Generation of UTC(PTB) as a fountain-clock based time scale
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The Physikalisch-Technische Bundesanstalt (PTB) has substantially improved the quality of its local time scale UTC(PTB), which is the national realization of the international time reference Coordinated Universal Time (UTC). It serves as the basis for PTB's time services, for local clock comparisons and for international time comparisons. Since February 2010 UTC(PTB) has been realized using an active hydrogen maser (AHM) steered in frequency via a phase micro-stepper according to an algorithm which combines the frequency comparison data between the AHM and primary and commercial caesium clocks of PTB. Thereby the long-term stability and accuracy of PTB's primary clocks, in particular its fountain clock CSF1, were combined with the short-term frequency stability of the AHM. CSF1 data were used to calculate the steering on all but six days during 15 months. During the time between July 2010 and July 2011, the time difference between UTC(PTB) and UTC was always less than 6 ns and the monthly mean rate differences never exceeded 0.16 ns per day.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Time transfer with nanosecond accuracy for the realization of International Atomic Time
Piester, D., Bauch, A., Breakiron, L., Matsakis, D., Blanzano, B., & Koudelka, O. (2008) · Metrologia · doi:10.1088/0026-1394/45/2/008 · Cited by 143
Self-citationArias, E. F., Panfilo, G., & Petit, G. (2011) · Metrologia · doi:10.1088/0026-1394/48/4/s04 · Cited by 64 · cited 2×
“The decision was made initially to always use d estimated for the previous month and published at the end of Section 4 of Circular T, irrespective of the fact that d depends in a complicated way on the past contributions of several primary frequency standards [5, 15], not always including CSF1.”
Method
Cited by
High Accuracy Correction of Blackbody Radiation Shift in an Optical Lattice Clock
Middelmann, T., Falke, S., Lisdat, C., & Sterr, U. (2012) · Physical Review Letters · doi:10.1103/physrevlett.109.263004 · Cited by 154
Realization of a timescale with an accurate optical lattice clock
Grebing, C., Al-Masoudi, A., Dörscher, S., Häfner, S., Gerginov, V., Weyers, S., Lipphardt, B., Riehle, F., Sterr, U., & Lisdat, C. (2016) · Optica · doi:10.1364/optica.3.000563 · Cited by 149
Self-citationSchioppo, M., Kronjäger, J., Silva, A., Ilieva, R., Paterson, J. W., Baynham, C. F. A., Bowden, W., Hill, I. R., Hobson, R., Vianello, A., et al. (2022) · Nature Communications · doi:10.1038/s41467-021-27884-3 · Cited by 118
Guéna, J., Weyers, S., Abgrall, M., Grebing, C., Gerginov, V, Rosenbusch, P., Bize, S., Lipphardt, B., Denker, H., Quintin, N., et al. (2017) · Metrologia · doi:10.1088/1681-7575/aa65fe · Cited by 83
Self-citationMonths-long real-time generation of a time scale based on an optical clock
Hachisu, H., Nakagawa, F., Hanado, Y., & Ido, T. (2018) · Scientific Reports · doi:10.1038/s41598-018-22423-5 · Cited by 83
Metadata
- Authors
- Bauch, A., Weyers, S., Piester, D., Staliuniene, E., & Yang, W.
- Venue
- Metrologia
- Publisher
- IOP Publishing
- Published
- 2012-01-27
- Volume
- 49
- Issue
- 3
- Pages
- 180-188
- ISSN
- 0026-1394 (ISSN-L)
- 1681-7575
- OpenAlex
- W2024525062
- Cited by
- 104
- References
- 2
- FWCI
- 2.82
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.