Operation of the NIST-F1 caesium fountain primary frequency standard with a maser ensemble, including the impact of frequency transfer noise
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
The operation of a caesium fountain primary frequency standard is greatly influenced by the characteristics of two other important facilities. The first is a stable frequency reference and the second is the frequency-transfer system. A stable frequency reference such as a hydrogen maser is a virtual necessity since essentially no fountain dead time can be tolerated without it. The frequency stability of this reference has a significant impact on the procedures for evaluating certain systematic biases in the fountain. State-of-the-art frequency transfer technology is also necessary if the fountain is intended to contribute to TAI or to be compared with other remotely located frequency standards without excessive degradation of stated uncertainties. We discuss the facilities available at the National Institute of Standards and Technology (NIST) and how they impact the operation of NIST-F1, the primary frequency standard at NIST.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Atomic clocks with the stability level of 10 -16 have been created [19][20][21].”
From Determination of the geopotential and orthometric height based on frequency shift equation (2011) · cites this paper as [21]
Citations
Cites
Data Reduction and Error Analysis for the Physical Sciences
Bevington, P. R., Robinson, D. K., Blair, J. M., Mallinckrodt, A. J., & McKay, S. (1993) · Computers in Physics · doi:10.1063/1.4823194 · Cited by 14,824
Accuracy evaluation of NIST-F1
Jefferts, S. R., Shirley, J., Parker, T. E., Heavner, T. P., Meekhof, D. M., Nelson, C., Levi, F., Costanzo, G., Marchi, A. D., Drullinger, R., et al. (2002) · Metrologia · doi:10.1088/0026-1394/39/4/1 · Cited by 402
Self-citationNIST-F1: recent improvements and accuracy evaluations
Heavner, T. P., Jefferts, S. R., Donley, E. A., Shirley, J. H., & Parker, T. E. (2005) · Metrologia · doi:10.1088/0026-1394/42/5/012 · Cited by 355
Self-citationUncertainty evaluation of the atomic caesium fountain CSF1 of the PTB
Weyers, S., H bner, U., Schr der, R., Tamm, C., & Bauch, A. (2001) · Metrologia · doi:10.1088/0026-1394/38/4/7 · Cited by 160
Controlling the Cold Collision Shift in High Precision Atomic Interferometry
Pereira Dos Santos, F., Marion, H., Bize, S., Sortais, Y., Clairon, A., & Salomon, C. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.233004 · Cited by 110 · cited 1×
“This minimizes the impact of any maser noise because the cycle time is in the range where the maser noise is predominantly white FM, and consequently it averages down approximately as the square root of the number of cycles [9].”
BackgroundAssessment of GPS carrier-phase stability for time-transfer applications
Larson, K. M., Levine, J., Nelson, L. M., & Parker, T. E. (2000) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.827441 · Cited by 77 · cited 2×
“Such observations indicate that transfer instabilities are generally flicker PM in nature out to as many as 100 days [3, 14, 15].”
BackgroundSelf-citationCollisional Frequency Shifts in133CsFountain Clocks
Leo, P. J., Julienne, P. S., Mies, F. H., & Williams, C. J. (2001) · Physical Review Letters · doi:10.1103/physrevlett.86.3743 · Cited by 64
First comparison of remote cesium fountains
Parker, T., Hetzel, P., Jefferts, S., Weyers, S., Nelson, L., Bauch, A., & Levine, J. (2002) · Proceedings of the 2001 IEEE International Frequncy Control Symposium and PDA Exhibition (Cat. No.01CH37218) · doi:10.1109/freq.2001.956161 · Cited by 37 · cited 2×
“Uncertainty in frequency transfer generally decreases in a manner inversely proportional to the length of the time interval of the comparison, which makes long comparisons desirable [3].”
BackgroundSelf-citationHydrogen maser ensemble performance and characterization of frequency standards
Parker, T. E. (2003) · Proceedings of the 1999 Joint Meeting of the European Frequency and Time Forum and the IEEE International Frequency Control Symposium (Cat. No.99CH36313) · doi:10.1109/freq.1999.840736 · Cited by 28
Self-citationEnvironmental factors and hydrogen maser frequency stability
Parker, T. E. (1999) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.764861 · Cited by 26
Self-citation
Research works printed but not linked: 5
- Parker T E Hetzel P Jefferts S R Weyers S Nelson L M Bauch A Levine J, 2001, Proc. 2001 IEEE Int. Frequency Control Symp., 63
- 10.1103/physrevlett86.3743 · doi:10.1103/physrevlett86.3743
- Howe D A Peppler T K, 2003, Proc. 2003 Joint Meeting of the IEEE Int. Frequency Control Symp. and the European Frequency and Time Forum, 233
- Douglas R J Boulanger J S, 1997, Proc. 11th European Frequency and Time Forum, 345
- Parker T E Zhang V S McKinley A Nelson L M Rohde J Matsakis D, 2002, Proc. 2002 Precise Time and Time Interval Meeting, 381
Cited by
NIST-F1: recent improvements and accuracy evaluations
Heavner, T. P., Jefferts, S. R., Donley, E. A., Shirley, J. H., & Parker, T. E. (2005) · Metrologia · doi:10.1088/0026-1394/42/5/012 · Cited by 355
Self-citationSingle-Atom Optical Clock with High Accuracy
Oskay, W. H., Diddams, S. A., Donley, E. A., Fortier, T. M., Heavner, T. P., Hollberg, L., Itano, W. M., Jefferts, S. R., Delaney, M. J., Kim, K., et al. (2006) · Physical Review Letters · doi:10.1103/physrevlett.97.020801 · Cited by 297
Self-citationObservation of theS01→P03Clock Transition inAl+27
Rosenband, T., Schmidt, P., Hume, D., Itano, W., Fortier, T., Stalnaker, J., Kim, K., Diddams, S., Koelemeij, J., Bergquist, J., et al. (2007) · Physical Review Letters · doi:10.1103/physrevlett.98.220801 · Cited by 231
Fortier, T. M., Ashby, N., Bergquist, J. C., Delaney, M. J., Diddams, S. A., Heavner, T. P., Hollberg, L., Itano, W. M., Jefferts, S. R., Kim, K., et al. (2007) · Physical Review Letters · doi:10.1103/physrevlett.98.070801 · Cited by 226
Self-citationFirst accuracy evaluation of NIST-F2
Heavner, T. P., Donley, E. A., Levi, F., Costanzo, G., Parker, T. E., Shirley, J. H., Ashby, N., Barlow, S., & Jefferts, S. R. (2014) · Metrologia · doi:10.1088/0026-1394/51/3/174 · Cited by 205
Self-citationCompact Optical Atomic Clock Based on a Two-Photon Transition in Rubidium
Martin, K. W., Phelps, G., Lemke, N. D., Bigelow, M. S., Stuhl, B., Wojcik, M., Holt, M., Coddington, I., Bishop, M. W., & Burke, J. H. (2018) · Physical Review Applied · doi:10.1103/physrevapplied.9.014019 · Cited by 169
“Laboratory-based primary frequency standards, which utilize microwave transitions between atomic hyperfine levels, provide the highest degree of timing accuracy and are used to form international timescales [2, 3]; in many cases, however, applications beyond timekeeping require clocks that are deployed outside the lab…”
BackgroundLong-term comparison of caesium fountain primary frequency standards
Parker, T. E. (2010) · Metrologia · doi:10.1088/0026-1394/47/1/001 · Cited by 76
Self-citationNIST Primary Frequency Standards and the Realization of the SI Second
Lombardi, M. A., Heavner, T. P., & Jefferts, S. R. (2007) · NCSLI Measure · doi:10.1080/19315775.2007.11721402 · Cited by 99
“[73] The time scale continuously generates and outputs both a 5 MHz sine wave frequency, and 1 pulse per second timing signal, which is a physical, realtime realization of the SI second.”
BackgroundSelf-citationOptical-to-microwave frequency comparison with fractional uncertainty of 10-15
Stalnaker, J. E., Diddams, S. A., Fortier, T. M., Kim, K., Hollberg, L. W., Bergquist, J., Itano, W. M., Delany, M. J., Lorini, L., Oskay, W. H., et al. (2007) · Applied Physics B · doi:10.1007/s00340-007-2762-z · Cited by 59
Self-citationIEN-CsF1 primary frequency standard at INRIM: accuracy evaluation and TAI calibrations
Levi, F., Calonico, D., Lorini, L., & Godone, A. (2006) · Metrologia · doi:10.1088/0026-1394/43/6/010 · Cited by 48
A null test of general relativity based on a long-term comparison of atomic transition frequencies
Ashby, N., Parker, T. E., & Patla, B. R. (2018) · Nature Physics · doi:10.1038/s41567-018-0156-2 · Cited by 53
“Environmental factors affecting H masers are studied in detail in Parker (1999)36 and the impact of frequency transfer noise in comparing masers and Cs fountains is described in Parker et al. (2005)29 (see also, ref.”
BackgroundSelf-citationJefferts, S. R., Heavner, T. P., Parker, T. E., Shirley, J. H., Donley, E. A., Ashby, N., Levi, F., Calonico, D., & Costanzo, G. A. (2014) · Physical Review Letters · doi:10.1103/physrevlett.112.050801 · Cited by 36
Self-citationAccurate, Traceable, and Verifiable Time Synchronization for World Financial Markets
Lombardi, M. A., Novick, A. N., Neville-Neil, G. V., & Cooke, B. (2016) · Journal of Research of the National Institute of Standards and Technology · doi:10.6028/jres.121.023 · Cited by 35
“The UTC(NIST) time scale consists of an ensemble of cesium beam and hydrogen maser clocks that is periodically calibrated by a cesium fountain primary frequency standard [31].”
MethodRecent atomic clock comparisons at NIST
Lorini, L., Ashby, N., Brusch, A., Diddams, S. A., Drullinger, R. E., Eason, E., Fortier, T. M., Hastings, P., Heavner, T. P., Hume, D. B., et al. (2008) · The European Physical Journal Special Topics · doi:10.1140/epjst/e2008-00807-7 · Cited by 34
Self-citationLeibrandt, D. R., Thorpe, M. J., Chou, C. W., Fortier, T. M., Diddams, S. A., & Rosenband, T. (2013) · Physical Review Letters · doi:10.1103/physrevlett.111.237402 · Cited by 28
Parker, T. E. (2012) · Review of Scientific Instruments · doi:10.1063/1.3682002 · Cited by 28
Self-citationDetermination of the geopotential and orthometric height based on frequency shift equation
Shen, W., Ning, J., Liu, J., Li, J., & Chao, D. (2011) · Natural Science · doi:10.4236/ns.2011.35052 · Cited by 26
Budget of Uncertainties in the Cesium Frequency Frame of Fountain Type
Blinov, I. Y., Бойко, А. И., Domnin, Y. S., Kostromin, V. P., Kupalova, O. V., & Kupalov, D. S. (2017) · Measurement Techniques · doi:10.1007/s11018-017-1145-z · Cited by 25
“33 shift; the error of this shift enters into the statistical error [5], therefore the error of its determination is excluded from the NSE.”
ThêoH: a hybrid, high-confidence statistic that improves on the Allan deviation
Howe, D. A. (2006) · Metrologia · doi:10.1088/0026-1394/43/4/s20 · Cited by 22
NIST cesium fountains: current status and future prospects
Jefferts, S. R., Heavner, T. P., Parker, T. E., & Shirley, J. H. (2007) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.734965 · Cited by 26
Self-citationBeloy, K. (2009) · PhDT · Cited by 28
A proposal on the test of general relativity by clock transportation experiments
Shen, W., Ning, J., Chao, D., & Liu, J. (2009) · Advances in Space Research · doi:10.1016/j.asr.2008.04.001 · Cited by 14
Detection of the clock transition (1.14 μm) in ultra-cold thulium atoms
Golovizin, A. A., Калганова, Е. С., Сукачев, Д. Д., Vishnyakova, G. A., Semerikov, I. A., Soshenko, V. V., Tregubov, D. O., Akimov, A. V., Kolachevsky, N., Khabarova, K. Y., et al. (2015) · Quantum Electronics · doi:10.1070/qe2015v045n05abeh015749 · Cited by 14
NIST Cesium Fountains - Current Status and Future Prospects
Jefferts, S. R., Heavner, T. P., Parker, T. E., & Shirley, J. H. (2007) · Acta Physica Polonica A · doi:10.12693/aphyspola.112.759 · Cited by 13
Self-citationLegal and Technical Measurement Requirements for Time and Frequency
Lombardi, M. A. (2006) · NCSLI Measure · doi:10.1080/19315775.2006.11721335 · Cited by 15
Distinguishing between evidence and its explanations in the steering of atomic clocks
Myers, J. M., & Madjid, F. H. (2014) · Annals of Physics · doi:10.1016/j.aop.2014.06.026 · Cited by 10
The Development of a Unified Time and Frequency Program in the SIM Region
López-Romero, J. M., & Lombardi, M. A. (2010) · NCSLI Measure · doi:10.1080/19315775.2010.11721524 · Cited by 5
Howe, D. A., McGee-Taylor, J., & Tasset, T. N. (2006) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/freq.2006.275488 · Cited by 5
“moved, we can thus achieve a time-domain statistical measure that has a six-times increase in edf’s, hence, subsantially improved confidence, on the reported level of frequency stability at the longest-term τ -value of Avar for a primary frequency standard properly exhibiting WHFM [ 16 ], [17], [18].”
BackgroundProgress in Brazilian Cesium atomic fountain-BrCsF
Rodriguez, S. A., Bagnato, V. S., Bueno, C., Pechoneri, R. D., Müller, S., & Magalhães, D. V. (2016) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/fcs.2016.7546818 · Cited by 3
“Cesium fountains have reached a special place in the field of time and frequency standards, becoming the best primary realization of the second (s) and having a key responsibility in maintaining the International Atomic Time (TAI) [1].”
BackgroundInfluentialComparing room temperature and cryogenic cesium fountains
Heavner, T. P., Parker, T. E., Shirley, J. H., Donley, L. I., Jefferts, S. R., Levi, F., Calonico, D., Calosso, C. E., Costanzo, G. A., & Mongino, B. (2011) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/fcs.2011.5977845 · Cited by 3
Self-citationA Fast Algorithm for Calculation of Thêo1
Lewis, B. (2020) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2020.2996313 · Cited by 2
“These properties have allowed Thêo1 to be used for long-running experiments where data sets cannot easily be extended [4].”
Performance and Applications of an Ensemble of Atomic Fountains
Peil, S., Hanssen, J. L., Swanson, T. B., Crane, S. G., & Ekstrom, C. R. (2012) · Cited by 1
Seznec, B., Minea, T. M., Dessante, P., Testé, P., & Maynard, G. (2022) · Springer eBooks · doi:10.1007/978-3-030-98419-9_1 · Cited by 1
NIST time and frequency bulletin - May
Stephenson, K. R. (2018) · doi:10.6028/nist.ir.8205-05 · Cited by 1
NIST time and frequency bulletin : October 2020
Rodriguez, K. (2020) · doi:10.6028/nist.ir.8296-10 · Cited by 1
NIST time and frequency bulletin :
Rodriguez, K. (2021) · doi:10.6028/nist.ir.8346-02 · Cited by 1
A choice of wave functions in the making of time
Myers, J. M., & Madjid, F. H. (2013) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2016031
Absolute Optical Frequency Measurements with a Fractional Frequency Uncertainty at 1 ՠ10¿15
Stalnaker, J. E., Diddams, S. A., Kim, K., Hollberg, L. W., Donley, E. A., Heavner, T. P., Jefferts, S. R., Levi, F., Parker, T. E., Bergquist, J., et al. (2006) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/freq.2006.275430
“The hydrogen maser used in the experiment is part of a collection of five masers that are periodically calibrated with respect to the Cs NIST-F1 standard [ 26 ].”
MethodSelf-citationQuantum Algorithms for Atomic Clocks
MULLAN, M. J. (2013) · CU Scholar (University of Colorado Boulder) · Cited by 1
Legal and Technical Requirements for Time and Frequency Metrology
Lombardi, M. A. (2006)
NIST time and frequency bulletin, no. 579
Petty, E. M. (2006) · doi:10.6028/nist.ir.6639-03
NIST time and frequency bulletin: January 2017
Stephenson, K. R. (2017) · doi:10.6028/nist.ir.8167-01
NIST time and frequency bulletin, no. 591
Petty, E. M. (2007) · doi:10.6028/nist.ir.6646-03
NIST time and frequency bulletin, no. 625
Petty, E. M. (2010) · doi:10.6028/nist.ir.6658-01
NIST time and frequency bulletin: december
Stephenson, K. R. (2017) · doi:10.6028/nist.ir.8167-12
NIST time and frequency bulletin: March 2017
Stephenson, K. R. (2017) · doi:10.6028/nist.ir.8167-03
NIST time and frequency bulletin - January
Stephenson, K. R. (2018) · doi:10.6028/nist.ir.8205-01
NIST time and frequency bulletin, no. 593
Petty, E. M. (2007) · doi:10.6028/nist.ir.6646-05
NIST time and frequency bulletin, no. 657
Petty, E. M. (2012) · doi:10.6028/nist.ir.6665-09
NIST time and frequency bulletin, no. 577
Petty, E. M. (2006) · doi:10.6028/nist.ir.6639-01
NIST time and frequency bulletin, no. 590
Petty, E. M. (2007) · doi:10.6028/nist.ir.6646-02
NIST time and frequency bulletin, no. 617
Petty, E. M. (2009) · doi:10.6028/nist.ir.6656-05
NIST time and frequency bulletin, no. 610
Petty, E. M. (2008) · doi:10.6028/nist.ir.6653-10
NIST time and frequency bulletin, no. 603
Petty, E. M. (2008) · doi:10.6028/nist.ir.6653-03
NIST time and frequency bulletin, no. 587
Petty, E. M. (2006) · doi:10.6028/nist.ir.6639-11
NIST Time and Frequency Bulletin: August 2016
Lichtfuss, K. H. (2016) · doi:10.6028/nist.ir.8104-08
NIST time and frequency bulletin, no. 627
Petty, E. M. (2010) · doi:10.6028/nist.ir.6658-03
NIST time and frequency bulletin-December 2016
Lichtfuss, K. H. (2016) · doi:10.6028/nist.ir.8104-12
NIST time and frequency bulletin, no. 648
Petty, E. M. (2011) · doi:10.6028/nist.ir.6661-12
NIST time and frequency bulletin, no. 652
Petty, E. M. (2012) · doi:10.6028/nist.ir.6665-04
NIST time and frequency bulletin, no. 582
Petty, E. M. (2006) · doi:10.6028/nist.ir.6639-06
NIST time and frequency bulletin, no. 639
Petty, E. M. (2011) · doi:10.6028/nist.ir.6661-03
NIST time and frequency bulletin, no. 651
Petty, E. M. (2012) · doi:10.6028/nist.ir.6665-03
NIST time and frequency bulletin, no. 626
Petty, E. M. (2010) · doi:10.6028/nist.ir.6658-02
NIST time and frequency bulletin, no. 614
Petty, E. M. (2009) · doi:10.6028/nist.ir.6656-02
NIST time and frequency bulletin, no. 583
Petty, E. M. (2006) · doi:10.6028/nist.ir.6639-07
NIST time and frequency bulletin, no. 622
Petty, E. M. (2009) · doi:10.6028/nist.ir.6656-10
NIST time and frequency bulletin, no. 646
Petty, E. M. (2011) · doi:10.6028/nist.ir.6661-10
NIST time and frequency bulletin, no. 635
Petty, E. M. (2010) · doi:10.6028/nist.ir.6658-11
NIST time and frequency bulletin - februrary
Stephenson, K. R. (2018) · doi:10.6028/nist.ir.8205-02
NIST time and frequency bulletin, no. 628
Petty, E. M. (2010) · doi:10.6028/nist.ir.6658-04
NIST time and frequency bulletin, no. 659
Petty, E. M. (2012) · doi:10.6028/nist.ir.6665-11
NIST time and frequency bulletin: April
Stephenson, K. R. (2017) · doi:10.6028/nist.ir.8167-04
NIST time and frequency bulletin, no. 642
Petty, E. M. (2011) · doi:10.6028/nist.ir.6661-06
NIST time and frequency bulletin, no. 616
Petty, E. M. (2009) · doi:10.6028/nist.ir.6656-04
NIST time and frequency bulletin, no. 631
Petty, E. M. (2010) · doi:10.6028/nist.ir.6658-07
NIST time and frequency bulletin, no. 638
Petty, E. M. (2011) · doi:10.6028/nist.ir.6661-02
NIST time and frequency bulletin, no. 624
Petty, E. M. (2009) · doi:10.6028/nist.ir.6656-12
NIST time and frequency bulletin, no. 606
Petty, E. M. (2008) · doi:10.6028/nist.ir.6653-06
NIST time and frequency bulletin, no. 594
Petty, E. M. (2007) · doi:10.6028/nist.ir.6646-06
NIST time and frequency bulletin, no. 653
Petty, E. M. (2012) · doi:10.6028/nist.ir.6665-05
NIST time and frequency bulletin, no. 637
Petty, E. M. (2011) · doi:10.6028/nist.ir.6661-01
NIST time and frequency bulletin, no. 613
Petty, E. M. (2009) · doi:10.6028/nist.ir.6656-01
NIST time and frequency bulletin, no. 604
Petty, E. M. (2008) · doi:10.6028/nist.ir.6653-04
NIST time and frequency bulletin, no. 596
Petty, E. M. (2007) · doi:10.6028/nist.ir.6646-08
NIST time and frequency bulletin, no. 615
Petty, E. M. (2009) · doi:10.6028/nist.ir.6656-03
NIST time and frequency bulletin, no. 578
Petty, E. M. (2006) · doi:10.6028/nist.ir.6639-02
NIST time and frequency bulletin, no. 612
Petty, E. M. (2008) · doi:10.6028/nist.ir.6653-12
NIST Time and Frequency Bulletin: October
Lichtfuss, K. H. (2016) · doi:10.6028/nist.ir.8104-10
NIST time and frequency bulletin, no. 580
Petty, E. M. (2006) · doi:10.6028/nist.ir.6639-04
NIST time and frequency bulletin, no. 592
Petty, E. M. (2007) · doi:10.6028/nist.ir.6646-04
NIST time and frequency bulletin, no. 608
Petty, E. M. (2008) · doi:10.6028/nist.ir.6653-08
NIST time and frequency bulletin, no. 629
Petty, E. M. (2010) · doi:10.6028/nist.ir.6658-05
NIST time and frequency bulletin, no. 643
Petty, E. M. (2011) · doi:10.6028/nist.ir.6661-07
NIST time and frequency bulletin, no. 660
Petty, E. M. (2012) · doi:10.6028/nist.ir.6665-12
NIST time and frequency bulletin, no. 654
Petty, E. M. (2012) · doi:10.6028/nist.ir.6665-06
NIST Time and Frequency Bulletin: November
Lichtfuss, K. H. (2016) · doi:10.6028/nist.ir.8104-11
NIST Time and Frequency Bulletin: September 2016
Lichtfuss, K. H. (2016) · doi:10.6028/nist.ir.8104-09
NIST time and frequency bulletin, no. 595
Petty, E. M. (2007) · doi:10.6028/nist.ir.6646-07
NIST time and frequency bulletin, no. 605
Petty, E. M. (2008) · doi:10.6028/nist.ir.6653-05
Metadata
- Authors
- Parker, T. E., Jefferts, S. R., Heavner, T. P., & Donley, E. A.
- Affiliations
- National Institute of Standards and Technology (US)
- Venue
- Metrologia
- Publisher
- IOP Publishing
- Published
- 2005-09-13
- Volume
- 42
- Issue
- 5
- Pages
- 423-430
- ISSN
- 0026-1394 (ISSN-L)
- 1681-7575
- OpenAlex
- W2132128253
- Cited by
- 220
- References
- 16
- Citations by year
- 2023: 3 · 2022: 7 · 2021: 13 · 2020: 12 · 2019: 14 · 2018: 12 · 2017: 13 · 2016: 13 · 2015: 11 · 2014: 15 · 2013: 14 · 2012: 11
- FWCI
- 9.42
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Metrologia (publishedVersion)
- Funders
- National Institute of Standards and Technology
- U.S. Naval Observatory
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Electrical Measurement Techniques
- Keywords
- primary frequency standard, hydrogen maser, frequency stability, systematic bias, time and frequency transfer, TAI, uncertainty analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.