Image reconstruction in optical tomography
Open accessThe DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
Optical tomography is a new medical imaging modality that is at the threshold of realization. A large amount of clinical work has shown the very real benefits that such a method could provide. At the same time a considerable effort has been put into theoretical studies of its probable success. At present there exist gaps between these two realms. In this paper we review some general approaches to inverse problems to set the context for optical tomography, defining both the terms forward problem and inverse problem. An essential requirement is to treat the problem in a nonlinear fashion, by using an iterative method. This in turn requires a convenient method of evaluating the forward problem, and its derivatives and variance. Photon transport models are described and methods for obtaining analytical and numerical solutions for the most commonly used ones are reviewed. The inverse problem is approached by classical gradient–based solution methods. In order to develop practical implementations of these methods, we discuss the important topic of photon measurement density functions, which represent the derivative of the forward problem. We show some results that represent the most complex and realistic simulations of optical tomography yet developed. We suggest, in particular, that both time–resolved, and intensity–modulated systems can reconstruct variations in both optical absorption and scattering, but that unmodulated, non–time–resolved systems are prone to severe artefact. We believe that optical tomography reconstruction methods can now be reliably applied to a wide variety of real clinical data. The expected resolution of the method is poor, meaning that it is unlikely that the type of high–resolution images seen in computed tomography or medical resonance imaging can ever be obtained. Nevertheless we strongly expect the functional nature of these images to have a high degree of clinical significance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wave Propagation and Scattering in Random Media
(1978) · Elsevier eBooks · doi:10.1016/c2013-0-10906-3 · Cited by 4,709
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
Wave Propagation and Scattering in Random Media
(1978) · Elsevier eBooks · doi:10.1016/b978-0-12-374701-3.x5001-7 · Cited by 2,447
Estimation of optical pathlength through tissue from direct time of flight measurement
Delpy, D. T., Cope, M., Zee, P. V. D., Arridge, S., Wray, S., & Wyatt, J. (1988) · Physics in Medicine and Biology · doi:10.1088/0031-9155/33/12/008 · Cited by 2,245
Self-citationPatterson, M. S., Chance, B., & Wilson, B. C. (1989) · Applied Optics · doi:10.1364/ao.28.002331 · Cited by 2,087 · cited 1×
“Green’s functions for various homogeneous geometries (slabs, cylinders, spheres) have been published, for both the time- and frequency- domains (Patterson et al. 1989; Arridge et al. 1992a).”
BackgroundThe Mathematics of Computerized Tomography
Natterer, F. (1986) · Vieweg+Teubner eBooks · doi:10.1007/978-3-663-01409-6 · Cited by 1,768
Case, K. M., Zweifel, P. F., & Pomraning, G. C. (1968) · Physics Today · doi:10.1063/1.3034554 · Cited by 1,609
Duderstadt, J. J., & Hamilton, L. J. (1976) · Deep Blue (University of Michigan) · Cited by 1,603
Cope, M., & Delpy, D. T. (1988) · Medical & Biological Engineering & Computing · doi:10.1007/bf02447083 · Cited by 1,065
A finite element approach for modeling photon transport in tissue
Arridge, S. R., Schweiger, M., Hiraoka, M., & Delpy, D. T. (1993) · Medical Physics · doi:10.1118/1.597069 · Cited by 635 · cited 4×
“We have shown previously that non-timeresolved methods are unable to distinguish between the two images simultaneously (Arridge et al. 1993b), which is a serious shortcoming of some approaches that only attempt reconstruction of µ a (r).”
BackgroundMethodInfluentialSelf-citation
Cited by
Optical coherence tomography - principles and applications
Fercher, A. F., Drexler, W., Hitzenberger, C. K., & Lasser, T. (2003) · Reports on Progress in Physics · doi:10.1088/0034-4885/66/2/204 · Cited by 1,866
Image reconstruction by domain-transform manifold learning
Zhu, B., Liu, J. Z., Cauley, S. F., Rosen, B. R., & Rosen, M. S. (2018) · Nature · doi:10.1038/nature25988 · Cited by 1,694
“We assume that (1) there exists a unknown smooth and homeomorphic function f: R! → R! , such that y = f(x), and (2) (x!)!!! ! ,(y!)!!! ! lie on unknown smooth manifolds X and Y, respectively.”
BackgroundDiffuse optics for tissue monitoring and tomography
Durduran, T., Choe, R., Baker, W. B., & Yodh, A. G. (2010) · Reports on Progress in Physics · doi:10.1088/0034-4885/73/7/076701 · Cited by 1,161
Non-invasive neuroimaging using near-infrared light
Strangman, G., Boas, D. A., & Sutton, J. P. (2002) · Biological Psychiatry · doi:10.1016/s0006-3223(02)01550-0 · Cited by 903
Efimov, I. R., Nikolski, V. P., & Salama, G. (2004) · Circulation Research · doi:10.1161/01.res.0000130529.18016.35 · Cited by 390
Metadata
- Authors
- Arridge, S. R., & Schweiger, M.
- Venue
- Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences
- Publisher
- The Royal Society
- Published
- 1997-06-29
- Volume
- 352
- Issue
- 1354
- Pages
- 717-726
- ISSN
- 0962-8436 (ISSN-L)
- 1471-2970
- OpenAlex
- W2029022756
- Cited by
- 160
- References
- 27
- FWCI
- 6.42
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Image reconstruction in optical tomography. https://app.cochat.ai/papers/10.1098/rstb.1997.0054
- The paper
- Arridge, S. R., & Schweiger, M. (1997). Image reconstruction in optical tomography. Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences. https://doi.org/10.1098/rstb.1997.0054
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.