Total variation norm for three-dimensional iterative reconstruction in limited view angle tomography
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
An iterative Bayesian reconstruction algorithm for limited view angle tomography, or ectomography, based on the three-dimensional total variation (TV) norm has been developed. The TV norm has been described in the literature as a method for reducing noise in two-dimensional images while preserving edges, without introducing ringing or edge artefacts. It has also been proposed as a 2D regularization function in Bayesian reconstruction, implemented in an expectation maximization algorithm (TV-EM). The TV-EM was developed for 2D single photon emission computed tomography imaging, and the algorithm is capable of smoothing noise while maintaining edges without introducing artefacts. The TV norm was extended from 2D to 3D and incorporated into an ordered subsets expectation maximization algorithm for limited view angle geometry. The algorithm, called TV3D-EM, was evaluated using a modelled point spread function and digital phantoms. Reconstructed images were compared with those reconstructed with the 2D filtered backprojection algorithm currently used in ectomography. Results show a substantial reduction in artefacts related to the limited view angle geometry, and noise levels were also improved. Perhaps most important, depth resolution was improved by at least 45%. In conclusion, the proposed algorithm has been shown to improve the perceived image quality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonlinear total variation based noise removal algorithms
Rudin, L. I., Osher, S., & Fatemi, E. (1992) · Physica D: Nonlinear Phenomena · doi:10.1016/0167-2789(92)90242-f · Cited by 15,704
Accelerated image reconstruction using ordered subsets of projection data
Hudson, H. M., & Larkin, R. S. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.363108 · Cited by 3,711
Bayesian reconstructions from emission tomography data using a modified EM algorithm
Green, P. J. (1990) · IEEE Transactions on Medical Imaging · doi:10.1109/42.52985 · Cited by 1,241
A generalized EM algorithm for 3-D Bayesian reconstruction from Poisson data using Gibbs priors
Hebert, T., & Leahy, R. (1989) · IEEE Transactions on Medical Imaging · doi:10.1109/42.24868 · Cited by 622
Convergence of EM image reconstruction algorithms with Gibbs smoothing
Lange, K. (1990) · IEEE Transactions on Medical Imaging · doi:10.1109/42.61759 · Cited by 400
Total variation regulated EM algorithm [SPECT reconstruction]
Panin, V. Y., Zeng, G. L., & Gullberg, G. T. (1999) · IEEE Transactions on Nuclear Science · doi:10.1109/23.819305 · Cited by 183
Total variation regulated EM algorithm
Panin, V., Zeng, G. L., & Gullberg, G. T. (2002) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.1998.773841 · Cited by 100
Cited by
Sidky, E. Y., & Pan, X. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/17/021 · Cited by 1,995
Model-Based Image Reconstruction for MRI
Fessler, J. (2010) · IEEE Signal Processing Magazine · doi:10.1109/msp.2010.936726 · Cited by 335
Improved total variation-based CT image reconstruction applied to clinical data
Ritschl, L., Bergner, F., Fleischmann, C., & Kachelrieß, M. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/6/003 · Cited by 306
Sparse-view x-ray CT reconstruction via total generalized variation regularization
Niu, S., Gao, Y., Bian, Z., Huang, J., Chen, W., Yu, G., Liang, Z., & Ma, J. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/12/2997 · Cited by 291
Tang, J., Nett, B. E., & Chen, G.-H. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/19/008 · Cited by 282
Image Restoration Using Total Variation Regularized Deep Image Prior
Liu, J., Sun, Y., Xu, X., & Kamilov, U. S. (2019) · ICASSP 2019 - 2019 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP) · doi:10.1109/icassp.2019.8682856 · Cited by 186
An Introduction to Sparse Stochastic Processes
Unser, M., & Tafti, P. D. (2014) · Cambridge University Press eBooks · doi:10.1017/cbo9781107415805 · Cited by 184
Sparseness prior based iterative image reconstruction for retrospectively gated cardiac micro‐CT
Song, J., Liu, Q. H., Johnson, G. A., & Badea, C. T. (2007) · Medical Physics · doi:10.1118/1.2795830 · Cited by 183
Sidky, E. Y., Pan, X., Reiser, I. S., Nishikawa, R. M., Moore, R. H., & Kopans, D. B. (2009) · Medical Physics · doi:10.1118/1.3232211 · Cited by 181
Metadata
- Authors
- Persson, M., Bone, D., & Elmqvist, H.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2001-02-15
- Volume
- 46
- Issue
- 3
- Pages
- 853-866
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W1969899894
- Cited by
- 161
- References
- 7
- FWCI
- 1.12
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.