CoChat

High Accuracy Correction of Blackbody Radiation Shift in an Optical Lattice Clock

Open access
Middelmann, Thomas, Falke, Stephan, Lisdat, Christian, Sterr, Uwe · 2012 · Physical Review Letters
Cited by 154

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

We have determined the frequency shift that blackbody radiation is inducing on the $5{s}^{2}$ $^{1}S_{0}--5s5p$ $^{3}P_{0}$ clock transition in strontium. Previously its uncertainty limited the uncertainty of strontium lattice clocks to $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}16}$. Now the uncertainty associated with the blackbody radiation shift correction translates to a $5\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}18}$ relative frequency uncertainty at room temperature. Our evaluation is based on a measurement of the differential dc polarizability of the two clock states and on a modeling of the dynamic contribution using this value and experimental data for other atomic properties.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1103/physrevlett.109.263004

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Research works printed but not linked: 28

  1. 10.1038/nphoton.2011.34 · DOI · Paper page
  2. 10.1103/PhysRevLett.93.170801 · DOI · Paper page
  3. 10.1139/p08-053 · DOI
  4. 10.1103/PhysRevLett.100.140801 · DOI · Paper page
  5. 10.1038/nphoton.2011.45 · DOI · Paper page
  6. 10.1088/0026-1394/45/5/008 · DOI
  7. 10.1103/PhysRevLett.108.153002 · DOI
  8. 10.1140/epjd/e2007-00330-3 · DOI · Paper page
  9. 10.1143/APEX.4.082203 · DOI
  10. 10.1103/PhysRevA.78.032508 · DOI
  11. 10.1103/PhysRevA.57.436 · DOI · Paper page
  12. 10.1109/TUFFC.2010.1455 · doi:10.1109/tuffc.2010.1455
  13. 10.1088/1367-2630/14/7/073020 · DOI
  14. 10.1109/TIM.2008.2007042 · DOI
  15. P. Franke, 2010, PTB Mitteilungen, 120, 16
  16. 10.1103/PhysRevA.72.062111 · DOI · Paper page
  17. 10.1088/0264-9381/23/7/026 · doi:10.1088/0264-9381/23/7/026
  18. 10.1063/1.323539 · DOI · Paper page
  19. 10.1109/TIM.2010.2088470 · DOI · Paper page
  20. E. U. Condon, 1953, The Theory of Atomic Spectra
  21. 10.1103/PhysRevA.70.023414 · DOI
  22. 10.1103/PhysRevA.86.029904 · DOI
  23. 10.1088/0953-4075/24/18/019 · doi:10.1088/0953-4075/24/18/019
  24. 10.1007/BF01437201 · doi:10.1007/bf01437201
  25. 10.1103/PhysRevA.28.2051 · doi:10.1103/physreva.28.2051
  26. 10.1103/PhysRevC.32.2058 · doi:10.1103/physrevc.32.2058
  27. 10.1007/BF01411600 · doi:10.1007/bf01411600
  28. 10.1063/1.3077727 · doi:10.1063/1.3077727

Cited by

See all 154

Metadata

Authors
Middelmann, T., Falke, S., Lisdat, C., & Sterr, U.
Venue
Physical Review Letters
Published
2012-12-27
Volume
109
Issue
26
Pages
263004-263004
ISSN
  • 0031-9007 (ISSN-L)
  • 1079-7114
OpenAlex
W2058209208
Cited by
154
References
9
FWCI
8.47
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High Accuracy Correction of Blackbody Radiation Shift in an Optical Lattice Clock. https://app.cochat.ai/papers/10.1103/physrevlett.109.263004
The paper
Middelmann, T., Falke, S., Lisdat, C., & Sterr, U. (2012). High Accuracy Correction of Blackbody Radiation Shift in an Optical Lattice Clock. Physical Review Letters. https://doi.org/10.1103/physrevlett.109.263004

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.