In vivo cerebrovascular measurement combining diffuse near-infrared absorption and correlation spectroscopies
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
We combine two near-infrared diffuse optical techniques to study variations of blood flow, haemoglobin concentration, and blood oxygen saturation in the functioning rat brain. Diffuse correlation spectroscopy (or flowmetry) monitors changes in the cerebral blood flow, without the use of the principles of tracer clearance, by measuring the optical phase-shifts caused by moving blood cells. Near-infrared absorption spectroscopy concurrently measures tissue absorption at two wavelengths to determine haemoglobin concentration and blood oxygen saturation in this same tissue volume. This optical probe is non-invasive and was employed through the intact skull. The utility of the technique is demonstrated in vivo by measuring the temporal changes in the regional vascular dynamics of rat brain during hypercapnia. Temporal and spatial variations of cerebral blood flow, haemoglobin concentration and blood oxygen saturation during hypercapnia are compared with other measurements in the literature, and a quantitative analysis demonstrating the self-consistency of our combined observations of vascular response is presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dynamic Light Scattering: Applications of Photon Correlation Spectroscopy
(1985) · Springer eBooks · doi:10.1007/978-1-4613-2389-1 · Cited by 4,856
Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.
Kwong, K. K., Belliveau, J. W., Chesler, D. A., Goldberg, I. E., Weisskoff, R. M., Poncelet, B. P., Kennedy, D. N., Hoppel, B. E., Cohen, M. S., & Turner, R. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.12.5675 · Cited by 4,212
Kety, S. S., & Schmidt, C. F. (1948) · Journal of Clinical Investigation · doi:10.1172/jci101995 · Cited by 1,827
Non-invasive optical spectroscopy and imaging of human brain function
Villringer, A., & Chance, B. (1997) · Trends in Neurosciences · doi:10.1016/s0166-2236(97)01132-6 · Cited by 1,618
Pine, D. J., Weitz, D. A., Chaikin, P. M., & Herbolzheimer, E. (1988) · Physical Review Letters · doi:10.1103/physrevlett.60.1134 · Cited by 1,162
Boundary conditions for the diffusion equation in radiative transfer
Haskell, R. C., Svaasand, L. O., Tsay, T.-T., Feng, T.-C., Tromberg, B. J., & McAdams, M. S. (1994) · Journal of the Optical Society of America A · doi:10.1364/josaa.11.002727 · Cited by 1,138
Malonek, D., & Grinvald, A. (1996) · Science · doi:10.1126/science.272.5261.551 · Cited by 1,097
The Effects of Changes in Pa CO 2 Cerebral Blood Volume, Blood Flow, and Vascular Mean Transit Time
GRUBB, R. L., RAICHLE, M. E., EICHLING, J. O., & TER-POGOSSIAN, M. M. (1974) · Stroke · doi:10.1161/01.str.5.5.630 · Cited by 1,044
Model for laser Doppler measurements of blood flow in tissue
Bonner, R., & Nossal, R. (1981) · Applied Optics · doi:10.1364/ao.20.002097 · Cited by 836
Spectroscopy and Imaging with Diffusing Light
Yodh, A., & Chance, B. (1995) · Physics Today · doi:10.1063/1.881445 · Cited by 800
Self-citation
Cited by
Diffuse optics for tissue monitoring and tomography
Durduran, T., Choe, R., Baker, W. B., & Yodh, A. G. (2010) · Reports on Progress in Physics · doi:10.1088/0034-4885/73/7/076701 · Cited by 1,161
Self-citationDiffuse correlation spectroscopy for non-invasive, micro-vascular cerebral blood flow measurement
Durduran, T., & Yodh, A. G. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.06.017 · Cited by 536
Self-citationCulver, J. P., Durduran, T., Furuya, D., Cheung, C., Greenberg, J. H., & Yodh, A. G. (2003) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/01.wcb.0000076703.71231.bb · Cited by 420
Self-citationDurduran, T., Yu, G., Burnett, M. G., Detre, J. A., Greenberg, J. H., Wang, J., Zhou, C., & Yodh, A. G. (2004) · Optics Letters · doi:10.1364/ol.29.001766 · Cited by 346
Self-citationKim, M. N., Durduran, T., Frangos, S., Edlow, B. L., Buckley, E. M., Moss, H. E., Zhou, C., Yu, G., Choe, R., Maloney-Wilensky, E., et al. (2010) · Neurocritical Care · doi:10.1007/s12028-009-9305-x · Cited by 306
Self-citationRoche‐Labarbe, N., Carp, S. A., Surova, A., Patel, M., Boas, D. A., Grant, P. E., & Franceschini, M. A. (2010) · Human Brain Mapping · doi:10.1002/hbm.20868 · Cited by 236
“As detailed in [Boas et al., 1995; Boas and Yodh, 1997] and further validated in [ Cheung et al., 2001; Culver et al., 2003; Durduran et al., 2004a; Durduran et al., 2005] the normalized intensity temporal auto-correlation function, g2(s), is given by:”
BackgroundMethodInfluentialYu, G., Durduran, T., Zhou, C., Wang, H.-W., Putt, M. E., Saunders, H. M., Sehgal, C. M., Glatstein, E., Yodh, A. G., & Busch, T. M. (2005) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-04-2582 · Cited by 234
“We have found that both of these models fit our data, but the latter model often provides better quality fits ( 23 ).”
BackgroundResultSelf-citationZhou, C., Yu, G., Furuya, D., Greenberg, J. H., Yodh, A. G., & Durduran, T. (2006) · Optics Express · doi:10.1364/oe.14.001125 · Cited by 232
Self-citationYu, G., Durduran, T., Lech, G., Zhou, C., Chance, B., Mohler, E. R., & Yodh, A. G. (2005) · Journal of Biomedical Optics · doi:10.1117/1.1884603 · Cited by 230
“The lack of portable, noninvasive technologies for continuous monitoring of both blood flow and oxygenation in the deep microcirculation~capillary bed! has led us to develop a hybrid instrument combining near-infrared DCS and diffuse reflectance spectroscopy ~DRS!.(19,20)DCS monitors blood flow by effectively measurin…”
BackgroundSelf-citationDiffuse correlation spectroscopy for measurement of cerebral blood flow: future prospects
Buckley, E. M., Parthasarathy, A. B., Grant, P. E., Yodh, A. G., & Franceschini, M. A. (2014) · Neurophotonics · doi:10.1117/1.nph.1.1.011009 · Cited by 216
“DCS has been used in animal models to study baseline and activated hemodynamics as well as related metabolic changes.(36) DCS has also been used to study diseases such as ischemic stroke,(37,38) phenomena such as cortical spreading depressions,(39) and CBF responses to different anesthetics and carbon dioxide.”
MethodSelf-citationDurduran, T., Zhou, C., Buckley, E. M., Kim, M. N., Yu, G., Choe, R., Gaynor, J. W., Spray, T. L., Durning, S. M., Mason, S. E., et al. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3425884 · Cited by 196
Self-citationDirect measurement of tissue blood flow and metabolism with diffuse optics
Mesquita, R. C., Durduran, T., Yu, G., Buckley, E. M., Kim, M. N., Zhou, C., Choe, R., Sunar, U., & Yodh, A. G. (2011) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2011.0232 · Cited by 195
Self-citationBuckley, E. M., Cook, N. M., Durduran, T., Kim, M. N., Zhou, C., Choe, R., Yu, G., Schultz, S., Sehgal, C. M., Licht, D. J., et al. (2009) · Optics Express · doi:10.1364/oe.17.012571 · Cited by 179
Self-citationThe effect of different anesthetics on neurovascular coupling
Franceschini, M. A., Radhakrishnan, H., Thakur, K., Wu, W., Ruvinskaya, S., Carp, S., & Boas, D. A. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.03.060 · Cited by 173
“Our DCS system employs a solid-state long coherence length laser (785 nm, ∼70 mW of power) to illuminate the surface of the head and four photon-counting avalanche photodiodes connected to four single-mode optical fibers to collect the diffusely reflected light (Roche-Labarbe et al., 2010).”
BackgroundMethodInfluentialOptical imaging and spectroscopy for the study of the human brain: status report
Ayaz, H., Baker, W. B., Blaney, G., Boas, D. A., Bortfeld, H., Brady, K., Brake, J., Brigadoi, S., Buckley, E. M., Carp, S. A., et al. (2022) · Neurophotonics · doi:10.1117/1.nph.9.s2.s24001 · Cited by 170
Self-citationNoninvasive detection of functional brain activity with near-infrared diffusing-wave spectroscopy
Li, J., Dietsche, G., Iftime, D., Skipetrov, S. E., Maret, G., Elbert, T., Rockstroh, B., & Gisler, T. (2005) · Journal of Biomedical Optics · doi:10.1117/1.2007987 · Cited by 166
“While the shape of the measured field autocorrelation functions reported by Cheung et al.30 deviates from predictions for simple diffusion or random flow, the correction factor used by Durduran et al.32 suggests that using DWS to quantitatively determine cortical perfusion rates in an entirely noninvasive way is likel…”
BackgroundMethodInfluentialTranscranial optical monitoring of cerebrovascular hemodynamics in acute stroke patients
Durduran, T., Zhou, C., Edlow, B. L., Yu, G., Choe, R., Kim, M. N., Cucchiara, B. L., Putt, M. E., Shah, Q., Kasner, S. E., et al. (2009) · Optics Express · doi:10.1364/oe.17.003884 · Cited by 166
Self-citationNear‐Infrared Diffuse Optical Tomography
Hielscher, A. H., Bluestone, A. Y., Abdoulaev, G. S., Klose, A. D., Lasker, J., Stewart, M., Netz, U., & Beuthan, J. (2002) · Disease Markers · doi:10.1155/2002/164252 · Cited by 159
Gurley, K., Shang, Y., & Yu, G. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.7.075010 · Cited by 81
Metadata
- Authors
- Cheung, C., Culver, J. P., Takahashi, K., Greenberg, J. H., & Yodh, A. G.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2001-07-06
- Volume
- 46
- Issue
- 8
- Pages
- 2053-2065
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2124835578
- Cited by
- 308
- References
- 32
- FWCI
- 8.41
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.