The DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.
First accuracy evaluation of NIST-F2
Open accessAbstract
We report the first accuracy evaluation of NIST-F2, a second-generation laser-cooled caesium fountain primary standard developed at the National Institute of Standards and Technology (NIST) with a cryogenic (liquid nitrogen) microwave cavity and flight region. The 80 K atom interrogation environment reduces the uncertainty due to the blackbody radiation shift by more than a factor of 50. Also, the Ramsey microwave cavity exhibits a high quality factor (>50 000) at this low temperature, resulting in a reduced distributed cavity phase shift. NIST-F2 has undergone many tests and improvements since we first began operation in 2008. In the last few years NIST-F2 has been compared against a NIST maser time scale and NIST-F1 (the US primary frequency standard) as part of in-house accuracy evaluations. We report the results of nine in-house comparisons since 2010 with a focus on the most recent accuracy evaluation. This paper discusses the design of the physics package, the laser and optics systems and the accuracy evaluation methods. The type B fractional uncertainty of NIST-F2 is shown to be 0.11 × 10 −15 and is dominated by microwave amplitude dependent effects. The most recent evaluation (August 2013) had a statistical (type A) fractional uncertainty of 0.44 × 10 −15 .
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Microwave clocks were improved by three orders of magnitude in the past decades, now approaching the level of 10−16 (Heavner et al. 2014), see also Fig. 4.”
From Clock networks for height system unification: a simulation study (2019) · cites this paper as Heavner et al. 2014
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Happer, W. (1972) · Reviews of Modern Physics · doi:10.1103/revmodphys.44.169 · Cited by 1,720
Spin-exchange optical pumping of noble-gas nuclei
Walker, T. G., & Happer, W. (1997) · Reviews of Modern Physics · doi:10.1103/revmodphys.69.629 · Cited by 1,461
The Quantum Physics of Atomic Frequency Standards
Vanier, J., & Audoin, C. (1989) · Institute of Physics eBooks · doi:10.1887/085274434x · Cited by 624
The Quantum Physics of Atomic Frequency Standards
Vanier, J., & Tomescu, C. (2015) · CRC Press eBooks · doi:10.1201/b18738 · Cited by 554
Accuracy evaluation of NIST-F1
Jefferts, S. R., Shirley, J. H., Parker, T. E., Heavner, T. P., Meekhof, D. M., Nelson, C. W., Levi, F., Costanzo, G. A., Marchi, A. D., Drullinger, R. E., et al. (2002) · Metrologia · doi:10.1088/0026-1394/39/4/1 · Cited by 402
Self-citationWynands, R., & Weyers, S. (2005) · Metrologia · doi:10.1088/0026-1394/42/3/s08 · Cited by 374
NIST-F1: recent improvements and accuracy evaluations
Heavner, T. P., Jefferts, S. R., Donley, E. A., Shirley, J. H., & Parker, T. E. (2005) · Metrologia · doi:10.1088/0026-1394/42/5/012 · Cited by 355
Self-citationProgress in atomic fountains at LNE-SYRTE
Guéna, J., Abgrall, M., Rovera, D., Laurent, P., Chupin, B., Lours, M., Santarelli, G., Rosenbusch, P., Tobar, M. E., Li, R., et al. (2012) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2012.2208 · Cited by 291
Moldover, M. R., Gavioso, R. M., Mehl, J. B., Pitre, L., de Podesta, M., & Zhang, J. (2014) · Metrologia · doi:10.1088/0026-1394/51/1/r1 · Cited by 246
Double-pass acousto-optic modulator system
Donley, E. A., Heavner, T. P., Levi, F., Tataw, M. O., & Jefferts, S. R. (2005) · Review of Scientific Instruments · doi:10.1063/1.1930095 · Cited by 237
Self-citation
Research works printed but not linked: 8
- Heavner T P, 2008, Proc. 2008 Symp. Frequency Standards and Metrology, 299
- Jefferts S R, 2003, Proc. 2003 Joint Meeting IEEE Int. Frequency Control Symp. and EFTF Conf., 1084
- Donley E A, 2005, Proc. 2005 Joint Meeting IEEE Int. Frequency Control Symp. and PTTI, 292
- Heavner T P, 2011, Proc. 2011 Joint Meeting IEEE Int. Frequency Control Symp. and EFTF Conf., 48
- Heavner T P, 2005, Proc. 2005 Joint Meeting IEEE Int. Frequency Control Symp. and PTTI, 308
- Shirley J H, 2003, Proc. 2003 Joint Meeting IEEE Int. Frequency Control Symp. and EFTF Conf., 1072
- Jefferts S R, 2005, Proc. 2005 Joint Meeting IEEE Int. Frequency Cont. Symp. and PTTI, 105
- Weyers S, 2006, Proc. 2006 EFTF, 173
Cited by
Sorted by citations
Items 201–204 of 204
Martínez, H. Á. (2021) · theses.fr (ABES) · doi:10.70675/f4d4b814z0e3bz417fz9e16z11828e4b2ec3
Bertrand, M. (2021) · theses.fr (ABES) · doi:10.70675/fef0f0e8z8e45z4a6az91a1z93a9ea04ca90
Time-dependent adiabatic elimination in matter-wave optics
Böhringer, S., Bott, A., & Glasbrenner, E. P. (2026) · AVS Quantum Science · doi:10.1116/5.0304521
Anderson, D. A., Duspayev, A., Raithel, G. A., Simons, M. T., & Holloway, C. L. (2026) · AVS Quantum Science · doi:10.1116/5.0340257
Metadata
- Authors
- Heavner, T. P., Donley, E. A., Levi, F., Costanzo, G., Parker, T. E., Shirley, J. H., Ashby, N., Barlow, S., & Jefferts, S. R.
- Affiliations
- National Institute of Standards and Technology (US)
- Istituto Nazionale di Ricerca Metrologica (IT)
- Politecnico di Torino (IT)
- Corresponding author
- Heavner, Thomas P
- Venue
- Metrologia
- Publisher
- IOP Publishing
- Published
- 2014-05-01
- Volume
- 51
- Issue
- 3
- Pages
- 174-182
- ISSN
- 0026-1394 (ISSN-L)
- 1681-7575
- OpenAlex
- W2162126832
- Cited by
- 205
- References
- 47
- Citations by year
- 2026: 4 · 2025: 11 · 2024: 14 · 2023: 12 · 2022: 18 · 2021: 20 · 2020: 20 · 2019: 19 · 2018: 24 · 2017: 13 · 2016: 27 · 2015: 17 · 2014: 4
- FWCI
- 10.12
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- Metrologia (publishedVersion)
- PORTO@Iris (submittedVersion, other-oa)
- PORTO Publications Open Repository TOrino (Politecnico di Torino) (submittedVersion, other-oa)
- CINECA IRIS Institutional Research Information System (IRIS Istituto Nazionale di Ricerca Metrologica) (submittedVersion)
- Funders
- Istituto Nazionale di Ricerca Metrologica
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Electrical Measurement Techniques
- Keywords
- laser cooling, blackbody radiation shift, type B uncertainty, type A uncertainty
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review