NIST-F1: recent improvements and accuracy evaluations
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
In the last several years we have made many improvements to NIST-F1 (a laser-cooled Cs fountain primary frequency standard at the National Institute of Standards and Technology (NIST) in Boulder, Colorado) resulting in a reduction by over a factor of 2 in the uncertainty of the realization of the SI second. The two most recent accuracy evaluations of NIST-F1 had combined standard fractional uncertainties of 0.61 × 10 −15 (June 2004) and 0.53 × 10 −15 (January 2005), which were submitted to the Bureau International des Poids et Mesures with total fractional uncertainties (including time-transfer contributions) of, respectively, 0.88 × 10 −15 and 0.97 × 10 −15 . Here we discuss the improvements and evaluation methods and present an updated uncertainty budget.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Atomic clocks with the stability level of 10 -16 have been created [19][20][21].”
From Determination of the geopotential and orthometric height based on frequency shift equation (2011) · cites this paper as [19]
Citations
Cites
Guidelines for evaluating and expressing the uncertainty of NIST measurement results
Taylor, B. N., & Kuyatt, C. E. (2018) · doi:10.6028/nist.tn.1297-1993 · Cited by 2,582 · cited 1×
“However, Type A and Type B refer to the methods used to measure the physical quantity [10].”
MethodThe Quantum Physics of Atomic Frequency Standards: Recent Developments
Vanier, J., & Tomescu, C. (2015) · CRC Press eBooks · doi:10.1201/b18738 · Cited by 553
Guidelines for Evaluating and Expressing the Uncertainty of NIST Measurement Results, | NIST
Taylor, B. N., & Kuyatt, C. E. (1993) · Cited by 514
Accuracy evaluation of NIST-F1
Jefferts, S. R., Shirley, J., Parker, T. E., Heavner, T. P., Meekhof, D. M., Nelson, C., Levi, F., Costanzo, G., Marchi, A. D., Drullinger, R., et al. (2002) · Metrologia · doi:10.1088/0026-1394/39/4/1 · Cited by 402
Self-citationParker, T. E., Jefferts, S. R., Heavner, T. P., & Donley, E. A. (2005) · Metrologia · doi:10.1088/0026-1394/42/5/013 · Cited by 220
Self-citationThe Quantum Physics of Atomic Frequency Standards
Vanier, J., & Audoin, C. (1989) · Taylor & Francis eBooks · doi:10.1201/9781420050851 · Cited by 180 · cited 4×
“Majorana transitions cause frequency shifts in magnetically state-selected beam frequency standards due to the different trajectories of the various mF levels in Cs [15].”
BackgroundMethodInfluentialArditi, M., & Carver, T. R. (1961) · Physical Review · doi:10.1103/physrev.124.800 · Cited by 174
Measurement and Cancellation of the Cold Collision Frequency Shift in an87RbFountain Clock
Fertig, C., & Gibble, K. (2000) · Physical Review Letters · doi:10.1103/physrevlett.85.1622 · Cited by 135
Measurement of the Stark shift of the Cs hyperfine splitting in an atomic fountain
Simon, E., Laurent, P., & Clairon, A. (1998) · Physical Review A · doi:10.1103/physreva.57.436 · Cited by 131
Controlling the Cold Collision Shift in High Precision Atomic Interferometry
Pereira Dos Santos, F., Marion, H., Bize, S., Sortais, Y., Clairon, A., & Salomon, C. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.233004 · Cited by 110
Research works printed but not linked: 7
- Howe D A Peppler T K, 2003, Proc. 2003 Joint Meeting IEEE Int. Freq. Control Symp. and EFTF Conf., 233
- Nava J H Walls F L Shirley J H Lee W D Armburo M M, 1996, Proc. 1996 IEEE Int. Freq. Control Symp., 973
- Parker T E, 2001, Proc. 2001 IEEE Int. Freq. Control Symp., 57
- 10.1103/physrevlett86.3743 · doi:10.1103/physrevlett86.3743
- Jefferts S R, 2005, IEEE Trans. Ultrason. Ferr.
- Jefferts S R Shirley J H Ashby N Heavner T P Donley E A Levi F Burt E A Dick G J, 2005, Proc. 19th Eur. Time and Frequency Forum
- Lee W D Shirley J H Walls F L Drullinger R E, 1995, Proc. 1995 IEEE Int. Freq. Control Symp., 113
Cited by
Items 101–200 of 385
Cai, C., Shen, W., Shen, Z., & Xu, W. S. (2020) · IEEE Access · doi:10.1109/access.2020.3036988 · Cited by 12
Progress on optical-clock-based time scale at NIST: Simulations and preliminary real-data analysis
Yao, J., Sherman, J. A., Fortier, T. M., Leopardi, H., Parker, T. E., Levine, J., Savory, J., Romisch, S., McGrew, W. F., Zhang, X., et al. (2018) · NAVIGATION Journal of the Institute of Navigation · doi:10.1002/navi.248 · Cited by 12
Self-citationFrequency shifts in NIST Cs primary frequency standards due to transverse rf field gradients
Ashby, N., Barlow, S. E., Heavner, T. P., & Jefferts, S. R. (2015) · Physical Review A · doi:10.1103/physreva.91.033624 · Cited by 11
Self-citationDistributed cavity phase and the associated power dependence
Li, R., & Gibble, K. (2006) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/freq.2005.1573909 · Cited by 11
“Further, below we show an example of a DCP error with minimal power dependence for a particular distribution of wall losses in the cavity of [10].”
BackgroundMethodHackman, C., Levine, J., & Parker, T. E. (2006) · Cited by 11
Self-citationThe Nature of Time: from a Timeless Hamiltonian Framework to Clock Time of MetrologyPreprint
Prati, E. (2009) · arXiv (Cornell University) · doi:10.48550/arxiv.0907.1707 · Cited by 11
Optical Lattice Clock with Spin-1/2 Ytterbium Atoms
Lemke, N. (2012) · CU Scholar (University of Colorado Boulder) · Cited by 11
Quantum sensing using atomic clocks for nuclear and particle physics
Kawasaki, A. (2025) · Applied Physics Reviews · doi:10.1063/5.0273813 · Cited by 10
Atomic fountain frequency standard: principle and development
Wang, Q., Wei, R., & Wang, Y. (2018) · Acta Physica Sinica · doi:10.7498/aps.67.20180540 · Cited by 10
Distinguishing between evidence and its explanations in the steering of atomic clocks
Myers, J. M., & Madjid, F. H. (2014) · Annals of Physics · doi:10.1016/j.aop.2014.06.026 · Cited by 10
Comment on ‘Accurate rubidium atomic fountain frequency standard’
Li, R., & Gibble, K. (2011) · Metrologia · doi:10.1088/0026-1394/48/5/n03 · Cited by 10
Atomic clocks: A brief history and current status of research in India
Arora, P., AWASTHI, A., Vattikonda, B., Acharya, A., Yadav, S., Agarwal, A., & Gupta, A. S. (2014) · Pramana · doi:10.1007/s12043-014-0709-6 · Cited by 9
Ultracold strontium clock: Applications to the measurement of fundamental constant variations
Ludlow, A. D., Blatt, S., Zelevinsky, T., Campbell, G. K., Martin, M. J., Thomsen, J. W., Boyd, M. M., & Ye, J. (2008) · The European Physical Journal Special Topics · doi:10.1140/epjst/e2008-00806-8 · Cited by 9
Carrier thermometry of cold ytterbium atoms in an optical lattice clock
Han, C., Zhou, M., Zhang, X., Gao, Q., Xu, Y., Li, S., Zhang, S., & Xu, X. (2018) · Scientific Reports · doi:10.1038/s41598-018-26367-8 · Cited by 9
Ion Traps: A gentle introduction
Kajita, M. (2022) · Institute of Physics eBooks · doi:10.1088/978-0-7503-5472-1 · Cited by 9
Strontium Optical Lattice Clock at JILA
Boyd, M. E., Ludlow, A. D., Foreman, S. M., Zelevinsky, T., Blatt, S., Zanon-Willette, T., Campbell, G. K., de Miranda, M. H. G., Martin, M. J., & Ye, J. (2007) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/freq.2007.4319280 · Cited by 9
“The comb provides a measurement of the laser frequency relative to a microwave signal derived from a hydrogen maser calibrated to the NIST primary Cs fountain clock [12].”
MethodEntanglement-enhanced test proposal for local Lorentz-symmetry violation via spinor atoms
Zhuang, M., Huang, J., & Lee, C. (2022) · Quantum · doi:10.22331/q-2022-11-14-859 · Cited by 8
First-Order Sideband Pulling in Atomic Frequency Standards
Shirley, J. H., Heavner, T. P., & Jefferts, S. R. (2009) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2008.2008590 · Cited by 8
“To verify (11) and (16), experiments were performed with the NIST cesium fountain primary frequency standard NIST-F1 [1], [11].”
MethodSelf-citationReevaluation of the Optically Pumped Cesium Frequency Standard NRLM-4 With an H-Bend Ring Cavity
Hagimoto, K., Koga, Y., & Ikegami, T. (2008) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2008.922086 · Cited by 7
Design and operation of a transportable 87Rb atomic fountain clock
Cheng, H.-N., Zhang, Z., Deng, S., Ji, J.-W., Ren, W., Xiang, J., Zhao, J.-B., Zhao, X., Ye, M., Li, L., et al. (2021) · Review of Scientific Instruments · doi:10.1063/5.0047715 · Cited by 7
Infrared frequency standard based on magnetically trapped NH molecules
Kajita, M. (2006) · Physical Review A · doi:10.1103/physreva.74.035403 · Cited by 7
Towards Sub-10¿16 Transcontinental GPS Carrier-Phase Frequency Transfer: a Simulation Study
Hackman, C., & Levine, J. (2006) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/freq.2006.275487 · Cited by 7
Miniaturized optical system for atomic fountain clock
Lü, D., Qu, Q., Wang, B., Zhao, J.-B., Li, T., Liu, L., & Wang, Y. (2011) · Chinese Physics B · doi:10.1088/1674-1056/20/6/063201 · Cited by 6
Frequency Metrology with Optical Lattice Clocks
Hong, F.-L., & Katori, H. (2010) · Japanese Journal of Applied Physics · doi:10.1143/jjap.49.080001 · Cited by 6
Data analysis and phase ambiguity removal in the ACES microwave link
Duchayne, L., Wolf, P., Cacciapuoti, L., Hess, M.-P., Siccardi, M., & Schäfer, W. (2008) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/freq.2008.4623052 · Cited by 6
Wynands, R. (2009) · Lecture notes in physics · doi:10.1007/978-3-642-03174-8_13 · Cited by 6
Chen, Z. (2013) · CU Scholar (University of Colorado Boulder) · Cited by 6
Optimization of Operation Parameters in a Cesium Atomic Fountain Clock Using Monte Carlo Method
Li, H., Du, Y., Yang, X., Guo, Y., Liu, M., Li, W., Liu, H., & Lu, Z. H. (2021) · IEEE Access · doi:10.1109/access.2021.3113161 · Cited by 5
“As the most accurate reproduction of the SI ‘‘second’’ definition, atomic fountain clocks have been built in several metrology labs around the world [8]–[10].”
BackgroundKajita, M. (2009) · Canadian Journal of Physics · doi:10.1139/p08-097 · Cited by 5
Generalized clocks in timeless canonical formalism
Prati, E. (2011) · Journal of Physics Conference Series · doi:10.1088/1742-6596/306/1/012013 · Cited by 5
Zitterbewegung in External Magnetic Field: Classic versus Quantum Approach
Abyaneh, M. Z., & Farhoudi, M. (2011) · Foundations of Physics · doi:10.1007/s10701-011-9553-4 · Cited by 5
Time and Frequency Metrology: Part I: Realization and Dissemination of Indian Standard Time
Vattikonda, B., Das, M., Bhardwaj, T., Panja, S., Arora, P., Gupta, A., & Aswal, D. K. (2020) · Springer eBooks · doi:10.1007/978-981-15-8872-3_4 · Cited by 5
Characterization of the Th-229 nuclear clock transition
Seiferle, B. (2019) · Electronic Theses of LMU Munich (Ludwig-Maximilians-Universität München) · doi:10.5282/edoc.25340 · Cited by 5
Effective sideband cooling in an ytterbium optical lattice clock
Wang, J.-Q., Zhang, A., Tian, C.-C., Yin, N., Zhu, Q., Wang, B., Xiong, Z.-X., He, L., & Lv, B.-L. (2022) · Chinese Physics B · doi:10.1088/1674-1056/ac5392 · Cited by 4
Building a better atomic clock
Bloom, B. (2013) · Physics Today · doi:10.1063/pt.5.027159 · Cited by 4
“Ultimate results will far exceed these numbers, but this is after years or decades of research [4, 5, 6, 7, 8].”
BackgroundAn active optical frequency reference using a pulsed superradiant laser
Silva, J. M., Cline, J., Thompson, J. K., & Norcia, M. A. (2019) · Optical and Quantum Sensing and Precision Metrology II · doi:10.1117/12.2515582 · Cited by 4
Enabling the mass production of a chip-scale laser cooling platform
Bregazzi, A., Dyer, S., Griffin, P. F., Burt, D. P., Arnold, A. S., Riis, E., & McGilligan, J. P. (2021) · Quantum Technology: Driving Commercialisation of an Enabling Science · doi:10.1117/12.2601340 · Cited by 4
Kajita, M. (2008) · Physical Review A · doi:10.1103/physreva.78.024101 · Cited by 4
Metastable Magnesium fluorescence spectroscopy using a frequency-stabilized 517 nm laser
He, M., Jensen, B. B., Therkildsen, K. T., Brusch, A., & Thomsen, J. W. (2009) · Optics Express · doi:10.1364/oe.17.007682 · Cited by 4
Numerical study of relativistic frequency shift for the cold-atom clock experiment in space
Poncin-Lafitte, C. L., & Lambert, S. B. (2007) · Classical and Quantum Gravity · doi:10.1088/0264-9381/24/4/003 · Cited by 4
Levi, F., Calosso, C. E., Calonico, D., Lorini, L., Bertacco, E. K., Godone, A., Costanzo, G. A., Mongino, B., Jefferts, S. R., Heavner, T. P., et al. (2009) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/freq.2009.5168289 · Cited by 4
“The design of the cryogenic fountain is derived from the original design of NIST-F1 [11], which started operation in 1998, and exhibits a fractional frequency accuracy of 4×10-16.”
BackgroundSelf-citationMüller, S. (2010) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/t.76.2010.tde-11052010-154900 · Cited by 4
Measurement of the spin-forbidden decay rate (3s3d)1D2→(3s3p)P32,1 in M24g
Therkildsen, K. T., Jensen, B. B., Ryder, C. P., Malossi, N., & Thomsen, J. W. (2009) · Physical Review A · doi:10.1103/physreva.79.034501 · Cited by 4
High-Accuracy Microwave Atomic Clock via Magic Optical LatticePreprint
Zhou, X., Chen, X., & Chen, J. (2005) · arXiv (Cornell University) · doi:10.48550/arxiv.physics/0512244 · Cited by 4
Debs, J. E., Robins, N. P., & Close, J. D. (2013) · Science · doi:10.1126/science.1232923 · Cited by 4
Degenerate Gases of Strontium for Studies of Quantum Magnetism
Barker, D. S. (2016) · University Libraries (University of Maryland) · doi:10.13016/m2hb8s · Cited by 4
Optisches Speichern von Magnesium
Riedmann, M. (2010) · Institutional Repository of Leibniz Universität Hannover (Leibniz Universität Hannover) · doi:10.15488/7500 · Cited by 6
Optical state selection process with optical pumping in a cesium atomic fountain clock*
Han, L., Fang, F., Chen, W., Liu, K., Zuo, Y., Zheng, F., Dai, S., & Li, T. (2021) · Chinese Physics B · doi:10.1088/1674-1056/ac0698 · Cited by 3
Tal, E. (2024) · Routledge eBooks · doi:10.4324/9781003205647-23 · Cited by 3
“The extent of error associated with the frequency produced by a real atomic clock is calculated by theoretically predicting the extent to which it deviates from the ideal (Jefferts et al. 2002; Heavner et al. 2005).”
Shuanghao, 金. J., Pingwei, 林. L., Ning, 茹. R., Yanning, 马. M., Wensong, 江. J., & Zai, 罗. L. (2024) · Acta Optica Sinica · doi:10.3788/aos240678 · Cited by 3
Analysis of inhomogeneous-excitation frequency shifts of ytterbium optical lattice clocks
Chen, N., & Xu, X. (2014) · Laser Physics Letters · doi:10.1088/1612-2011/12/1/015501 · Cited by 3
Optical lattice clocks with non-interacting bosons and fermions
Katori, H., Takamoto, M., Akatsuka, T., & Hachisu, H. (2008) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/freq.2008.4622956 · Cited by 3
Measurement of the (3s3p)1P – (3s3d)1D isotope shift in Mg i
Steenstrup, M. P., Brusch, A., Jensen, B. B., Hald, J., & Thomsen, J. W. (2010) · Physical Review A · doi:10.1103/physreva.82.054501 · Cited by 3
Bayesian estimate of the zero-density frequency of a Cs fountain
Calonico, D., Levi, F., Lorini, L., & Mana, G. (2009) · Metrologia · doi:10.1088/0026-1394/46/6/004 · Cited by 3
From apples to atoms: measuring gravity with ultra cold atomic test masses
Debs, J. E., Hardman, K. S., Altin, P. A., McDonald, G., Close, J. D., & Robins, N. P. (2013) · Preview · doi:10.1071/pvv2013n164p30 · Cited by 3
“With its ceaseless ringing, a caesium atom is an oscillator that defines the International System of Units (SI) second at the level of 1 part in 1016 (Heavner et al. 2005).”
BackgroundAcharya, A., Arora, P., Yadav, S., & Gupta, A. S. (2020) · MAPAN · doi:10.1007/s12647-020-00405-1 · Cited by 3
An electronic sequence controller for the Cs fountain frequency standard developed at CSIR-NPL India
Yadav, S., Acharya, A., Arora, P., & Gupta, A. S. (2015) · Measurement · doi:10.1016/j.measurement.2015.07.041 · Cited by 3
Comparing room temperature and cryogenic cesium fountains
Heavner, T. P., Parker, T. E., Shirley, J. H., Donley, L. I., Jefferts, S. R., Levi, F., Calonico, D., Calosso, C. E., Costanzo, G. A., & Mongino, B. (2011) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/fcs.2011.5977845 · Cited by 3
“The microwave structure is essentially identical to that of NIST-F1 [1],[2],[3] with the exception that the microwave cavities are tuned to resonance at 80 K instead of 318 K (NIST-F1) or 340 K (IT CsF-1).”
BackgroundMethodSelf-citationProgress in rubidium fountain clock research at SIOM
Shi, C., Wei, R., Zhou, Z., Li, T., Li, L., & Wang, Y. (2011) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/fcs.2011.5977272 · Cited by 3
“The combined standard fractional uncertainties of the AFCs([4,5,6,7]) have reached to 10.”
BackgroundFortier, T. M., Ashby, N., Bergquist, J., Delaney, M. J., Diddams, S. A., Heavner, T. P., Hollberg, L. W., Itano, W. M., Jefferts, S. R., Kim, K., et al. (2007) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/freq.2007.4319157 · Cited by 3
Self-citationOptical Lattice Clocks for Precision Time and Frequency Metrology
Takamoto, M., & Katori, H. (2015) · Lecture notes in physics · doi:10.1007/978-4-431-55756-2_5 · Cited by 4
Present status of primary frequency standards at NPL, India
Acharya, A., Yadav, S., Arora, P., Agarwal, A., Vattikonda, B., & Gupta, A. S. (2016) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/fcs.2016.7546774 · Cited by 3
Standards of physical quantities
Kajita, M. (2018) · Institute of Physics eBooks · doi:10.1088/978-0-7503-2124-2ch1 · Cited by 2
Use of Bayesian statistics to reduce the density shift uncertainty in Cesium fountain
Calonico, D., Levi, F., Lorini, L., & Mana, G. (2010) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/freq.2010.5556320 · Cited by 2
“Today, fountains realize the second with a relative accuracy ranging from 3×10 to 10×10 [1-7] and, in the last ten years, allowed the uncertainty of the Atomic International Timescale (TAI) unit to be reduced from 1×10 to 5×10.”
BackgroundResidual frequency drift in an atomic fountain clock
Du, Y., Wei, R., Dong, R., Zou, F., Lin, J. L. J., Wang, W. W. W., & Wang, Y. W. Y. (2015) · Chinese Optics Letters · doi:10.3788/col201513.091201 · Cited by 2
Scalar Aharonov–Bohm Phase in Ramsey Atom Interferometry under Time-Varying Potential
Morinaga, A., Murakami, M., Nakamura, K., & Imai, H. (2016) · Atoms · doi:10.3390/atoms4030023 · Cited by 2
“However, in a Cs atomic fountain clock [6], the shift will be negligibly small because the AC Stark shift is too small to detect [17].”
BackgroundMethodHigh accuracy gravitational red-shift evaluation at INRIM
Calonico, D., Levi, F., Lorini, L., Godone, A., Cina, A., & Bendea, I. H. (2007) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/freq.2007.4319032 · Cited by 2
“INTRODUCTION The second in the International System (SI), is realized with an accuracy ranging from 4 to 10 parts in 10(16) by Caesium atomic fountain frequency standards [1-6].”
BackgroundA compact optical clock scheme based on caesium atomic beam
Zhang, S., Zhang, X., Jiang, Z., Pan, D., Peng, X., Chen, H., Chen, J., & Guo, H. M. (2016) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/fcs.2016.7546771 · Cited by 2
Requirements on orbitography for space clock missions
Duchayne, L., Mercier, F., & Wolf, P. (2007) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/freq.2007.4319283 · Cited by 2
Sources laser à 1,5 µm stabilisées en fréquence sur l'iode moléculaire
Philippe, C. (2017) · theses.fr (ABES) · doi:10.70675/c84a919fzdacez4f4czadd4z928817f76d35 · Cited by 2
A Study of Alkali-Resistant Materials for Use in Atomic Physics Based Systems
Fletcher, A. (2017) · CORE Scholar (Wright State University) · Cited by 1
Tasks of Information-Measuring Systems’ Functioning
Babak, V. P., Babak, S. V., Eremenko, V. S., Kuts, Y. V., & Zaporozhets, A. O. (2025) · Studies in systems, decision and control · doi:10.1007/978-3-031-89406-0_1 · Cited by 1
Speakable and unspeakable in physics of time
Prati, E. (2013) · EPJ Web of Conferences · doi:10.1051/epjconf/20135801019 · Cited by 1
Wang, W., Ye, J., Zhou, M., & Xu, X. (2009) · Conference on Lasers and Electro-Optics Pacific Rim (CLEO-PR) · doi:10.1109/cleopr.2009.5292118 · Cited by 1
“INTRODUCTION Recently the experimental results show that the fractional frequency uncertainty of the strontium optical atomic clock has been close to 1x10 [1-3], which has gone beyond that of the cesium fountain atomic clock [4].”
BackgroundInfrared frequency standard using electrically trapped molecules
Kajita, M. (2008) · Physical Review A · doi:10.1103/physreva.77.054502 · Cited by 1
A Laser-Cooled Frequency Standard for GPS
Heavner, T. P., Barlow, S. E., Weiss, M. A., Ashby, N., & Jefferts, S. R. (2011) · Cited by 1
Self-citationMeasurement of the Microwave Lensing shift in NIST-F1 and NIST-F2
Jefferts, S. R., Heavner, T. P., Barlow, S. E., & Ashby, N. (2016) · Journal of Physics Conference Series · doi:10.1088/1742-6596/723/1/012005 · Cited by 1
Self-citationSynchronization and Sensing with Steady State Superradiance and Spin Squeezing
Weiner, J. M. (2015) · CU Scholar (University of Colorado Boulder) · Cited by 1
A Novel Technique for Blackbody Shift Evaluation in Cs With a Fountain Standard
Berutto, M., Costanzo, G. A., & Marchi, A. D. (2007) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2007.891122 · Cited by 1
“4 · 10−2, the shift is two orders of magnitude larger than the accuracy target when the latter is in the low 10−16 [10], [11].”
BackgroundNIST time and frequency bulletin, no. 633
Petty, E. M. (2010) · doi:10.6028/nist.ir.6658-09 · Cited by 1
NIST time and frequency bulletin - May
Stephenson, K. R. (2018) · doi:10.6028/nist.ir.8205-05 · Cited by 1
NIST time and frequency bulletin : October 2020
Rodriguez, K. (2020) · doi:10.6028/nist.ir.8296-10 · Cited by 1
NIST time and frequency bulletin :
Rodriguez, K. (2021) · doi:10.6028/nist.ir.8346-02 · Cited by 1
Development of a Cesium Fountain Clock at HUST: Preliminary ResultsPreprint
Li, H., Du, Y., Liu, H., Guo, Y., Liu, M., Li, W., & Lu, Z. H. (2021) · arXiv (Cornell University) · doi:10.48550/arxiv.2110.09703 · Cited by 1
“I. INTRODUCTION ESIUM fountain clocks serve as primary frequency standards for International Atomic Time (TAI) [1-12], and have many applications in fundamental research fields such as precision measurement physics [13-14], relativity theory testing [15], as well as applications in navigation systems [16].”
BackgroundRamsey interferometry in three-level and five-level systems of $^{87}Rb$ Bose-Einstein condensatesPreprint
Thenuwara, A., & Sidorov, A. I. (2023) · arXiv (Cornell University) · doi:10.48550/arxiv.2308.11095 · Cited by 1
Lemke, N., Ludlow, A. D., Barber, Z. W., Poli, N., Hoyt, C., S., L., Stalnaker, J. E., Oates, C. W., Hollberg, L. W., Bergquist, J., et al. (2009) · Symposium on Frequency Standards and Metrology · doi:10.1142/9789812838223_0021
Self-citationPrecision Measurements with ultra-cold Alkaline Earth Atoms
Thomsen, J. W., Westergaard, P. G., Matin, R., Martin, M. J., & Ye, J. (2012) · Latin America Optics and Photonics Conference · doi:10.1364/laop.2012.ls4b.2
A choice of wave functions in the making of time
Myers, J. M., & Madjid, F. H. (2013) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2016031
Manipulation of the collisional frequency shift in caesium fountain clocks
Szymaniec, K., Chałupczak, W., Weyers, S., Wynands, R., Tiesinga, E., & Williams, C. J. (2007) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.732017
“number of detected atoms [9] or by operating the fountain at very low densities [7], it would be preferable if the shift could be avoided or cancelled in the first place.”
BackgroundOptical Lattice Clocks toward 10−17 Uncertainty
Katori, H. (2010) · Conference on Lasers and Electro-Optics · doi:10.1364/cleo.2010.cmd3
Absolute Optical Frequency Measurements with a Fractional Frequency Uncertainty at 1 ՠ10¿15
Stalnaker, J. E., Diddams, S. A., Kim, K., Hollberg, L. W., Donley, E. A., Heavner, T. P., Jefferts, S. R., Levi, F., Parker, T. E., Bergquist, J., et al. (2006) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/freq.2006.275430
“3 of the current uncertainty in the NIST-F1 frequency standard [9], [10].”
BackgroundSelf-citationParker, T. E. (2004)
Self-citationRecent Improvements in NIST-F1 and a Resulting Accuracy of
Heavner, T. P., Jefferts, S. R., Donley, E. A., Shirley, J. H., & Parker, T. E. (2005)
Self-citationBayesian inference of a negative quantity from positive measurement results
Calonico, D., Levi, F., Lorini, L., & Mana, G. (2009) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/freq.2009.5168246
Chen, J., Zhou, X., & Chen, X. (2006) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/freq.2006.275396
“The most recently reported performance of atomic fountain clocks showed that the fountain techniques have reached the maturity to a total fractional uncertainty of 4 × 10−16 [8]–[11].”
BackgroundSR OPTICAL CLOCK WITH HIGH STABILITY AND ACCURACY
Ludlow, A. D., Blatt, S., BOYD, M., Campbell, G. K., Foreman, S. M., MARTIN, M., de Miranda, M. H. G., Zelevinsky, T., YE, J., Fortier, T. M., et al. (2008) · Laser Spectroscopy · doi:10.1142/9789812813206_0026
“For absolute frequency measurements, a directoctave-spanning, self-referenced frequency comb similar to that reported in [11] is stabilized by the clock laser at 698 nm. The comb provides a measurement of the laser frequency relative to a microwave signal derived from a hydrogen maser calibrated to the NIST primary Cs…”
MethodLegal and Technical Requirements for Time and Frequency Metrology
Lombardi, M. A. (2006)
FREQUENCY STANDARD TIME AND FREQUENCY MEASUREMENTS
Domnin, S., Baryshev, V. N., Boyko, A. I., Elkin, G. A., Novoselov, A. V., Kopylov, L. N., & Kupalov, D. S. (2013)
NIST time and frequency bulletin, no. 579
Petty, E. M. (2006) · doi:10.6028/nist.ir.6639-03
Metadata
- Authors
- Heavner, T. P., Jefferts, S. R., Donley, E. A., Shirley, J. H., & Parker, T. E.
- Affiliations
- National Institute of Standards and Technology (US)
- Venue
- Metrologia
- Publisher
- IOP Publishing
- Published
- 2005-09-13
- Volume
- 42
- Issue
- 5
- Pages
- 411-422
- ISSN
- 0026-1394 (ISSN-L)
- 1681-7575
- OpenAlex
- W2132308827
- Semantic Scholar
- 3ebf6349b81c4cee947aa33c268fe25c5a64958a
- Cited by
- 355
- References
- 22
- Citations by year
- 2026: 2 · 2025: 4 · 2024: 1 · 2023: 1 · 2022: 9 · 2021: 19 · 2020: 16 · 2019: 18 · 2018: 15 · 2017: 14 · 2016: 16 · 2015: 15 · 2014: 23 · 2013: 21 · 2012: 3
- FWCI
- 18.17
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Metrologia (publishedVersion)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Electrical Measurement Techniques
- Keywords
- primary frequency standard, fractional frequency uncertainty, uncertainty budget, time transfer, accuracy assessment
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.