Uncertainty evaluation of the caesium fountain clock PTB-CSF2
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The uncertainty evaluation of CSF2, the second caesium fountain primary frequency standard at PTB, is presented. The fountain uses optical molasses to cool atoms down to 0.6 µK. The atoms are launched vertically in a moving optical molasses, and state selected in the | F = 3, m F = 0⟩ hyperfine ground state. During their ballistic flight, the atoms interact twice with a microwave field, thus completing the Ramsey interaction. With a launch height of 36.5 cm above the cavity centre, the central Ramsey fringe has a width of 0.9 Hz. About 3 × 10 4 atoms, 30% of the initial number in the | F = 3, m F = 0⟩ state, are detected after their second interaction with the microwave field. Stabilizing the microwave frequency to the centre of the central Ramsey fringe, a typical relative frequency instability of 2.5 × 10 −13 (τ/s) −1/2 is obtained. The CSF2 systematic uncertainty for realizing the SI second is estimated as 0.80 × 10 −15 . First comparisons with the fountain CSF1 at the Physikalisch-Technische Bundesanstalt and other fountain frequency standards worldwide demonstrate agreement within the stated uncertainties.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
NIST-F1: recent improvements and accuracy evaluations
Heavner, T. P., Jefferts, S. R., Donley, E. A., Shirley, J. H., & Parker, T. E. (2005) · Metrologia · doi:10.1088/0026-1394/42/5/012 · Cited by 355
Cited by
Improved Limit on a Temporal Variation ofmp/mefrom Comparisons ofYb+and Cs Atomic Clocks
Huntemann, N., Lipphardt, B., Tamm, C., Gerginov, V., Weyers, S., & Peik, E. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210802 · Cited by 366
Self-citationA strontium lattice clock with 3 × 10−17inaccuracy and its frequency
Falke, S., Lemke, N., Grebing, C., Lipphardt, B., Weyers, S., Gerginov, V., Huntemann, N., Hagemann, C., Al-Masoudi, A., Häfner, S., et al. (2014) · New Journal of Physics · doi:10.1088/1367-2630/16/7/073023 · Cited by 182
Self-citationRealization of a timescale with an accurate optical lattice clock
Grebing, C., Al-Masoudi, A., Dörscher, S., Häfner, S., Gerginov, V., Weyers, S., Lipphardt, B., Riehle, F., Sterr, U., & Lisdat, C. (2016) · Optica · doi:10.1364/optica.3.000563 · Cited by 149
Self-citationGuéna, J., Weyers, S., Abgrall, M., Grebing, C., Gerginov, V, Rosenbusch, P., Bize, S., Lipphardt, B., Denker, H., Quintin, N., et al. (2017) · Metrologia · doi:10.1088/1681-7575/aa65fe · Cited by 83
Self-citationCs-based optical frequency measurement using cross-linked optical and microwave oscillators
Tamm, C., Huntemann, N., Lipphardt, B., Gerginov, V., Nemitz, N., Kazda, M., Weyers, S., & Peik, E. (2014) · Physical Review A · doi:10.1103/physreva.89.023820 · Cited by 72
Self-citation
Metadata
- Authors
- Gerginov, V, Nemitz, N., Weyers, S., Schröder, R., Griebsch, D., & Wynands, R.
- Venue
- Metrologia
- Publisher
- IOP Publishing
- Published
- 2009-12-22
- Volume
- 47
- Issue
- 1
- Pages
- 65-79
- ISSN
- 0026-1394 (ISSN-L)
- 1681-7575
- OpenAlex
- W1982525534
- Cited by
- 129
- References
- 1
- FWCI
- 5.39
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Uncertainty evaluation of the caesium fountain clock PTB-CSF2. https://app.cochat.ai/papers/10.1088/0026-1394/47/1/008
- The paper
- Gerginov, V, Nemitz, N., Weyers, S., Schröder, R., Griebsch, D., & Wynands, R. (2010). Uncertainty evaluation of the caesium fountain clock PTB-CSF2. Metrologia. https://doi.org/10.1088/0026-1394/47/1/008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.