The DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.
First accuracy evaluation of NIST-F2
Open accessAbstract
We report the first accuracy evaluation of NIST-F2, a second-generation laser-cooled caesium fountain primary standard developed at the National Institute of Standards and Technology (NIST) with a cryogenic (liquid nitrogen) microwave cavity and flight region. The 80 K atom interrogation environment reduces the uncertainty due to the blackbody radiation shift by more than a factor of 50. Also, the Ramsey microwave cavity exhibits a high quality factor (>50 000) at this low temperature, resulting in a reduced distributed cavity phase shift. NIST-F2 has undergone many tests and improvements since we first began operation in 2008. In the last few years NIST-F2 has been compared against a NIST maser time scale and NIST-F1 (the US primary frequency standard) as part of in-house accuracy evaluations. We report the results of nine in-house comparisons since 2010 with a focus on the most recent accuracy evaluation. This paper discusses the design of the physics package, the laser and optics systems and the accuracy evaluation methods. The type B fractional uncertainty of NIST-F2 is shown to be 0.11 × 10 −15 and is dominated by microwave amplitude dependent effects. The most recent evaluation (August 2013) had a statistical (type A) fractional uncertainty of 0.44 × 10 −15 .
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Microwave clocks were improved by three orders of magnitude in the past decades, now approaching the level of 10−16 (Heavner et al. 2014), see also Fig. 4.”
From Clock networks for height system unification: a simulation study (2019) · cites this paper as Heavner et al. 2014
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Happer, W. (1972) · Reviews of Modern Physics · doi:10.1103/revmodphys.44.169 · Cited by 1,720
Spin-exchange optical pumping of noble-gas nuclei
Walker, T. G., & Happer, W. (1997) · Reviews of Modern Physics · doi:10.1103/revmodphys.69.629 · Cited by 1,461
The Quantum Physics of Atomic Frequency Standards
Vanier, J., & Audoin, C. (1989) · Institute of Physics eBooks · doi:10.1887/085274434x · Cited by 624
The Quantum Physics of Atomic Frequency Standards
Vanier, J., & Tomescu, C. (2015) · CRC Press eBooks · doi:10.1201/b18738 · Cited by 554
Accuracy evaluation of NIST-F1
Jefferts, S. R., Shirley, J. H., Parker, T. E., Heavner, T. P., Meekhof, D. M., Nelson, C. W., Levi, F., Costanzo, G. A., Marchi, A. D., Drullinger, R. E., et al. (2002) · Metrologia · doi:10.1088/0026-1394/39/4/1 · Cited by 402
Self-citationWynands, R., & Weyers, S. (2005) · Metrologia · doi:10.1088/0026-1394/42/3/s08 · Cited by 374
NIST-F1: recent improvements and accuracy evaluations
Heavner, T. P., Jefferts, S. R., Donley, E. A., Shirley, J. H., & Parker, T. E. (2005) · Metrologia · doi:10.1088/0026-1394/42/5/012 · Cited by 355
Self-citationProgress in atomic fountains at LNE-SYRTE
Guéna, J., Abgrall, M., Rovera, D., Laurent, P., Chupin, B., Lours, M., Santarelli, G., Rosenbusch, P., Tobar, M. E., Li, R., et al. (2012) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2012.2208 · Cited by 291
Moldover, M. R., Gavioso, R. M., Mehl, J. B., Pitre, L., de Podesta, M., & Zhang, J. (2014) · Metrologia · doi:10.1088/0026-1394/51/1/r1 · Cited by 246
Double-pass acousto-optic modulator system
Donley, E. A., Heavner, T. P., Levi, F., Tataw, M. O., & Jefferts, S. R. (2005) · Review of Scientific Instruments · doi:10.1063/1.1930095 · Cited by 237
Self-citationParker, T. E., Jefferts, S. R., Heavner, T. P., & Donley, E. A. (2005) · Metrologia · doi:10.1088/0026-1394/42/5/013 · Cited by 220
Self-citationLi, R., Gibble, K., & Szymaniec, K. (2011) · Metrologia · doi:10.1088/0026-1394/48/5/007 · Cited by 138
High-Accuracy Calculation of the Blackbody Radiation Shift in the Cs133 Primary Frequency Standard
Beloy, K., Safronova, M. S., & Derevianko, A. (2006) · Physical Review Letters · doi:10.1103/physrevlett.97.040801 · Cited by 101
Accuracy evaluation of the primary frequency standard NIST-7
Shirley, J. H., Lee, W. D., & Drullinger, R. E. (2001) · Metrologia · doi:10.1088/0026-1394/38/5/7 · Cited by 94
Self-citationDistributed cavity phase frequency shifts of the caesium fountain PTB-CSF2
Weyers, S., Gerginov, V. P., Nemitz, N., Li, R., & Gibble, K. (2011) · Metrologia · doi:10.1088/0026-1394/49/1/012 · Cited by 87
Evaluating and minimizing distributed cavity phase errors in atomic clocks
Li, R., & Gibble, K. (2010) · Metrologia · doi:10.1088/0026-1394/47/5/004 · Cited by 71
Evaluation of Doppler Shifts to Improve the Accuracy of Primary Atomic Fountain Clocks
Guéna, J., Li, R., Gibble, K., Bize, S., & Clairon, A. (2011) · Physical Review Letters · doi:10.1103/physrevlett.106.130801 · Cited by 69
Frequency Shift of the Cesium Clock Transition due to Blackbody Radiation
Angstmann, E., Dzuba, V. A., & Flambaum, V. V. (2006) · Physical Review Letters · doi:10.1103/physrevlett.97.040802 · Cited by 69
Phase variations in microwave cavities for atomic clocks
Li, R., & Gibble, K. (2004) · Metrologia · doi:10.1088/0026-1394/41/6/004 · Cited by 66
Collisional Frequency Shifts in 133Cs Fountain Clocks
Leo, P. J., Julienne, P. S., Mies, F. H., & Williams, C. J. (2001) · Physical Review Letters · doi:10.1103/physrevlett.86.3743 · Cited by 64
The relativistic redshift with 3 10 17uncertainty at NIST, Boulder, Colorado, USA
Pavlis, N. K., & Weiss, M. A. (2003) · Metrologia · doi:10.1088/0026-1394/40/2/311 · Cited by 57
Frequency pulling by hyperfine σ transitions in cesium beam atomic frequency standards
Cutler, L. S., Flory, C. A., Giffard, R. P., & Marchi, A. D. (1991) · Journal of Applied Physics · doi:10.1063/1.348637 · Cited by 55
Difference between a Photon’s Momentum and an Atom’s Recoil
Gibble, K. (2006) · Physical Review Letters · doi:10.1103/physrevlett.97.073002 · Cited by 48
Santarelli, G., Governatori, G., Chambon, D., Lours, M., Rosenbusch, P., Guéna, J., Chapelet, F., Bize, S., Tobar, M. E., Laurent, P., et al. (2009) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2009.1188 · Cited by 47
Apparatus for measuring the force of gravity on freely falling electrons
Witteborn, F. C., & Fairbank, W. M. (1977) · Review of Scientific Instruments · doi:10.1063/1.1134860 · Cited by 46
Microwave leakage-induced frequency shifts in the primary frequency Standards NIST-F1 and IEN-CSF1
Shirley, J. H., Levi, F., Heavner, T. P., Calonico, D., Yu, D.-H., & Jefferts, S. R. (2006) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2006.186 · Cited by 43
Self-citationFrequency shifts in a cesium atomic clock due to Majorana transitions
Bauch, A., & Schröder, R. (1993) · Annalen der Physik · doi:10.1002/andp.19935050502 · Cited by 41
Jefferts, S. R., Heavner, T. P., Parker, T. E., Shirley, J. H., Donley, E. A., Ashby, N., Levi, F., Calonico, D., & Costanzo, G. A. (2014) · Physical Review Letters · doi:10.1103/physrevlett.112.050801 · Cited by 36
Self-citationCavity frequency pulling in cold atom fountains
Bize, S., Sortais, Y. R. P., Mandache, C., Clairon, A., & Salomon, C. (2001) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/19.918177 · Cited by 36
Jefferts, S. R., Shirley, J. H., Ashby, N., Burt, E. A., & Dick, G. J. (2005) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2005.1563276 · Cited by 33
Self-citationHyperfine pressure shift of Cs133 atoms in noble and molecular buffer gases
Beer, C. W., & Bernheim, R. A. (1976) · Physical Review A · doi:10.1103/physreva.13.1052 · Cited by 32
Levi, F., Shirley, J. H., Heavner, T. P., Yu, D.-H., & Jefferts, S. R. (2006) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2006.1678186 · Cited by 28
Self-citationNIST cesium fountain microwave cavities
Jefferts, S. R., Drullinger, R. E., & DeMarchi, A. (2002) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/freq.1998.717869 · Cited by 24
Self-citationMajorana Transitions in an Atomic Fountain Clock
Wynands, R., Schröder, R., & Weyers, S. (2007) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2007.891116 · Cited by 23
Khursheed, A., Vecchi, G., & Marchi, A. D. (1996) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.485946 · Cited by 22
Effects of microwave leakage in caesium clocks: Theoretical and experimental results
Weyers, S., Schröder, R., & Wynands, R. (2006) · European Frequency and Time Forum · Cited by 21
A new microwave synthesis chain for the primary frequency standard NIST-F1
Heavner, T. P., Jefferts, S. R., Donley, E. A., Parker, T. E., & Levi, F. (2006) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/freq.2005.1573950 · Cited by 17
Self-citationAspects of quality assurance in monitoring solar UV irradiance
Metzdorf, J., Stock, K. D., Sperfeld, P., Sperling, A., Winter, S., & Wittchen, T. (2003) · Metrologia · doi:10.1088/0026-1394/40/1/315 · Cited by 15
Frequency shifts in NIST Cs primary frequency standards due to transverse rf field gradients
Ashby, N., Barlow, S. E., Heavner, T. P., & Jefferts, S. R. (2015) · Physical Review A · doi:10.1103/physreva.91.033624 · Cited by 9
Self-citationHeavner, T. P., Parker, T. E., Shirley, J. H., & Jefferts, S. R. (2009) · Symposium on Frequency Standards and Metrology · doi:10.1142/9789812838223_0034 · Cited by 7
Self-citationSecond generation cesium fountain primary frequency standards at NIST
Jefferts, S. R., Heavner, T. P., Donley, E. A., Shirley, J. H., & Parker, T. E. (2004) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/freq.2003.1275241 · Cited by 7
Self-citationOn the power dependence of extraneous microwave fields in atomic frequency standards
Jefferts, S. R., Shirley, J. H., Ashby, N., Heavner, T. P., Donley, E. A., & Levi, F. (2006) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/freq.2005.1573910 · Cited by 7
Self-citationLaser cooling and launching performance in a (1,1,1)-geometry atomic fountain
Donley, E. A., Heavner, T. P., O'Brien, J. W., Jefferts, S. R., & Levi, F. (2006) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/freq.2005.1573946 · Cited by 5
Self-citationShirley, J. H., & Jefferts, S. R. (2004) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/freq.2003.1275239 · Cited by 5
Self-citationLevi, F., Calosso, C. E., Calonico, D., Lorini, L., Bertacco, E. K., Godone, A., Costanzo, G. A., Mongino, B., Jefferts, S. R., Heavner, T. P., et al. (2009) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/freq.2009.5168289 · Cited by 4
Self-citationComparing room temperature and cryogenic cesium fountains
Heavner, T. P., Parker, T. E., Shirley, J. H., Donley, L. I., Jefferts, S. R., Levi, F., Calonico, D., Calosso, C. E., Costanzo, G. A., & Mongino, B. (2011) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/fcs.2011.5977845 · Cited by 3
Self-citationCesium Fountain Microwave Cavities
Jefferts, S. R., Drullinger, R. E., & Demarchi, A. (1998) · Cited by 2
Self-citation
Research works printed but not linked: 8
- Heavner T P, 2008, Proc. 2008 Symp. Frequency Standards and Metrology, 299
- Jefferts S R, 2003, Proc. 2003 Joint Meeting IEEE Int. Frequency Control Symp. and EFTF Conf., 1084
- Donley E A, 2005, Proc. 2005 Joint Meeting IEEE Int. Frequency Control Symp. and PTTI, 292
- Heavner T P, 2011, Proc. 2011 Joint Meeting IEEE Int. Frequency Control Symp. and EFTF Conf., 48
- Heavner T P, 2005, Proc. 2005 Joint Meeting IEEE Int. Frequency Control Symp. and PTTI, 308
- Shirley J H, 2003, Proc. 2003 Joint Meeting IEEE Int. Frequency Control Symp. and EFTF Conf., 1072
- Jefferts S R, 2005, Proc. 2005 Joint Meeting IEEE Int. Frequency Cont. Symp. and PTTI, 105
- Weyers S, 2006, Proc. 2006 EFTF, 173
Cited by
Sorted by citations
Search for new physics with atoms and molecules
Safronova, M. S., Budker, D., DeMille, D. P., Kimball, D. F. J., Derevianko, A., & Clark, C. W. (2018) · Reviews of Modern Physics · doi:10.1103/revmodphys.90.025008 · Cited by 1,642
Kitching, J. E., Knappe, S., Schwindt, P. D. D., Wang, Y.-J., Robinson, H., Hollberg, L. W., Liew, L.-A., Moreland, J., Brannon, A., Breitbarth, J., et al. (2006) · Applied Physics Reviews · doi:10.1063/1.5026238 · Cited by 625
Godun, R. M., Nisbet-Jones, P. B. R., Jones, J. M., King, S. A., Johnson, L. A. M., Margolis, H. S., Szymaniec, K., Lea, S. N., Bongs, K., & Gill, P. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210801 · Cited by 468
State of the Field: Extreme Precision Radial Velocities
Fischer, D. A., Anglada-Escudé, G., Arriagada, P., Baluev, R. V., Bean, J. L., Bouchy, F., Buchhave, L. A., Carroll, T. A., Chakraborty, A. G., Crepp, J. R., et al. (2016) · Publications of the Astronomical Society of the Pacific · doi:10.1088/1538-3873/128/964/066001 · Cited by 380
In-orbit operation of an atomic clock based on laser-cooled 87Rb atoms
Liu, L., Lü, D., Chen, W., Li, T., Qu, Q., Wang, B., Li, L., Ren, W., Dong, Z., Zhao, J.-B., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-05219-z · Cited by 191
Metadata
- Authors
- Heavner, T. P., Donley, E. A., Levi, F., Costanzo, G., Parker, T. E., Shirley, J. H., Ashby, N., Barlow, S., & Jefferts, S. R.
- Affiliations
- National Institute of Standards and Technology (US)
- Istituto Nazionale di Ricerca Metrologica (IT)
- Politecnico di Torino (IT)
- Corresponding author
- Heavner, Thomas P
- Venue
- Metrologia
- Publisher
- IOP Publishing
- Published
- 2014-05-01
- Volume
- 51
- Issue
- 3
- Pages
- 174-182
- ISSN
- 0026-1394 (ISSN-L)
- 1681-7575
- OpenAlex
- W2162126832
- Cited by
- 205
- References
- 47
- Citations by year
- 2026: 4 · 2025: 11 · 2024: 14 · 2023: 12 · 2022: 18 · 2021: 20 · 2020: 20 · 2019: 19 · 2018: 24 · 2017: 13 · 2016: 27 · 2015: 17 · 2014: 4
- FWCI
- 10.12
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- Metrologia (publishedVersion)
- PORTO@Iris (submittedVersion, other-oa)
- PORTO Publications Open Repository TOrino (Politecnico di Torino) (submittedVersion, other-oa)
- CINECA IRIS Institutional Research Information System (IRIS Istituto Nazionale di Ricerca Metrologica) (submittedVersion)
- Funders
- Istituto Nazionale di Ricerca Metrologica
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Electrical Measurement Techniques
- Keywords
- laser cooling, blackbody radiation shift, type B uncertainty, type A uncertainty
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review