The DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.
First accuracy evaluation of NIST-F2
Open accessAbstract
We report the first accuracy evaluation of NIST-F2, a second-generation laser-cooled caesium fountain primary standard developed at the National Institute of Standards and Technology (NIST) with a cryogenic (liquid nitrogen) microwave cavity and flight region. The 80 K atom interrogation environment reduces the uncertainty due to the blackbody radiation shift by more than a factor of 50. Also, the Ramsey microwave cavity exhibits a high quality factor (>50 000) at this low temperature, resulting in a reduced distributed cavity phase shift. NIST-F2 has undergone many tests and improvements since we first began operation in 2008. In the last few years NIST-F2 has been compared against a NIST maser time scale and NIST-F1 (the US primary frequency standard) as part of in-house accuracy evaluations. We report the results of nine in-house comparisons since 2010 with a focus on the most recent accuracy evaluation. This paper discusses the design of the physics package, the laser and optics systems and the accuracy evaluation methods. The type B fractional uncertainty of NIST-F2 is shown to be 0.11 × 10 −15 and is dominated by microwave amplitude dependent effects. The most recent evaluation (August 2013) had a statistical (type A) fractional uncertainty of 0.44 × 10 −15 .
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Microwave clocks were improved by three orders of magnitude in the past decades, now approaching the level of 10−16 (Heavner et al. 2014), see also Fig. 4.”
From Clock networks for height system unification: a simulation study (2019) · cites this paper as Heavner et al. 2014
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Happer, W. (1972) · Reviews of Modern Physics · doi:10.1103/revmodphys.44.169 · Cited by 1,720
Spin-exchange optical pumping of noble-gas nuclei
Walker, T. G., & Happer, W. (1997) · Reviews of Modern Physics · doi:10.1103/revmodphys.69.629 · Cited by 1,461
The Quantum Physics of Atomic Frequency Standards
Vanier, J., & Audoin, C. (1989) · Institute of Physics eBooks · doi:10.1887/085274434x · Cited by 624
The Quantum Physics of Atomic Frequency Standards
Vanier, J., & Tomescu, C. (2015) · CRC Press eBooks · doi:10.1201/b18738 · Cited by 554
Accuracy evaluation of NIST-F1
Jefferts, S. R., Shirley, J. H., Parker, T. E., Heavner, T. P., Meekhof, D. M., Nelson, C. W., Levi, F., Costanzo, G. A., Marchi, A. D., Drullinger, R. E., et al. (2002) · Metrologia · doi:10.1088/0026-1394/39/4/1 · Cited by 402
Self-citationWynands, R., & Weyers, S. (2005) · Metrologia · doi:10.1088/0026-1394/42/3/s08 · Cited by 374
NIST-F1: recent improvements and accuracy evaluations
Heavner, T. P., Jefferts, S. R., Donley, E. A., Shirley, J. H., & Parker, T. E. (2005) · Metrologia · doi:10.1088/0026-1394/42/5/012 · Cited by 355
Self-citationProgress in atomic fountains at LNE-SYRTE
Guéna, J., Abgrall, M., Rovera, D., Laurent, P., Chupin, B., Lours, M., Santarelli, G., Rosenbusch, P., Tobar, M. E., Li, R., et al. (2012) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2012.2208 · Cited by 291
Moldover, M. R., Gavioso, R. M., Mehl, J. B., Pitre, L., de Podesta, M., & Zhang, J. (2014) · Metrologia · doi:10.1088/0026-1394/51/1/r1 · Cited by 246
Double-pass acousto-optic modulator system
Donley, E. A., Heavner, T. P., Levi, F., Tataw, M. O., & Jefferts, S. R. (2005) · Review of Scientific Instruments · doi:10.1063/1.1930095 · Cited by 237
Self-citation
Research works printed but not linked: 8
- Heavner T P, 2008, Proc. 2008 Symp. Frequency Standards and Metrology, 299
- Jefferts S R, 2003, Proc. 2003 Joint Meeting IEEE Int. Frequency Control Symp. and EFTF Conf., 1084
- Donley E A, 2005, Proc. 2005 Joint Meeting IEEE Int. Frequency Control Symp. and PTTI, 292
- Heavner T P, 2011, Proc. 2011 Joint Meeting IEEE Int. Frequency Control Symp. and EFTF Conf., 48
- Heavner T P, 2005, Proc. 2005 Joint Meeting IEEE Int. Frequency Control Symp. and PTTI, 308
- Shirley J H, 2003, Proc. 2003 Joint Meeting IEEE Int. Frequency Control Symp. and EFTF Conf., 1072
- Jefferts S R, 2005, Proc. 2005 Joint Meeting IEEE Int. Frequency Cont. Symp. and PTTI, 105
- Weyers S, 2006, Proc. 2006 EFTF, 173
Cited by
Sorted by citations
Items 101–200 of 204
Ticking-clock performance enhanced by nonclassical temporal correlations
Budroni, C., Vitagliano, G., & Woods, M. P. (2021) · Repository for Publications and Research Data (ETH Zurich) · doi:10.3929/ethz-b-000501111 · Cited by 7
Uncertainty evaluation of the caesium fountain primary frequency standard NIM6
Zheng, F., Chen, W., Liu, K., Dai, S., Liu, N., Wang, Y., & Fang, F. (2025) · Metrologia · doi:10.1088/1681-7575/add9a7 · Cited by 6
Comment on ‘First accuracy evaluation of NIST-F2’
Gibble, K. (2015) · Metrologia · doi:10.1088/0026-1394/52/1/163 · Cited by 6
Development of Rb fountain clock for time keeping
Weiliang, C., Fang, F., Liu, K., Fasong, Z., Dai, S., Zuo, Y., & Li, T. (2022) · Frontiers in Physics · doi:10.3389/fphy.2022.956452 · Cited by 6
Status of the atomic fountain clock at the National Research Council of Canada
Beattie, S., Alcock, J. A., Jian, B., Gertsvolf, M., & Bernard, J. E. (2016) · Journal of Physics Conference Series · doi:10.1088/1742-6596/723/1/012008 · Cited by 6
Drift-Compensated Low-Noise Frequency Synthesis Based on a cryoCSO for the KRISS-F1
Heo, M.-S., Park, S. E., Lee, W.-K., Lee, S.-B., Hong, H.-G., Kwon, T. Y., Park, C. Y., Yu, D.-H., Santarelli, G., Hilton, A. P., et al. (2016) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2016.2620187 · Cited by 6
Advances in the NIM Cs fountain clocks
Fang, F., Chen, W., Liu, K., Dai, S., Liu, N., Han, L., Zheng, F., & Li, T. (2019) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/fcs.2019.8856067 · Cited by 6
Wang, Q., Zhang, N., Zhao, W., Ji, Q., Dong, R., Wei, R., & Wang, Y. (2020) · Journal of the Optical Society of America B · doi:10.1364/josab.390249 · Cited by 6
Evaluation of second-order Zeeman frequency shift in NTSC-F2*
Shi, J., Wang, X., Bai, Y., Yang, F., Guan, Y., Liu, D., Ruan, J., & Zhang, S. (2021) · Chinese Physics B · doi:10.1088/1674-1056/abe375 · Cited by 6
Beattie, S., & Jian, B. (2023) · Metrologia · doi:10.1088/1681-7575/acda32 · Cited by 5
Nuclear deformation effects in the spectra of highly charged ions
Sun, Z., Valuev, I. A., & Oreshkina, N. S. (2024) · Physical Review Research · doi:10.1103/physrevresearch.6.023327 · Cited by 5
A review of the lunar laser ranging technique and contribution of timing systems
Munghemezulu, C., Combrinck, L., & Botai, J. O. (2016) · South African Journal of Science · doi:10.17159/sajs.2016/20150400 · Cited by 5
Operation of NIM5 fountain with 1.5x10-15uncertainty and design of new NIM6 in NIM
Fang, F., Liu, N., Liu, K., Chen, W., Suo, R., & Li, T. (2016) · Journal of Physics Conference Series · doi:10.1088/1742-6596/723/1/012009 · Cited by 5
Indigenisation of the Quantum Clock: An Indispensable Tool for Modern Technologies
De, S., & Sharma, A. (2023) · Atoms · doi:10.3390/atoms11040071 · Cited by 5
The history of time and frequency from antiquity to the present day
Levine, J. (2016) · The European Physical Journal H · doi:10.1140/epjh/e2016-70004-3 · Cited by 5
QSNET, a network of clocks for measuring the stability of fundamental constants
Barontini, G., Boyer, V., Xavier Calmet, A., Fitch, N. J., Forgan, E. M., Godun, R. M., Goldwin, J., Guarrera, V., Hill, I. R., Jeong, M., et al. (2021) · Sussex Research Online (University of Sussex) · doi:10.48550/arxiv.2110.05944 · Cited by 5
Femtosecond-comb based 10 MHz-to-optical frequency link with uncertainty at the 10 −18 level
Wada, M., & Inaba, H. (2022) · Metrologia · doi:10.1088/1681-7575/ac938d · Cited by 5
Distortion of Rabi oscillations in a compact cold-atom clock
Ouyang, X., Yang, B., Hu, Q., Qi, H.-H., Xiao, L., Wan, J., & Cheng, H.-D. (2021) · Physical Review A · doi:10.1103/physreva.103.043118 · Cited by 4
Jiang, K., Cheng, J., & He, L. (2019) · Wuhan University Journal of Natural Sciences · doi:10.1007/s11859-019-1416-4 · Cited by 4
Microwave-Vacuum Integrated Cavity with a Low Temperature Sensitivity for Cs Fountain Clocks
Zheng, F., Fang, F., Chen, W., Liu, K., Dai, S., Cao, S., & Li, T. (2021) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/eftf/ifcs52194.2021.9604254 · Cited by 4
Elimination of spatial Rabi frequency modulation by sideband suppression with a calcite crystal
Maldonado, M. A., Pimenta, W. M., Franco-Villafañe, J. A., & Gómez, E. (2021) · Applied Physics B · doi:10.1007/s00340-021-07717-3 · Cited by 4
Improvement of average magnetic field measurement based on magnetic-field-sensitive Ramsey fringes
Zhao, W., Wang, Q., Lv, D., & Wei, R. (2022) · Optics Letters · doi:10.1364/ol.455269 · Cited by 4
A cold cesium beam source based on a two-dimensional magneto-optical trap
Xie, W., Wang, Q., He, X., Fang, S., Yuan, Z., Qi, X., & Chen, X. (2022) · AIP Advances · doi:10.1063/5.0099415 · Cited by 4
An active optical frequency reference using a pulsed superradiant laser
Silva, J. M., Cline, J., Thompson, J. K., & Norcia, M. A. (2019) · Optical and Quantum Sensing and Precision Metrology II · doi:10.1117/12.2515582 · Cited by 4
QSNET, a network of clock for measuring the stability of fundamental constants
Barontini, G., Boyer, V., Calmet, X., Fitch, N. J., Forgan, E. M., Godun, R. M., Goldwin, J., Guarrera, V., Hill, I. R., Jeong, M., et al. (2021) · Quantum Technology: Driving Commercialisation of an Enabling Science · doi:10.1117/12.2600493 · Cited by 9
Towards Adoption of an Optical Second: Verifying Optical Clocks at the SI LimitPreprint
McGrew, W. F., Zhang, X., Leopardi, H., Fasano, R., Nicolodi, D., Beloy, K., Yao, J., Sherman, J. A., Schäffer, S. A., Savory, J., et al. (2018) · arXiv (Cornell University) · doi:10.48550/arxiv.1811.05885 · Cited by 4
Self-citation中国光学十大进展:超冷中性原子光钟及其量子参考体系囚禁方案(特邀)
Yanhua, 周. Z., Chang, H., & Tao, 汪. W. (2024) · Laser & Optoelectronics Progress · doi:10.3788/lop232669 · Cited by 3
Quantum sensing using atomic clocks for nuclear and particle physics
Kawasaki, A. (2025) · Applied Physics Reviews · doi:10.1063/5.0273813 · Cited by 4
Comparison of the sensitivities for atom interferometers in two different operation methods
Duan, X., Mao, D., Deng, X.-B., Zhou, M.-K., Shao, C.-G., Zhu, Z., & Hu, Z.-K. (2018) · Chinese Physics B · doi:10.1088/1674-1056/27/1/013701 · Cited by 3
Optimization of Operation Parameters in a Cesium Atomic Fountain Clock Using Monte Carlo Method
Li, H., Du, Y., Yang, X., Guo, Y., Liu, M., Li, W., Liu, H., & Lu, Z. H. (2021) · IEEE Access · doi:10.1109/access.2021.3113161 · Cited by 3
An optically pumped atomic clock based on a continuous slow cesium beam
Xie, W., Wang, Q., He, X., Yuan, Z., Fang, S., Chen, N., Xiong, Z., Zhang, J., Qi, X., Li, S., et al. (2022) · Frontiers in Physics · doi:10.3389/fphy.2022.1073854 · Cited by 3
Magnetic-field-sensitive multi-wave interference
Yan, W., Ren, X., Xu, W., Hu, Z.-K., & Zhou, M.-K. (2023) · Frontiers of Physics · doi:10.1007/s11467-023-1300-8 · Cited by 3
Guodong, 赵. Z., Lu, X., & Chang, H. (2023) · Laser & Optoelectronics Progress · doi:10.3788/lop223237 · Cited by 3
Automation of an optical frequency standard experiment
Batra, N., Roy, A., Samal, C., Majhi, S., Panja, S., & De, S. (2016) · International Conference on Control, Instrumentation, Energy & Communication · doi:10.1109/ciec.2016.7513823 · Cited by 3
The optically generated microwave oscillator with long-term stability locked at hydrogen maser
Dai, S., Fang, F., Liu, K., Chen, W., Liu, N., Cao, S., & Li, T. (2020) · AIP Advances · doi:10.1063/5.0003839 · Cited by 3
Accurate Evaluation of Microwave-Leakage-Induced Frequency Shifts in Fountain Clocks
Fang, F., Liu, K., Chen, W., Liu, N., Suo, R., & Li, T.-C. (2014) · Chinese Physics Letters · doi:10.1088/0256-307x/31/10/100601 · Cited by 3
Building a better atomic clock
Bloom, B. (2013) · Physics Today · doi:10.1063/pt.5.027159 · Cited by 4
Space qualified microwave source for cold atom clock operating in orbit
Li, T., Huang, J., Qu, Q., Wang, B., Lin, L., Ren, W., Shi, W., Zhao, J.-B., Zhao, X., Ji, J.-W., et al. (2018) · Review of Scientific Instruments · doi:10.1063/1.5048848 · Cited by 3
100-ns-level timing holdover after 12 years for rubidium atomic fountains
Peil, S., Akin, T. G., & Whalen, J. D. (2025) · Physical Review Applied · doi:10.1103/61yv-3ltl · Cited by 2
Development and tuning of the microwave resonant cavity of a cryogenic cesium atomic fountain clock
Yang, F., Wang, X., Fan, S., Bai, Y., Shi, J., Liu, D., Zhang, H., Guan, Y., Hao, Q., Ruan, J., et al. (2022) · Review of Scientific Instruments · doi:10.1063/5.0082708 · Cited by 2
Accurate temperature measurement of cold atoms in cesium fountain clocks
Medina-Herrera, A., Ortiz, C. A., de Carlos-Lopez, E., & López-Romero, J. M. (2022) · Optics Express · doi:10.1364/oe.461360 · Cited by 2
Arora, P., & Gupta, A. S. (2023) · Springer eBooks · doi:10.1007/978-981-99-2074-7_21 · Cited by 2
Systematic Effects in Atomic Fountain Clocks
Gibble, K. (2016) · Journal of Physics Conference Series · doi:10.1088/1742-6596/723/1/012002 · Cited by 2
The progress of the NIM6 fountain clock in NIM
Fang, F., Chen, W., Liu, K., Liu, N., Dai, S., Han, L., & Li, T. (2017) · URSI General Assembly and Scientific Symposium · doi:10.23919/ursigass.2017.8105340 · Cited by 2
Three-Dimensional Paul Trap with High Secular Frequency for Compact Optical Clock
Semerikov, I. A., Zalivako, I. V., Borisenko, A. S., Aksenov, M. A., Vishnyakov, P., Sidorov, P., Колачевский, Н. Н., & Khabarova, K. Y. (2019) · Bulletin of the Lebedev Physics Institute · doi:10.3103/s1068335619090070 · Cited by 2
Ji, Q., Zhao, W., Wang, Y., & Wei, R. (2021) · Journal of the Optical Society of America B · doi:10.1364/josab.415603 · Cited by 2
The caesium fountain clock at the NRC
Beattie, S., Jian, B., Alcock, J. A., & Gertsvolf, M. (2022) · Canadian Journal of Physics · doi:10.1139/cjp-2022-0175 · Cited by 2
Guan, Y., Liu, D., Wang, X., Zhang, H., Shi, J., Bai, Y., Ruan, J., & Zhang, S. (2020) · Acta Physica Sinica · doi:10.7498/aps.69.20191800 · Cited by 2
Interrogation of optical Ramsey spectrum and stability study of an 87Sr optical lattice clock
Xia, J., Lu, X., & Chang, H. (2021) · Chinese Physics B · doi:10.1088/1674-1056/ac11e0 · Cited by 2
Hollberg, L. W. (2020) · Wiley eBooks · doi:10.1002/9781119458555.ch47 · Cited by 3
Arora, P., & Gupta, A. S. (2022) · Springer eBooks · doi:10.1007/978-981-19-1550-5_21-1 · Cited by 2
Cao, S., Lin, B., Han, Y., & Fang, Z. (2022) · Optics Communications · doi:10.1016/j.optcom.2022.128792 · Cited by 1
Stability analysis in an optical lattice clock using the four-path measurement
Lu, X., Guo, F., Xia, J., Liu, Y., Lu, B., & Chang, H. (2024) · Physical Review A · doi:10.1103/physreva.109.023111 · Cited by 1
Optical System for Time-Keeping 87Rb Fountain Clock
Zhang, H., Chen, J., Liu, D., Fan, S., Bai, Y., Guan, Y., Ruan, J., & Zhang, S. (2024) · European Frequency and Time Forum · doi:10.1109/eftf61992.2024.10722578 · Cited by 1
Preliminary Results of the Portable Cold 87Rb Atomic Clock in NIM
Zheng, F., Liu, K., Chen, W., Dai, S., & Fang, F. (2024) · European Frequency and Time Forum · doi:10.1109/eftf61992.2024.10722244 · Cited by 1
Towards Bose–Einstein Condensate with laser-cooled molecules
Zeng, Z., & Yan, B. (2025) · Quantum Review Letters · doi:10.1016/j.qrl.2025.03.001 · Cited by 1
Tasks of Information-Measuring Systems’ Functioning
Babak, V. P., Babak, S. V., Eremenko, V. S., Kuts, Y. V., & Zaporozhets, A. O. (2025) · Studies in systems, decision and control · doi:10.1007/978-3-031-89406-0_1 · Cited by 1
Resolving the Hubble tension 68.261 and 73.510 km s−1 Mpc−1
Geiger, J. A. (2025) · AIP Advances · doi:10.1063/5.0269029 · Cited by 1
Utilising diffractive optics towards a compact, cold atom clock
McGilligan, J. P., Elvin, R., Griffin, P. F., Riis, E., & Arnold, A. S. (2016) · European Frequency and Time Forum · doi:10.1109/eftf.2016.7477809 · Cited by 1
Measurement of the Microwave Lensing shift in NIST-F1 and NIST-F2
Jefferts, S. R., Heavner, T. P., Barlow, S. E., & Ashby, N. (2016) · Journal of Physics Conference Series · doi:10.1088/1742-6596/723/1/012005 · Cited by 1
Self-citationDrift-compensated low-noise frequency synthesis based on a CryoCSO for the KRISS-F1(Cs)
Heo, M.-S., Park, S. E., Lee, S.-B., Hong, H.-G., Kwon, T. Y., Park, C. Y., Lee, W.-K., Yu, D.-H., & Hartnett, J. G. (2016) · Conference on Precision Electromagnetic Measurements · doi:10.1109/cpem.2016.7540695 · Cited by 1
Transportable Clocks Move with the Times
Godun, R. M. (2017) · Physics · doi:10.1103/physics.10.11 · Cited by 1
New Technologies and the Future of Timekeeping
Arias, E. F. (2017) · Astrophysics and space science proceedings · doi:10.1007/978-3-319-59909-0_42 · Cited by 1
New Physics Searches Using Precision Spectroscopy
Orzel, C. (2018) · Advances in atomic, molecular, and optical physics · doi:10.1016/bs.aamop.2018.02.001 · Cited by 1
Frequency comparisons of Sr, Yb, and Hg based optical lattice clocks and their applications
Katori, H., Ushijima, I., Das, M., Nemitz, N., Ohkubo, T., Yamanaka, K., Ohmae, N., Takano, T., Akatsuka, T., Yamaguchi, A., et al. (2015) · Conference on Lasers and Electro-Optics · doi:10.1364/cleo_si.2015.sf1l.1 · Cited by 1
Modern Timekeeping and the Development of the Science of Time
Penprase, B. E. (2017) · Springer eBooks · doi:10.1007/978-3-319-52597-6_6 · Cited by 1
The ultra-stable microwave based on ultra-stable laser
Dai, S., Fang, F., Cao, S., Liu, K., Liu, N., Chen, W., & Li, T. (2018) · Tenth International Conference on Information Optics and Photonics · doi:10.1117/12.2505864 · Cited by 1
P-TimeSync: A Precise Time Synchronization Simulation with Network Propagation Delays
Dai, W., Zhang, R., & Liu, J. (2024) · IEEE World Forum on Public Safety Technology (WF-PST) · doi:10.1109/wfpst58552.2024.00031 · Cited by 1
The ultra-stable microwave based on ultra-stable laser
Dai, S., Fang, F., Cao, S., Liu, N., & Li, T. (2017) · doi:10.1117/12.2284763 · Cited by 1
Experimental Evaluation of the Blackbody Radiation Shift in the Cesium Atomic Fountain Clock
Yang, F., Wang, X., Ruan, J., Shi, J., Fan, S., Bai, Y., Guan, Y., Hao, Q., Zhang, H., Liu, D., et al. (2022) · Applied Sciences · doi:10.3390/app12010510 · Cited by 1
A Low Temperature-Sensitive Ramsey Cavity for Rb Fountain Clocks
Zheng, F., Fang, F., Xiumei, 王. W., Chen, W., Liu, K., Dai, S., Cao, S., Zuo, Y., & Li, T. (2022) · Lecture notes in electrical engineering · doi:10.1007/978-981-19-2576-4_35 · Cited by 1
Gibble, K. (2015) · Physical Review A · doi:10.1103/physreva.91.067602 · Cited by 1
Zuhrianda, Z. (2024) · Library, Museums and Press - UDSpace (University of Delaware) · doi:10.58088/0rs1-v784 · Cited by 1
An atomic clock for 10-18 timekeeping
Hinkley, N. (2016) · CU Scholar (University of Colorado Boulder) · Cited by 1
Development of a Cesium Fountain Clock at HUST: Preliminary ResultsPreprint
Li, H., Du, Y., Liu, H., Guo, Y., Liu, M., Li, W., & Lu, Z. H. (2021) · arXiv (Cornell University) · doi:10.48550/arxiv.2110.09703 · Cited by 1
Microwave Frequency Standards Using New Physics
(2015) · CRC Press eBooks · doi:10.1201/b18738-4
Status of the Cs fountain clock at the national research council of Canada
Beattie, S., Alcock, J. A., Jian, B., Bernard, J. E., & Gertsvolf, M. (2016) · Conference on Precision Electromagnetic Measurements · doi:10.1109/cpem.2016.7540694
Networked system of crystal oscillators
Reeves, S. I. (2016) · California State University ScholarWorks (system-wide DSpace)
Viewpoint: Transportable Clocks Move with the Times
Godun, R. M. (2017)
Recent progress of development of cesium fountain primary frequency standard NMIJ-F2
Takamizawa, A., Yanagimachi, S., Hagimoto, K., Hirano, I., & Ikegami, T. (2018) · European Frequency and Time Forum · doi:10.1109/eftf.2018.8409006
The ultra-stable microwave based on ultra-stable laser with robustness and long term stability
Dai, S., Fang, F., Liu, K., Cao, S., Liu, N., Chen, W., & Li, T. (2018) · SPIE Conference on Quantum and Nonlinear Optics · doi:10.1117/12.2500185
Development of compact & affordable network time display device
Sardar, S., Bharath, V., Poudel, N., Goel, S., Yadav, S., Arora, P., & Ojha, V. N. (2019) · URSI Asia-Pacific Radio Science Conference · doi:10.23919/ursiap-rasc.2019.8738321
Oscillator metrology with software defined radioPreprint
Sherman, J. A., & Jördens, R. (2016) · arXiv (Cornell University) · doi:10.48550/arxiv.1605.03505
Essentials of Optical Radiation Metrology
Sapritsky, V. I., & Prokhorov, A. V. (2020) · Springer series in measurement science and technology · doi:10.1007/978-3-030-57789-6_2
Relativistic Particle Motion and Quantum Optics in a Weak Gravitational FieldPreprint
Anastopoulos, C., & Hu, B. L. (2021) · arXiv (Cornell University) · doi:10.48550/arxiv.2106.12514
Microwave Frequency Standards Using New Physics
Vanier, J., & Tomescu, C. (2015) · CRC Press eBooks · doi:10.1201/b18738-7
Realization of the SI Second: Thermal Beam Cs Clock, Laser Cooling, and the Cs Fountain Clock
Göbel, E. E., & Siegner, U. (2019) · doi:10.1002/9783527814480.ch3
Zhenyuan, 胡. H., Yaoli, 岳. Y., Yanyan, 张. Z., Shuaihe, 高. G., Xiguang, 杨. Y., Ming, 眭. S., Zhibing, 潘. P., Zhang, S., & Yang, 李. L. (2023) · ACTA PHOTONICA SINICA · doi:10.3788/gzxb20235201.0106002
Cesium Fountain Primary Frequency Standard NMIJ-F2 with Uncertainty Evaluated
Takamizawa, A., Yanagimachi, S., & Hagimoto, K. (2023) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/eftf/ifcs57587.2023.10272165
Einstein’s Concept of Clock Synchronization Conflicts with the Second Relativity Postulate
Deines, S. D. (2024) · Journal of Modern Physics · doi:10.4236/jmp.2024.157041
Re-evaluation of the NRC-FCs2 Fountain Clock
Beattie, S., Jian, B., & Gertsvolf, M. (2024) · Journal of Physics Conference Series · doi:10.1088/1742-6596/2889/1/012038 · Cited by 1
Development of commercial fountain clocks in NIM
Liu, K., Zheng, F., Chen, W., Yacong, X., Dai, S., & Fang, F. (2024) · Journal of Physics Conference Series · doi:10.1088/1742-6596/2889/1/012046
Realization of the Compact Magneto-Optical Trap Based on Single Laser with Frequency Modulation
Bao, S., Wu, B., Cao, P., Guo, X., Zhao, Y., Li, D., Niu, J., Zhang, C., Cheng, B., Weng, K., et al. (2025) · Photonics · doi:10.3390/photonics12020098
Performance Estimation of UTC and Several UTC(k) Realizations During the Past 25 Years
Ortiz, C. A., de Carlos-Lopez, E., Medina-Herrera, A., Lombardi, M. A., & López-Romero, J. M. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3551463
Research progress on precision measurement based on optical clocks
Xiaotong, L., Jin, C., & Hong, C. S. (2025) · Acta Physica Sinica · doi:10.7498/aps.75.20251594 · Cited by 1
Tiantian, 史. S., Mengyuan, 韩. H., Jia, 张. Z., Xiaomin, 秦. Q., Xiaolei, 关. G., Xun, 高. G., Ruihang, 陈. C., & Chen, J. (2025) · Acta Optica Sinica (Online) · doi:10.3788/aosol250533
Macroscopicity of quantum superpositionPreprint
Peng, X.-F. (2026) · SSRN Electronic Journal · doi:10.2139/ssrn.6300778
Chirality and nonlinear dynamics in polariton microresonators
Zambon, N. C. (2020) · theses.fr (ABES) · doi:10.70675/6159fd93zb019z44cdz9bb6z33d42b65afef · Cited by 1
Liu, Z., Wang, Q., Li, Y., & Wei, R. (2026) · Quantum Review Letters · doi:10.1016/j.qrl.2026.04.001
Metadata
- Authors
- Heavner, T. P., Donley, E. A., Levi, F., Costanzo, G., Parker, T. E., Shirley, J. H., Ashby, N., Barlow, S., & Jefferts, S. R.
- Affiliations
- National Institute of Standards and Technology (US)
- Istituto Nazionale di Ricerca Metrologica (IT)
- Politecnico di Torino (IT)
- Corresponding author
- Heavner, Thomas P
- Venue
- Metrologia
- Publisher
- IOP Publishing
- Published
- 2014-05-01
- Volume
- 51
- Issue
- 3
- Pages
- 174-182
- ISSN
- 0026-1394 (ISSN-L)
- 1681-7575
- OpenAlex
- W2162126832
- Cited by
- 205
- References
- 47
- Citations by year
- 2026: 4 · 2025: 11 · 2024: 14 · 2023: 12 · 2022: 18 · 2021: 20 · 2020: 20 · 2019: 19 · 2018: 24 · 2017: 13 · 2016: 27 · 2015: 17 · 2014: 4
- FWCI
- 10.12
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- Metrologia (publishedVersion)
- PORTO@Iris (submittedVersion, other-oa)
- PORTO Publications Open Repository TOrino (Politecnico di Torino) (submittedVersion, other-oa)
- CINECA IRIS Institutional Research Information System (IRIS Istituto Nazionale di Ricerca Metrologica) (submittedVersion)
- Funders
- Istituto Nazionale di Ricerca Metrologica
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Electrical Measurement Techniques
- Keywords
- laser cooling, blackbody radiation shift, type B uncertainty, type A uncertainty
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review