Three-dimensional optical tomography of the premature infant brain
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
For the first time, three-dimensional images of the newborn infant brain have been generated using measurements of transmitted light. A 32-channel time-resolved imaging system was employed, and data were acquired using custom-made helmets which couple source fibres and detector bundles to the infant head. Images have been reconstructed using measurements of mean flight time relative to those acquired on a homogeneous reference phantom, and using a head-shaped 3D finite-element-based forward model with an external boundary constrained to match the measured positions of the sources and detectors. Results are presented for a premature infant with a cerebral haemorrhage predominantly located within the left ventricle. Images representing the distribution of absorption at 780 nm and 815 nm reveal an asymmetry consistent with the haemorrhage, and corresponding maps of blood volume and fractional oxygen saturation are generally within expected physiological values.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
Optical tomography in medical imaging
Arridge, S. R. (1999) · Inverse Problems · doi:10.1088/0266-5611/15/2/022 · Cited by 2,524
Self-citationWyatt, J. S., Delpy, D. T., Cope, M., Wray, S., & Reynolds, E. O. R. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90467-8 · Cited by 876
Self-citationThe Accuracy of Near Infrared Spectroscopy and Imaging during Focal Changes in Cerebral Hemodynamics
Boas, D. A., Gaudette, T., Strangman, G., Cheng, X., Marota, J. J. A., & Mandeville, J. B. (2001) · NeuroImage · doi:10.1006/nimg.2000.0674 · Cited by 459
Quantitation of cerebral blood volume in human infants by near-infrared spectroscopy
Wyatt, J. S., Cope, M., Delpy, D. T., Richardson, C. E., Edwards, A. D., Wray, S., & Reynolds, E. O. (1990) · Journal of Applied Physiology · doi:10.1152/jappl.1990.68.3.1086 · Cited by 442
Self-citationCOTSIDE MEASUREMENT OF CEREBRAL BLOOD FLOW IN ILL NEWBORN INFANTS BY NEAR INFRARED SPECTROSCOPY
Edwards, A. D., Richardson, C., Cope, M., Wyatt, J. S., Delpy, D. T., & Reynolds, E. O. R. (1988) · The Lancet · doi:10.1016/s0140-6736(88)92418-x · Cited by 370
Self-citationNoninvasive Monitoring of Cerebral Oxygenation in Preterm Infants: Preliminary Observations
Brazy, J. E., Lewis, D. V., Mitnick, M. H., & vander Vliet, F. F. J. (1985) · Pediatrics · doi:10.1542/peds.75.2.217 · Cited by 356
Frequency-domain techniques enhance optical mammography: Initial clinical results
Franceschini, M. A., Moesta, K. T., Fantini, S., Gaida, G., Gratton, E., Jess, H., Mantulin, W. W., Seeber, M., Schlag, P. M., & Kaschke, M. F. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.12.6468 · Cited by 355
A novel method for fast imaging of brain function, non-invasively, with light
Chance, B., Anday, E., Nioka, S., Zhou, S., Hong, L., Worden, K., Li, C., Murray, T., Ovetsky, Y., Pidikiti, D., et al. (1998) · Optics Express · doi:10.1364/oe.2.000411 · Cited by 307
A 32-channel time-resolved instrument for medical optical tomography
Schmidt, F. E. W., Fry, M. E., Hillman, E. M. C., Hebden, J. C., & Delpy, D. T. (2000) · Review of Scientific Instruments · doi:10.1063/1.1150191 · Cited by 260
Self-citationThree-dimensional optical tomography of hemodynamics in the human head
Bluestone, A. Y., Abdoulaev, G., Schmitz, C. H., Barbour, R. L., & Hielscher, A. H. (2001) · Optics Express · doi:10.1364/oe.9.000272 · Cited by 259
Noninvasive Functional Imaging of Human Brain Using Light
Benaron, D. A., Hintz, S. R., Villringer, A., Boas, D., Kleinschmidt, A., Frahm, J., Hirth, C., Obrig, H., van Houten, J. C., Kermit, E. L., et al. (2000) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200003000-00005 · Cited by 239
Multichannel time-resolved optical tomographic imaging system
Eda, H., Oda, I., Ito, Y., Wada, Y., Oikawa, Y., Tsunazawa, Y., Takada, M., Tsuchiya, Y., Yamashita, Y., Oda, M., et al. (1999) · Review of Scientific Instruments · doi:10.1063/1.1149965 · Cited by 170
Skov, L., Pryds, O., & Greisen, G. (1991) · Pediatric Research · doi:10.1203/00006450-199112000-00016 · Cited by 168
Design and evaluation of a continuous-wave diffuse optical tomography system
Siegel, A., Marota, J. J., & Boas, D. (1999) · Optics Express · doi:10.1364/oe.4.000287 · Cited by 163
Image reconstruction in optical tomography
Arridge, S. R., & Schweiger, M. (1997) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.1997.0054 · Cited by 160
Self-citationAbnormal cerebral haemodynamics in perinatally asphyxiated neonates related to outcome
Meek, J. H., Elwell, C. E., McCormick, D., Edwards, A. D., Townsend, J., STEWART, A. L., & Wyatt, J. S. (1999) · Archives of Disease in Childhood Fetal & Neonatal · doi:10.1136/fn.81.2.f110 · Cited by 151
Self-citationTime resolved optical tomography of the human forearm
Hillman, E. M. C., Hebden, J. C., Schweiger, M., Dehghani, H., Schmidt, F. E. W., Delpy, D. T., & Arridge, S. R. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/4/315 · Cited by 146
Self-citationNtziachristos, V., Ma, X., & Chance, B. (1998) · Review of Scientific Instruments · doi:10.1063/1.1149235 · Cited by 142
Taga, G., Konishi, Y., Maki, A., Tachibana, T., Fujiwara, M., & Koizumi, H. (2000) · Neuroscience Letters · doi:10.1016/s0304-3940(00)00874-0 · Cited by 141
Bedside functional imaging of the premature infant brain during passive motor activation
Hintz, S. R., Benaron, D. A., Siegel, A. M., Zourabian, A., Stevenson, D. K., & Boas, D. A. (2001) · Journal of Perinatal Medicine · doi:10.1515/jpm.2001.048 · Cited by 137
New non-invasive methods for assessing brain oxygenation and haemodynamics
Reynolds, E. O. R., Wyatt, J. S., Azzopardi, D., Delpy, D. T., Cady, E. B., Cope, M., & Wray, S. (1988) · British Medical Bulletin · doi:10.1093/oxfordjournals.bmb.a072289 · Cited by 117
Self-citationMeasurement and modelling of the optical properties of human tissue in the near infrared.
van der Zee, P. (1993) · OpenGrey (Institut de l'Information Scientifique et Technique) · Cited by 80
Near-infrared spectroscopy for the in vivo study of cerebral hemodynamics and oxygenation
du Plessis, A. J. (1995) · The Journal of Pediatrics · doi:10.1097/00008480-199512000-00002 · Cited by 31
Cited by
Diffuse optics for tissue monitoring and tomography
Durduran, T., Choe, R., Baker, W. B., & Yodh, A. G. (2010) · Reports on Progress in Physics · doi:10.1088/0034-4885/73/7/076701 · Cited by 1,161
Recent advances in diffuse optical imaging
Gibson, A. P., Hebden, J. C., & Arridge, S. R. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/4/r01 · Cited by 1,114
Self-citationPrinciples, Techniques, and Limitations of Near Infrared Spectroscopy
Ferrari, M., Mottola, L., & Quaresima, V. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-031 · Cited by 997
Dehghani, H., Eames, M. E., Yalavarthy, P. K., Davis, S. C., Srinivasan, S., Carpenter, C. M., Pogue, B. W., & Paulsen, K. D. (2009) · Communications in Numerical Methods in Engineering · doi:10.1002/cnm.1162 · Cited by 728
NIR Spectroscopy Applications for Internal and External Quality Analysis of Citrus Fruit—A Review
Magwaza, L. S., Opara, U. L., Nieuwoudt, H., Cronje, P. J. R., Saeys, W., & Nicolaï, B. (2012) · Food and Bioprocess Technology · doi:10.1007/s11947-011-0697-1 · Cited by 465
Metadata
- Authors
- Hebden, J. C., Gibson, A., Yusof, R. M., Everdell, N., Hillman, E. M. C., Delpy, D. T., Arridge, S. R., Austin, T., Meek, J. H., & Wyatt, J. S.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2002-11-12
- Volume
- 47
- Issue
- 23
- Pages
- 4155-4166
- ISSN
- 0031-9155 (ISSN-L)
- OpenAlex
- W2136102531
- Cited by
- 288
- References
- 24
- FWCI
- 14.11
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.