The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
In vivo cerebrovascular measurement combining diffuse near-infrared absorption and correlation spectroscopies
Open accessAbstract
We combine two near-infrared diffuse optical techniques to study variations of blood flow, haemoglobin concentration, and blood oxygen saturation in the functioning rat brain. Diffuse correlation spectroscopy (or flowmetry) monitors changes in the cerebral blood flow, without the use of the principles of tracer clearance, by measuring the optical phase-shifts caused by moving blood cells. Near-infrared absorption spectroscopy concurrently measures tissue absorption at two wavelengths to determine haemoglobin concentration and blood oxygen saturation in this same tissue volume. This optical probe is non-invasive and was employed through the intact skull. The utility of the technique is demonstrated in vivo by measuring the temporal changes in the regional vascular dynamics of rat brain during hypercapnia. Temporal and spatial variations of cerebral blood flow, haemoglobin concentration and blood oxygen saturation during hypercapnia are compared with other measurements in the literature, and a quantitative analysis demonstrating the self-consistency of our combined observations of vascular response is presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dynamic Light Scattering: Applications of Photon Correlation Spectroscopy
(1985) · Springer eBooks · doi:10.1007/978-1-4613-2389-1 · Cited by 4,856
Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212
Kety, S. S., & Schmidt, C. F. (1948) · Journal of Clinical Investigation · doi:10.1172/jci101995 · Cited by 1,827
Non-invasive optical spectroscopy and imaging of human brain function
Villringer, A., & Chance, B. (1997) · Trends in Neurosciences · doi:10.1016/s0166-2236(97)01132-6 · Cited by 1,618
Pine, D. J., Weitz, D. A., Chaikin, P. M., & Herbolzheimer, E. (1988) · Physical Review Letters · doi:10.1103/physrevlett.60.1134 · Cited by 1,162
Boundary conditions for the diffusion equation in radiative transfer
Haskell, R. C., Svaasand, L. O., Tsay, T.-T., Feng, T.-C., Tromberg, B. J., & McAdams, M. S. (1994) · Journal of the Optical Society of America A · doi:10.1364/josaa.11.002727 · Cited by 1,138
Malonek, D., & Grinvald, A. (1996) · Science · doi:10.1126/science.272.5261.551 · Cited by 1,097
The Effects of Changes in Pa CO 2 Cerebral Blood Volume, Blood Flow, and Vascular Mean Transit Time
GRUBB, R. L., RAICHLE, M. E., EICHLING, J. O., & TER-POGOSSIAN, M. M. (1974) · Stroke · doi:10.1161/01.str.5.5.630 · Cited by 1,044
Model for laser Doppler measurements of blood flow in tissue
Bonner, R., & Nossal, R. (1981) · Applied Optics · doi:10.1364/ao.20.002097 · Cited by 836
Spectroscopy and Imaging with Diffusing Light
Yodh, A., & Chance, B. (1995) · Physics Today · doi:10.1063/1.881445 · Cited by 800
Self-citationMultiple light scattering from disordered media. The effect of brownian motion of scatterers
Maret, G., & Wolf, P. E. (1987) · Zeitschrift f�r Physik B Condensed Matter · doi:10.1007/bf01303762 · Cited by 724
Zijlstra, W. G., Buursma, A., & Meeuwsen-van der Roest, W. P. (1991) · Clinical Chemistry · doi:10.1093/clinchem/37.9.1633 · Cited by 665
Boas, D. A., & Yodh, A. G. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.000192 · Cited by 606
Self-citationEvidence of a Cerebrovascular Postarteriole Windkessel with Delayed Compliance
Mandeville, J. B., Marota, J. J. A., Ayata, C., Zaharchuk, G., Moskowitz, M. A., Rosen, B. R., & Weisskoff, R. M. (1999) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199906000-00012 · Cited by 520
Scattering and Imaging with Diffusing Temporal Field Correlations
Boas, D. A., Campbell, L. E., & Yodh, A. G. (1995) · Physical Review Letters · doi:10.1103/physrevlett.75.1855 · Cited by 519
Self-citationKienle, A., & Patterson, M. S. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.000246 · Cited by 474
Positron Emission Tomography: Human Brain Function and Biochemistry
Phelps, M. E., & Mazziotta, J. C. (1985) · Science · doi:10.1126/science.2860723 · Cited by 469
Ingvar, D. H. (2009) · Acta Neurologica Scandinavica · doi:10.1111/j.1600-0404.1979.tb02947.x · Cited by 321
The concept of coupling blood flow to brain function: Revision required?
Lou, H. C., Edvinsson, L., & MacKenzie, E. T. (1987) · Annals of Neurology · doi:10.1002/ana.410220302 · Cited by 301
Capillary perfusion of the rat brain cortex. An in vivo confocal microscopy study.
Villringer, A., Them, A., Lindauer, U., Einhäupl, K., & Dirnagl, U. (1994) · Circulation Research · doi:10.1161/01.res.75.1.55 · Cited by 295 · cited 2×
“In this case, blood fow is estimated by counting the number of blood cells fowing through a capillary per unit time (Villringer et al 1994).”
BackgroundMethodNoninvasive Functional Imaging of Human Brain Using Light
Benaron, D. A., Hintz, S. R., Villringer, A., Boas, D., Kleinschmidt, A., Frahm, J., Hirth, C., Obrig, H., van Houten, J. C., Kermit, E. L., et al. (2000) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200003000-00005 · Cited by 239
A model for the regulation of cerebral oxygen delivery
Hyder, F., Shulman, R. G., & Rothman, D. L. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.85.2.554 · Cited by 195
Coupling of cerebral blood flow to neuronal activation: role of adenosine and nitric oxide
Dirnagl, U., Niwa, K., Lindauer, U., & Villringer, A. (1994) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1994.267.1.h296 · Cited by 191
Wang, Q., Pelligrino, D. A., Baughman, V. L., Koenig, H. M., & Albrecht, R. F. (1995) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1995.97 · Cited by 172
Near-infrared Measurement of Cerebral Oxygenation
Levy, W. J., Levin, S. K., & Chance, B. (1995) · Anesthesiology · doi:10.1097/00000542-199510000-00013 · Cited by 110
Forbes, M. L., Hendrich, K. S., Kochanek, P. M., Williams, D. S., Schiding, J. K., Wisniewski, S. R., Kelsey, S. F., DeKosky, S. T., Graham, S. H., Marion, D. W., et al. (1997) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199708000-00005 · Cited by 82
Po2 of cat cerebral cortex: Response to breathing N2 and 100% O2
Nair, P., Whalen, W. J., & Buerk, D. G. (1975) · Microvascular Research · doi:10.1016/0026-2862(75)90077-1 · Cited by 64
Danen, R. M., Wang, Y., Li, X. D., Thayer, W. S., & Yodh, A. G. (1998) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1998.tb05162.x · Cited by 61
Self-citationExamination of the role of nitric oxide for the hypercapnic rise of cerebral blood flow in rats
Fabricius, M. E., & Lauritzen, M. (1994) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1994.266.4.h1457 · Cited by 60
Barfod, C., Akgören, N., Fabricius, M. E., Dirnagl, U., & Lauritzen, M. (1997) · Acta Physiologica Scandinavica · doi:10.1046/j.1365-201x.1997.00130.x · Cited by 44
What are the goals of magnetic resonance research?
Chance, B. (1989) · NMR in Biomedicine · doi:10.1002/nbm.1940020503 · Cited by 12
Rosenblum, W. I. (1996) · Microcirculation · doi:10.3109/10739689609148287 · Cited by 6
Cited by
Diffuse optics for tissue monitoring and tomography
Durduran, T., Choe, R., Baker, W. B., & Yodh, A. G. (2010) · Reports on Progress in Physics · doi:10.1088/0034-4885/73/7/076701 · Cited by 1,161
Self-citationDiffuse correlation spectroscopy for non-invasive, micro-vascular cerebral blood flow measurement
Durduran, T., & Yodh, A. G. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.06.017 · Cited by 536
Self-citationCulver, J. P., Durduran, T., Furuya, D., Cheung, C., Greenberg, J. H., & Yodh, A. G. (2003) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/01.wcb.0000076703.71231.bb · Cited by 420
Self-citationDurduran, T., Yu, G., Burnett, M. G., Detre, J. A., Greenberg, J. H., Wang, J., Zhou, C., & Yodh, A. G. (2004) · Optics Letters · doi:10.1364/ol.29.001766 · Cited by 346
Self-citationKim, M. N., Durduran, T., Frangos, S., Edlow, B. L., Buckley, E. M., Moss, H. E., Zhou, C., Yu, G., Choe, R., Maloney-Wilensky, E., et al. (2010) · Neurocritical Care · doi:10.1007/s12028-009-9305-x · Cited by 306
Self-citation
Metadata
- Authors
- Cheung, C., Culver, J. P., Takahashi, K., Greenberg, J. H., & Yodh, A. G.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2001-07-06
- Volume
- 46
- Issue
- 8
- Pages
- 2053-2065
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2124835578
- Cited by
- 308
- References
- 32
- FWCI
- 8.41
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.