Spin warp NMR imaging and applications to human whole-body imaging
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Describes a new nuclear magnetic resonance (NMR) imaging technique which the authors call 'spin warp imaging' and gives examples of its application to human whole-body imaging. The apparatus is based on a four-coil, air cored magnet (made by the Oxford Instrument Company) capable of accepting the whole human body. The magnet produces a static field of 0.04 T giving a proton NMR frequency of 1.7 MHz. The maximum field inhomogeneity is about 6*10 -4 at a radius of 0.23 m, approximately twice the amount theoretically attainable with this configuration. The pulse sequence used is shown.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tumor Detection by Nuclear Magnetic Resonance
Damadian, R. (1971) · Science · doi:10.1126/science.171.3976.1151 · Cited by 1,466
Kumar, A., Welti, D., & Ernst, R. R. (1975) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(75)90224-3 · Cited by 311
Cited by
FLASH imaging: Rapid NMR imaging using low flip-angle pulses
Haase, A., Frahm, J., Matthaei, D., Hänicke, W., & Merboldt, K.-D. (2011) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2011.09.021 · Cited by 1,153
Susceptibility-Weighted Imaging: Technical Aspects and Clinical Applications, Part 1
Haacke, E. M., Mittal, S., Wu, Z., Neelavalli, J., & Cheng, Y.-C. N. (2009) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1400 · Cited by 1,113
NMR chemical shift imaging in three dimensions.
Brown, T. R., Kincaid, B. M., & Ugurbil, K. (1982) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.79.11.3523 · Cited by 1,039
FLASH imaging. Rapid NMR imaging using low flip-angle pulses
Haase, A., Frahm, J., Matthaei, D., Hanicke, W., & Merboldt, K.-D. (1986) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(86)90433-6 · Cited by 826
The intrinsic signal-to-noise ratio in NMR imaging
Edelstein, W. A., Glover, G. H., Hardy, C. J., & Redington, R. W. (1986) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910030413 · Cited by 758
Self-citationMcRobbie, D. W., Moore, E. A., Graves, M. J., & Prince, M. R. (2017) · Cambridge University Press eBooks · doi:10.1017/9781107706958 · Cited by 752
Kissas, G., Yang, Y., Hwuang, E., Witschey, W. R., Detre, J. A., & Perdikaris, P. (2020) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2019.112623 · Cited by 647
Echo-Planar Imaging: Magnetic Resonance Imaging in a Fraction of a Second
Stehling, M. K., Turner, R., & Mansfield, P. (1991) · Science · doi:10.1126/science.1925560 · Cited by 623
Safety of Strong, Static Magnetic Fields
Schenck, J. F. (2000) · Journal of Magnetic Resonance Imaging · doi:10.1002/1522-2586(200007)12:1<2::aid-jmri2>3.0.co;2-v · Cited by 436
Rapid calculation of T1 using variable flip angle gradient refocused imaging
Fram, E. K., Herfkens, R. J., Johnson, G. A., Glover, G. H., Karis, J. P., Shimakawa, A., Perkins, T. G., & Pelc, N. J. (1987) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(87)90021-x · Cited by 388
Self-citationUndersampled projection reconstruction applied to MR angiography
Peters, D. C., Korosec, F. R., Grist, T. M., Block, W. F., Holden, J. E., Vigen, K. K., & Mistretta, C. A. (2000) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(200001)43:1<91::aid-mrm11>3.0.co;2-4 · Cited by 375
Ernst, R. R. (2011) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2011.08.006 · Cited by 314
Low-field permanent magnets for industrial process and quality control
Mitchell, J., Gladden, L. F., Chandrasekera, T. C., & Fordham, E. J. (2014) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2013.09.001 · Cited by 300
A homogeneity correction method for magnetic resonance imaging with time-varying gradients
Noll, D. C., Meyer, C. H., Pauly, J. M., Nishimura, D. G., & Macovski, A. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.108599 · Cited by 277
An analysis of fast imaging sequences with steady‐state transverse magnetization refocusing
Zur, Y., Stokar, S., & Bendel, P. (1988) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910060206 · Cited by 253
Caprihan, A., & Fukushima, E. (1990) · Physics Reports · doi:10.1016/0370-1573(90)90046-5 · Cited by 234
Physical interactions of static magnetic fields with living tissues
Schenck, J. F. (2005) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2004.08.009 · Cited by 229
Deblurring for non‐2D fourier transform magnetic resonance imaging
Noll, D. C., Pauly, J. M., Meyer, C. H., Nishimura, D. G., & Macovskj, A. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250210 · Cited by 222
Plewes, D. B., & Kucharczyk, W. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23642 · Cited by 220
MR spectroscopic imaging: Principles and recent advances
Posse, S., Otazo, R., Dager, S. R., & Alger, J. (2013) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23945 · Cited by 211
“K-space is formed by a set of spatially periodic rotations of the spin phase across the object that is generated in successive experiments by the application of the phase encoding gradients (referred to as spin warp imaging) (9) (Fig.”
MethodMRI temporal acceleration techniques
Tsao, J., & Kozerke, S. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23640 · Cited by 195
“This was originally called spin warp (97).”
Magnetic resonance imaging in laboratory petrophysical core analysis
Mitchell, J., Chandrasekera, T. C., Holland, D. J., Gladden, L. F., & Fordham, E. J. (2013) · Physics Reports · doi:10.1016/j.physrep.2013.01.003 · Cited by 188
Functional Magnetic Resonance Imaging in Medicine and Physiology
Moonen, C. T. W., van Zijl, P. C. M., Frank, J. A., Le Bihan, D., & Becker, E. D. (1990) · Science · doi:10.1126/science.2218514 · Cited by 185
Centering the projection reconstruction trajectory: Reducing gradient delay errors
Peters, D. C., Derbyshire, J. A., & McVeigh, E. R. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10501 · Cited by 163
Blockley, N. P., Griffeth, V. E. M., Simon, A. B., & Buxton, R. B. (2013) · NMR in Biomedicine · doi:10.1002/nbm.2847 · Cited by 162
Duyn, J. (2013) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2012.11.013 · Cited by 95
“While most MRI techniques have some sensitivity to signal loss and resonance frequency shifts resulting from magnetic susceptibility variations in the object, this sensitivity is particularly high for gradient echo (GRE) or free induction decay (FID) type acquisitions [28].”
Background
Metadata
- Authors
- Edelstein, W. A., Hutchison, J. M. S., Johnson, G., & Redpath, T.
- Venue
- Physics in Medicine & Biology
- Publisher
- IOP Publishing
- Published
- 1980-07-01
- Volume
- 25
- Issue
- 4
- Pages
- 751-756
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W1974670830
- Cited by
- 803
- References
- 2
- FWCI
- 26.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.