nanoparticles for magnetic hyperthermia
Khot, V. M., Salunkhe, A. B., Thorat, N. D., Ningthoujam, R. S., & Pawar, S. H. (2012) · Dalton Transactions · doi:10.1039/c2dt31114c · Cited by 151
Bordelon, D. E., Cornejo, C., Grüttner, C., Westphal, F., DeWeese, T. L., & Ivkov, R. (2011) · Journal of Applied Physics · doi:10.1063/1.3597820 · Cited by 142
Patil, R. M., Shete, P. B., Thorat, N. D., Otari, S. V., Barick, K. C., Prasad, A. K., Ningthoujam, R. S., Tiwale, B. M., & Pawar, S. H. (2013) · RSC Advances · doi:10.1039/c3ra44644a · Cited by 117
Magnetic nanoparticle-loaded polymer nanospheres as magnetic hyperthermia agents
Liu, X., Choo, E. S. G., Ahmed, A. S., Zhao, L., Yang, Y., Ramanujan, R. V., Xue, J. M., Fan, D. D., Fan, H. M., & Ding, J. (2013) · Journal of Materials Chemistry B · doi:10.1039/c3tb21146k · Cited by 109
Marcos-Campos, I., Asín, L., Torres, T. E., Marquina, C., Tres, A., Ibarra, M. R., & Goya, G. F. (2011) · Nanotechnology · doi:10.1088/0957-4484/22/20/205101 · Cited by 87
Integrated genetic analysis microsystems
Lagally, E. T., & Mathies, R. A. (2004) · Journal of Physics D Applied Physics · doi:10.1088/0022-3727/37/23/r01 · Cited by 85
Adiabatic vs. non-adiabatic determination of specific absorption rate of ferrofluids
Natividad, E., Castro, M., & Mediano, A. (2009) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2009.02.072 · Cited by 82
Accurate measurement of the specific absorption rate using a suitable adiabatic magnetothermal setup
Natividad, E., Castro, M., & Mediano, A. (2008) · Applied Physics Letters · doi:10.1063/1.2891084 · Cited by 82
Wang, S., Huang, S., & Borca‐Tasciuc, D. (2012) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2012.2224648 · Cited by 80
Bordelon, D. E., Goldstein, R. C., Nemkov, V. S., Kumar, A., Jackowski, J. K., DeWeese, T. L., & Ivkov, R. (2012) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2011.2162527 · Cited by 78
Huang, S., Wang, S. Y., Gupta, A. K., Borca-Tasciuc, D.-A., & Salon, S. J. (2012) · Measurement Science and Technology · doi:10.1088/0957-0233/23/3/035701 · Cited by 73
Terán, F. J., Casado, C., Mikuszeit, N., Salas, G., Bollero, A., Morales, M. P., Camarero, J., & Miranda, R. (2012) · Applied Physics Letters · doi:10.1063/1.4742918 · Cited by 64
Kline, T. L., Xu, Y.-H., Jing, Y., & Wang, J. (2009) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2009.02.079 · Cited by 63
Size dependent heat generation of magnetite nanoparticles under AC magnetic field for cancer therapy
Motoyama, J., Hakata, T., Kato, R., YAMASHITA, N., Morino, T., Kobayashi, T., & Honda, H. (2008) · BioMagnetic Research and Technology · doi:10.1186/1477-044x-6-4 · Cited by 57
Renard, P. L., Lortz, R., Senatore, C., Rapin, J., Buchegger, F., Petri‐Fink, A., Hofmann, H., Doelker, É., & Jordan, O. (2010) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2010.12.003 · Cited by 55
Size dependence of the magnetic relaxation and specific power absorption in iron oxide nanoparticles
Lima, E., Torres, T. E., Rossi, L. M., Rechenberg, H. R., Berquó, T. S., Ibarra, A., Marquina, C., Ibarra, M. R., & Goya, G. F. (2013) · Journal of Nanoparticle Research · doi:10.1007/s11051-013-1654-x · Cited by 54
Magnetic properties and heating effect in bacterial magnetic nanoparticles
Timko, M., Džarová, A., Kovac, J., Skumiel, A., Józefczak, A., Hornowski, T., Gojżewski, H., Závišová, V., Koneracká, M., Šprincová, A., et al. (2009) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2009.02.077 · Cited by 53
Jordan, A. (2009) · International Journal of Hyperthermia · doi:10.3109/02656730903183445 · Cited by 37
Yuan, Y., & Borca‐Tasciuc, D. (2011) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2011.05.018 · Cited by 31
Biomedical and environmental applications of magnetic nanoparticles
Tran, D. L., Le, V. H., Pham, H. L., Hoang, T. M. N., Nguyen, T. Q., Luong, T. T., Ha, P. T., & Nguyen, X. P. (2010) · Advances in Natural Sciences Nanoscience and Nanotechnology · doi:10.1088/2043-6262/1/4/045013 · Cited by 31
Araya, T., Kasahara, Nishikawa, Kimura, Sone, Nagae, Ikehata, Nagano, & Fujimura, F. (2013) · OncoTargets and Therapy · doi:10.2147/ott.s42815 · Cited by 30
Iron oxide-based conjugates for cancer theragnostics
Nguyen, X. P., Tran, D. L., Ha, P. T., Pham, H. N., Mai, T. T., Pham, H. L., Le, V. H., Manh, D. H., Phan, T. B. H., Phạm, T. H. G., et al. (2012) · Advances in Natural Sciences Nanoscience and Nanotechnology · doi:10.1088/2043-6262/3/3/033001 · Cited by 20
Aono, H., 江原弘規, Senba, R., Naohara, T., Maehara, T., Hirazawa, H., & Watanabe, Y. (2012) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2012.02.002 · Cited by 15
Ishihara, Y., Honma, T., Nohara, S., & Ito, Y. (2013) · BMC Medical Imaging · doi:10.1186/1471-2342-13-15 · Cited by 13
Cited by
Fundamentals and advances in magnetic hyperthermia
Périgo, E. A., Hemery, G., Sandre, O., Ortega, D., Garaio, E., Plazaola, F., & Teran, F. J. (2015) · Applied Physics Reviews · doi:10.1063/1.4935688 · Cited by 836
Advances in Magnetic Nanoparticles for Biomedical Applications
Cardoso, V. F., Francesko, A., Ribeiro, C., Bañobre‐López, M., Martins, P., & Lanceros‐Mendez, S. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700845 · Cited by 723
Magnetic Properties of Magnetic Nanoparticles for Efficient Hyperthermia
Obaidat, I., Issa, B., & Haik, Y. (2015) · Nanomaterials · doi:10.3390/nano5010063 · Cited by 495
Biologically Targeted Magnetic Hyperthermia: Potential and Limitations
Chang, D., Lim, M., Goos, J. A. C. M., Qiao, R., Ng, Y. Y., Mansfeld, F. M., Jackson, M., Davis, T. P., & Kavallaris, M. (2018) · Frontiers in Pharmacology · doi:10.3389/fphar.2018.00831 · Cited by 495
Unni, M., Uhl, A. M., Savliwala, S., Savitzky, B. H., Dhavalikar, R., Garraud, N., Arnold, D. P., Kourkoutis, L. F., Andrew, J. S., & Rinaldi, C. (2017) · ACS Nano · doi:10.1021/acsnano.7b00609 · Cited by 411
Metadata
- Authors
- Wildeboer, R. R., Southern, P., & Pankhurst, Q. A.
- Venue
- Journal of Physics D: Applied Physics
- Publisher
- IOP Publishing
- Published
- 2014-11-17
- Volume
- 47
- Issue
- 49
- Pages
- 495003
- ISSN
- 0022-3727 (ISSN-L)
- 1361-6463
- OpenAlex
- W2030266047
- Cited by
- 392
- References
- 56
- FWCI
- 9.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.