NIST-F1: recent improvements and accuracy evaluations
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
In the last several years we have made many improvements to NIST-F1 (a laser-cooled Cs fountain primary frequency standard at the National Institute of Standards and Technology (NIST) in Boulder, Colorado) resulting in a reduction by over a factor of 2 in the uncertainty of the realization of the SI second. The two most recent accuracy evaluations of NIST-F1 had combined standard fractional uncertainties of 0.61 × 10 −15 (June 2004) and 0.53 × 10 −15 (January 2005), which were submitted to the Bureau International des Poids et Mesures with total fractional uncertainties (including time-transfer contributions) of, respectively, 0.88 × 10 −15 and 0.97 × 10 −15 . Here we discuss the improvements and evaluation methods and present an updated uncertainty budget.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Atomic clocks with the stability level of 10 -16 have been created [19][20][21].”
From Determination of the geopotential and orthometric height based on frequency shift equation (2011) · cites this paper as [19]
Citations
Cites
Guidelines for evaluating and expressing the uncertainty of NIST measurement results
Taylor, B. N., & Kuyatt, C. E. (2018) · doi:10.6028/nist.tn.1297-1993 · Cited by 2,582 · cited 1×
“However, Type A and Type B refer to the methods used to measure the physical quantity [10].”
MethodThe Quantum Physics of Atomic Frequency Standards: Recent Developments
Vanier, J., & Tomescu, C. (2015) · CRC Press eBooks · doi:10.1201/b18738 · Cited by 553
Guidelines for Evaluating and Expressing the Uncertainty of NIST Measurement Results, | NIST
Taylor, B. N., & Kuyatt, C. E. (1993) · Cited by 514
Accuracy evaluation of NIST-F1
Jefferts, S. R., Shirley, J., Parker, T. E., Heavner, T. P., Meekhof, D. M., Nelson, C., Levi, F., Costanzo, G., Marchi, A. D., Drullinger, R., et al. (2002) · Metrologia · doi:10.1088/0026-1394/39/4/1 · Cited by 402
Self-citationParker, T. E., Jefferts, S. R., Heavner, T. P., & Donley, E. A. (2005) · Metrologia · doi:10.1088/0026-1394/42/5/013 · Cited by 220
Self-citationThe Quantum Physics of Atomic Frequency Standards
Vanier, J., & Audoin, C. (1989) · Taylor & Francis eBooks · doi:10.1201/9781420050851 · Cited by 180 · cited 4×
“Majorana transitions cause frequency shifts in magnetically state-selected beam frequency standards due to the different trajectories of the various mF levels in Cs [15].”
BackgroundMethodInfluentialArditi, M., & Carver, T. R. (1961) · Physical Review · doi:10.1103/physrev.124.800 · Cited by 174
Measurement and Cancellation of the Cold Collision Frequency Shift in an87RbFountain Clock
Fertig, C., & Gibble, K. (2000) · Physical Review Letters · doi:10.1103/physrevlett.85.1622 · Cited by 135
Measurement of the Stark shift of the Cs hyperfine splitting in an atomic fountain
Simon, E., Laurent, P., & Clairon, A. (1998) · Physical Review A · doi:10.1103/physreva.57.436 · Cited by 131
Controlling the Cold Collision Shift in High Precision Atomic Interferometry
Pereira Dos Santos, F., Marion, H., Bize, S., Sortais, Y., Clairon, A., & Salomon, C. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.233004 · Cited by 110
Research works printed but not linked: 7
- Howe D A Peppler T K, 2003, Proc. 2003 Joint Meeting IEEE Int. Freq. Control Symp. and EFTF Conf., 233
- Nava J H Walls F L Shirley J H Lee W D Armburo M M, 1996, Proc. 1996 IEEE Int. Freq. Control Symp., 973
- Parker T E, 2001, Proc. 2001 IEEE Int. Freq. Control Symp., 57
- 10.1103/physrevlett86.3743 · doi:10.1103/physrevlett86.3743
- Jefferts S R, 2005, IEEE Trans. Ultrason. Ferr.
- Jefferts S R Shirley J H Ashby N Heavner T P Donley E A Levi F Burt E A Dick G J, 2005, Proc. 19th Eur. Time and Frequency Forum
- Lee W D Shirley J H Walls F L Drullinger R E, 1995, Proc. 1995 IEEE Int. Freq. Control Symp., 113
Cited by
Nobel Lecture: Defining and measuring optical frequencies
Hall, J. L. (2006) · Reviews of Modern Physics · doi:10.1103/revmodphys.78.1279 · Cited by 614
Sr Lattice Clock at 1 × 10 –16 Fractional Uncertainty by Remote Optical Evaluation with a Ca Clock
Ludlow, A. D., Zelevinsky, T., Campbell, G. K., Blatt, S., Boyd, M. M., de Miranda, M. H. G., Martin, M. J., Thomsen, J. W., Foreman, S. M., Ye, J., et al. (2008) · Science · doi:10.1126/science.1153341 · Cited by 554
Quantum State Engineering and Precision Metrology Using State-Insensitive Light Traps
Ye, J., Kimble, H. J., & Katori, H. (2008) · Science · doi:10.1126/science.1148259 · Cited by 419
Prospects for a Millihertz-Linewidth Laser
Meiser, D., Ye, J., Carlson, D. R., & Holland, M. J. (2009) · Physical Review Letters · doi:10.1103/physrevlett.102.163601 · Cited by 378
Single-Atom Optical Clock with High Accuracy
Oskay, W. H., Diddams, S. A., Donley, E. A., Fortier, T. M., Heavner, T. P., Hollberg, L., Itano, W. M., Jefferts, S. R., Delaney, M. J., Kim, K., et al. (2006) · Physical Review Letters · doi:10.1103/physrevlett.97.020801 · Cited by 297
Self-citationOptical lattice clocks and quantum metrology
Katori, H. (2011) · Nature Photonics · doi:10.1038/nphoton.2011.45 · Cited by 281
“The international atomic time (TAI) is currently kept by an ensemble of Cs clocks with a fractional uncertainty of Δ ν/ν 0 a 10 −15 , and some Cs fountain clock”
BackgroundLemke, N., Ludlow, A., Barber, Z., Fortier, T., Diddams, S., Jiang, Y., Jefferts, S., Heavner, T., Parker, T., & Oates, C. (2009) · Physical Review Letters · doi:10.1103/physrevlett.103.063001 · Cited by 274
Self-citationFortier, T. M., Ashby, N., Bergquist, J. C., Delaney, M. J., Diddams, S. A., Heavner, T. P., Hollberg, L., Itano, W. M., Jefferts, S. R., Kim, K., et al. (2007) · Physical Review Letters · doi:10.1103/physrevlett.98.070801 · Cited by 226
Self-citationParker, T. E., Jefferts, S. R., Heavner, T. P., & Donley, E. A. (2005) · Metrologia · doi:10.1088/0026-1394/42/5/013 · Cited by 220
Self-citationFirst accuracy evaluation of NIST-F2
Heavner, T. P., Donley, E. A., Levi, F., Costanzo, G., Parker, T. E., Shirley, J. H., Ashby, N., Barlow, S., & Jefferts, S. R. (2014) · Metrologia · doi:10.1088/0026-1394/51/3/174 · Cited by 205
Self-citationSr87Lattice Clock with Inaccuracy below10−15
Boyd, M. M., Ludlow, A. D., Blatt, S., Foreman, S. M., Ido, T., Zelevinsky, T., & Ye, J. (2007) · Physical Review Letters · doi:10.1103/physrevlett.98.083002 · Cited by 187
Nuclear spin effects in optical lattice clocks
Boyd, M. M., Zelevinsky, T., Ludlow, A. D., Blatt, S., Zanon-Willette, T., Foreman, S. M., & Ye, J. (2007) · Physical Review A · doi:10.1103/physreva.76.022510 · Cited by 186
A strontium lattice clock with 3 × 10−17inaccuracy and its frequency
Falke, S., Lemke, N., Grebing, C., Lipphardt, B., Weyers, S., Gerginov, V., Huntemann, N., Hagemann, C., Al-Masoudi, A., Häfner, S., et al. (2014) · New Journal of Physics · doi:10.1088/1367-2630/16/7/073023 · Cited by 182
“The accuracy of today’s best Cs fountain clocks of 2− 4× 10 [32, 33, 34, 35, 36] sets a limit for the achievable accuracy of frequency measurements.”
BackgroundMillo, J., Abgrall, M., Lours, M., English, E. M. L., Jiang, H., Guéna, J., Clairon, A., Tobar, M. E., Bize, S., Le Coq, Y., et al. (2009) · Applied Physics Letters · doi:10.1063/1.3112574 · Cited by 179
The absolute frequency of the87Sr optical clock transition
Campbell, G. K., Ludlow, A. D., Blatt, S., Thomsen, J. W., Martin, M. J., de Miranda, M. H. G., Zelevinsky, T., Boyd, M. M., Ye, J., Diddams, S. A., et al. (2008) · Metrologia · doi:10.1088/0026-1394/45/5/008 · Cited by 151
Self-citationConditional Spin Squeezing of a Large Ensemble via the Vacuum Rabi Splitting
Chen, Z., Bohnet, J. G., Sankar, S. R., Dai, J., & Thompson, J. K. (2011) · Physical Review Letters · doi:10.1103/physrevlett.106.133601 · Cited by 167
Rabi spectroscopy and excitation inhomogeneity in a one-dimensional optical lattice clock
Blatt, S., Thomsen, J. W., Campbell, G. K., Ludlow, A. D., Swallows, M. D., Martin, M. J., Boyd, M. M., & Ye, J. (2009) · Physical Review A · doi:10.1103/physreva.80.052703 · Cited by 167
Optical Atomic Coherence at the 1-Second Time Scale
Boyd, M. M., Zelevinsky, T., Ludlow, A. D., Foreman, S. M., Blatt, S., Ido, T., & Ye, J. (2006) · Science · doi:10.1126/science.1133732 · Cited by 160
Uncertainty evaluation of the caesium fountain clock PTB-CSF2
Gerginov, V, Nemitz, N., Weyers, S., Schröder, R., Griebsch, D., & Wynands, R. (2010) · Metrologia · doi:10.1088/0026-1394/47/1/008 · Cited by 129
Accuracy evaluation of ITCsF2: a nitrogen cooled caesium fountain
Levi, F., Calonico, D., Calosso, C. E., Godone, A., Micalizio, S., & Costanzo, G. A. (2014) · Metrologia · doi:10.1088/0026-1394/51/3/270 · Cited by 134
Evaluation of systematic shifts of the88Sr+single-ion optical frequency standard at the10−17level
Dubé, P., Madej, A. A., Zhou, Z., & Bernard, J. E. (2013) · Physical Review A · doi:10.1103/physreva.87.023806 · Cited by 127
Frequency Measurements of Superradiance from the Strontium Clock Transition
Norcia, M. A., Cline, J. R. K., Muniz, J. A., Robinson, J. M., Hutson, R. B., Goban, A., Marti, G. E., Ye, J., & Thompson, J. K. (2018) · Physical Review X · doi:10.1103/physrevx.8.021036 · Cited by 140
“Optical atomic clocks are currently the most precise and accurate absolute frequency references, [1–9] while their microwave-domain counterparts are used to define the second [10, 11] and for other practical applications including communication and navigation [12, 13].”
BackgroundFirst accuracy evaluation of the NPL-CsF2 primary frequency standard
Szymaniec, K., Park, S. E., Marra, G., & Chałupczak, W. (2010) · Metrologia · doi:10.1088/0026-1394/47/4/003 · Cited by 109
Direct frequency comb spectroscopy
Stowe, M. C., Thorpe, M. J., Pe’er, A., Ye, J., Stalnaker, J. E., Gerginov, V. P., & Diddams, S. A. (2008) · Advances in atomic, molecular, and optical physics · doi:10.1016/s1049-250x(07)55001-9 · Cited by 107
Frequency evaluation of the doubly forbidden S01→P03 transition in bosonic Yb174
Poli, N., Barber, Z. W., Lemke, N., Oates, C. W., S., L., Stalnaker, J. E., Fortier, T. M., Diddams, S. A., Hollberg, L. W., Bergquist, J., et al. (2008) · Physical Review A · doi:10.1103/physreva.77.050501 · Cited by 100
Self-citationNIST Primary Frequency Standards and the Realization of the SI Second
Lombardi, M. A., Heavner, T. P., & Jefferts, S. R. (2007) · NCSLI Measure · doi:10.1080/19315775.2007.11721402 · Cited by 99
“Several evaluations of the accuracy of NIST-F1 have been published [59, 61, 62], and its present accuracy is ≈ 4 × 10-16.”
MethodSelf-citationLong-term comparison of caesium fountain primary frequency standards
Parker, T. E. (2010) · Metrologia · doi:10.1088/0026-1394/47/1/001 · Cited by 76
Self-citationProspects for precision measurements on ammonia molecules in a fountain
Bethlem, H. L., Kajita, M., Sartakov, B. G., Meijer, G., & Ubachs, W. (2008) · The European Physical Journal Special Topics · doi:10.1140/epjst/e2008-00809-5 · Cited by 89
Three-dimensional optical lattice clock with bosonicSr88atoms
Akatsuka, T., Takamoto, M., & Katori, H. (2010) · Physical Review A · doi:10.1103/physreva.81.023402 · Cited by 79
High-stability compact atomic clock based on isotropic laser cooling
Esnault, F.-X., Holleville, D., Rossetto, N., Guérandel, S., & Dimarcq, N. (2010) · Physical Review A · doi:10.1103/physreva.82.033436 · Cited by 85
The Epistemology of Measurement: A Model-based Account
Tal, E. (2013) · TSpace (University of Toronto) · Cited by 82
Boyd, M. M. (2007) · Cited by 78
Evaluation of caesium atomic fountain NICT-CsF1
Kumagai, M., Ito, H., Kajita, M., & Hosokawa, M. (2008) · Metrologia · doi:10.1088/0026-1394/45/2/003 · Cited by 76
Cancellation of the Collisional Frequency Shift in Caesium Fountain Clocks
Szymaniec, K., Chałupczak, W., Tiesinga, E., Williams, C. J., Weyers, S., & Wynands, R. (2007) · Physical Review Letters · doi:10.1103/physrevlett.98.153002 · Cited by 76
Evaluating and minimizing distributed cavity phase errors in atomic clocks
Li, R., & Gibble, K. (2010) · Metrologia · doi:10.1088/0026-1394/47/5/004 · Cited by 76
“t this power dependent template is used by a number of groups to evDCP uncertainty [3,12], aluate their clock’s including the NIST and INRIM clocks which report DCP uncertainties smaller than 3×10−17 [15,16], an order of magnitude smaller than those for other clocks. Another recent treatment used an incomplete mode ex…”
MethodInfluentialCs-based optical frequency measurement using cross-linked optical and microwave oscillators
Tamm, C., Huntemann, N., Lipphardt, B., Gerginov, V., Nemitz, N., Kazda, M., Weyers, S., & Peik, E. (2014) · Physical Review A · doi:10.1103/physreva.89.023820 · Cited by 72
Cold-collision-shift cancellation and inelastic scattering in a Yb optical lattice clock
Ludlow, A. D., Lemke, N. D., Sherman, J. A., Oates, C. W., Quéméner, G., von Stecher, J., & Rey, A. M. (2011) · Physical Review A · doi:10.1103/physreva.84.052724 · Cited by 51
Micro-fabricated components for cold atom sensors
McGilligan, J. P., Gallacher, K. F., Griffin, P. F., Paul, D. J., Arnold, A. S., & Riis, E. (2022) · Review of Scientific Instruments · doi:10.1063/5.0101628 · Cited by 65
Magic Frequencies for Cesium Primary-Frequency Standard
Flambaum, V. V., Dzuba, V. A., & Derevianko, A. (2008) · Physical Review Letters · doi:10.1103/physrevlett.101.220801 · Cited by 64
Accurate rubidium atomic fountain frequency standard
Ovchinnikov, Y. B., & Marra, G. (2011) · Metrologia · doi:10.1088/0026-1394/48/3/003 · Cited by 63
ULPAC: A Miniaturized Ultralow-Power Atomic Clock
Zhang, H., Okada, K., Herdian, H., Narayanan, A. T., Shirane, A., Suzuki, M., Harasaka, K., Adachi, K., Goka, S., & Yanagimachi, S. (2019) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2019.2941004 · Cited by 61
“For example, an atomic fountain clock used as a primary frequency standard consumes 1000 W and occupies a volume of approximately 3 m3 [11]–[13].”
MethodOrbit determination for next generation space clocks
Duchayne, L., Mercier, F., & Wolf, P. (2009) · Astronomy & Astrophysics · doi:10.1051/0004-6361/200809613 · Cited by 50
Optical-to-microwave frequency comparison with fractional uncertainty of 10-15
Stalnaker, J. E., Diddams, S. A., Fortier, T. M., Kim, K., Hollberg, L. W., Bergquist, J., Itano, W. M., Delany, M. J., Lorini, L., Oskay, W. H., et al. (2007) · Applied Physics B · doi:10.1007/s00340-007-2762-z · Cited by 59
Self-citationZanon-Willette, T., Ludlow, A. D., Blatt, S., Boyd, M. M., Arimondo, E., & Ye, J. (2006) · Physical Review Letters · doi:10.1103/physrevlett.97.233001 · Cited by 49
IEN-CsF1 primary frequency standard at INRIM: accuracy evaluation and TAI calibrations
Levi, F., Calonico, D., Lorini, L., & Godone, A. (2006) · Metrologia · doi:10.1088/0026-1394/43/6/010 · Cited by 48
Santarelli, G., Governatori, G., Chambon, D., Lours, M., Rosenbusch, P., Guéna, J., Chapelet, F., Bize, S., Tobar, M. E., Laurent, P., et al. (2009) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2009.1188 · Cited by 49
Differential Light-Shift Cancellation in a Magnetic-Field-Insensitive Transition of Rb87
Chicireanu, R., Nelson, K. D., Olmschenk, S., Lundblad, N. E., Derevianko, A., & Porto, J. V. (2011) · Physical Review Letters · doi:10.1103/physrevlett.106.063002 · Cited by 47
Defining and Measuring Optical Frequencies: The Optical Clock Opportunity— And More (Nobel Lecture)
Hall, J. L. (2006) · ChemPhysChem · doi:10.1002/cphc.200600457 · Cited by 46
Systematic evaluation of a 171Yb optical clock by synchronous comparison between two lattice systems
Gao, Q., Zhou, M., Han, C., Li, S., Zhang, S., Yao, Y., Li, B., Qiao, H., Ai, D., Lou, G., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-26365-w · Cited by 47
Kajita, M., Abe, M., Hada, M., & Moriwaki, Y. (2011) · Journal of Physics B Atomic Molecular and Optical Physics · doi:10.1088/0953-4075/44/2/025402 · Cited by 43
Proposed detection of variation inmp/meusing a vibrational transition frequency of a CaH+ion
Kajita, M., & Moriwaki, Y. (2009) · Journal of Physics B Atomic Molecular and Optical Physics · doi:10.1088/0953-4075/42/15/154022 · Cited by 41
Precise Frequency Comparison System Using Bidirectional Optical Amplifiers
Amemiya, M., Imae, M., Fujii, Y., Suzuyama, T., Hong, F.-L., & Takamoto, M. (2009) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2009.2025073 · Cited by 41
“Cesium atomic fountain clocks have frequency stability on the order of 10−13τ−1/2 or better [2]–[4], where τ is the averaging time in seconds.”
BackgroundJefferts, S. R., Heavner, T. P., Parker, T. E., Shirley, J. H., Donley, E. A., Ashby, N., Levi, F., Calonico, D., & Costanzo, G. A. (2014) · Physical Review Letters · doi:10.1103/physrevlett.112.050801 · Cited by 36
Self-citationDesign and metrological features of microwave synthesizers for atomic fountain frequency standard
Chambon, D., Lours, M., Chapelet, F., Bize, S., Tobar, M. E., Clairon, A., & Santarelli, G. (2007) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2007.306 · Cited by 41
“About six fountains currently participate in the definition of the SI second at a level of 10−15 or better [2]–[7], and at least 15 more standards are under development1.”
BackgroundEvaluation of the systematic shifts of a single- 40 Ca + -ion frequency standard
Huang, Y., Liu, Q., Cao, J. Z., Ou, B.-Q., Liu, P., Guan, H., Huang, X.-R., & Gao, K. (2011) · Physical Review A · doi:10.1103/physreva.84.053841 · Cited by 36
Ultracold atoms and precise time standards
Campbell, G. K., & Phillips, W. D. (2011) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2011.0229 · Cited by 36
Incorporating an Optical Clock Into a Time Scale
Yao, J., Parker, T. E., Ashby, N., & Levine, J. (2017) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2017.2773530 · Cited by 34
“4 × 10−15 at one day, which is typical Cs-fountain performance at low atom density [4]–[6].”
BackgroundSelf-citationRecent atomic clock comparisons at NIST
Lorini, L., Ashby, N., Brusch, A., Diddams, S. A., Drullinger, R. E., Eason, E., Fortier, T. M., Hastings, P., Heavner, T. P., Hume, D. B., et al. (2008) · The European Physical Journal Special Topics · doi:10.1140/epjst/e2008-00807-7 · Cited by 34
Self-citationThe MTsR-F2 fountain-type cesium frequency standard
Domnin, Y. S., Baryshev, V. N., Boyko, A. I., Elkin, G. A., Novoselov, A. V., Kopylov, L. N., & Kupalov, D. S. (2012) · Measurement Techniques · doi:10.1007/s11018-012-0102-0 · Cited by 34
Parker, T. E. (2012) · Review of Scientific Instruments · doi:10.1063/1.3682002 · Cited by 28
Self-citationKajita, M. (2008) · Physical Review A · doi:10.1103/physreva.77.012511 · Cited by 33
The Routledge Handbook of Philosophy of Scientific Modeling
Knuuttila, T., Carrillo, N., & Koskinen, R. (2024) · Routledge eBooks · doi:10.4324/9781003205647 · Cited by 32
Micromagic Clock: Microwave Clock Based on Atoms in an Engineered Optical Lattice
Beloy, K., Derevianko, A., Dzuba, V. A., & Flambaum, V. V. (2009) · Physical Review Letters · doi:10.1103/physrevlett.102.120801 · Cited by 29
Systematic Uncertainty Evaluation of the Cesium Fountain Primary Frequency Standard at NPL India
Acharya, A., Vattikonda, B., Arora, P., Yadav, S., Agarwal, A., & Gupta, A. S. (2016) · MAPAN · doi:10.1007/s12647-016-0190-4 · Cited by 28
Beloy, K. (2009) · PhDT · Cited by 28
Determination of the geopotential and orthometric height based on frequency shift equation
Shen, W., Ning, J., Liu, J., Li, J., & Chao, D. (2011) · Natural Science · doi:10.4236/ns.2011.35052 · Cited by 26
“Atomic clocks with the stability level of 10 have been created [19-21].”
BackgroundDevelopment and Preliminary Operation of 87Rb Continuously Running Atomic Fountain Clock at NTSC
Zhang, H., Ruan, J., Liu, D., Yang, F., Fan, S., Bai, Y., Guan, Y., Wang, X., Shi, J., & Zhang, S. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3218543 · Cited by 27
“Cesium fountain clocks are used as the primary frequency standard, and their uncertainties (B type) have reached 1–3 × 10−16 [3], [4], [5], [6], [7], [8], [9], [10], [11], [12].”
Target specification bias, counterfactual prediction, and algorithmic fairness in healthcare
Tal, E. (2023) · Proceedings of the AAAI/ACM Conference on AI Ethics and Society · doi:10.1145/3600211.3604678 · Cited by 26
Sensitive measurement ofmp/mevariance using vibrational transition frequencies of cold molecules
Kajita, M. (2009) · New Journal of Physics · doi:10.1088/1367-2630/11/5/055010 · Cited by 26
NIST cesium fountains: current status and future prospects
Jefferts, S. R., Heavner, T. P., Parker, T. E., & Shirley, J. H. (2007) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.734965 · Cited by 26
“More complete discussions can be found in [2,3].”
BackgroundSelf-citationSzymaniec, K., & Park, S. E. (2010) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2010.2088430 · Cited by 26
“In some cases, this has been achieved at the expense of the short-term stability being degraded by using low number of atoms in large cloud (molasses loading) [4], [5].”
BackgroundCryogenic fountain development at NIST and INRIM: preliminary characterization
Levi, F., Calosso, C. E., Calonico, D., Lorini, L., Bertacco, E. K., Godone, A., Costanzo, G. A., Mongino, B., Jefferts, S. R., Heavner, T. P., et al. (2010) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2010.1453 · Cited by 26
“however, nIsT-F1 [20] has demonstrated that it is also possible in standard molasses operation to achieve a relative uncertainty in the shift measurement well below 1 × 10−16.”
BackgroundSelf-citationRecent improvements in NIST-F1 and a resulting accuracy of /spl delta/f/f=0.61/spl times/10/sup -15/
Heavner, T. P., Jefferts, S. R., Donley, E. A., Shirley, J. H., & Parker, T. E. (2005) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2005.843812 · Cited by 22
Self-citationGravitational redshift at INRIM
Calonico, D., Cina, A., Bendea, I. H., Levi, F., Lorini, L., & Godone, A. (2007) · Metrologia · doi:10.1088/0026-1394/44/5/n03 · Cited by 22
ThêoH: a hybrid, high-confidence statistic that improves on the Allan deviation
Howe, D. A. (2006) · Metrologia · doi:10.1088/0026-1394/43/4/s20 · Cited by 22
Wu, B., Wang, Z. Y., Cheng, B., Wang, Q. Y., Xu, A., & Lin, Q. (2013) · Journal of Physics B Atomic Molecular and Optical Physics · doi:10.1088/0953-4075/47/1/015001 · Cited by 20
Preliminary Evaluation of the Cesium Fountain Primary Frequency Standard NMIJ-F2
Takamizawa, A., Yanagimachi, S., Tanabe, T., Hagimoto, K., Hirano, I., Watabe, K.-I., Ikegami, T., & Hartnett, J. G. (2015) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2015.2415015 · Cited by 20
Two Myths of Representational Measurement
Tal, E. (2021) · Perspectives on Science · doi:10.1162/posc_a_00391 · Cited by 19
Hall, J. L. (2006) · Uspekhi Fizicheskih Nauk · doi:10.3367/ufnr.0176.200612i.1353 · Cited by 18
Limits to time variation of fundamental constants from comparisons of atomic frequency standards
Lea, S. N. (2008) · The European Physical Journal Special Topics · doi:10.1140/epjst/e2008-00808-6 · Cited by 17
Laser cooling and trapping of ytterbium atoms
Xu, X., Wang, W., Zhou, Q., Li, G., Jiang, H., Chen, L., Ye, J., Zhou, Z. Z. Z., Cai, Y., Tang, H.-Y., et al. (2009) · 物理学前沿:英文版 · doi:10.1007/s11467-009-0033-7 · Cited by 17
A new microwave synthesis chain for the primary frequency standard NIST-F1
Heavner, T. P., Jefferts, S. R., Donley, E. A., Parker, T. E., & Levi, F. (2006) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/freq.2005.1573950 · Cited by 17
“INTRODUCTION NIST-F1 is a laser-cooled cesium (Cs) fountain primary frequency standard in operation at NIST, Boulder, CO [1, 2].”
BackgroundSelf-citationFeng, Y., Xue, H., Wang, X., Chen, S., & Zhou, Z. (2014) · Applied Physics B · doi:10.1007/s00340-014-5962-3 · Cited by 16
Highly Coherent Spectroscopy of Ultracold Atoms and Molecules in Optical Lattices
Zelevinsky, T., Blatt, S., Boyd, M. M., Campbell, G. K., Ludlow, A. D., & Ye, J. (2008) · ChemPhysChem · doi:10.1002/cphc.200700713 · Cited by 16
Wang, W., Ye, J., Jiang, H., Bi, Z., Ma, L.-S., & Xu, X. (2011) · Chinese Physics B · doi:10.1088/1674-1056/20/1/013201 · Cited by 16
International timescales with optical clocks (ITOC)
Margolis, H. S., Godun, R. M., Gill, P., Johnson, L. A. M., Shemar, S. L., Whibberley, P. B., Calonico, D., Levi, F., Lorini, L., Pizzocaro, M., et al. (2013) · 2013 Joint European Frequency and Time Forum & International Frequency Control Symposium (EFTF/IFC) · doi:10.1109/eftf-ifc.2013.6702183 · Cited by 15
Accuracy evaluation of primary frequency standard NIST-F4
Gerginov, V. P., Hoth, G. W., Heavner, T. P., Parker, T. E., Gibble, K., & Sherman, J. A. (2025) · Metrologia · doi:10.1088/1681-7575/adc7bd · Cited by 17
“During a measurement campaign, the fountain interleaves high-density and low-density modes to measure the collisional shift.”
InfluentialSelf-citationFuzesi, F., Jornod, A., Thomann, P., Plimmer, M. D., Dudle, G., Moser, R., Sache, L., & Bleuler, H. (2007) · Review of Scientific Instruments · doi:10.1063/1.2800777 · Cited by 15
Experimental Determination of the Mg24 I (3s3p)P23 Lifetime
Jensen, B. B., Ming, H., Westergaard, P. G., Gunnarsson, K., Madsen, M., Brusch, A., Hald, J., & Thomsen, J. W. (2011) · Physical Review Letters · doi:10.1103/physrevlett.107.113001 · Cited by 15
Legal and Technical Measurement Requirements for Time and Frequency
Lombardi, M. A. (2006) · NCSLI Measure · doi:10.1080/19315775.2006.11721335 · Cited by 15
“NIST and a handful of other national metrology laboratories can currently realize the second to uncertainties measured in parts in 1016 [1], and NIST has experimental standards already in place that promise uncertainties at least one or two orders of magnitude smaller.”
BackgroundOn a New Class of Self-Referencing, 1/τ Atomic Clocks
Wang, L. (2014) · Chinese Physics Letters · doi:10.1088/0256-307x/31/8/080601 · Cited by 14
Initial atomic coherences and Ramsey frequency pulling in fountain clocks
Gerginov, V. P., Nemitz, N., & Weyers, S. (2014) · Physical Review A · doi:10.1103/physreva.90.033829 · Cited by 15
Microwave Atomic Clock in the Optical Lattice with Specific Frequency
Zhou, X., Chen, X., Chen, J., Wang, Y., & Li, J. (2009) · Chinese Physics Letters · doi:10.1088/0256-307x/26/9/090601 · Cited by 13
Wang, Q., Zhang, N., Guang, W., Zhang, S., Wang, W., Wei, R., & Wang, Y. (2019) · Physical Review A · doi:10.1103/physreva.100.022510 · Cited by 14
Lu, X., Yin, M.-J., Li, T., Wang, Y., & Chang, H. (2020) · Applied Sciences · doi:10.3390/app10041440 · Cited by 13
“Relevant calculations show that under the same magnetic field, the quadratic Zeeman shift of an 87Sr optical lattice clock is 108 times smaller than that of a cesium clock [19], and is more than one order of magnitude smaller than Hg+ [20], Sr+ [21], and Yb+ [22] optical clocks.”
BackgroundProspects of operating a caesium fountain clock at zero collisional frequency shift
Szymaniec, K., Chałupczak, W., Weyers, S., & Wynands, R. (2007) · Applied Physics B · doi:10.1007/s00340-007-2813-5 · Cited by 13
Progress of the 87 Rb Fountain Clock
Zhou, Z., Wei, R., Shi, C., De-Sheng, L., Li, T., & Yu-Zhu, W. (2009) · Chinese Physics Letters · doi:10.1088/0256-307x/26/12/123201 · Cited by 13
Medium-term frequency stability of hydrogen masers as measured by a cesium fountain
Parker, T. E., Jefferts, S. R., & Heavner, T. P. (2010) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/freq.2010.5556319 · Cited by 13
“4 for some of the masers are far too large to be caused by NIST-F1 [3].”
BackgroundMethodSelf-citationNIST Cesium Fountains - Current Status and Future Prospects
Jefferts, S. R., Heavner, T. P., Parker, T. E., & Shirley, J. H. (2007) · Acta Physica Polonica A · doi:10.12693/aphyspola.112.759 · Cited by 13
Self-citationSwallows, M. D., Campbell, G. K., Ludlow, A. D., Boyd, M. M., Thomsen, J. W., Martin, M. J., Blatt, S., Nicholson, T., & Ye, J. (2010) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2010.1449 · Cited by 13
Metadata
- Authors
- Heavner, T. P., Jefferts, S. R., Donley, E. A., Shirley, J. H., & Parker, T. E.
- Affiliations
- National Institute of Standards and Technology (US)
- Venue
- Metrologia
- Publisher
- IOP Publishing
- Published
- 2005-09-13
- Volume
- 42
- Issue
- 5
- Pages
- 411-422
- ISSN
- 0026-1394 (ISSN-L)
- 1681-7575
- OpenAlex
- W2132308827
- Semantic Scholar
- 3ebf6349b81c4cee947aa33c268fe25c5a64958a
- Cited by
- 355
- References
- 22
- Citations by year
- 2026: 2 · 2025: 4 · 2024: 1 · 2023: 1 · 2022: 9 · 2021: 19 · 2020: 16 · 2019: 18 · 2018: 15 · 2017: 14 · 2016: 16 · 2015: 15 · 2014: 23 · 2013: 21 · 2012: 3
- FWCI
- 18.17
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Metrologia (publishedVersion)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Electrical Measurement Techniques
- Keywords
- primary frequency standard, fractional frequency uncertainty, uncertainty budget, time transfer, accuracy assessment
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.